{ "layers": [ { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 100, "name": "Water", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 110, "name": "Fire Hydrant" }, { "id": 120, "name": "Valve" }, { "id": 130, "name": "Water Service Line" }, { "id": 140, "name": "Water Main Line" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 629119.0055, "ymin": 641136.5834999979, "xmax": 730761.9334999993, "ymax": 689819.7924999967, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 110, "name": "Fire Hydrant", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "a937b00a36d23e932454e5ca12261ef9", "imageData": "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", "contentType": "image/png", "width": 15, "height": 15, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674845.4305000007, "ymin": 643527.4575000033, "xmax": 709217.8770000003, "ymax": 689815.6180000007, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "HydrantSize", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "HydrantSize", "type": "esriFieldTypeSmallInteger", "alias": "Hydrant Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Fire Hydrant Size", "description": "Valid water firy hydrant size values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1153Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1153HydrantSize", "fields": "HydrantSize", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S522_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910583000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 120, "name": "Valve", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "c946d9971eaf14829f5c5eb2f6a5b2e4", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAwAAAAMCAYAAABWdVznAAAACXBIWXMAAA7EAAAOxAGVKw4bAAABS0lEQVQokZWRMUvDUBSFz2v6aESXgpASiIsduhRFOuhcS0a7tViQ/gOHBNKt0K1bnSUtxYZO7tK1FJIhiy4BQQgJSbo4FAcRyZMWLAar4lnO5Vy+y4WTxj+V3hQyxnYBbAPwCCHxj0Cr1TqNoqivqqrEGEMqlXpxHOeyUCj0vwG1Wu14PB7fmabJ5XK5VTadTnfq9boeBAEniuJ1AvA8z3Bdl6tWq5hMJgjDcHlk5YPB4IoxdkMIeV0DjuPsLd2yLJTLZfi+jyiKVrvZbLYF4BCAuQYopexzzufziON4DWQymaW9JV4qFosP8/n8qNFoYDgcYrFYoFKpwLZtyLL8DOA+AQiCcFYqlR7b7TbPcRyy2Sw6nQ50XWfNZvOcEPKeAAzD8Lvd7n6v17ullB4QQqgkSU+j0eiC53lrYw+apgUATr5miqL83fRv+gBzznkGr2cq2QAAAABJRU5ErkJggg==", "contentType": "image/png", "width": 9, "height": 9, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674797.6114999987, "ymin": 643527.0520000011, "xmax": 709220.2609999999, "ymax": 689807.6840000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "ValveType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ValveType", "type": "esriFieldTypeString", "alias": "Valve Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Valve Type", "description": "Valid water valve type values", "codedValues": [ { "name": "Gate", "code": "Gate" }, { "name": "Butterfly", "code": "Butterfly" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ValveSize", "type": "esriFieldTypeSmallInteger", "alias": "Valve Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Valve Size", "description": "Valid water valve size values", "codedValues": [ { "name": "2", "code": 2 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 }, { "name": "14", "code": 14 }, { "name": "16", "code": 16 }, { "name": "18", "code": 18 }, { "name": "20", "code": 20 }, { "name": "24", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1167Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167ValveSize", "fields": "ValveSize", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167ValveType", "fields": "ValveType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S536_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910666000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 130, "name": "Water Service Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSDashDotDot", "color": [ 0, 92, 230, 255 ], "width": 1 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 629119.0055, "ymin": 643527.0520000011, "xmax": 730761.9334999993, "ymax": 689815.6180000007, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "ServiceLineType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ServiceLineType", "type": "esriFieldTypeString", "alias": "Service Line Type", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Service Line Type", "description": "Valid water service line type values", "codedValues": [ { "name": "Culinary Service", "code": "Culinary Service" }, { "name": "Sprinkler Service", "code": "Sprinkler Service" }, { "name": "Fire Service", "code": "Fire Service" }, { "name": "Fire Hydrant Service", "code": "Fire Hydrant Service" }, { "name": "Flush Hydrant Service", "code": "Flush Hydrant Service" }, { "name": "Culinary / Fire Service", "code": "Culinary / Fire Service" }, { "name": "Culinary / Fire Hydrant", "code": "Culinary / Fire Hydrant" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Size", "type": "esriFieldTypeDouble", "alias": "Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Service Line Size", "description": "Valid water service line size values", "codedValues": [ { "name": "0.5", "code": 0.5 }, { "name": "0.75", "code": 0.75 }, { "name": "1", "code": 1 }, { "name": "1.25", "code": 1.25 }, { "name": "1.5", "code": 1.5 }, { "name": "2", "code": 2 }, { "name": "2.5", "code": 2.5 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1152Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1152Size", "fields": "Size", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1152ServiceLine", "fields": "ServiceLineType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S521_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910566000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 140, "name": "Water Main Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 92, 230, 255 ], "width": 2 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner IN ('Private', 'Parks')", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 0, 92, 230, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 669954.2635000013, "ymin": 641136.5834999979, "xmax": 730486.3040000014, "ymax": 689819.7924999967, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Main Line Diameter", "description": "Valid water main line diameter values", "codedValues": [ { "name": "2", "code": 2 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 }, { "name": "14", "code": 14 }, { "name": "16", "code": 16 }, { "name": "18", "code": 18 }, { "name": "20", "code": 20 }, { "name": "24", "code": 24 }, { "name": "120", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1154Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1154Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1154Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S523_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910588000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 200, "name": "Sewer", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 210, "name": "Sewer Manhole" }, { "id": 220, "name": "Sewer Line" }, { "id": 230, "name": "Sewer Service Line" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 695866.438000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 210, "name": "Sewer Manhole", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "59db18049bc3de0810162914226eae5e", "imageData": "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", "contentType": "image/png", "width": 14, "height": 14, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 689763.7950000018, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "ManholeID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ManholeID", "type": "esriFieldTypeString", "alias": "Manhole ID", "length": 20, "domain": null }, { "name": "ManholeDiameter", "type": "esriFieldTypeSmallInteger", "alias": "Manhole Diameter (ft.)", "domain": { "type": "codedValue", "name": "WS2_UTIL Manhole Diameter", "description": "Valid utility manhole diameter values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "7", "code": 7 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "3", "code": 3 }, { "name": "5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeCoverSize", "type": "esriFieldTypeDouble", "alias": "Manhole Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Owner", "description": "Valid sewer owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "IBSD", "code": "IBSD" }, { "name": "Ammon", "code": "Ammon" }, { "name": "Private", "code": "Private" }, { "name": "Ucon", "code": "Ucon" }, { "name": "EIRSD", "code": "EIRSD" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeDouble", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "OutletElevation", "type": "esriFieldTypeDouble", "alias": "Outlet Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1245Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1245ManholeID", "fields": "ManholeID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S560_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915706000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 220, "name": "Sewer Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner = 'Private'", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 56, 168, 0, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 695866.438000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "PipeType", "type": "esriFieldTypeString", "alias": "Pipe Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Pipe Type", "description": "Valid sewer pipe type values", "codedValues": [ { "name": "Gravity", "code": "Gravity" }, { "name": "Forced Main", "code": "Forced Main" }, { "name": "Elevated", "code": "Elevated" }, { "name": "Siphon", "code": "Siphon" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "range", "name": "WS2_SWR Line Diameter", "description": "Valid sewer line diameter values", "range": [ 4, 60 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Owner", "description": "Valid sewer owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "IBSD", "code": "IBSD" }, { "name": "Ammon", "code": "Ammon" }, { "name": "Private", "code": "Private" }, { "name": "Ucon", "code": "Ucon" }, { "name": "EIRSD", "code": "EIRSD" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "UpInvertElevation", "type": "esriFieldTypeDouble", "alias": "Up Invert Elevation (ft.)", "domain": null }, { "name": "DownInvertElevation", "type": "esriFieldTypeDouble", "alias": "Down Invert Elevation (ft.)", "domain": null }, { "name": "Slope", "type": "esriFieldTypeDouble", "alias": "Slope", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "Collector_ID", "type": "esriFieldTypeString", "alias": "Collector ID", "length": 20, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1240Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240PipeType", "fields": "PipeType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S555_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915662000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 230, "name": "Sewer Service Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSDashDotDot", "color": [ 56, 168, 0, 255 ], "width": 1 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673163.9090000018, "ymin": 643612.2924999967, "xmax": 723950.1735000014, "ymax": 687739.5689999983, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "codedValue", "name": "WS2_SWR Service Line Diameter", "description": "Valid sewer service line diameter values", "codedValues": [ { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "5", "code": 5 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1244Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1244Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S559_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915692000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 300, "name": "Storm", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 310, "name": "Dry Well" }, { "id": 320, "name": "French Drain" }, { "id": 330, "name": "Storm Manhole" }, { "id": 340, "name": "Inlet Box" }, { "id": 350, "name": "Catch Basin" }, { "id": 360, "name": "Storm Line" }, { "id": 370, "name": "Other Conveyance" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 673209.5789999999, "ymin": 638864.5090000033, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 310, "name": "Dry Well", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "d4a8a7cb844e95944057ded944b3f151", "imageData": "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", "contentType": "image/png", "width": 16, "height": 16, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 679329.7030000016, "ymin": 659167.699000001, "xmax": 702986.5364999995, "ymax": 672312.7280000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "DryWellID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "DryWellID", "type": "esriFieldTypeString", "alias": "Dry Well ID", "length": 20, "domain": null }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "BottomElevation", "type": "esriFieldTypeSingle", "alias": "Bottom Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1317Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1317Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1317DryWellID", "fields": "DryWellID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S590_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918840000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 320, "name": "French Drain", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "f0258ffb3fbae43c57e2cbfd2aace83f", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674517.2325000018, "ymin": 645753.3980000019, "xmax": 704373.2705000006, "ymax": 678276.2480000034, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "FrenchDrainID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "FrenchDrainID", "type": "esriFieldTypeString", "alias": "French Drain ID", "length": 20, "domain": null }, { "name": "CoverSize", "type": "esriFieldTypeDouble", "alias": "Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1306Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1306Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1306FrenchDrain", "fields": "FrenchDrainID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S579_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918781000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 330, "name": "Storm Manhole", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "74bc710ff1a41d6af1b32a1a546c1afd", "imageData": "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", "contentType": "image/png", "width": 14, "height": 14, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673272.8154999986, "ymin": 638864.5090000033, "xmax": 706473.2025000006, "ymax": 689779.2459999993, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "ManholeID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ManholeID", "type": "esriFieldTypeString", "alias": "Manhole ID", "length": 20, "domain": null }, { "name": "ManholeDiameter", "type": "esriFieldTypeSmallInteger", "alias": "Manhole Diameter (ft.)", "domain": { "type": "codedValue", "name": "WS2_UTIL Manhole Diameter", "description": "Valid utility manhole diameter values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "7", "code": 7 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "3", "code": 3 }, { "name": "5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeCoverSize", "type": "esriFieldTypeDouble", "alias": "Manhole Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeType", "type": "esriFieldTypeString", "alias": "Manhole Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Manhole Type", "description": "Valid storm manhole type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 5", "code": "Type 5" }, { "name": "CDS", "code": "CDS" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "OutletElevation", "type": "esriFieldTypeSingle", "alias": "Outlet Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "LastInspectDate", "type": "esriFieldTypeDate", "alias": "Last Inspect Date", "length": 8, "domain": null }, { "name": "LastDateCleaned", "type": "esriFieldTypeDate", "alias": "Last Date Cleaned", "length": 8, "domain": null }, { "name": "NeedCleaning", "type": "esriFieldTypeString", "alias": "Need Cleaning", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1310Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeType", "fields": "ManholeType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeDiam", "fields": "ManholeDiameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeID", "fields": "ManholeID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S583_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918801000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 340, "name": "Inlet Box", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "e9b4a3e243aebc0d191500844e98300c", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAsAAAASCAYAAACNdSR1AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABAUlEQVQokZ3SMU6EQBTG8VEYkYwxwRi7bTSxNJZwC+IZ6GjopOAQdISahnKOwQmoCXFiyCygZhJZlMGsFcNLjLuv/uWfr3g6OuD0Y/AZQujpD5cv8aWu689xHF9gjMkCzVEUYc65gpFlWe++7z+uk2mavnHO1c3DMNzk+W9Aua7r9hNVPM+zJoQAWEp5ArBpmq+e592vcZIku7quwYxrSiko932PQXmapvOqqgAex/EUYELISxAEd2ucZdmOMaZiIcRtGIagzBgzQdkwjK3rups1ppR+NU2jYozxh23boEwI+Qbltm0fHMf51DRNea6yLMGMrZTyqigKUF7eUS/6r/sB/RRhpJ5ibC0AAAAASUVORK5CYII=", "contentType": "image/png", "width": 8, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.Rotate", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674257.7529999986, "ymin": 639332.3095000014, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "InletBoxID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "InletBoxID", "type": "esriFieldTypeString", "alias": "Inlet Box ID", "length": 20, "domain": null }, { "name": "InletBoxType", "type": "esriFieldTypeString", "alias": "Inlet Box Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Inlet Box Type", "description": "Valid storm inlet box type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 2", "code": "Type 2" }, { "name": "Type 3", "code": "Type 3" }, { "name": "Type 4", "code": "Type 4" }, { "name": "Type 5", "code": "Type 5" }, { "name": "Type 8", "code": "Type 8" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "GrateElevation", "type": "esriFieldTypeSingle", "alias": "Grate Elevation (ft.)", "domain": null }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Rotate", "type": "esriFieldTypeSmallInteger", "alias": "Rotate", "domain": { "type": "range", "name": "WS2_CIF Rotate", "description": "Valid rotate values", "range": [ 0, 360 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SideOpenerBlocked", "type": "esriFieldTypeString", "alias": "Side Opener Blocked", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1312Rotate", "fields": "Rotate", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxTyp", "fields": "InletBoxType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxID", "fields": "InletBoxID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S585_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918812000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 350, "name": "Catch Basin", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "59ad5d42e1c5f92107329d7cf015766b", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAsAAAASCAYAAACNdSR1AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABDUlEQVQokWNhIAGwkKOYjYGBIQiPuhXIivlYmBjLixOteFiYmbhhKv7/Z/g/beUZ1g+fvqMoZuDlZf8Y5q5tgG7k+j3XP3z49B3Vzb9+/hXbefQuhv0fv/4AORFV8T8GBubvP35jKP737z8jhmIOdpbnAc4aauiK1+y+9vPFm6/ozvgjcuD0AwyTP339xYph8t//DBzPXn3GUPz7z18mDMWcHCxPorx1ldEVbzt8++ert2jO+Pb9l9LkpacwTH719isnhsmsrMxvHMwUZNEV7z/94Pfbj2jhzMrC9ElXVQzDZC52lj8YJn/49FMvoXrjd2Zm1MR198l7DGe8+f//v9Dl2y8xTEYGZCVRogAAN1Nj4ZCbkk0AAAAASUVORK5CYII=", "contentType": "image/png", "width": 8, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.Rotate", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674257.7529999986, "ymin": 639332.3095000014, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "InletBoxID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "InletBoxID", "type": "esriFieldTypeString", "alias": "Inlet Box ID", "length": 20, "domain": null }, { "name": "InletBoxType", "type": "esriFieldTypeString", "alias": "Inlet Box Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Inlet Box Type", "description": "Valid storm inlet box type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 2", "code": "Type 2" }, { "name": "Type 3", "code": "Type 3" }, { "name": "Type 4", "code": "Type 4" }, { "name": "Type 5", "code": "Type 5" }, { "name": "Type 8", "code": "Type 8" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "GrateElevation", "type": "esriFieldTypeSingle", "alias": "Grate Elevation (ft.)", "domain": null }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Rotate", "type": "esriFieldTypeSmallInteger", "alias": "Rotate", "domain": { "type": "range", "name": "WS2_CIF Rotate", "description": "Valid rotate values", "range": [ 0, 360 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SideOpenerBlocked", "type": "esriFieldTypeString", "alias": "Side Opener Blocked", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1312Rotate", "fields": "Rotate", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxTyp", "fields": "InletBoxType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxID", "fields": "InletBoxID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S585_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918812000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 360, "name": "Storm Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner = 'Private'", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 137, 112, 68, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 673209.5789999999, "ymin": 638864.5090000033, "xmax": 706481.7875000015, "ymax": 687807.9514999986, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "FlowType", "type": "esriFieldTypeString", "alias": "Flow Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Flow Type", "description": "Valid storm flow type values", "codedValues": [ { "name": "Gravity", "code": "Gravity" }, { "name": "Pressure", "code": "Pressure" }, { "name": "Siphon", "code": "Siphon" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "range", "name": "WS2_STM Line Diameter", "description": "Valid storm line diameter values", "range": [ 2, 74 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "UpInvertElevation", "type": "esriFieldTypeSingle", "alias": "Up Invert Elevation (ft.)", "domain": null }, { "name": "DownInvertElevation", "type": "esriFieldTypeSingle", "alias": "Down Invert Elevation (ft.)", "domain": null }, { "name": "Slope", "type": "esriFieldTypeDouble", "alias": "Slope", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "Collector_ID", "type": "esriFieldTypeString", "alias": "Collector ID", "length": 20, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1318Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318FlowType", "fields": "FlowType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S591_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918845000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 370, "name": "Other Conveyance", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 677344.1585000008, "ymin": 645960.25, "xmax": 704293.2369999997, "ymax": 683598.9940000027, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "MethodOfConveyance", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "MethodOfConveyance", "type": "esriFieldTypeString", "alias": "Method of Conveyance", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Method of Conveyance", "description": "Valid storm method of conveyance values", "codedValues": [ { "name": "Storm Tunnel", "code": "Storm Tunnel" }, { "name": "Open Channel", "code": "Open Channel" }, { "name": "Underground Channel", "code": "Underground Channel" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1307Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1307Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1307MethodOfCon", "fields": "MethodOfConveyance", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S580_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918786000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 400, "name": "Electric", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 410, "name": "Transformer" }, { "id": 420, "name": "Streetlight" }, { "id": 430, "name": "Secondary Conductor" }, { "id": 440, "name": "Primary Conductor" }, { "id": 450, "name": "Electric/Fiber Conduit" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 643690.5494070798, "ymin": 639229.2276111543, "xmax": 707061.4210246615, "ymax": 695982.9940246567, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 410, "name": "Transformer", "type": "Feature Layer", "description": "
These are features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>",
"geometryType": "esriGeometryPoint",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
},
"copyrightText": "",
"parentLayer": {
"id": 400,
"name": "Electric"
},
"subLayers": [],
"minScale": 5000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriPMS",
"url": "ae8742f85343d434cc5e67cc5c21356d",
"imageData": "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",
"contentType": "image/png",
"width": 17,
"height": 16,
"angle": 0,
"xoffset": 0,
"yoffset": 0
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 643690.5494070798,
"ymin": 639234.0107380748,
"xmax": 707061.4210246615,
"ymax": 688815.7550783232,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "assetgroup",
"typeIdField": "ASSETGROUP",
"subtypeFieldName": "ASSETGROUP",
"subtypeField": "ASSETGROUP",
"defaultSubtypeCode": 0,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "ASSETGROUP",
"type": "esriFieldTypeInteger",
"alias": "Asset Group",
"domain": null
},
{
"name": "ASSETTYPE",
"type": "esriFieldTypeSmallInteger",
"alias": "Asset Type",
"domain": null
},
{
"name": "lifecyclestatus",
"type": "esriFieldTypeSmallInteger",
"alias": "Lifecycle Status",
"domain": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status_Combined",
"description": "Bitwise combination of lifecycle states for subnetwork management",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Proposed and In Service",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "In Service and Planned Removal",
"code": 6
},
{
"name": "Maintenance",
"code": 7
},
{
"name": "Design",
"code": 11
},
{
"name": "Abandoned",
"code": 12
},
{
"name": "Removed",
"code": 13
},
{
"name": "Retired",
"code": 14
},
{
"name": "NA",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S182_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tertiarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Ground",
"code": 0
},
{
"name": "Bound",
"code": 31
},
{
"name": "Rod",
"code": 32
},
{
"name": "Voltage Grid",
"code": 33
},
{
"name": "Stray Voltage Isolator",
"code": 34
},
{
"name": "Grounding Switch",
"code": 35
},
{
"name": "Cross Bond",
"code": 36
},
{
"name": "Ground Plate",
"code": 37
},
{
"name": "Ground Joint",
"code": 38
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Type",
"description": "Ground Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bound",
"code": 1
},
{
"name": "Mesh",
"code": 2
},
{
"name": "Rod",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 1,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit",
"description": "High Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor HV",
"code": 41
},
{
"name": "Switch and Breaker HV",
"code": 42
},
{
"name": "Voltage Regulator HV",
"code": 43
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 3,
"name": "High Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation",
"description": "High Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery HV",
"code": 61
},
{
"name": "Biomass HV",
"code": 62
},
{
"name": "Coal HV",
"code": 63
},
{
"name": "Gas Turbine HV",
"code": 64
},
{
"name": "Geothermal HV",
"code": 65
},
{
"name": "Hydro HV",
"code": 66
},
{
"name": "Nuclear HV",
"code": 67
},
{
"name": "Photovoltaic Solar HV",
"code": 68
},
{
"name": "Thermal Solar HV",
"code": 69
},
{
"name": "Wind HV",
"code": 70
},
{
"name": "AC Wave HV",
"code": 71
},
{
"name": "Generator HV",
"code": 72
},
{
"name": "Interconnect HV",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 4,
"name": "High Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse",
"description": "High Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Station Disconnect Fuse HV",
"code": 581
},
{
"name": "AC Station Load Break Fuse HV",
"code": 582
},
{
"name": "AC Load Break Disconnect Fuse HV",
"code": 583
},
{
"name": "AC Load Break Fuse HV - Controller",
"code": 584
},
{
"name": "AC Disconnect Fuse HV - Controller",
"code": 585
},
{
"name": "AC Load Break Disconnect Fuse HV - Controller",
"code": 586
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Continuous Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "3000 A",
"code": 3000
},
{
"name": "6000 A",
"code": 6000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "60 kA",
"code": 60000
},
{
"name": "80 kA",
"code": 80000
},
{
"name": "90 kA",
"code": 90000
},
{
"name": "2 kA",
"code": 2000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 43,
"name": "High Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay",
"description": "High Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator HV",
"code": 80
},
{
"name": "Instrument Transformer HV",
"code": 81
},
{
"name": "Load Monitor HV",
"code": 82
},
{
"name": "Relay HV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Phase_Angle_Offset_Range",
"description": "Phase Offset values 0 - 60",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 5,
"name": "High Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion",
"description": "High Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Inverter HV",
"code": 101
},
{
"name": "Rectifier HV",
"code": 102
},
{
"name": "Bidirectional HV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_DC_Voltage",
"description": "Valid High Voltage Direct Current Voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "270 kV",
"code": 270000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1000 kV",
"code": 1000000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
},
{
"name": "1400 kV",
"code": 1400000
},
{
"name": "1500 kV",
"code": 1500000
},
{
"name": "1800 kV",
"code": 1800000
},
{
"name": "2500 kV",
"code": 2500000
},
{
"name": "3000 kV",
"code": 3000000
},
{
"name": "4000 kV",
"code": 4000000
},
{
"name": "5000 kV",
"code": 5000000
},
{
"name": "6000 kV",
"code": 6000000
},
{
"name": "6400 kV",
"code": 6400000
},
{
"name": "7200 kV",
"code": 7200000
},
{
"name": "8000 kV",
"code": 8000000
},
{
"name": "10000 kV",
"code": 10000000
},
{
"name": "12000 kV",
"code": 12000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 6,
"name": "High Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting",
"description": "High Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Capacitor HV",
"code": 121
},
{
"name": "AC Wave Trap HV",
"code": 122
},
{
"name": "AC Reactor HV",
"code": 123
},
{
"name": "DC Capacitor HV",
"code": 124
},
{
"name": "DC Reactor HV",
"code": 125
},
{
"name": "Synchronous Condenser HV",
"code": 126
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Power_Factor_Correcting_Type",
"description": "Type of Power Factor Correcting Equipment",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 7,
"name": "High Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator",
"description": "High Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase HV",
"code": 171
},
{
"name": "AC Three Phase HV",
"code": 172
},
{
"name": "DC Regulator HV",
"code": 173
},
{
"name": "Frequency Converter HV",
"code": 174
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 8,
"name": "High Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service",
"description": "High Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "AC Metering HV",
"code": 161
},
{
"name": "DC Metering HV",
"code": 162
},
{
"name": "High Voltage Premise HV",
"code": 163
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 9,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch",
"description": "High Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Circuit Breaker HV",
"code": 181
},
{
"name": "AC Disconnect HV",
"code": 182
},
{
"name": "AC Switchgear HV",
"code": 183
},
{
"name": "DC Circuit Breaker HV",
"code": 184
},
{
"name": "DC Disconnect HV",
"code": 185
},
{
"name": "DC Switchgear HV",
"code": 186
},
{
"name": "AC Bus Tie Breaker HV",
"code": 187
},
{
"name": "DC Bus Tie Breaker HV",
"code": 188
},
{
"name": "AC Disconnect - Grounded HV",
"code": 189
},
{
"name": "AC Breaker Bypass HV",
"code": 190
},
{
"name": "AC Circuit Breaker HV - Controller",
"code": 191
},
{
"name": "AC Station Disconnect HV",
"code": 192
},
{
"name": "AC Station Load Break Disconnect HV - Controller",
"code": 193
},
{
"name": "DC Circuit Breaker HV - Controller",
"code": 194
},
{
"name": "AC Disconnect HV - Controller",
"code": 195
},
{
"name": "AC Grounding HV",
"code": 196
},
{
"name": "AC Thyristor HV",
"code": 197
},
{
"name": "DC Thyristor HV",
"code": 198
},
{
"name": "AC Transfer Switch HV",
"code": 199
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps",
"description": "High Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".6 kA",
"code": 600
},
{
"name": "1.2 kA",
"code": 1200
},
{
"name": "1.25 kA",
"code": 1250
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 10,
"name": "High Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer",
"description": "High Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "AC Single Phase - HV->MV",
"code": 201
},
{
"name": "AC Three Phase - HV->MV",
"code": 202
},
{
"name": "DC Power - HV->HV",
"code": 203
},
{
"name": "Grounding Transformer - HV->MV",
"code": 204
},
{
"name": "Station - HV->MV",
"code": 205
},
{
"name": "Station Three Winding - HV->HV-HV",
"code": 206
},
{
"name": "Station Three Winding - HV->HV-MV",
"code": 207
},
{
"name": "Phase Control - HV->HV",
"code": 208
},
{
"name": "Station Three Winding - HV->HV-LV",
"code": 209
},
{
"name": "Station Step Up - MV->HV",
"code": 210
},
{
"name": "Station Step - HV->HV",
"code": 211
},
{
"name": "Station Three Winding - HV->MV-MV",
"code": 212
},
{
"name": "Station Three Winding - HV->MV-LV",
"code": 213
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 11,
"name": "High Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Line Hardware",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 61,
"name": "High Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding HV",
"code": 871
},
{
"name": "DC Transformer Winding HV",
"code": 872
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 48,
"name": "High Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker",
"description": "Medium Voltage Circuit Breaker",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "Isolator Switch MV",
"code": 501
},
{
"name": "Single Phase Circuit Breaker MV",
"code": 502
},
{
"name": "Three Phase Circuit Breaker MV",
"code": 503
},
{
"name": "Single Phase Circuit Breaker MV - Controller",
"code": 512
},
{
"name": "Three Phase Circuit Breaker MV - Controller",
"code": 513
},
{
"name": "Network Protector MV",
"code": 515
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Medium Voltage Circuit Breaker Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "1250 A",
"code": 1250
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "2500 A",
"code": 2500
},
{
"name": "3000 A",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 26,
"name": "Medium Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit",
"description": "Medium Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor MV",
"code": 521
},
{
"name": "Circuit Breaker MV",
"code": 522
},
{
"name": "Recloser MV",
"code": 523
},
{
"name": "Transfer Switch Controller MV",
"code": 524
},
{
"name": "Regulator MV",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 27,
"name": "Medium Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow",
"description": "Medium Voltage Elbow",
"codedValues": [
{
"name": "Elbow",
"code": 0
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Load Break Feedthru MV",
"code": 541
},
{
"name": "Load Break Junction MV",
"code": 542
},
{
"name": "Single Phase Dead Break MV",
"code": 543
},
{
"name": "Single Phase Load Break MV",
"code": 544
},
{
"name": "Three Phase Dead Break MV",
"code": 545
},
{
"name": "Three Phase Load Break MV",
"code": 546
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 28,
"name": "Medium Voltage Elbow"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse",
"description": "Medium Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Bayonet Fuse MV",
"code": 561
},
{
"name": "Fault Limiter Fuse MV",
"code": 562
},
{
"name": "Indoor Fuse MV",
"code": 563
},
{
"name": "Overhead Cutout Disconnect Fuse MV",
"code": 564
},
{
"name": "Overhead Cutout Load Break Fuse MV",
"code": 565
},
{
"name": "Overhead Cutout Sectionalizer Fuse MV",
"code": 566
},
{
"name": "Overhead Cutout Solid Blade Fuse MV",
"code": 567
},
{
"name": "Cabinet Fuse MV",
"code": 568
},
{
"name": "Underground Fuse MV",
"code": 569
},
{
"name": "Underground Disconnect Fuse MV",
"code": 570
},
{
"name": "Underground Load Break Fuse MV",
"code": 571
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV",
"code": 572
},
{
"name": "Overhead Cutout Load Break Fuse MV - Controller",
"code": 573
},
{
"name": "Overhead Cutout Disconnect Fuse MV - Controller",
"code": 574
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller",
"code": 575
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Rating",
"description": "List of valid Electric Medium Voltage Fuse Ratingsl",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "E",
"code": 2
},
{
"name": "R",
"code": 3
},
{
"name": "PT",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Type",
"description": "Medium Voltage fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridged",
"code": 1
},
{
"name": "Burndy",
"code": 2
},
{
"name": "Bussman",
"code": 3
},
{
"name": "Cooper Elf",
"code": 4
},
{
"name": "D & W",
"code": 5
},
{
"name": "EJO-1",
"code": 6
},
{
"name": "Fault Tamer",
"code": 7
},
{
"name": "Kearney",
"code": 8
},
{
"name": "Kearney 200",
"code": 9
},
{
"name": "Kearney QA",
"code": 10
},
{
"name": "RTE B",
"code": 11
},
{
"name": "S & C",
"code": 12
},
{
"name": "S & C SM-4",
"code": 13
},
{
"name": "X-Limiter",
"code": 14
},
{
"name": "NX",
"code": 15
},
{
"name": "CL",
"code": 16
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 29,
"name": "Medium Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation",
"description": "Medium Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "AC Wave MV",
"code": 110
},
{
"name": "Battery MV",
"code": 111
},
{
"name": "Biomass MV",
"code": 112
},
{
"name": "Generator MV",
"code": 113
},
{
"name": "Gas Turbine MV",
"code": 114
},
{
"name": "Geothermal MV",
"code": 115
},
{
"name": "Hydro MV",
"code": 116
},
{
"name": "Wind MV",
"code": 117
},
{
"name": "Photovoltaic Solar MV",
"code": 118
},
{
"name": "Thermal Solar MV",
"code": 119
},
{
"name": "Interconnect MV",
"code": 120
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 30,
"name": "Medium Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay",
"description": "Medium Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator MV",
"code": 601
},
{
"name": "Instrument Transformer MV",
"code": 602
},
{
"name": "Programmable Logic Unit MV",
"code": 603
},
{
"name": "Remote Terminal Unit MV",
"code": 604
},
{
"name": "SCADA Load Monitor MV",
"code": 605
},
{
"name": "SCADA Weather Station MV",
"code": 606
},
{
"name": "Relay MV",
"code": 607
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 31,
"name": "Medium Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump",
"description": "Medium Voltage Motor and Pump",
"codedValues": [
{
"name": "Motor and Pump",
"code": 0
},
{
"name": "Single Phase Motor MV",
"code": 621
},
{
"name": "Single Phase Pump MV",
"code": 622
},
{
"name": "Three Phase Motor MV",
"code": 623
},
{
"name": "Three Phase Pump MV",
"code": 624
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 32,
"name": "Medium Voltage Motor and Pump"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion",
"description": "Medium Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter MV",
"code": 641
},
{
"name": "Single Phase Rectifier MV",
"code": 642
},
{
"name": "Three Phase Inverter MV",
"code": 643
},
{
"name": "Three Phase Rectifier MV",
"code": 644
},
{
"name": "Single Phase Bidirectional MV",
"code": 645
},
{
"name": "Three Phase Bidirectional MV",
"code": 646
},
{
"name": "Wave Trap MV",
"code": 647
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 33,
"name": "Medium Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting",
"description": "Medium Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Mobile Capacitor MV",
"code": 661
},
{
"name": "Overhead Single Phase Capacitor MV",
"code": 664
},
{
"name": "Overhead Three Phase Capacitor MV",
"code": 665
},
{
"name": "Overhead Harmonic Filter MV",
"code": 666
},
{
"name": "Overhead Reactor MV",
"code": 667
},
{
"name": "Pad Mounted Single Phase Capacitor MV",
"code": 668
},
{
"name": "Pad Mounted Three Phase Capacitor MV",
"code": 669
},
{
"name": "Mobile Harmonic Filter MV",
"code": 671
},
{
"name": "Mobile Reactor MV",
"code": 672
},
{
"name": "Pad Mounted Harmonic Filter MV",
"code": 673
},
{
"name": "Pad Mounted Reactor MV",
"code": 674
},
{
"name": "Station Capacitor MV",
"code": 675
},
{
"name": "Station Harmonic Filter MV",
"code": 676
},
{
"name": "Station Reactor MV",
"code": 677
},
{
"name": "Synchronous Condenser MV",
"code": 678
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 34,
"name": "Medium Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator",
"description": "Medium Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Overhead Single Phase VR MV",
"code": 681
},
{
"name": "Overhead Three Phase VR MV",
"code": 683
},
{
"name": "Pad Mounted Single Phase VR MV",
"code": 685
},
{
"name": "Pad Mounted Three Phase VR MV",
"code": 687
},
{
"name": "Frequency Converter MV",
"code": 688
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 35,
"name": "Medium Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service",
"description": "Medium Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Primary Meter - Industrial Customer MV",
"code": 701
},
{
"name": "Primary Meter - Utility Customer MV",
"code": 702
},
{
"name": "Primary Meter Circuit Source MV",
"code": 703
},
{
"name": "Medium Voltage Premise MV",
"code": 704
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 36,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser",
"description": "Medium Voltage Recloser Asset Types",
"codedValues": [
{
"name": "Recloser",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Recloser MV",
"code": 730
},
{
"name": "Overhead Three Phase Recloser MV - Controller",
"code": 734
},
{
"name": "Pad Mounted Three Phase Recloser MV - Controller",
"code": 738
},
{
"name": "Overhead Three Phase Recloser MV",
"code": 744
},
{
"name": "Pad Mounted Single Phase Recloser MV",
"code": 747
},
{
"name": "Pad Mounted Three Phase Recloser MV",
"code": 748
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps",
"description": "Medium Voltage Recloser Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "280 A",
"code": 280
},
{
"name": "400 A",
"code": 400
},
{
"name": "560 A",
"code": 560
},
{
"name": "600 A",
"code": 600
},
{
"name": "630 A",
"code": 630
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 41,
"name": "Medium Voltage Recloser"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer",
"description": "Medium Voltage Secitionalizer",
"codedValues": [
{
"name": "Sectionalizer",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Sectionalizer MV",
"code": 731
},
{
"name": "Overhead Three Phase Sectionalizer MV",
"code": 745
},
{
"name": "Pad Mounted Single Phase Sectionalizer MV",
"code": 749
},
{
"name": "Pad Mounted Three Phase Sectionalizer MV",
"code": 750
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 42,
"name": "Medium Voltage Sectionalizer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch",
"description": "Medium Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Cabinet Bypass MV",
"code": 721
},
{
"name": "Cabinet Switch MV",
"code": 722
},
{
"name": "Cabinet Switch - Grounded MV",
"code": 723
},
{
"name": "Overhead Bypass MV",
"code": 724
},
{
"name": "Overhead Grounding Switch MV",
"code": 725
},
{
"name": "Overhead Jumper MV",
"code": 726
},
{
"name": "Station Grounding MV",
"code": 727
},
{
"name": "Overhead Single Phase Disconnect MV",
"code": 728
},
{
"name": "Overhead Single Phase Load Break MV",
"code": 729
},
{
"name": "Overhead Three Phase Disconnect MV",
"code": 732
},
{
"name": "Overhead Three Phase Load Break MV",
"code": 733
},
{
"name": "Pad Mounted Fault Interrupter MV",
"code": 746
},
{
"name": "Station Single Phase Disconnect MV",
"code": 751
},
{
"name": "Station Disconnect MV",
"code": 752
},
{
"name": "T Blade MV",
"code": 753
},
{
"name": "V Blade MV",
"code": 754
},
{
"name": "Underground Single Phase Disconnect MV",
"code": 755
},
{
"name": "Underground Single Phase Load Break MV",
"code": 758
},
{
"name": "Underground Three Phase Disconnect MV",
"code": 759
},
{
"name": "Underground Three Phase Load Break MV",
"code": 760
},
{
"name": "Underground Transfer Switch MV",
"code": 761
},
{
"name": "Bus Tie Breaker MV",
"code": 765
},
{
"name": "Station Load Break MV",
"code": 766
},
{
"name": "Station Disconnect - Grounded MV",
"code": 768
},
{
"name": "Station Load Break Disconnect MV",
"code": 769
},
{
"name": "Station Disconnect MV - Controller",
"code": 770
},
{
"name": "Station Load Break MV - Controller",
"code": 771
},
{
"name": "Station Load Break Disconnect MV - Controller",
"code": 772
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps",
"description": "Medium Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "900 A",
"code": 900
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 37,
"name": "Medium Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer",
"description": "Medium Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Grounding Transformer - MV->MV",
"code": 781
},
{
"name": "Mobile Single Phase - MV->LV",
"code": 782
},
{
"name": "Mobile Three Phase - MV->LV",
"code": 783
},
{
"name": "Network - MV->LV",
"code": 784
},
{
"name": "Overhead Single Phase - MV->LV",
"code": 785
},
{
"name": "Station - MV->LV",
"code": 786
},
{
"name": "Station Three Winding - MV->LV-LV",
"code": 787
},
{
"name": "Overhead Three Phase - MV->LV",
"code": 788
},
{
"name": "Pad Mounted Single Phase - MV->LV",
"code": 789
},
{
"name": "Station Three Winding - MV->MV-LV",
"code": 790
},
{
"name": "Pad Mounted Three Phase - MV->LV",
"code": 792
},
{
"name": "Submersible Single Phase - MV->LV",
"code": 793
},
{
"name": "Submersible Three Phase - MV->LV",
"code": 794
},
{
"name": "Overhead Open Delta - MV->LV",
"code": 795
},
{
"name": "Overhead Open Wye - MV->LV",
"code": 796
},
{
"name": "Pad Mounted Open Delta - MV->LV",
"code": 797
},
{
"name": "Pad Mounted Open Wye - MV->LV",
"code": 798
},
{
"name": "Overhead Single Phase Step - MV<->MV",
"code": 801
},
{
"name": "Overhead Three Phase Step - MV<->MV",
"code": 802
},
{
"name": "Overhead Single Phase Step - MV->MV",
"code": 803
},
{
"name": "Overhead Three Phase Step - MV->MV",
"code": 804
},
{
"name": "Pad Mounted Single Phase Step - MV<->MV",
"code": 805
},
{
"name": "Pad Mounted Three Phase Step - MV<->MV",
"code": 806
},
{
"name": "Pad Mounted Single Phase Step - MV->MV",
"code": 807
},
{
"name": "Pad Mounted Three Phase Step - MV->MV",
"code": 808
},
{
"name": "Submersible Single Phase Step - MV<->MV",
"code": 809
},
{
"name": "Overhead Three Phase Wye Delta Closed Ground",
"code": 810
},
{
"name": "Submersible Single Phase Step - MV->MV",
"code": 811
},
{
"name": "Pad Mounted Three Phase Wye Delta Closed Ground",
"code": 812
},
{
"name": "Station Step - MV->MV",
"code": 813
},
{
"name": "Station Step - MV<->MV",
"code": 814
},
{
"name": "Station Step Three Winding - MV->MV-MV",
"code": 815
},
{
"name": "Overhead Three Phase Step Up - LV->MV",
"code": 816
},
{
"name": "Overhead Three Phase Step Up - LV<->MV",
"code": 817
},
{
"name": "Station Step Up - LV->MV",
"code": 818
},
{
"name": "Station Step Up - LV<->MV",
"code": 819
},
{
"name": "Pad Mounted Three Phase Step Up - LV->MV",
"code": 820
},
{
"name": "Pad Mounted Three Phase Step Up - LV<->MV",
"code": 821
},
{
"name": "Overhead Single Phase Step Up - LV->MV",
"code": 822
},
{
"name": "Overhead Single Phase Step Up - LV<->MV",
"code": 823
},
{
"name": "Pad Mounted Single Phase Step Up - LV->MV",
"code": 824
},
{
"name": "Pad Mounted Single Phase Step Up - LV<->MV",
"code": 825
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 38,
"name": "Medium Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 62,
"name": "Medium Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "Transformer Winding MV",
"code": 873
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 47,
"name": "Medium Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker",
"description": "Asset Types for Low Voltage Circuit Breakers",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Circuit Breaker LV",
"code": 471
},
{
"name": "DC Circuit Breaker LV",
"code": 472
},
{
"name": "AC Circuit Breaker LV - Controller",
"code": 473
},
{
"name": "DC Circuit Breaker LV - Controller",
"code": 474
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Low Voltage Circuit Breaker Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 40,
"name": "Low Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit",
"description": "Low Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Control Unit LV",
"code": 241
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 13,
"name": "Low Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse",
"description": "Low Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "Service Fuse Load Break LV",
"code": 259
},
{
"name": "Service Fuse Disconnect LV",
"code": 260
},
{
"name": "AC Overhead Fuse LV",
"code": 261
},
{
"name": "AC Underground Fuse LV",
"code": 262
},
{
"name": "DC Overhead Fuse LV",
"code": 263
},
{
"name": "DC Underground Fuse LV",
"code": 264
},
{
"name": "AC Overhead Load Break Fuse LV",
"code": 265
},
{
"name": "AC Overhead Fuse LV - Controller",
"code": 266
},
{
"name": "AC Underground Load Break Fuse LV",
"code": 267
},
{
"name": "AC Underground Fuse LV - Controller",
"code": 268
},
{
"name": "DC Overhead Fuse LV - Controller",
"code": 269
},
{
"name": "DC Underground Fuse LV - Controller",
"code": 270
},
{
"name": "AC Overhead Cutout Load Break Disconnect Fuse LV",
"code": 271
},
{
"name": "AC Overhead Cutout Load Break Fuse LV - Controller",
"code": 272
},
{
"name": "AC Overhead Cutout Disconnect Fuse LV - Controller",
"code": 273
},
{
"name": "AC Overhead Cutout Load Break Fuse LV",
"code": 274
},
{
"name": "Station Disconnect Fuse LV",
"code": 275
},
{
"name": "Station Load Break Fuse LV",
"code": 276
},
{
"name": "Station Load Break Disconnect Fuse LV",
"code": 277
},
{
"name": "Station Disconnect Fuse LV - Controller",
"code": 278
},
{
"name": "Station Load Break Fuse LV - Controller",
"code": 279
},
{
"name": "Station Load Break Disconnect Fuse LV - Controller",
"code": 280
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Type",
"description": "List of valid fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Link_Type",
"description": "Types of fuse links",
"codedValues": [
{
"name": "K",
"code": 10
},
{
"name": "T",
"code": 11
},
{
"name": "MS",
"code": 12
},
{
"name": "QH",
"code": 13
},
{
"name": "Standard",
"code": 14
},
{
"name": "SloFast",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 14,
"name": "Low Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation",
"description": "Low Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery LV",
"code": 281
},
{
"name": "Generator LV",
"code": 283
},
{
"name": "Residential Photovoltaic Solar LV",
"code": 284
},
{
"name": "Wind Turbine LV",
"code": 285
},
{
"name": "AC Wave LV",
"code": 286
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 15,
"name": "Low Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting",
"description": "Low Voltage Lighting",
"codedValues": [
{
"name": "Lighting",
"code": 0
},
{
"name": "Floodlight LV",
"code": 301
},
{
"name": "Streetlight LV",
"code": 302
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Light_Housing_Type",
"description": "Light Housing Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cobra Head",
"code": 1
},
{
"name": "Security",
"code": 2
},
{
"name": "Roadway",
"code": 3
},
{
"name": "Flood",
"code": 4
},
{
"name": "Decorative",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Street_Bulb_Type",
"description": "List of valid bulb types for streetlights",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "High Pressure Sodium (HPS)",
"code": 30
},
{
"name": "Low Pressure Sodium (LPS)",
"code": 31
},
{
"name": "Metal Halide (MH)",
"code": 32
},
{
"name": "Mercury Vapor (MV)",
"code": 33
},
{
"name": "Halogen (HG)",
"code": 34
},
{
"name": "Light Emitting Diode (LED)",
"code": 35
},
{
"name": "Phosphor-Converted Amber LED (PCA)",
"code": 36
},
{
"name": "Narrow-Band Amber LED (NBA)",
"code": 37
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"lightsphotoeye": {"type": "inherited"},
"lightswattage": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 16,
"name": "Low Voltage Lighting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay",
"description": "Low Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator LV",
"code": 321
},
{
"name": "Load Monitor LV",
"code": 322
},
{
"name": "Relay LV",
"code": 323
},
{
"name": "Instrument Transformer LV",
"code": 324
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 17,
"name": "Low Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor",
"description": "Low Voltage Motor",
"codedValues": [
{
"name": "Motor",
"code": 0
},
{
"name": "Single Phase Motor LV",
"code": 341
},
{
"name": "Three Phase Motor LV",
"code": 342
},
{
"name": "DC Motor LV",
"code": 343
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 18,
"name": "Low Voltage Motor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection",
"description": "Low Voltage Network Protection",
"codedValues": [
{
"name": "Network Protector",
"code": 0
},
{
"name": "Network Protector LV",
"code": 361
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 19,
"name": "Low Voltage Network Protection"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion",
"description": "Low Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter LV",
"code": 381
},
{
"name": "Single Phase Rectifier LV",
"code": 382
},
{
"name": "Three Phase Inverter LV",
"code": 383
},
{
"name": "Three Phase Rectifier LV",
"code": 384
},
{
"name": "Single Phase Bidirectional LV",
"code": 386
},
{
"name": "Three Phase Bidirectional LV",
"code": 387
},
{
"name": "Wave Trap LV",
"code": 390
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 20,
"name": "Low Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting",
"description": "Low Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "Mobile Harmonic Filter LV",
"code": 401
},
{
"name": "Mobile Reactor LV",
"code": 402
},
{
"name": "Overhead Capacitor LV",
"code": 403
},
{
"name": "Overhead Harmonic Filter LV",
"code": 404
},
{
"name": "Overhead Reactor LV",
"code": 405
},
{
"name": "Pad Mounted Capacitor LV",
"code": 406
},
{
"name": "Pad Mounted Harmonic Filter LV",
"code": 407
},
{
"name": "Pad Mounted Reactor LV",
"code": 408
},
{
"name": "Station Capacitor LV",
"code": 409
},
{
"name": "Station Harmonic Filter LV",
"code": 410
},
{
"name": "Station Reactor LV",
"code": 411
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 21,
"name": "Low Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service",
"description": "Low Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Single Phase Commercial LV",
"code": 421
},
{
"name": "Single Phase Residential LV",
"code": 422
},
{
"name": "Three Phase Commercial LV",
"code": 423
},
{
"name": "Three Phase Residential LV",
"code": 424
},
{
"name": "Unmetered Load LV",
"code": 425
},
{
"name": "DC Commercial LV",
"code": 426
},
{
"name": "Low Voltage Premise LV",
"code": 427
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 22,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch",
"description": "Low Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Station Disconnect LV",
"code": 431
},
{
"name": "AC Station Load Break LV",
"code": 432
},
{
"name": "AC Station Load Break Disconnect LV",
"code": 433
},
{
"name": "AC Station Disconnect LV - Controller",
"code": 434
},
{
"name": "AC Station Load Break LV - Controller",
"code": 435
},
{
"name": "AC Station Load Break Disconnect LV - Controller",
"code": 436
},
{
"name": "Overhead AC Load Break LV",
"code": 441
},
{
"name": "Overhead AC Disconnect LV",
"code": 442
},
{
"name": "Overhead DC Load Break LV",
"code": 443
},
{
"name": "Overhead DC Disconnect LV",
"code": 444
},
{
"name": "Underground AC Load Break LV",
"code": 445
},
{
"name": "Underground AC Disconnect LV",
"code": 446
},
{
"name": "Underground DC Load Break LV",
"code": 447
},
{
"name": "Underground DC Disconnect LV",
"code": 448
},
{
"name": "Indoor AC Load Break LV",
"code": 449
},
{
"name": "Indoor AC Disconnect LV",
"code": 450
},
{
"name": "Indoor DC Load Break LV",
"code": 451
},
{
"name": "Indoor DC Disconnect LV",
"code": 452
},
{
"name": "Source Selectable Switch LV",
"code": 453
},
{
"name": "Overhead Jumper LV",
"code": 454
},
{
"name": "DC Station LV",
"code": 456
},
{
"name": "AC Station Bypass LV",
"code": 457
},
{
"name": "AC Recloser LV",
"code": 458
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps",
"description": "Low Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "45 A",
"code": 45
},
{
"name": "50 A",
"code": 50
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "300 A",
"code": 300
},
{
"name": "320 A",
"code": 320
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "2500 A",
"code": 2500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 23,
"name": "Low Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer",
"description": "Low Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Single Phase - LV->LV",
"code": 461
},
{
"name": "Three Phase - LV->LV",
"code": 462
},
{
"name": "Three Winding - LV->LV-LV",
"code": 463
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 24,
"name": "Low Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector",
"description": "Low Voltage Connectors",
"codedValues": [
{
"name": "Wire Connector",
"code": 0
},
{
"name": "Ring Terminal LV",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 44,
"name": "Low Voltage Wire Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator",
"description": "Asset Types for Low Voltage Regulating Equipment",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase LV",
"code": 141
},
{
"name": "AC Three Phase LV",
"code": 142
},
{
"name": "DC Regulator LV",
"code": 143
},
{
"name": "Network Load Balancer LV",
"code": 144
},
{
"name": "Frequency Converter LV",
"code": 145
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 45,
"name": "Low Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding LV",
"code": 874
},
{
"name": "DC Transformer Winding LV",
"code": 875
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 46,
"name": "Low Voltage Transformer Winding"
}
],
"subtypes": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tertiarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": null,
"maintby": null,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Ground",
"code": 0
},
{
"name": "Bound",
"code": 31
},
{
"name": "Rod",
"code": 32
},
{
"name": "Voltage Grid",
"code": 33
},
{
"name": "Stray Voltage Isolator",
"code": 34
},
{
"name": "Grounding Switch",
"code": 35
},
{
"name": "Cross Bond",
"code": 36
},
{
"name": "Ground Plate",
"code": 37
},
{
"name": "Ground Joint",
"code": 38
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Type",
"description": "Ground Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bound",
"code": 1
},
{
"name": "Mesh",
"code": 2
},
{
"name": "Rod",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 1,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit",
"description": "High Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor HV",
"code": 41
},
{
"name": "Switch and Breaker HV",
"code": 42
},
{
"name": "Voltage Regulator HV",
"code": 43
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 3,
"name": "High Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation",
"description": "High Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery HV",
"code": 61
},
{
"name": "Biomass HV",
"code": 62
},
{
"name": "Coal HV",
"code": 63
},
{
"name": "Gas Turbine HV",
"code": 64
},
{
"name": "Geothermal HV",
"code": 65
},
{
"name": "Hydro HV",
"code": 66
},
{
"name": "Nuclear HV",
"code": 67
},
{
"name": "Photovoltaic Solar HV",
"code": 68
},
{
"name": "Thermal Solar HV",
"code": 69
},
{
"name": "Wind HV",
"code": 70
},
{
"name": "AC Wave HV",
"code": 71
},
{
"name": "Generator HV",
"code": 72
},
{
"name": "Interconnect HV",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 4,
"name": "High Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse",
"description": "High Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Station Disconnect Fuse HV",
"code": 581
},
{
"name": "AC Station Load Break Fuse HV",
"code": 582
},
{
"name": "AC Load Break Disconnect Fuse HV",
"code": 583
},
{
"name": "AC Load Break Fuse HV - Controller",
"code": 584
},
{
"name": "AC Disconnect Fuse HV - Controller",
"code": 585
},
{
"name": "AC Load Break Disconnect Fuse HV - Controller",
"code": 586
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Continuous Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "3000 A",
"code": 3000
},
{
"name": "6000 A",
"code": 6000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "60 kA",
"code": 60000
},
{
"name": "80 kA",
"code": 80000
},
{
"name": "90 kA",
"code": 90000
},
{
"name": "2 kA",
"code": 2000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 43,
"name": "High Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay",
"description": "High Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator HV",
"code": 80
},
{
"name": "Instrument Transformer HV",
"code": 81
},
{
"name": "Load Monitor HV",
"code": 82
},
{
"name": "Relay HV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Phase_Angle_Offset_Range",
"description": "Phase Offset values 0 - 60",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 5,
"name": "High Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion",
"description": "High Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Inverter HV",
"code": 101
},
{
"name": "Rectifier HV",
"code": 102
},
{
"name": "Bidirectional HV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_DC_Voltage",
"description": "Valid High Voltage Direct Current Voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "270 kV",
"code": 270000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1000 kV",
"code": 1000000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
},
{
"name": "1400 kV",
"code": 1400000
},
{
"name": "1500 kV",
"code": 1500000
},
{
"name": "1800 kV",
"code": 1800000
},
{
"name": "2500 kV",
"code": 2500000
},
{
"name": "3000 kV",
"code": 3000000
},
{
"name": "4000 kV",
"code": 4000000
},
{
"name": "5000 kV",
"code": 5000000
},
{
"name": "6000 kV",
"code": 6000000
},
{
"name": "6400 kV",
"code": 6400000
},
{
"name": "7200 kV",
"code": 7200000
},
{
"name": "8000 kV",
"code": 8000000
},
{
"name": "10000 kV",
"code": 10000000
},
{
"name": "12000 kV",
"code": 12000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 6,
"name": "High Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting",
"description": "High Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Capacitor HV",
"code": 121
},
{
"name": "AC Wave Trap HV",
"code": 122
},
{
"name": "AC Reactor HV",
"code": 123
},
{
"name": "DC Capacitor HV",
"code": 124
},
{
"name": "DC Reactor HV",
"code": 125
},
{
"name": "Synchronous Condenser HV",
"code": 126
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Power_Factor_Correcting_Type",
"description": "Type of Power Factor Correcting Equipment",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 7,
"name": "High Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator",
"description": "High Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase HV",
"code": 171
},
{
"name": "AC Three Phase HV",
"code": 172
},
{
"name": "DC Regulator HV",
"code": 173
},
{
"name": "Frequency Converter HV",
"code": 174
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 8,
"name": "High Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service",
"description": "High Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "AC Metering HV",
"code": 161
},
{
"name": "DC Metering HV",
"code": 162
},
{
"name": "High Voltage Premise HV",
"code": 163
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 9,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch",
"description": "High Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Circuit Breaker HV",
"code": 181
},
{
"name": "AC Disconnect HV",
"code": 182
},
{
"name": "AC Switchgear HV",
"code": 183
},
{
"name": "DC Circuit Breaker HV",
"code": 184
},
{
"name": "DC Disconnect HV",
"code": 185
},
{
"name": "DC Switchgear HV",
"code": 186
},
{
"name": "AC Bus Tie Breaker HV",
"code": 187
},
{
"name": "DC Bus Tie Breaker HV",
"code": 188
},
{
"name": "AC Disconnect - Grounded HV",
"code": 189
},
{
"name": "AC Breaker Bypass HV",
"code": 190
},
{
"name": "AC Circuit Breaker HV - Controller",
"code": 191
},
{
"name": "AC Station Disconnect HV",
"code": 192
},
{
"name": "AC Station Load Break Disconnect HV - Controller",
"code": 193
},
{
"name": "DC Circuit Breaker HV - Controller",
"code": 194
},
{
"name": "AC Disconnect HV - Controller",
"code": 195
},
{
"name": "AC Grounding HV",
"code": 196
},
{
"name": "AC Thyristor HV",
"code": 197
},
{
"name": "DC Thyristor HV",
"code": 198
},
{
"name": "AC Transfer Switch HV",
"code": 199
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps",
"description": "High Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".6 kA",
"code": 600
},
{
"name": "1.2 kA",
"code": 1200
},
{
"name": "1.25 kA",
"code": 1250
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 10,
"name": "High Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer",
"description": "High Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "AC Single Phase - HV->MV",
"code": 201
},
{
"name": "AC Three Phase - HV->MV",
"code": 202
},
{
"name": "DC Power - HV->HV",
"code": 203
},
{
"name": "Grounding Transformer - HV->MV",
"code": 204
},
{
"name": "Station - HV->MV",
"code": 205
},
{
"name": "Station Three Winding - HV->HV-HV",
"code": 206
},
{
"name": "Station Three Winding - HV->HV-MV",
"code": 207
},
{
"name": "Phase Control - HV->HV",
"code": 208
},
{
"name": "Station Three Winding - HV->HV-LV",
"code": 209
},
{
"name": "Station Step Up - MV->HV",
"code": 210
},
{
"name": "Station Step - HV->HV",
"code": 211
},
{
"name": "Station Three Winding - HV->MV-MV",
"code": 212
},
{
"name": "Station Three Winding - HV->MV-LV",
"code": 213
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 11,
"name": "High Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Line Hardware",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 61,
"name": "High Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding HV",
"code": 871
},
{
"name": "DC Transformer Winding HV",
"code": 872
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 48,
"name": "High Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker",
"description": "Medium Voltage Circuit Breaker",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "Isolator Switch MV",
"code": 501
},
{
"name": "Single Phase Circuit Breaker MV",
"code": 502
},
{
"name": "Three Phase Circuit Breaker MV",
"code": 503
},
{
"name": "Single Phase Circuit Breaker MV - Controller",
"code": 512
},
{
"name": "Three Phase Circuit Breaker MV - Controller",
"code": 513
},
{
"name": "Network Protector MV",
"code": 515
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Medium Voltage Circuit Breaker Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "1250 A",
"code": 1250
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "2500 A",
"code": 2500
},
{
"name": "3000 A",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 26,
"name": "Medium Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit",
"description": "Medium Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor MV",
"code": 521
},
{
"name": "Circuit Breaker MV",
"code": 522
},
{
"name": "Recloser MV",
"code": 523
},
{
"name": "Transfer Switch Controller MV",
"code": 524
},
{
"name": "Regulator MV",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 27,
"name": "Medium Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow",
"description": "Medium Voltage Elbow",
"codedValues": [
{
"name": "Elbow",
"code": 0
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Load Break Feedthru MV",
"code": 541
},
{
"name": "Load Break Junction MV",
"code": 542
},
{
"name": "Single Phase Dead Break MV",
"code": 543
},
{
"name": "Single Phase Load Break MV",
"code": 544
},
{
"name": "Three Phase Dead Break MV",
"code": 545
},
{
"name": "Three Phase Load Break MV",
"code": 546
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 28,
"name": "Medium Voltage Elbow"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse",
"description": "Medium Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Bayonet Fuse MV",
"code": 561
},
{
"name": "Fault Limiter Fuse MV",
"code": 562
},
{
"name": "Indoor Fuse MV",
"code": 563
},
{
"name": "Overhead Cutout Disconnect Fuse MV",
"code": 564
},
{
"name": "Overhead Cutout Load Break Fuse MV",
"code": 565
},
{
"name": "Overhead Cutout Sectionalizer Fuse MV",
"code": 566
},
{
"name": "Overhead Cutout Solid Blade Fuse MV",
"code": 567
},
{
"name": "Cabinet Fuse MV",
"code": 568
},
{
"name": "Underground Fuse MV",
"code": 569
},
{
"name": "Underground Disconnect Fuse MV",
"code": 570
},
{
"name": "Underground Load Break Fuse MV",
"code": 571
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV",
"code": 572
},
{
"name": "Overhead Cutout Load Break Fuse MV - Controller",
"code": 573
},
{
"name": "Overhead Cutout Disconnect Fuse MV - Controller",
"code": 574
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller",
"code": 575
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Rating",
"description": "List of valid Electric Medium Voltage Fuse Ratingsl",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "E",
"code": 2
},
{
"name": "R",
"code": 3
},
{
"name": "PT",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Type",
"description": "Medium Voltage fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridged",
"code": 1
},
{
"name": "Burndy",
"code": 2
},
{
"name": "Bussman",
"code": 3
},
{
"name": "Cooper Elf",
"code": 4
},
{
"name": "D & W",
"code": 5
},
{
"name": "EJO-1",
"code": 6
},
{
"name": "Fault Tamer",
"code": 7
},
{
"name": "Kearney",
"code": 8
},
{
"name": "Kearney 200",
"code": 9
},
{
"name": "Kearney QA",
"code": 10
},
{
"name": "RTE B",
"code": 11
},
{
"name": "S & C",
"code": 12
},
{
"name": "S & C SM-4",
"code": 13
},
{
"name": "X-Limiter",
"code": 14
},
{
"name": "NX",
"code": 15
},
{
"name": "CL",
"code": 16
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 29,
"name": "Medium Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation",
"description": "Medium Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "AC Wave MV",
"code": 110
},
{
"name": "Battery MV",
"code": 111
},
{
"name": "Biomass MV",
"code": 112
},
{
"name": "Generator MV",
"code": 113
},
{
"name": "Gas Turbine MV",
"code": 114
},
{
"name": "Geothermal MV",
"code": 115
},
{
"name": "Hydro MV",
"code": 116
},
{
"name": "Wind MV",
"code": 117
},
{
"name": "Photovoltaic Solar MV",
"code": 118
},
{
"name": "Thermal Solar MV",
"code": 119
},
{
"name": "Interconnect MV",
"code": 120
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 30,
"name": "Medium Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay",
"description": "Medium Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator MV",
"code": 601
},
{
"name": "Instrument Transformer MV",
"code": 602
},
{
"name": "Programmable Logic Unit MV",
"code": 603
},
{
"name": "Remote Terminal Unit MV",
"code": 604
},
{
"name": "SCADA Load Monitor MV",
"code": 605
},
{
"name": "SCADA Weather Station MV",
"code": 606
},
{
"name": "Relay MV",
"code": 607
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 31,
"name": "Medium Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump",
"description": "Medium Voltage Motor and Pump",
"codedValues": [
{
"name": "Motor and Pump",
"code": 0
},
{
"name": "Single Phase Motor MV",
"code": 621
},
{
"name": "Single Phase Pump MV",
"code": 622
},
{
"name": "Three Phase Motor MV",
"code": 623
},
{
"name": "Three Phase Pump MV",
"code": 624
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 32,
"name": "Medium Voltage Motor and Pump"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion",
"description": "Medium Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter MV",
"code": 641
},
{
"name": "Single Phase Rectifier MV",
"code": 642
},
{
"name": "Three Phase Inverter MV",
"code": 643
},
{
"name": "Three Phase Rectifier MV",
"code": 644
},
{
"name": "Single Phase Bidirectional MV",
"code": 645
},
{
"name": "Three Phase Bidirectional MV",
"code": 646
},
{
"name": "Wave Trap MV",
"code": 647
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 33,
"name": "Medium Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting",
"description": "Medium Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Mobile Capacitor MV",
"code": 661
},
{
"name": "Overhead Single Phase Capacitor MV",
"code": 664
},
{
"name": "Overhead Three Phase Capacitor MV",
"code": 665
},
{
"name": "Overhead Harmonic Filter MV",
"code": 666
},
{
"name": "Overhead Reactor MV",
"code": 667
},
{
"name": "Pad Mounted Single Phase Capacitor MV",
"code": 668
},
{
"name": "Pad Mounted Three Phase Capacitor MV",
"code": 669
},
{
"name": "Mobile Harmonic Filter MV",
"code": 671
},
{
"name": "Mobile Reactor MV",
"code": 672
},
{
"name": "Pad Mounted Harmonic Filter MV",
"code": 673
},
{
"name": "Pad Mounted Reactor MV",
"code": 674
},
{
"name": "Station Capacitor MV",
"code": 675
},
{
"name": "Station Harmonic Filter MV",
"code": 676
},
{
"name": "Station Reactor MV",
"code": 677
},
{
"name": "Synchronous Condenser MV",
"code": 678
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 34,
"name": "Medium Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator",
"description": "Medium Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Overhead Single Phase VR MV",
"code": 681
},
{
"name": "Overhead Three Phase VR MV",
"code": 683
},
{
"name": "Pad Mounted Single Phase VR MV",
"code": 685
},
{
"name": "Pad Mounted Three Phase VR MV",
"code": 687
},
{
"name": "Frequency Converter MV",
"code": 688
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 35,
"name": "Medium Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service",
"description": "Medium Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Primary Meter - Industrial Customer MV",
"code": 701
},
{
"name": "Primary Meter - Utility Customer MV",
"code": 702
},
{
"name": "Primary Meter Circuit Source MV",
"code": 703
},
{
"name": "Medium Voltage Premise MV",
"code": 704
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 36,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser",
"description": "Medium Voltage Recloser Asset Types",
"codedValues": [
{
"name": "Recloser",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Recloser MV",
"code": 730
},
{
"name": "Overhead Three Phase Recloser MV - Controller",
"code": 734
},
{
"name": "Pad Mounted Three Phase Recloser MV - Controller",
"code": 738
},
{
"name": "Overhead Three Phase Recloser MV",
"code": 744
},
{
"name": "Pad Mounted Single Phase Recloser MV",
"code": 747
},
{
"name": "Pad Mounted Three Phase Recloser MV",
"code": 748
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps",
"description": "Medium Voltage Recloser Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "280 A",
"code": 280
},
{
"name": "400 A",
"code": 400
},
{
"name": "560 A",
"code": 560
},
{
"name": "600 A",
"code": 600
},
{
"name": "630 A",
"code": 630
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 41,
"name": "Medium Voltage Recloser"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer",
"description": "Medium Voltage Secitionalizer",
"codedValues": [
{
"name": "Sectionalizer",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Sectionalizer MV",
"code": 731
},
{
"name": "Overhead Three Phase Sectionalizer MV",
"code": 745
},
{
"name": "Pad Mounted Single Phase Sectionalizer MV",
"code": 749
},
{
"name": "Pad Mounted Three Phase Sectionalizer MV",
"code": 750
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 42,
"name": "Medium Voltage Sectionalizer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch",
"description": "Medium Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Cabinet Bypass MV",
"code": 721
},
{
"name": "Cabinet Switch MV",
"code": 722
},
{
"name": "Cabinet Switch - Grounded MV",
"code": 723
},
{
"name": "Overhead Bypass MV",
"code": 724
},
{
"name": "Overhead Grounding Switch MV",
"code": 725
},
{
"name": "Overhead Jumper MV",
"code": 726
},
{
"name": "Station Grounding MV",
"code": 727
},
{
"name": "Overhead Single Phase Disconnect MV",
"code": 728
},
{
"name": "Overhead Single Phase Load Break MV",
"code": 729
},
{
"name": "Overhead Three Phase Disconnect MV",
"code": 732
},
{
"name": "Overhead Three Phase Load Break MV",
"code": 733
},
{
"name": "Pad Mounted Fault Interrupter MV",
"code": 746
},
{
"name": "Station Single Phase Disconnect MV",
"code": 751
},
{
"name": "Station Disconnect MV",
"code": 752
},
{
"name": "T Blade MV",
"code": 753
},
{
"name": "V Blade MV",
"code": 754
},
{
"name": "Underground Single Phase Disconnect MV",
"code": 755
},
{
"name": "Underground Single Phase Load Break MV",
"code": 758
},
{
"name": "Underground Three Phase Disconnect MV",
"code": 759
},
{
"name": "Underground Three Phase Load Break MV",
"code": 760
},
{
"name": "Underground Transfer Switch MV",
"code": 761
},
{
"name": "Bus Tie Breaker MV",
"code": 765
},
{
"name": "Station Load Break MV",
"code": 766
},
{
"name": "Station Disconnect - Grounded MV",
"code": 768
},
{
"name": "Station Load Break Disconnect MV",
"code": 769
},
{
"name": "Station Disconnect MV - Controller",
"code": 770
},
{
"name": "Station Load Break MV - Controller",
"code": 771
},
{
"name": "Station Load Break Disconnect MV - Controller",
"code": 772
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps",
"description": "Medium Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "900 A",
"code": 900
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12000,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 37,
"name": "Medium Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer",
"description": "Medium Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Grounding Transformer - MV->MV",
"code": 781
},
{
"name": "Mobile Single Phase - MV->LV",
"code": 782
},
{
"name": "Mobile Three Phase - MV->LV",
"code": 783
},
{
"name": "Network - MV->LV",
"code": 784
},
{
"name": "Overhead Single Phase - MV->LV",
"code": 785
},
{
"name": "Station - MV->LV",
"code": 786
},
{
"name": "Station Three Winding - MV->LV-LV",
"code": 787
},
{
"name": "Overhead Three Phase - MV->LV",
"code": 788
},
{
"name": "Pad Mounted Single Phase - MV->LV",
"code": 789
},
{
"name": "Station Three Winding - MV->MV-LV",
"code": 790
},
{
"name": "Pad Mounted Three Phase - MV->LV",
"code": 792
},
{
"name": "Submersible Single Phase - MV->LV",
"code": 793
},
{
"name": "Submersible Three Phase - MV->LV",
"code": 794
},
{
"name": "Overhead Open Delta - MV->LV",
"code": 795
},
{
"name": "Overhead Open Wye - MV->LV",
"code": 796
},
{
"name": "Pad Mounted Open Delta - MV->LV",
"code": 797
},
{
"name": "Pad Mounted Open Wye - MV->LV",
"code": 798
},
{
"name": "Overhead Single Phase Step - MV<->MV",
"code": 801
},
{
"name": "Overhead Three Phase Step - MV<->MV",
"code": 802
},
{
"name": "Overhead Single Phase Step - MV->MV",
"code": 803
},
{
"name": "Overhead Three Phase Step - MV->MV",
"code": 804
},
{
"name": "Pad Mounted Single Phase Step - MV<->MV",
"code": 805
},
{
"name": "Pad Mounted Three Phase Step - MV<->MV",
"code": 806
},
{
"name": "Pad Mounted Single Phase Step - MV->MV",
"code": 807
},
{
"name": "Pad Mounted Three Phase Step - MV->MV",
"code": 808
},
{
"name": "Submersible Single Phase Step - MV<->MV",
"code": 809
},
{
"name": "Overhead Three Phase Wye Delta Closed Ground",
"code": 810
},
{
"name": "Submersible Single Phase Step - MV->MV",
"code": 811
},
{
"name": "Pad Mounted Three Phase Wye Delta Closed Ground",
"code": 812
},
{
"name": "Station Step - MV->MV",
"code": 813
},
{
"name": "Station Step - MV<->MV",
"code": 814
},
{
"name": "Station Step Three Winding - MV->MV-MV",
"code": 815
},
{
"name": "Overhead Three Phase Step Up - LV->MV",
"code": 816
},
{
"name": "Overhead Three Phase Step Up - LV<->MV",
"code": 817
},
{
"name": "Station Step Up - LV->MV",
"code": 818
},
{
"name": "Station Step Up - LV<->MV",
"code": 819
},
{
"name": "Pad Mounted Three Phase Step Up - LV->MV",
"code": 820
},
{
"name": "Pad Mounted Three Phase Step Up - LV<->MV",
"code": 821
},
{
"name": "Overhead Single Phase Step Up - LV->MV",
"code": 822
},
{
"name": "Overhead Single Phase Step Up - LV<->MV",
"code": 823
},
{
"name": "Pad Mounted Single Phase Step Up - LV->MV",
"code": 824
},
{
"name": "Pad Mounted Single Phase Step Up - LV<->MV",
"code": 825
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": "_CENTERTAPLOADMIX",
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 38,
"name": "Medium Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 62,
"name": "Medium Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "Transformer Winding MV",
"code": 873
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 47,
"name": "Medium Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker",
"description": "Asset Types for Low Voltage Circuit Breakers",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Circuit Breaker LV",
"code": 471
},
{
"name": "DC Circuit Breaker LV",
"code": 472
},
{
"name": "AC Circuit Breaker LV - Controller",
"code": 473
},
{
"name": "DC Circuit Breaker LV - Controller",
"code": 474
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Low Voltage Circuit Breaker Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 40,
"name": "Low Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit",
"description": "Low Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Control Unit LV",
"code": 241
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 13,
"name": "Low Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse",
"description": "Low Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "Service Fuse Load Break LV",
"code": 259
},
{
"name": "Service Fuse Disconnect LV",
"code": 260
},
{
"name": "AC Overhead Fuse LV",
"code": 261
},
{
"name": "AC Underground Fuse LV",
"code": 262
},
{
"name": "DC Overhead Fuse LV",
"code": 263
},
{
"name": "DC Underground Fuse LV",
"code": 264
},
{
"name": "AC Overhead Load Break Fuse LV",
"code": 265
},
{
"name": "AC Overhead Fuse LV - Controller",
"code": 266
},
{
"name": "AC Underground Load Break Fuse LV",
"code": 267
},
{
"name": "AC Underground Fuse LV - Controller",
"code": 268
},
{
"name": "DC Overhead Fuse LV - Controller",
"code": 269
},
{
"name": "DC Underground Fuse LV - Controller",
"code": 270
},
{
"name": "AC Overhead Cutout Load Break Disconnect Fuse LV",
"code": 271
},
{
"name": "AC Overhead Cutout Load Break Fuse LV - Controller",
"code": 272
},
{
"name": "AC Overhead Cutout Disconnect Fuse LV - Controller",
"code": 273
},
{
"name": "AC Overhead Cutout Load Break Fuse LV",
"code": 274
},
{
"name": "Station Disconnect Fuse LV",
"code": 275
},
{
"name": "Station Load Break Fuse LV",
"code": 276
},
{
"name": "Station Load Break Disconnect Fuse LV",
"code": 277
},
{
"name": "Station Disconnect Fuse LV - Controller",
"code": 278
},
{
"name": "Station Load Break Fuse LV - Controller",
"code": 279
},
{
"name": "Station Load Break Disconnect Fuse LV - Controller",
"code": 280
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Type",
"description": "List of valid fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Link_Type",
"description": "Types of fuse links",
"codedValues": [
{
"name": "K",
"code": 10
},
{
"name": "T",
"code": 11
},
{
"name": "MS",
"code": 12
},
{
"name": "QH",
"code": 13
},
{
"name": "Standard",
"code": 14
},
{
"name": "SloFast",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 14,
"name": "Low Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation",
"description": "Low Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery LV",
"code": 281
},
{
"name": "Generator LV",
"code": 283
},
{
"name": "Residential Photovoltaic Solar LV",
"code": 284
},
{
"name": "Wind Turbine LV",
"code": 285
},
{
"name": "AC Wave LV",
"code": 286
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 15,
"name": "Low Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting",
"description": "Low Voltage Lighting",
"codedValues": [
{
"name": "Lighting",
"code": 0
},
{
"name": "Floodlight LV",
"code": 301
},
{
"name": "Streetlight LV",
"code": 302
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Light_Housing_Type",
"description": "Light Housing Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cobra Head",
"code": 1
},
{
"name": "Security",
"code": 2
},
{
"name": "Roadway",
"code": 3
},
{
"name": "Flood",
"code": 4
},
{
"name": "Decorative",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Street_Bulb_Type",
"description": "List of valid bulb types for streetlights",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "High Pressure Sodium (HPS)",
"code": 30
},
{
"name": "Low Pressure Sodium (LPS)",
"code": 31
},
{
"name": "Metal Halide (MH)",
"code": 32
},
{
"name": "Mercury Vapor (MV)",
"code": 33
},
{
"name": "Halogen (HG)",
"code": 34
},
{
"name": "Light Emitting Diode (LED)",
"code": 35
},
{
"name": "Phosphor-Converted Amber LED (PCA)",
"code": 36
},
{
"name": "Narrow-Band Amber LED (NBA)",
"code": 37
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"lightsphotoeye": {"type": "inherited"},
"lightswattage": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 16,
"name": "Low Voltage Lighting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay",
"description": "Low Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator LV",
"code": 321
},
{
"name": "Load Monitor LV",
"code": 322
},
{
"name": "Relay LV",
"code": 323
},
{
"name": "Instrument Transformer LV",
"code": 324
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 17,
"name": "Low Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor",
"description": "Low Voltage Motor",
"codedValues": [
{
"name": "Motor",
"code": 0
},
{
"name": "Single Phase Motor LV",
"code": 341
},
{
"name": "Three Phase Motor LV",
"code": 342
},
{
"name": "DC Motor LV",
"code": 343
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 18,
"name": "Low Voltage Motor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection",
"description": "Low Voltage Network Protection",
"codedValues": [
{
"name": "Network Protector",
"code": 0
},
{
"name": "Network Protector LV",
"code": 361
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 19,
"name": "Low Voltage Network Protection"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion",
"description": "Low Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter LV",
"code": 381
},
{
"name": "Single Phase Rectifier LV",
"code": 382
},
{
"name": "Three Phase Inverter LV",
"code": 383
},
{
"name": "Three Phase Rectifier LV",
"code": 384
},
{
"name": "Single Phase Bidirectional LV",
"code": 386
},
{
"name": "Three Phase Bidirectional LV",
"code": 387
},
{
"name": "Wave Trap LV",
"code": 390
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 20,
"name": "Low Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting",
"description": "Low Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "Mobile Harmonic Filter LV",
"code": 401
},
{
"name": "Mobile Reactor LV",
"code": 402
},
{
"name": "Overhead Capacitor LV",
"code": 403
},
{
"name": "Overhead Harmonic Filter LV",
"code": 404
},
{
"name": "Overhead Reactor LV",
"code": 405
},
{
"name": "Pad Mounted Capacitor LV",
"code": 406
},
{
"name": "Pad Mounted Harmonic Filter LV",
"code": 407
},
{
"name": "Pad Mounted Reactor LV",
"code": 408
},
{
"name": "Station Capacitor LV",
"code": 409
},
{
"name": "Station Harmonic Filter LV",
"code": 410
},
{
"name": "Station Reactor LV",
"code": 411
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 21,
"name": "Low Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service",
"description": "Low Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Single Phase Commercial LV",
"code": 421
},
{
"name": "Single Phase Residential LV",
"code": 422
},
{
"name": "Three Phase Commercial LV",
"code": 423
},
{
"name": "Three Phase Residential LV",
"code": 424
},
{
"name": "Unmetered Load LV",
"code": 425
},
{
"name": "DC Commercial LV",
"code": 426
},
{
"name": "Low Voltage Premise LV",
"code": 427
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": "_CENTERTAPLOADMIX",
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 22,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch",
"description": "Low Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Station Disconnect LV",
"code": 431
},
{
"name": "AC Station Load Break LV",
"code": 432
},
{
"name": "AC Station Load Break Disconnect LV",
"code": 433
},
{
"name": "AC Station Disconnect LV - Controller",
"code": 434
},
{
"name": "AC Station Load Break LV - Controller",
"code": 435
},
{
"name": "AC Station Load Break Disconnect LV - Controller",
"code": 436
},
{
"name": "Overhead AC Load Break LV",
"code": 441
},
{
"name": "Overhead AC Disconnect LV",
"code": 442
},
{
"name": "Overhead DC Load Break LV",
"code": 443
},
{
"name": "Overhead DC Disconnect LV",
"code": 444
},
{
"name": "Underground AC Load Break LV",
"code": 445
},
{
"name": "Underground AC Disconnect LV",
"code": 446
},
{
"name": "Underground DC Load Break LV",
"code": 447
},
{
"name": "Underground DC Disconnect LV",
"code": 448
},
{
"name": "Indoor AC Load Break LV",
"code": 449
},
{
"name": "Indoor AC Disconnect LV",
"code": 450
},
{
"name": "Indoor DC Load Break LV",
"code": 451
},
{
"name": "Indoor DC Disconnect LV",
"code": 452
},
{
"name": "Source Selectable Switch LV",
"code": 453
},
{
"name": "Overhead Jumper LV",
"code": 454
},
{
"name": "DC Station LV",
"code": 456
},
{
"name": "AC Station Bypass LV",
"code": 457
},
{
"name": "AC Recloser LV",
"code": 458
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps",
"description": "Low Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "45 A",
"code": 45
},
{
"name": "50 A",
"code": 50
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "300 A",
"code": 300
},
{
"name": "320 A",
"code": 320
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "2500 A",
"code": 2500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 23,
"name": "Low Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer",
"description": "Low Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Single Phase - LV->LV",
"code": 461
},
{
"name": "Three Phase - LV->LV",
"code": 462
},
{
"name": "Three Winding - LV->LV-LV",
"code": 463
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 24,
"name": "Low Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector",
"description": "Low Voltage Connectors",
"codedValues": [
{
"name": "Wire Connector",
"code": 0
},
{
"name": "Ring Terminal LV",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 44,
"name": "Low Voltage Wire Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator",
"description": "Asset Types for Low Voltage Regulating Equipment",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase LV",
"code": 141
},
{
"name": "AC Three Phase LV",
"code": 142
},
{
"name": "DC Regulator LV",
"code": 143
},
{
"name": "Network Load Balancer LV",
"code": 144
},
{
"name": "Frequency Converter LV",
"code": 145
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 45,
"name": "Low Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding LV",
"code": 874
},
{
"name": "DC Transformer Winding LV",
"code": 875
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 46,
"name": "Low Voltage Transformer Winding"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"hasM": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1757937024000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 420,
"name": "Streetlight",
"type": "Feature Layer",
"description": " These are features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>",
"geometryType": "esriGeometryPoint",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
},
"copyrightText": "",
"parentLayer": {
"id": 400,
"name": "Electric"
},
"subLayers": [],
"minScale": 2000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriPMS",
"url": "8709531302979b3aa502d12e7659f144",
"imageData": "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",
"contentType": "image/png",
"width": 15,
"height": 15,
"angle": 0,
"xoffset": 0,
"yoffset": 0
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 643690.5494070798,
"ymin": 639234.0107380748,
"xmax": 707061.4210246615,
"ymax": 688815.7550783232,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "assetgroup",
"typeIdField": "ASSETGROUP",
"subtypeFieldName": "ASSETGROUP",
"subtypeField": "ASSETGROUP",
"defaultSubtypeCode": 0,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "ASSETGROUP",
"type": "esriFieldTypeInteger",
"alias": "Asset Group",
"domain": null
},
{
"name": "ASSETTYPE",
"type": "esriFieldTypeSmallInteger",
"alias": "Asset Type",
"domain": null
},
{
"name": "lifecyclestatus",
"type": "esriFieldTypeSmallInteger",
"alias": "Lifecycle Status",
"domain": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status_Combined",
"description": "Bitwise combination of lifecycle states for subnetwork management",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Proposed and In Service",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "In Service and Planned Removal",
"code": 6
},
{
"name": "Maintenance",
"code": 7
},
{
"name": "Design",
"code": 11
},
{
"name": "Abandoned",
"code": 12
},
{
"name": "Removed",
"code": 13
},
{
"name": "Retired",
"code": 14
},
{
"name": "NA",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S182_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tertiarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Ground",
"code": 0
},
{
"name": "Bound",
"code": 31
},
{
"name": "Rod",
"code": 32
},
{
"name": "Voltage Grid",
"code": 33
},
{
"name": "Stray Voltage Isolator",
"code": 34
},
{
"name": "Grounding Switch",
"code": 35
},
{
"name": "Cross Bond",
"code": 36
},
{
"name": "Ground Plate",
"code": 37
},
{
"name": "Ground Joint",
"code": 38
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Type",
"description": "Ground Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bound",
"code": 1
},
{
"name": "Mesh",
"code": 2
},
{
"name": "Rod",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 1,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit",
"description": "High Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor HV",
"code": 41
},
{
"name": "Switch and Breaker HV",
"code": 42
},
{
"name": "Voltage Regulator HV",
"code": 43
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 3,
"name": "High Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation",
"description": "High Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery HV",
"code": 61
},
{
"name": "Biomass HV",
"code": 62
},
{
"name": "Coal HV",
"code": 63
},
{
"name": "Gas Turbine HV",
"code": 64
},
{
"name": "Geothermal HV",
"code": 65
},
{
"name": "Hydro HV",
"code": 66
},
{
"name": "Nuclear HV",
"code": 67
},
{
"name": "Photovoltaic Solar HV",
"code": 68
},
{
"name": "Thermal Solar HV",
"code": 69
},
{
"name": "Wind HV",
"code": 70
},
{
"name": "AC Wave HV",
"code": 71
},
{
"name": "Generator HV",
"code": 72
},
{
"name": "Interconnect HV",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 4,
"name": "High Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse",
"description": "High Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Station Disconnect Fuse HV",
"code": 581
},
{
"name": "AC Station Load Break Fuse HV",
"code": 582
},
{
"name": "AC Load Break Disconnect Fuse HV",
"code": 583
},
{
"name": "AC Load Break Fuse HV - Controller",
"code": 584
},
{
"name": "AC Disconnect Fuse HV - Controller",
"code": 585
},
{
"name": "AC Load Break Disconnect Fuse HV - Controller",
"code": 586
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Continuous Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "3000 A",
"code": 3000
},
{
"name": "6000 A",
"code": 6000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "60 kA",
"code": 60000
},
{
"name": "80 kA",
"code": 80000
},
{
"name": "90 kA",
"code": 90000
},
{
"name": "2 kA",
"code": 2000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 43,
"name": "High Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay",
"description": "High Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator HV",
"code": 80
},
{
"name": "Instrument Transformer HV",
"code": 81
},
{
"name": "Load Monitor HV",
"code": 82
},
{
"name": "Relay HV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Phase_Angle_Offset_Range",
"description": "Phase Offset values 0 - 60",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 5,
"name": "High Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion",
"description": "High Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Inverter HV",
"code": 101
},
{
"name": "Rectifier HV",
"code": 102
},
{
"name": "Bidirectional HV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_DC_Voltage",
"description": "Valid High Voltage Direct Current Voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "270 kV",
"code": 270000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1000 kV",
"code": 1000000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
},
{
"name": "1400 kV",
"code": 1400000
},
{
"name": "1500 kV",
"code": 1500000
},
{
"name": "1800 kV",
"code": 1800000
},
{
"name": "2500 kV",
"code": 2500000
},
{
"name": "3000 kV",
"code": 3000000
},
{
"name": "4000 kV",
"code": 4000000
},
{
"name": "5000 kV",
"code": 5000000
},
{
"name": "6000 kV",
"code": 6000000
},
{
"name": "6400 kV",
"code": 6400000
},
{
"name": "7200 kV",
"code": 7200000
},
{
"name": "8000 kV",
"code": 8000000
},
{
"name": "10000 kV",
"code": 10000000
},
{
"name": "12000 kV",
"code": 12000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 6,
"name": "High Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting",
"description": "High Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Capacitor HV",
"code": 121
},
{
"name": "AC Wave Trap HV",
"code": 122
},
{
"name": "AC Reactor HV",
"code": 123
},
{
"name": "DC Capacitor HV",
"code": 124
},
{
"name": "DC Reactor HV",
"code": 125
},
{
"name": "Synchronous Condenser HV",
"code": 126
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Power_Factor_Correcting_Type",
"description": "Type of Power Factor Correcting Equipment",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 7,
"name": "High Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator",
"description": "High Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase HV",
"code": 171
},
{
"name": "AC Three Phase HV",
"code": 172
},
{
"name": "DC Regulator HV",
"code": 173
},
{
"name": "Frequency Converter HV",
"code": 174
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 8,
"name": "High Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service",
"description": "High Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "AC Metering HV",
"code": 161
},
{
"name": "DC Metering HV",
"code": 162
},
{
"name": "High Voltage Premise HV",
"code": 163
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 9,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch",
"description": "High Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Circuit Breaker HV",
"code": 181
},
{
"name": "AC Disconnect HV",
"code": 182
},
{
"name": "AC Switchgear HV",
"code": 183
},
{
"name": "DC Circuit Breaker HV",
"code": 184
},
{
"name": "DC Disconnect HV",
"code": 185
},
{
"name": "DC Switchgear HV",
"code": 186
},
{
"name": "AC Bus Tie Breaker HV",
"code": 187
},
{
"name": "DC Bus Tie Breaker HV",
"code": 188
},
{
"name": "AC Disconnect - Grounded HV",
"code": 189
},
{
"name": "AC Breaker Bypass HV",
"code": 190
},
{
"name": "AC Circuit Breaker HV - Controller",
"code": 191
},
{
"name": "AC Station Disconnect HV",
"code": 192
},
{
"name": "AC Station Load Break Disconnect HV - Controller",
"code": 193
},
{
"name": "DC Circuit Breaker HV - Controller",
"code": 194
},
{
"name": "AC Disconnect HV - Controller",
"code": 195
},
{
"name": "AC Grounding HV",
"code": 196
},
{
"name": "AC Thyristor HV",
"code": 197
},
{
"name": "DC Thyristor HV",
"code": 198
},
{
"name": "AC Transfer Switch HV",
"code": 199
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps",
"description": "High Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".6 kA",
"code": 600
},
{
"name": "1.2 kA",
"code": 1200
},
{
"name": "1.25 kA",
"code": 1250
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 10,
"name": "High Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer",
"description": "High Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "AC Single Phase - HV->MV",
"code": 201
},
{
"name": "AC Three Phase - HV->MV",
"code": 202
},
{
"name": "DC Power - HV->HV",
"code": 203
},
{
"name": "Grounding Transformer - HV->MV",
"code": 204
},
{
"name": "Station - HV->MV",
"code": 205
},
{
"name": "Station Three Winding - HV->HV-HV",
"code": 206
},
{
"name": "Station Three Winding - HV->HV-MV",
"code": 207
},
{
"name": "Phase Control - HV->HV",
"code": 208
},
{
"name": "Station Three Winding - HV->HV-LV",
"code": 209
},
{
"name": "Station Step Up - MV->HV",
"code": 210
},
{
"name": "Station Step - HV->HV",
"code": 211
},
{
"name": "Station Three Winding - HV->MV-MV",
"code": 212
},
{
"name": "Station Three Winding - HV->MV-LV",
"code": 213
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 11,
"name": "High Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Line Hardware",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 61,
"name": "High Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding HV",
"code": 871
},
{
"name": "DC Transformer Winding HV",
"code": 872
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 48,
"name": "High Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker",
"description": "Medium Voltage Circuit Breaker",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "Isolator Switch MV",
"code": 501
},
{
"name": "Single Phase Circuit Breaker MV",
"code": 502
},
{
"name": "Three Phase Circuit Breaker MV",
"code": 503
},
{
"name": "Single Phase Circuit Breaker MV - Controller",
"code": 512
},
{
"name": "Three Phase Circuit Breaker MV - Controller",
"code": 513
},
{
"name": "Network Protector MV",
"code": 515
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Medium Voltage Circuit Breaker Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "1250 A",
"code": 1250
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "2500 A",
"code": 2500
},
{
"name": "3000 A",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 26,
"name": "Medium Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit",
"description": "Medium Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor MV",
"code": 521
},
{
"name": "Circuit Breaker MV",
"code": 522
},
{
"name": "Recloser MV",
"code": 523
},
{
"name": "Transfer Switch Controller MV",
"code": 524
},
{
"name": "Regulator MV",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 27,
"name": "Medium Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow",
"description": "Medium Voltage Elbow",
"codedValues": [
{
"name": "Elbow",
"code": 0
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Load Break Feedthru MV",
"code": 541
},
{
"name": "Load Break Junction MV",
"code": 542
},
{
"name": "Single Phase Dead Break MV",
"code": 543
},
{
"name": "Single Phase Load Break MV",
"code": 544
},
{
"name": "Three Phase Dead Break MV",
"code": 545
},
{
"name": "Three Phase Load Break MV",
"code": 546
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 28,
"name": "Medium Voltage Elbow"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse",
"description": "Medium Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Bayonet Fuse MV",
"code": 561
},
{
"name": "Fault Limiter Fuse MV",
"code": 562
},
{
"name": "Indoor Fuse MV",
"code": 563
},
{
"name": "Overhead Cutout Disconnect Fuse MV",
"code": 564
},
{
"name": "Overhead Cutout Load Break Fuse MV",
"code": 565
},
{
"name": "Overhead Cutout Sectionalizer Fuse MV",
"code": 566
},
{
"name": "Overhead Cutout Solid Blade Fuse MV",
"code": 567
},
{
"name": "Cabinet Fuse MV",
"code": 568
},
{
"name": "Underground Fuse MV",
"code": 569
},
{
"name": "Underground Disconnect Fuse MV",
"code": 570
},
{
"name": "Underground Load Break Fuse MV",
"code": 571
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV",
"code": 572
},
{
"name": "Overhead Cutout Load Break Fuse MV - Controller",
"code": 573
},
{
"name": "Overhead Cutout Disconnect Fuse MV - Controller",
"code": 574
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller",
"code": 575
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Rating",
"description": "List of valid Electric Medium Voltage Fuse Ratingsl",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "E",
"code": 2
},
{
"name": "R",
"code": 3
},
{
"name": "PT",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Type",
"description": "Medium Voltage fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridged",
"code": 1
},
{
"name": "Burndy",
"code": 2
},
{
"name": "Bussman",
"code": 3
},
{
"name": "Cooper Elf",
"code": 4
},
{
"name": "D & W",
"code": 5
},
{
"name": "EJO-1",
"code": 6
},
{
"name": "Fault Tamer",
"code": 7
},
{
"name": "Kearney",
"code": 8
},
{
"name": "Kearney 200",
"code": 9
},
{
"name": "Kearney QA",
"code": 10
},
{
"name": "RTE B",
"code": 11
},
{
"name": "S & C",
"code": 12
},
{
"name": "S & C SM-4",
"code": 13
},
{
"name": "X-Limiter",
"code": 14
},
{
"name": "NX",
"code": 15
},
{
"name": "CL",
"code": 16
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 29,
"name": "Medium Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation",
"description": "Medium Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "AC Wave MV",
"code": 110
},
{
"name": "Battery MV",
"code": 111
},
{
"name": "Biomass MV",
"code": 112
},
{
"name": "Generator MV",
"code": 113
},
{
"name": "Gas Turbine MV",
"code": 114
},
{
"name": "Geothermal MV",
"code": 115
},
{
"name": "Hydro MV",
"code": 116
},
{
"name": "Wind MV",
"code": 117
},
{
"name": "Photovoltaic Solar MV",
"code": 118
},
{
"name": "Thermal Solar MV",
"code": 119
},
{
"name": "Interconnect MV",
"code": 120
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 30,
"name": "Medium Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay",
"description": "Medium Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator MV",
"code": 601
},
{
"name": "Instrument Transformer MV",
"code": 602
},
{
"name": "Programmable Logic Unit MV",
"code": 603
},
{
"name": "Remote Terminal Unit MV",
"code": 604
},
{
"name": "SCADA Load Monitor MV",
"code": 605
},
{
"name": "SCADA Weather Station MV",
"code": 606
},
{
"name": "Relay MV",
"code": 607
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 31,
"name": "Medium Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump",
"description": "Medium Voltage Motor and Pump",
"codedValues": [
{
"name": "Motor and Pump",
"code": 0
},
{
"name": "Single Phase Motor MV",
"code": 621
},
{
"name": "Single Phase Pump MV",
"code": 622
},
{
"name": "Three Phase Motor MV",
"code": 623
},
{
"name": "Three Phase Pump MV",
"code": 624
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 32,
"name": "Medium Voltage Motor and Pump"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion",
"description": "Medium Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter MV",
"code": 641
},
{
"name": "Single Phase Rectifier MV",
"code": 642
},
{
"name": "Three Phase Inverter MV",
"code": 643
},
{
"name": "Three Phase Rectifier MV",
"code": 644
},
{
"name": "Single Phase Bidirectional MV",
"code": 645
},
{
"name": "Three Phase Bidirectional MV",
"code": 646
},
{
"name": "Wave Trap MV",
"code": 647
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 33,
"name": "Medium Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting",
"description": "Medium Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Mobile Capacitor MV",
"code": 661
},
{
"name": "Overhead Single Phase Capacitor MV",
"code": 664
},
{
"name": "Overhead Three Phase Capacitor MV",
"code": 665
},
{
"name": "Overhead Harmonic Filter MV",
"code": 666
},
{
"name": "Overhead Reactor MV",
"code": 667
},
{
"name": "Pad Mounted Single Phase Capacitor MV",
"code": 668
},
{
"name": "Pad Mounted Three Phase Capacitor MV",
"code": 669
},
{
"name": "Mobile Harmonic Filter MV",
"code": 671
},
{
"name": "Mobile Reactor MV",
"code": 672
},
{
"name": "Pad Mounted Harmonic Filter MV",
"code": 673
},
{
"name": "Pad Mounted Reactor MV",
"code": 674
},
{
"name": "Station Capacitor MV",
"code": 675
},
{
"name": "Station Harmonic Filter MV",
"code": 676
},
{
"name": "Station Reactor MV",
"code": 677
},
{
"name": "Synchronous Condenser MV",
"code": 678
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 34,
"name": "Medium Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator",
"description": "Medium Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Overhead Single Phase VR MV",
"code": 681
},
{
"name": "Overhead Three Phase VR MV",
"code": 683
},
{
"name": "Pad Mounted Single Phase VR MV",
"code": 685
},
{
"name": "Pad Mounted Three Phase VR MV",
"code": 687
},
{
"name": "Frequency Converter MV",
"code": 688
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 35,
"name": "Medium Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service",
"description": "Medium Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Primary Meter - Industrial Customer MV",
"code": 701
},
{
"name": "Primary Meter - Utility Customer MV",
"code": 702
},
{
"name": "Primary Meter Circuit Source MV",
"code": 703
},
{
"name": "Medium Voltage Premise MV",
"code": 704
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 36,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser",
"description": "Medium Voltage Recloser Asset Types",
"codedValues": [
{
"name": "Recloser",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Recloser MV",
"code": 730
},
{
"name": "Overhead Three Phase Recloser MV - Controller",
"code": 734
},
{
"name": "Pad Mounted Three Phase Recloser MV - Controller",
"code": 738
},
{
"name": "Overhead Three Phase Recloser MV",
"code": 744
},
{
"name": "Pad Mounted Single Phase Recloser MV",
"code": 747
},
{
"name": "Pad Mounted Three Phase Recloser MV",
"code": 748
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps",
"description": "Medium Voltage Recloser Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "280 A",
"code": 280
},
{
"name": "400 A",
"code": 400
},
{
"name": "560 A",
"code": 560
},
{
"name": "600 A",
"code": 600
},
{
"name": "630 A",
"code": 630
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 41,
"name": "Medium Voltage Recloser"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer",
"description": "Medium Voltage Secitionalizer",
"codedValues": [
{
"name": "Sectionalizer",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Sectionalizer MV",
"code": 731
},
{
"name": "Overhead Three Phase Sectionalizer MV",
"code": 745
},
{
"name": "Pad Mounted Single Phase Sectionalizer MV",
"code": 749
},
{
"name": "Pad Mounted Three Phase Sectionalizer MV",
"code": 750
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 42,
"name": "Medium Voltage Sectionalizer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch",
"description": "Medium Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Cabinet Bypass MV",
"code": 721
},
{
"name": "Cabinet Switch MV",
"code": 722
},
{
"name": "Cabinet Switch - Grounded MV",
"code": 723
},
{
"name": "Overhead Bypass MV",
"code": 724
},
{
"name": "Overhead Grounding Switch MV",
"code": 725
},
{
"name": "Overhead Jumper MV",
"code": 726
},
{
"name": "Station Grounding MV",
"code": 727
},
{
"name": "Overhead Single Phase Disconnect MV",
"code": 728
},
{
"name": "Overhead Single Phase Load Break MV",
"code": 729
},
{
"name": "Overhead Three Phase Disconnect MV",
"code": 732
},
{
"name": "Overhead Three Phase Load Break MV",
"code": 733
},
{
"name": "Pad Mounted Fault Interrupter MV",
"code": 746
},
{
"name": "Station Single Phase Disconnect MV",
"code": 751
},
{
"name": "Station Disconnect MV",
"code": 752
},
{
"name": "T Blade MV",
"code": 753
},
{
"name": "V Blade MV",
"code": 754
},
{
"name": "Underground Single Phase Disconnect MV",
"code": 755
},
{
"name": "Underground Single Phase Load Break MV",
"code": 758
},
{
"name": "Underground Three Phase Disconnect MV",
"code": 759
},
{
"name": "Underground Three Phase Load Break MV",
"code": 760
},
{
"name": "Underground Transfer Switch MV",
"code": 761
},
{
"name": "Bus Tie Breaker MV",
"code": 765
},
{
"name": "Station Load Break MV",
"code": 766
},
{
"name": "Station Disconnect - Grounded MV",
"code": 768
},
{
"name": "Station Load Break Disconnect MV",
"code": 769
},
{
"name": "Station Disconnect MV - Controller",
"code": 770
},
{
"name": "Station Load Break MV - Controller",
"code": 771
},
{
"name": "Station Load Break Disconnect MV - Controller",
"code": 772
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps",
"description": "Medium Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "900 A",
"code": 900
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 37,
"name": "Medium Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer",
"description": "Medium Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Grounding Transformer - MV->MV",
"code": 781
},
{
"name": "Mobile Single Phase - MV->LV",
"code": 782
},
{
"name": "Mobile Three Phase - MV->LV",
"code": 783
},
{
"name": "Network - MV->LV",
"code": 784
},
{
"name": "Overhead Single Phase - MV->LV",
"code": 785
},
{
"name": "Station - MV->LV",
"code": 786
},
{
"name": "Station Three Winding - MV->LV-LV",
"code": 787
},
{
"name": "Overhead Three Phase - MV->LV",
"code": 788
},
{
"name": "Pad Mounted Single Phase - MV->LV",
"code": 789
},
{
"name": "Station Three Winding - MV->MV-LV",
"code": 790
},
{
"name": "Pad Mounted Three Phase - MV->LV",
"code": 792
},
{
"name": "Submersible Single Phase - MV->LV",
"code": 793
},
{
"name": "Submersible Three Phase - MV->LV",
"code": 794
},
{
"name": "Overhead Open Delta - MV->LV",
"code": 795
},
{
"name": "Overhead Open Wye - MV->LV",
"code": 796
},
{
"name": "Pad Mounted Open Delta - MV->LV",
"code": 797
},
{
"name": "Pad Mounted Open Wye - MV->LV",
"code": 798
},
{
"name": "Overhead Single Phase Step - MV<->MV",
"code": 801
},
{
"name": "Overhead Three Phase Step - MV<->MV",
"code": 802
},
{
"name": "Overhead Single Phase Step - MV->MV",
"code": 803
},
{
"name": "Overhead Three Phase Step - MV->MV",
"code": 804
},
{
"name": "Pad Mounted Single Phase Step - MV<->MV",
"code": 805
},
{
"name": "Pad Mounted Three Phase Step - MV<->MV",
"code": 806
},
{
"name": "Pad Mounted Single Phase Step - MV->MV",
"code": 807
},
{
"name": "Pad Mounted Three Phase Step - MV->MV",
"code": 808
},
{
"name": "Submersible Single Phase Step - MV<->MV",
"code": 809
},
{
"name": "Overhead Three Phase Wye Delta Closed Ground",
"code": 810
},
{
"name": "Submersible Single Phase Step - MV->MV",
"code": 811
},
{
"name": "Pad Mounted Three Phase Wye Delta Closed Ground",
"code": 812
},
{
"name": "Station Step - MV->MV",
"code": 813
},
{
"name": "Station Step - MV<->MV",
"code": 814
},
{
"name": "Station Step Three Winding - MV->MV-MV",
"code": 815
},
{
"name": "Overhead Three Phase Step Up - LV->MV",
"code": 816
},
{
"name": "Overhead Three Phase Step Up - LV<->MV",
"code": 817
},
{
"name": "Station Step Up - LV->MV",
"code": 818
},
{
"name": "Station Step Up - LV<->MV",
"code": 819
},
{
"name": "Pad Mounted Three Phase Step Up - LV->MV",
"code": 820
},
{
"name": "Pad Mounted Three Phase Step Up - LV<->MV",
"code": 821
},
{
"name": "Overhead Single Phase Step Up - LV->MV",
"code": 822
},
{
"name": "Overhead Single Phase Step Up - LV<->MV",
"code": 823
},
{
"name": "Pad Mounted Single Phase Step Up - LV->MV",
"code": 824
},
{
"name": "Pad Mounted Single Phase Step Up - LV<->MV",
"code": 825
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 38,
"name": "Medium Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 62,
"name": "Medium Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "Transformer Winding MV",
"code": 873
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 47,
"name": "Medium Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker",
"description": "Asset Types for Low Voltage Circuit Breakers",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Circuit Breaker LV",
"code": 471
},
{
"name": "DC Circuit Breaker LV",
"code": 472
},
{
"name": "AC Circuit Breaker LV - Controller",
"code": 473
},
{
"name": "DC Circuit Breaker LV - Controller",
"code": 474
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Low Voltage Circuit Breaker Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 40,
"name": "Low Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit",
"description": "Low Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Control Unit LV",
"code": 241
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 13,
"name": "Low Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse",
"description": "Low Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "Service Fuse Load Break LV",
"code": 259
},
{
"name": "Service Fuse Disconnect LV",
"code": 260
},
{
"name": "AC Overhead Fuse LV",
"code": 261
},
{
"name": "AC Underground Fuse LV",
"code": 262
},
{
"name": "DC Overhead Fuse LV",
"code": 263
},
{
"name": "DC Underground Fuse LV",
"code": 264
},
{
"name": "AC Overhead Load Break Fuse LV",
"code": 265
},
{
"name": "AC Overhead Fuse LV - Controller",
"code": 266
},
{
"name": "AC Underground Load Break Fuse LV",
"code": 267
},
{
"name": "AC Underground Fuse LV - Controller",
"code": 268
},
{
"name": "DC Overhead Fuse LV - Controller",
"code": 269
},
{
"name": "DC Underground Fuse LV - Controller",
"code": 270
},
{
"name": "AC Overhead Cutout Load Break Disconnect Fuse LV",
"code": 271
},
{
"name": "AC Overhead Cutout Load Break Fuse LV - Controller",
"code": 272
},
{
"name": "AC Overhead Cutout Disconnect Fuse LV - Controller",
"code": 273
},
{
"name": "AC Overhead Cutout Load Break Fuse LV",
"code": 274
},
{
"name": "Station Disconnect Fuse LV",
"code": 275
},
{
"name": "Station Load Break Fuse LV",
"code": 276
},
{
"name": "Station Load Break Disconnect Fuse LV",
"code": 277
},
{
"name": "Station Disconnect Fuse LV - Controller",
"code": 278
},
{
"name": "Station Load Break Fuse LV - Controller",
"code": 279
},
{
"name": "Station Load Break Disconnect Fuse LV - Controller",
"code": 280
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Type",
"description": "List of valid fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Link_Type",
"description": "Types of fuse links",
"codedValues": [
{
"name": "K",
"code": 10
},
{
"name": "T",
"code": 11
},
{
"name": "MS",
"code": 12
},
{
"name": "QH",
"code": 13
},
{
"name": "Standard",
"code": 14
},
{
"name": "SloFast",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 14,
"name": "Low Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation",
"description": "Low Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery LV",
"code": 281
},
{
"name": "Generator LV",
"code": 283
},
{
"name": "Residential Photovoltaic Solar LV",
"code": 284
},
{
"name": "Wind Turbine LV",
"code": 285
},
{
"name": "AC Wave LV",
"code": 286
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 15,
"name": "Low Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting",
"description": "Low Voltage Lighting",
"codedValues": [
{
"name": "Lighting",
"code": 0
},
{
"name": "Floodlight LV",
"code": 301
},
{
"name": "Streetlight LV",
"code": 302
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Light_Housing_Type",
"description": "Light Housing Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cobra Head",
"code": 1
},
{
"name": "Security",
"code": 2
},
{
"name": "Roadway",
"code": 3
},
{
"name": "Flood",
"code": 4
},
{
"name": "Decorative",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Street_Bulb_Type",
"description": "List of valid bulb types for streetlights",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "High Pressure Sodium (HPS)",
"code": 30
},
{
"name": "Low Pressure Sodium (LPS)",
"code": 31
},
{
"name": "Metal Halide (MH)",
"code": 32
},
{
"name": "Mercury Vapor (MV)",
"code": 33
},
{
"name": "Halogen (HG)",
"code": 34
},
{
"name": "Light Emitting Diode (LED)",
"code": 35
},
{
"name": "Phosphor-Converted Amber LED (PCA)",
"code": 36
},
{
"name": "Narrow-Band Amber LED (NBA)",
"code": 37
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"lightsphotoeye": {"type": "inherited"},
"lightswattage": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 16,
"name": "Low Voltage Lighting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay",
"description": "Low Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator LV",
"code": 321
},
{
"name": "Load Monitor LV",
"code": 322
},
{
"name": "Relay LV",
"code": 323
},
{
"name": "Instrument Transformer LV",
"code": 324
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 17,
"name": "Low Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor",
"description": "Low Voltage Motor",
"codedValues": [
{
"name": "Motor",
"code": 0
},
{
"name": "Single Phase Motor LV",
"code": 341
},
{
"name": "Three Phase Motor LV",
"code": 342
},
{
"name": "DC Motor LV",
"code": 343
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 18,
"name": "Low Voltage Motor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection",
"description": "Low Voltage Network Protection",
"codedValues": [
{
"name": "Network Protector",
"code": 0
},
{
"name": "Network Protector LV",
"code": 361
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 19,
"name": "Low Voltage Network Protection"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion",
"description": "Low Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter LV",
"code": 381
},
{
"name": "Single Phase Rectifier LV",
"code": 382
},
{
"name": "Three Phase Inverter LV",
"code": 383
},
{
"name": "Three Phase Rectifier LV",
"code": 384
},
{
"name": "Single Phase Bidirectional LV",
"code": 386
},
{
"name": "Three Phase Bidirectional LV",
"code": 387
},
{
"name": "Wave Trap LV",
"code": 390
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 20,
"name": "Low Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting",
"description": "Low Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "Mobile Harmonic Filter LV",
"code": 401
},
{
"name": "Mobile Reactor LV",
"code": 402
},
{
"name": "Overhead Capacitor LV",
"code": 403
},
{
"name": "Overhead Harmonic Filter LV",
"code": 404
},
{
"name": "Overhead Reactor LV",
"code": 405
},
{
"name": "Pad Mounted Capacitor LV",
"code": 406
},
{
"name": "Pad Mounted Harmonic Filter LV",
"code": 407
},
{
"name": "Pad Mounted Reactor LV",
"code": 408
},
{
"name": "Station Capacitor LV",
"code": 409
},
{
"name": "Station Harmonic Filter LV",
"code": 410
},
{
"name": "Station Reactor LV",
"code": 411
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 21,
"name": "Low Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service",
"description": "Low Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Single Phase Commercial LV",
"code": 421
},
{
"name": "Single Phase Residential LV",
"code": 422
},
{
"name": "Three Phase Commercial LV",
"code": 423
},
{
"name": "Three Phase Residential LV",
"code": 424
},
{
"name": "Unmetered Load LV",
"code": 425
},
{
"name": "DC Commercial LV",
"code": 426
},
{
"name": "Low Voltage Premise LV",
"code": 427
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 22,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch",
"description": "Low Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Station Disconnect LV",
"code": 431
},
{
"name": "AC Station Load Break LV",
"code": 432
},
{
"name": "AC Station Load Break Disconnect LV",
"code": 433
},
{
"name": "AC Station Disconnect LV - Controller",
"code": 434
},
{
"name": "AC Station Load Break LV - Controller",
"code": 435
},
{
"name": "AC Station Load Break Disconnect LV - Controller",
"code": 436
},
{
"name": "Overhead AC Load Break LV",
"code": 441
},
{
"name": "Overhead AC Disconnect LV",
"code": 442
},
{
"name": "Overhead DC Load Break LV",
"code": 443
},
{
"name": "Overhead DC Disconnect LV",
"code": 444
},
{
"name": "Underground AC Load Break LV",
"code": 445
},
{
"name": "Underground AC Disconnect LV",
"code": 446
},
{
"name": "Underground DC Load Break LV",
"code": 447
},
{
"name": "Underground DC Disconnect LV",
"code": 448
},
{
"name": "Indoor AC Load Break LV",
"code": 449
},
{
"name": "Indoor AC Disconnect LV",
"code": 450
},
{
"name": "Indoor DC Load Break LV",
"code": 451
},
{
"name": "Indoor DC Disconnect LV",
"code": 452
},
{
"name": "Source Selectable Switch LV",
"code": 453
},
{
"name": "Overhead Jumper LV",
"code": 454
},
{
"name": "DC Station LV",
"code": 456
},
{
"name": "AC Station Bypass LV",
"code": 457
},
{
"name": "AC Recloser LV",
"code": 458
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps",
"description": "Low Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "45 A",
"code": 45
},
{
"name": "50 A",
"code": 50
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "300 A",
"code": 300
},
{
"name": "320 A",
"code": 320
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "2500 A",
"code": 2500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 23,
"name": "Low Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer",
"description": "Low Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Single Phase - LV->LV",
"code": 461
},
{
"name": "Three Phase - LV->LV",
"code": 462
},
{
"name": "Three Winding - LV->LV-LV",
"code": 463
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 24,
"name": "Low Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector",
"description": "Low Voltage Connectors",
"codedValues": [
{
"name": "Wire Connector",
"code": 0
},
{
"name": "Ring Terminal LV",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 44,
"name": "Low Voltage Wire Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator",
"description": "Asset Types for Low Voltage Regulating Equipment",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase LV",
"code": 141
},
{
"name": "AC Three Phase LV",
"code": 142
},
{
"name": "DC Regulator LV",
"code": 143
},
{
"name": "Network Load Balancer LV",
"code": 144
},
{
"name": "Frequency Converter LV",
"code": 145
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 45,
"name": "Low Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding LV",
"code": 874
},
{
"name": "DC Transformer Winding LV",
"code": 875
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 46,
"name": "Low Voltage Transformer Winding"
}
],
"subtypes": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tertiarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": null,
"maintby": null,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Ground",
"code": 0
},
{
"name": "Bound",
"code": 31
},
{
"name": "Rod",
"code": 32
},
{
"name": "Voltage Grid",
"code": 33
},
{
"name": "Stray Voltage Isolator",
"code": 34
},
{
"name": "Grounding Switch",
"code": 35
},
{
"name": "Cross Bond",
"code": 36
},
{
"name": "Ground Plate",
"code": 37
},
{
"name": "Ground Joint",
"code": 38
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Type",
"description": "Ground Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bound",
"code": 1
},
{
"name": "Mesh",
"code": 2
},
{
"name": "Rod",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 1,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit",
"description": "High Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor HV",
"code": 41
},
{
"name": "Switch and Breaker HV",
"code": 42
},
{
"name": "Voltage Regulator HV",
"code": 43
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 3,
"name": "High Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation",
"description": "High Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery HV",
"code": 61
},
{
"name": "Biomass HV",
"code": 62
},
{
"name": "Coal HV",
"code": 63
},
{
"name": "Gas Turbine HV",
"code": 64
},
{
"name": "Geothermal HV",
"code": 65
},
{
"name": "Hydro HV",
"code": 66
},
{
"name": "Nuclear HV",
"code": 67
},
{
"name": "Photovoltaic Solar HV",
"code": 68
},
{
"name": "Thermal Solar HV",
"code": 69
},
{
"name": "Wind HV",
"code": 70
},
{
"name": "AC Wave HV",
"code": 71
},
{
"name": "Generator HV",
"code": 72
},
{
"name": "Interconnect HV",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 4,
"name": "High Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse",
"description": "High Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Station Disconnect Fuse HV",
"code": 581
},
{
"name": "AC Station Load Break Fuse HV",
"code": 582
},
{
"name": "AC Load Break Disconnect Fuse HV",
"code": 583
},
{
"name": "AC Load Break Fuse HV - Controller",
"code": 584
},
{
"name": "AC Disconnect Fuse HV - Controller",
"code": 585
},
{
"name": "AC Load Break Disconnect Fuse HV - Controller",
"code": 586
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Continuous Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "3000 A",
"code": 3000
},
{
"name": "6000 A",
"code": 6000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current",
"description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "60 kA",
"code": 60000
},
{
"name": "80 kA",
"code": 80000
},
{
"name": "90 kA",
"code": 90000
},
{
"name": "2 kA",
"code": 2000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 43,
"name": "High Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay",
"description": "High Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator HV",
"code": 80
},
{
"name": "Instrument Transformer HV",
"code": 81
},
{
"name": "Load Monitor HV",
"code": 82
},
{
"name": "Relay HV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Phase_Angle_Offset_Range",
"description": "Phase Offset values 0 - 60",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 5,
"name": "High Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion",
"description": "High Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Inverter HV",
"code": 101
},
{
"name": "Rectifier HV",
"code": 102
},
{
"name": "Bidirectional HV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_DC_Voltage",
"description": "Valid High Voltage Direct Current Voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "270 kV",
"code": 270000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1000 kV",
"code": 1000000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
},
{
"name": "1400 kV",
"code": 1400000
},
{
"name": "1500 kV",
"code": 1500000
},
{
"name": "1800 kV",
"code": 1800000
},
{
"name": "2500 kV",
"code": 2500000
},
{
"name": "3000 kV",
"code": 3000000
},
{
"name": "4000 kV",
"code": 4000000
},
{
"name": "5000 kV",
"code": 5000000
},
{
"name": "6000 kV",
"code": 6000000
},
{
"name": "6400 kV",
"code": 6400000
},
{
"name": "7200 kV",
"code": 7200000
},
{
"name": "8000 kV",
"code": 8000000
},
{
"name": "10000 kV",
"code": 10000000
},
{
"name": "12000 kV",
"code": 12000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Generate_Watts",
"description": "Maximum Generation Station Watts output",
"codedValues": [
{
"name": "Idle",
"code": -1
},
{
"name": "Unknown",
"code": 0
},
{
"name": "540 MW",
"code": 540
},
{
"name": "1540 MW",
"code": 1540
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 6,
"name": "High Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting",
"description": "High Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Capacitor HV",
"code": 121
},
{
"name": "AC Wave Trap HV",
"code": 122
},
{
"name": "AC Reactor HV",
"code": 123
},
{
"name": "DC Capacitor HV",
"code": 124
},
{
"name": "DC Reactor HV",
"code": 125
},
{
"name": "Synchronous Condenser HV",
"code": 126
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Power_Factor_Correcting_Type",
"description": "Type of Power Factor Correcting Equipment",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Maximum_Current",
"description": "Maximum Current Range Domain",
"range": [
0,
15000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_KVAR",
"description": "Domain for valid kVAR rating for High Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "600 kvar",
"code": 600000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 7,
"name": "High Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator",
"description": "High Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase HV",
"code": 171
},
{
"name": "AC Three Phase HV",
"code": 172
},
{
"name": "DC Regulator HV",
"code": 173
},
{
"name": "Frequency Converter HV",
"code": 174
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Regulator_VA",
"description": "List of valid High Voltage Regulator in volt amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".5 MVA",
"code": 500000
},
{
"name": "1 MVA",
"code": 1000000
},
{
"name": "1.5 MVA",
"code": 1500000
},
{
"name": "2 MVA",
"code": 2000000
},
{
"name": "2.5 MVA",
"code": 2500000
},
{
"name": "3 MVA",
"code": 3000000
},
{
"name": "3.5 MVA",
"code": 3500000
},
{
"name": "4 MVA",
"code": 4000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 8,
"name": "High Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service",
"description": "High Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "AC Metering HV",
"code": 161
},
{
"name": "DC Metering HV",
"code": 162
},
{
"name": "High Voltage Premise HV",
"code": 163
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Service_Load_kW",
"description": "Range domain of valid kW loads",
"range": [
0,
500000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 9,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch",
"description": "High Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Circuit Breaker HV",
"code": 181
},
{
"name": "AC Disconnect HV",
"code": 182
},
{
"name": "AC Switchgear HV",
"code": 183
},
{
"name": "DC Circuit Breaker HV",
"code": 184
},
{
"name": "DC Disconnect HV",
"code": 185
},
{
"name": "DC Switchgear HV",
"code": 186
},
{
"name": "AC Bus Tie Breaker HV",
"code": 187
},
{
"name": "DC Bus Tie Breaker HV",
"code": 188
},
{
"name": "AC Disconnect - Grounded HV",
"code": 189
},
{
"name": "AC Breaker Bypass HV",
"code": 190
},
{
"name": "AC Circuit Breaker HV - Controller",
"code": 191
},
{
"name": "AC Station Disconnect HV",
"code": 192
},
{
"name": "AC Station Load Break Disconnect HV - Controller",
"code": 193
},
{
"name": "DC Circuit Breaker HV - Controller",
"code": 194
},
{
"name": "AC Disconnect HV - Controller",
"code": 195
},
{
"name": "AC Grounding HV",
"code": 196
},
{
"name": "AC Thyristor HV",
"code": 197
},
{
"name": "DC Thyristor HV",
"code": 198
},
{
"name": "AC Transfer Switch HV",
"code": 199
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps",
"description": "High Voltage Switch Interrupting Current",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps",
"description": "High Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": ".6 kA",
"code": 600
},
{
"name": "1.2 kA",
"code": 1200
},
{
"name": "1.25 kA",
"code": 1250
},
{
"name": "1.6 kA",
"code": 1600
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 10,
"name": "High Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer",
"description": "High Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "AC Single Phase - HV->MV",
"code": 201
},
{
"name": "AC Three Phase - HV->MV",
"code": 202
},
{
"name": "DC Power - HV->HV",
"code": 203
},
{
"name": "Grounding Transformer - HV->MV",
"code": 204
},
{
"name": "Station - HV->MV",
"code": 205
},
{
"name": "Station Three Winding - HV->HV-HV",
"code": 206
},
{
"name": "Station Three Winding - HV->HV-MV",
"code": 207
},
{
"name": "Phase Control - HV->HV",
"code": 208
},
{
"name": "Station Three Winding - HV->HV-LV",
"code": 209
},
{
"name": "Station Step Up - MV->HV",
"code": 210
},
{
"name": "Station Step - HV->HV",
"code": 211
},
{
"name": "Station Three Winding - HV->MV-MV",
"code": 212
},
{
"name": "Station Three Winding - HV->MV-LV",
"code": 213
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Number_of_Phases",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Watts",
"description": "Maximum Load in Watts",
"range": [
0,
20000000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"tapmaxchange": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Transformer_VA",
"description": "List of valid High Voltage Transformer Power Rating",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5.5 MVA",
"code": 5500000
},
{
"name": "74 MVA",
"code": 74000000
},
{
"name": "75 MVA",
"code": 75000000
},
{
"name": "200 MVA",
"code": 200000000
},
{
"name": "300 MVA",
"code": 300000000
},
{
"name": "350 MVA",
"code": 350000000
},
{
"name": "400 MVA",
"code": 400000000
},
{
"name": "500 MVA",
"code": 500000000
},
{
"name": "550 MVA",
"code": 550000000
},
{
"name": "650 MVA",
"code": 650000000
},
{
"name": "750 MVA",
"code": 750000000
},
{
"name": "1000 MVA",
"code": 1000000000
},
{
"name": "1200 MVA",
"code": 1200000000
},
{
"name": "1500 MVA",
"code": 1500000000
},
{
"name": "100 MVA",
"code": 10000000
},
{
"name": "200 MVA",
"code": 20000000
},
{
"name": "300 MVA",
"code": 30000000
},
{
"name": "350 MVA",
"code": 35000000
},
{
"name": "400 MVA",
"code": 40000000
},
{
"name": "500 MVA",
"code": 50000000
},
{
"name": "550 MVA",
"code": 55000000
},
{
"name": "650 MVA",
"code": 65000000
},
{
"name": "1000 MVA",
"code": 100000000
},
{
"name": "1200 MVA",
"code": 120000000
},
{
"name": "1500 MVA",
"code": 150000000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_High_Voltage_Load_Loss",
"description": "Valid Load Loss Range for High Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 11,
"name": "High Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Line Hardware",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 61,
"name": "High Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding HV",
"code": 871
},
{
"name": "DC Transformer Winding HV",
"code": 872
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 48,
"name": "High Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker",
"description": "Medium Voltage Circuit Breaker",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "Isolator Switch MV",
"code": 501
},
{
"name": "Single Phase Circuit Breaker MV",
"code": 502
},
{
"name": "Three Phase Circuit Breaker MV",
"code": 503
},
{
"name": "Single Phase Circuit Breaker MV - Controller",
"code": 512
},
{
"name": "Three Phase Circuit Breaker MV - Controller",
"code": 513
},
{
"name": "Network Protector MV",
"code": 515
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees",
"description": "Positive and Negative degrees in whole units",
"range": [
-180,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Medium Voltage Circuit Breaker Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Medium Voltage Circuit Breaker Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "1250 A",
"code": 1250
},
{
"name": "1600 A",
"code": 1600
},
{
"name": "2000 A",
"code": 2000
},
{
"name": "2500 A",
"code": 2500
},
{
"name": "3000 A",
"code": 3000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 26,
"name": "Medium Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit",
"description": "Medium Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Capacitor MV",
"code": 521
},
{
"name": "Circuit Breaker MV",
"code": 522
},
{
"name": "Recloser MV",
"code": 523
},
{
"name": "Transfer Switch Controller MV",
"code": 524
},
{
"name": "Regulator MV",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 27,
"name": "Medium Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow",
"description": "Medium Voltage Elbow",
"codedValues": [
{
"name": "Elbow",
"code": 0
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Load Break Feedthru MV",
"code": 541
},
{
"name": "Load Break Junction MV",
"code": 542
},
{
"name": "Single Phase Dead Break MV",
"code": 543
},
{
"name": "Single Phase Load Break MV",
"code": 544
},
{
"name": "Three Phase Dead Break MV",
"code": 545
},
{
"name": "Three Phase Load Break MV",
"code": 546
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 28,
"name": "Medium Voltage Elbow"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse",
"description": "Medium Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Bayonet Fuse MV",
"code": 561
},
{
"name": "Fault Limiter Fuse MV",
"code": 562
},
{
"name": "Indoor Fuse MV",
"code": 563
},
{
"name": "Overhead Cutout Disconnect Fuse MV",
"code": 564
},
{
"name": "Overhead Cutout Load Break Fuse MV",
"code": 565
},
{
"name": "Overhead Cutout Sectionalizer Fuse MV",
"code": 566
},
{
"name": "Overhead Cutout Solid Blade Fuse MV",
"code": 567
},
{
"name": "Cabinet Fuse MV",
"code": 568
},
{
"name": "Underground Fuse MV",
"code": 569
},
{
"name": "Underground Disconnect Fuse MV",
"code": 570
},
{
"name": "Underground Load Break Fuse MV",
"code": 571
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV",
"code": 572
},
{
"name": "Overhead Cutout Load Break Fuse MV - Controller",
"code": 573
},
{
"name": "Overhead Cutout Disconnect Fuse MV - Controller",
"code": 574
},
{
"name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller",
"code": 575
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Rating",
"description": "List of valid Electric Medium Voltage Fuse Ratingsl",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "E",
"code": 2
},
{
"name": "R",
"code": 3
},
{
"name": "PT",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Type",
"description": "Medium Voltage fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridged",
"code": 1
},
{
"name": "Burndy",
"code": 2
},
{
"name": "Bussman",
"code": 3
},
{
"name": "Cooper Elf",
"code": 4
},
{
"name": "D & W",
"code": 5
},
{
"name": "EJO-1",
"code": 6
},
{
"name": "Fault Tamer",
"code": 7
},
{
"name": "Kearney",
"code": 8
},
{
"name": "Kearney 200",
"code": 9
},
{
"name": "Kearney QA",
"code": 10
},
{
"name": "RTE B",
"code": 11
},
{
"name": "S & C",
"code": 12
},
{
"name": "S & C SM-4",
"code": 13
},
{
"name": "X-Limiter",
"code": 14
},
{
"name": "NX",
"code": 15
},
{
"name": "CL",
"code": 16
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "250 A",
"code": 250
},
{
"name": "500 A",
"code": 500
},
{
"name": "600 A",
"code": 600
},
{
"name": "1080 A",
"code": 1080
},
{
"name": "8000 A",
"code": 8000
},
{
"name": "10000 A",
"code": 10000
},
{
"name": "12000 A",
"code": 12000
},
{
"name": "16000 A",
"code": 16000
},
{
"name": "20000 A",
"code": 20000
},
{
"name": "40000 A",
"code": 40000
},
{
"name": "60000 A",
"code": 60000
},
{
"name": "80000 A",
"code": 80000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "65 A",
"code": 65
},
{
"name": "80 A",
"code": 80
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "150 A",
"code": 150
},
{
"name": "175 A",
"code": 175
},
{
"name": "180 A",
"code": 180
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "250 A",
"code": 250
},
{
"name": "300 A",
"code": 300
},
{
"name": "350 A",
"code": 350
},
{
"name": "400 A",
"code": 400
},
{
"name": "450 A",
"code": 450
},
{
"name": "500 A",
"code": 500
},
{
"name": "550 A",
"code": 550
},
{
"name": "600 A",
"code": 600
},
{
"name": "140 A",
"code": 140
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 29,
"name": "Medium Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation",
"description": "Medium Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "AC Wave MV",
"code": 110
},
{
"name": "Battery MV",
"code": 111
},
{
"name": "Biomass MV",
"code": 112
},
{
"name": "Generator MV",
"code": 113
},
{
"name": "Gas Turbine MV",
"code": 114
},
{
"name": "Geothermal MV",
"code": 115
},
{
"name": "Hydro MV",
"code": 116
},
{
"name": "Wind MV",
"code": 117
},
{
"name": "Photovoltaic Solar MV",
"code": 118
},
{
"name": "Thermal Solar MV",
"code": 119
},
{
"name": "Interconnect MV",
"code": 120
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 30,
"name": "Medium Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay",
"description": "Medium Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator MV",
"code": 601
},
{
"name": "Instrument Transformer MV",
"code": 602
},
{
"name": "Programmable Logic Unit MV",
"code": 603
},
{
"name": "Remote Terminal Unit MV",
"code": 604
},
{
"name": "SCADA Load Monitor MV",
"code": 605
},
{
"name": "SCADA Weather Station MV",
"code": 606
},
{
"name": "Relay MV",
"code": 607
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 31,
"name": "Medium Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump",
"description": "Medium Voltage Motor and Pump",
"codedValues": [
{
"name": "Motor and Pump",
"code": 0
},
{
"name": "Single Phase Motor MV",
"code": 621
},
{
"name": "Single Phase Pump MV",
"code": 622
},
{
"name": "Three Phase Motor MV",
"code": 623
},
{
"name": "Three Phase Pump MV",
"code": 624
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 32,
"name": "Medium Voltage Motor and Pump"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion",
"description": "Medium Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter MV",
"code": 641
},
{
"name": "Single Phase Rectifier MV",
"code": 642
},
{
"name": "Three Phase Inverter MV",
"code": 643
},
{
"name": "Three Phase Rectifier MV",
"code": 644
},
{
"name": "Single Phase Bidirectional MV",
"code": 645
},
{
"name": "Three Phase Bidirectional MV",
"code": 646
},
{
"name": "Wave Trap MV",
"code": 647
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 33,
"name": "Medium Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting",
"description": "Medium Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Mobile Capacitor MV",
"code": 661
},
{
"name": "Overhead Single Phase Capacitor MV",
"code": 664
},
{
"name": "Overhead Three Phase Capacitor MV",
"code": 665
},
{
"name": "Overhead Harmonic Filter MV",
"code": 666
},
{
"name": "Overhead Reactor MV",
"code": 667
},
{
"name": "Pad Mounted Single Phase Capacitor MV",
"code": 668
},
{
"name": "Pad Mounted Three Phase Capacitor MV",
"code": 669
},
{
"name": "Mobile Harmonic Filter MV",
"code": 671
},
{
"name": "Mobile Reactor MV",
"code": 672
},
{
"name": "Pad Mounted Harmonic Filter MV",
"code": 673
},
{
"name": "Pad Mounted Reactor MV",
"code": 674
},
{
"name": "Station Capacitor MV",
"code": 675
},
{
"name": "Station Harmonic Filter MV",
"code": 676
},
{
"name": "Station Reactor MV",
"code": 677
},
{
"name": "Synchronous Condenser MV",
"code": 678
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_KVAR",
"description": "Domain of valid kVAR ratings for Medium Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "5 kvar",
"code": 5000
},
{
"name": "10 kvar",
"code": 10000
},
{
"name": "20 kvar",
"code": 20000
},
{
"name": "30 kvar",
"code": 30000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "300 kvar",
"code": 300000
},
{
"name": "400 kvar",
"code": 400000
},
{
"name": "500 kvar",
"code": 500000
},
{
"name": "600 kvar",
"code": 600000
},
{
"name": "800 kvar",
"code": 800000
},
{
"name": "1200 kvar",
"code": 1200000
},
{
"name": "1500 kvar",
"code": 1500000
},
{
"name": "1800 kvar",
"code": 1800000
},
{
"name": "2400 kvar",
"code": 2400000
},
{
"name": "3600 kvar",
"code": 3600000
},
{
"name": "900 kvar",
"code": 900000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 34,
"name": "Medium Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator",
"description": "Medium Voltage Regulator",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Overhead Single Phase VR MV",
"code": 681
},
{
"name": "Overhead Three Phase VR MV",
"code": 683
},
{
"name": "Pad Mounted Single Phase VR MV",
"code": 685
},
{
"name": "Pad Mounted Three Phase VR MV",
"code": 687
},
{
"name": "Frequency Converter MV",
"code": 688
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Regulator_VA",
"description": "Medium Voltage Regulator VA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "38 kVA",
"code": 38000
},
{
"name": "38.1 kVA",
"code": 38100
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "57 kVA",
"code": 57000
},
{
"name": "57.2 kVA",
"code": 57200
},
{
"name": "69 kVA",
"code": 69000
},
{
"name": "72 kVA",
"code": 72000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "76 kVA",
"code": 76000
},
{
"name": "76.2 kVA",
"code": 76200
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "114 kVA",
"code": 114000
},
{
"name": "114.3 kVA",
"code": 114300
},
{
"name": "124.8 kVA",
"code": 124800
},
{
"name": "138 kVA",
"code": 138000
},
{
"name": "144 kVA",
"code": 144000
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "152 kVA",
"code": 152000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "171.6 kVA",
"code": 171600
},
{
"name": "172.5 kVA",
"code": 172500
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "207 kVA",
"code": 207000
},
{
"name": "216 kVA",
"code": 216000
},
{
"name": "219 kVA",
"code": 219000
},
{
"name": "228.6 kVA",
"code": 228600
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "276 kVA",
"code": 276000
},
{
"name": "288 kVA",
"code": 288000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "332 kVA",
"code": 332000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342.9 kVA",
"code": 342900
},
{
"name": "345 kVA",
"code": 345000
},
{
"name": "400 kVA",
"code": 400000
},
{
"name": "414 kVA",
"code": 414000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "432 kVA",
"code": 432000
},
{
"name": "456 kVA",
"code": 456000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "517.5 kVA",
"code": 517500
},
{
"name": "518 kVA",
"code": 518000
},
{
"name": "552 kVA",
"code": 552000
},
{
"name": "576 kVA",
"code": 576000
},
{
"name": "600 kVA",
"code": 600000
},
{
"name": "621 kVA",
"code": 621000
},
{
"name": "657 kVA",
"code": 657000
},
{
"name": "667 kVA",
"code": 667000
},
{
"name": "690 kVA",
"code": 690000
},
{
"name": "700 kVA",
"code": 700000
},
{
"name": "720 kVA",
"code": 720000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "828 kVA",
"code": 828000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "863 kVA",
"code": 863000
},
{
"name": "864 kVA",
"code": 864000
},
{
"name": "996 kVA",
"code": 996000
},
{
"name": "999 kVA",
"code": 999000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1035 kVA",
"code": 1035000
},
{
"name": "1145 kVA",
"code": 1145000
},
{
"name": "1200 kVA",
"code": 1200000
},
{
"name": "1242 kVA",
"code": 1242000
},
{
"name": "1248 kVA",
"code": 1248000
},
{
"name": "1296 kVA",
"code": 1296000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1554 kVA",
"code": 1554000
},
{
"name": "1656 kVA",
"code": 1656000
},
{
"name": "1728 kVA",
"code": 1728000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2001 kVA",
"code": 2001000
},
{
"name": "2070 kVA",
"code": 2070000
},
{
"name": "2100 kVA",
"code": 2100000
},
{
"name": "2160 kVA",
"code": 2160000
},
{
"name": "2499 kVA",
"code": 2499000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "2589 kVA",
"code": 2589000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3462 kVA",
"code": 3462000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 35,
"name": "Medium Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service",
"description": "Medium Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Primary Meter - Industrial Customer MV",
"code": 701
},
{
"name": "Primary Meter - Utility Customer MV",
"code": 702
},
{
"name": "Primary Meter Circuit Source MV",
"code": 703
},
{
"name": "Medium Voltage Premise MV",
"code": 704
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 36,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser",
"description": "Medium Voltage Recloser Asset Types",
"codedValues": [
{
"name": "Recloser",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Recloser MV",
"code": 730
},
{
"name": "Overhead Three Phase Recloser MV - Controller",
"code": 734
},
{
"name": "Pad Mounted Three Phase Recloser MV - Controller",
"code": 738
},
{
"name": "Overhead Three Phase Recloser MV",
"code": 744
},
{
"name": "Pad Mounted Single Phase Recloser MV",
"code": 747
},
{
"name": "Pad Mounted Three Phase Recloser MV",
"code": 748
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps",
"description": "Medium Voltage Recloser Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 kA",
"code": 2000
},
{
"name": "2.5 kA",
"code": 2500
},
{
"name": "3 kA",
"code": 3000
},
{
"name": "4 kA",
"code": 4000
},
{
"name": "6 kA",
"code": 6000
},
{
"name": "8 kA",
"code": 8000
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps",
"description": "Medium Voltage Recloser Continuous Amps Ratings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "280 A",
"code": 280
},
{
"name": "400 A",
"code": 400
},
{
"name": "560 A",
"code": 560
},
{
"name": "600 A",
"code": 600
},
{
"name": "630 A",
"code": 630
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 41,
"name": "Medium Voltage Recloser"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer",
"description": "Medium Voltage Secitionalizer",
"codedValues": [
{
"name": "Sectionalizer",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "Overhead Single Phase Sectionalizer MV",
"code": 731
},
{
"name": "Overhead Three Phase Sectionalizer MV",
"code": 745
},
{
"name": "Pad Mounted Single Phase Sectionalizer MV",
"code": 749
},
{
"name": "Pad Mounted Three Phase Sectionalizer MV",
"code": 750
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 42,
"name": "Medium Voltage Sectionalizer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch",
"description": "Medium Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "Cabinet Bypass MV",
"code": 721
},
{
"name": "Cabinet Switch MV",
"code": 722
},
{
"name": "Cabinet Switch - Grounded MV",
"code": 723
},
{
"name": "Overhead Bypass MV",
"code": 724
},
{
"name": "Overhead Grounding Switch MV",
"code": 725
},
{
"name": "Overhead Jumper MV",
"code": 726
},
{
"name": "Station Grounding MV",
"code": 727
},
{
"name": "Overhead Single Phase Disconnect MV",
"code": 728
},
{
"name": "Overhead Single Phase Load Break MV",
"code": 729
},
{
"name": "Overhead Three Phase Disconnect MV",
"code": 732
},
{
"name": "Overhead Three Phase Load Break MV",
"code": 733
},
{
"name": "Pad Mounted Fault Interrupter MV",
"code": 746
},
{
"name": "Station Single Phase Disconnect MV",
"code": 751
},
{
"name": "Station Disconnect MV",
"code": 752
},
{
"name": "T Blade MV",
"code": 753
},
{
"name": "V Blade MV",
"code": 754
},
{
"name": "Underground Single Phase Disconnect MV",
"code": 755
},
{
"name": "Underground Single Phase Load Break MV",
"code": 758
},
{
"name": "Underground Three Phase Disconnect MV",
"code": 759
},
{
"name": "Underground Three Phase Load Break MV",
"code": 760
},
{
"name": "Underground Transfer Switch MV",
"code": 761
},
{
"name": "Bus Tie Breaker MV",
"code": 765
},
{
"name": "Station Load Break MV",
"code": 766
},
{
"name": "Station Disconnect - Grounded MV",
"code": 768
},
{
"name": "Station Load Break Disconnect MV",
"code": 769
},
{
"name": "Station Disconnect MV - Controller",
"code": 770
},
{
"name": "Station Load Break MV - Controller",
"code": 771
},
{
"name": "Station Load Break Disconnect MV - Controller",
"code": 772
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps",
"description": "Medium Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "16 kA",
"code": 16000
},
{
"name": "25 kA",
"code": 25000
},
{
"name": "29 kA",
"code": 29000
},
{
"name": "31.5 kA",
"code": 31500
},
{
"name": "40 kA",
"code": 40000
},
{
"name": "50 kA",
"code": 50000
},
{
"name": "63 kA",
"code": 63000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps",
"description": "Medium Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 A",
"code": 600
},
{
"name": "900 A",
"code": 900
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12000,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 37,
"name": "Medium Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer",
"description": "Medium Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Grounding Transformer - MV->MV",
"code": 781
},
{
"name": "Mobile Single Phase - MV->LV",
"code": 782
},
{
"name": "Mobile Three Phase - MV->LV",
"code": 783
},
{
"name": "Network - MV->LV",
"code": 784
},
{
"name": "Overhead Single Phase - MV->LV",
"code": 785
},
{
"name": "Station - MV->LV",
"code": 786
},
{
"name": "Station Three Winding - MV->LV-LV",
"code": 787
},
{
"name": "Overhead Three Phase - MV->LV",
"code": 788
},
{
"name": "Pad Mounted Single Phase - MV->LV",
"code": 789
},
{
"name": "Station Three Winding - MV->MV-LV",
"code": 790
},
{
"name": "Pad Mounted Three Phase - MV->LV",
"code": 792
},
{
"name": "Submersible Single Phase - MV->LV",
"code": 793
},
{
"name": "Submersible Three Phase - MV->LV",
"code": 794
},
{
"name": "Overhead Open Delta - MV->LV",
"code": 795
},
{
"name": "Overhead Open Wye - MV->LV",
"code": 796
},
{
"name": "Pad Mounted Open Delta - MV->LV",
"code": 797
},
{
"name": "Pad Mounted Open Wye - MV->LV",
"code": 798
},
{
"name": "Overhead Single Phase Step - MV<->MV",
"code": 801
},
{
"name": "Overhead Three Phase Step - MV<->MV",
"code": 802
},
{
"name": "Overhead Single Phase Step - MV->MV",
"code": 803
},
{
"name": "Overhead Three Phase Step - MV->MV",
"code": 804
},
{
"name": "Pad Mounted Single Phase Step - MV<->MV",
"code": 805
},
{
"name": "Pad Mounted Three Phase Step - MV<->MV",
"code": 806
},
{
"name": "Pad Mounted Single Phase Step - MV->MV",
"code": 807
},
{
"name": "Pad Mounted Three Phase Step - MV->MV",
"code": 808
},
{
"name": "Submersible Single Phase Step - MV<->MV",
"code": 809
},
{
"name": "Overhead Three Phase Wye Delta Closed Ground",
"code": 810
},
{
"name": "Submersible Single Phase Step - MV->MV",
"code": 811
},
{
"name": "Pad Mounted Three Phase Wye Delta Closed Ground",
"code": 812
},
{
"name": "Station Step - MV->MV",
"code": 813
},
{
"name": "Station Step - MV<->MV",
"code": 814
},
{
"name": "Station Step Three Winding - MV->MV-MV",
"code": 815
},
{
"name": "Overhead Three Phase Step Up - LV->MV",
"code": 816
},
{
"name": "Overhead Three Phase Step Up - LV<->MV",
"code": 817
},
{
"name": "Station Step Up - LV->MV",
"code": 818
},
{
"name": "Station Step Up - LV<->MV",
"code": 819
},
{
"name": "Pad Mounted Three Phase Step Up - LV->MV",
"code": 820
},
{
"name": "Pad Mounted Three Phase Step Up - LV<->MV",
"code": 821
},
{
"name": "Overhead Single Phase Step Up - LV->MV",
"code": 822
},
{
"name": "Overhead Single Phase Step Up - LV<->MV",
"code": 823
},
{
"name": "Pad Mounted Single Phase Step Up - LV->MV",
"code": 824
},
{
"name": "Pad Mounted Single Phase Step Up - LV<->MV",
"code": 825
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Transformer_VA",
"description": "List of volt amps for devices, displayed in kilovolt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "1.0 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7 kVA",
"code": 7000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "20 kVA",
"code": 20000
},
{
"name": "25 kVA",
"code": 25000
},
{
"name": "30 kVA",
"code": 30000
},
{
"name": "37.5 kVA",
"code": 37500
},
{
"name": "45 kVA",
"code": 45000
},
{
"name": "50 kVA",
"code": 50000
},
{
"name": "75 kVA",
"code": 75000
},
{
"name": "100 kVA",
"code": 100000
},
{
"name": "112.5 kVA",
"code": 112500
},
{
"name": "150 kVA",
"code": 150000
},
{
"name": "167 kVA",
"code": 167000
},
{
"name": "200 kVA",
"code": 200000
},
{
"name": "225 kVA",
"code": 225000
},
{
"name": "250 kVA",
"code": 250000
},
{
"name": "300 kVA",
"code": 300000
},
{
"name": "333 kVA",
"code": 333000
},
{
"name": "342 kVA",
"code": 342000
},
{
"name": "375 kVA",
"code": 375000
},
{
"name": "416 kVA",
"code": 416000
},
{
"name": "450 kVA",
"code": 450000
},
{
"name": "500 kVA",
"code": 500000
},
{
"name": "666 kVA",
"code": 666000
},
{
"name": "750 kVA",
"code": 750000
},
{
"name": "833 kVA",
"code": 833000
},
{
"name": "966 kVA",
"code": 966000
},
{
"name": "1000 kVA",
"code": 1000000
},
{
"name": "1250 kVA",
"code": 1250000
},
{
"name": "1500 kVA",
"code": 1500000
},
{
"name": "1750 kVA",
"code": 1750000
},
{
"name": "2000 kVA",
"code": 2000000
},
{
"name": "2500 kVA",
"code": 2500000
},
{
"name": "3000 kVA",
"code": 3000000
},
{
"name": "3500 kVA",
"code": 3500000
},
{
"name": "3750 kVA",
"code": 3750000
},
{
"name": "5000 kVA",
"code": 5000000
},
{
"name": "7000 kVA",
"code": 7000000
},
{
"name": "7500 kVA",
"code": 7500000
},
{
"name": "10000 kVA",
"code": 10000000
},
{
"name": "12000 kVA",
"code": 12000000
},
{
"name": "4000 kVA",
"code": 4000000
},
{
"name": "4250 kVA",
"code": 4250000
},
{
"name": "4500 kVA",
"code": 4500000
},
{
"name": "4750 kVA",
"code": 4750000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": 60,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": 2,
"nominalvoltage": 12470,
"nominalvoltagelg": 7200,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": "_CENTERTAPLOADMIX",
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 38,
"name": "Medium Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware",
"description": "Asset Types for equipment that connects electric lines to towers and poles",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Damper",
"code": 834
},
{
"name": "Spacer",
"code": 836
},
{
"name": "Aerial Marker",
"code": 837
},
{
"name": "Buried Cable Marker",
"code": 838
},
{
"name": "Submerged Cable Marker",
"code": 839
},
{
"name": "Overhead Water Crossing Marker",
"code": 840
},
{
"name": "Airflow Spoiler",
"code": 841
},
{
"name": "Bird Diverter",
"code": 842
},
{
"name": "Line Weight",
"code": 843
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Cable_Hardware_Type",
"description": "Types of cable hardward",
"codedValues": [
{
"name": "Brace",
"code": 1
},
{
"name": "Suspension",
"code": 2
},
{
"name": "Line Post",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 62,
"name": "Medium Voltage Line Hardware"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "Transformer Winding MV",
"code": 873
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 47,
"name": "Medium Voltage Transformer Winding"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker",
"description": "Asset Types for Low Voltage Circuit Breakers",
"codedValues": [
{
"name": "Circuit Breaker",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Circuit Breaker LV",
"code": 471
},
{
"name": "DC Circuit Breaker LV",
"code": 472
},
{
"name": "AC Circuit Breaker LV - Controller",
"code": 473
},
{
"name": "DC Circuit Breaker LV - Controller",
"code": 474
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps",
"description": "Low Voltage Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps",
"description": "Low Voltage Circuit Breaker Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "600 A",
"code": 600
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 40,
"name": "Low Voltage Circuit Breaker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit",
"description": "Low Voltage Controller",
"codedValues": [
{
"name": "Control Unit",
"code": 0
},
{
"name": "Control Unit LV",
"code": 241
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Closing_Mode",
"description": "Device Closing Mode",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Normal Reclose",
"code": 1
},
{
"name": "Remote Block",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 13,
"name": "Low Voltage Control Unit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse",
"description": "Low Voltage Fuse",
"codedValues": [
{
"name": "Fuse",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "Service Fuse Load Break LV",
"code": 259
},
{
"name": "Service Fuse Disconnect LV",
"code": 260
},
{
"name": "AC Overhead Fuse LV",
"code": 261
},
{
"name": "AC Underground Fuse LV",
"code": 262
},
{
"name": "DC Overhead Fuse LV",
"code": 263
},
{
"name": "DC Underground Fuse LV",
"code": 264
},
{
"name": "AC Overhead Load Break Fuse LV",
"code": 265
},
{
"name": "AC Overhead Fuse LV - Controller",
"code": 266
},
{
"name": "AC Underground Load Break Fuse LV",
"code": 267
},
{
"name": "AC Underground Fuse LV - Controller",
"code": 268
},
{
"name": "DC Overhead Fuse LV - Controller",
"code": 269
},
{
"name": "DC Underground Fuse LV - Controller",
"code": 270
},
{
"name": "AC Overhead Cutout Load Break Disconnect Fuse LV",
"code": 271
},
{
"name": "AC Overhead Cutout Load Break Fuse LV - Controller",
"code": 272
},
{
"name": "AC Overhead Cutout Disconnect Fuse LV - Controller",
"code": 273
},
{
"name": "AC Overhead Cutout Load Break Fuse LV",
"code": 274
},
{
"name": "Station Disconnect Fuse LV",
"code": 275
},
{
"name": "Station Load Break Fuse LV",
"code": 276
},
{
"name": "Station Load Break Disconnect Fuse LV",
"code": 277
},
{
"name": "Station Disconnect Fuse LV - Controller",
"code": 278
},
{
"name": "Station Load Break Fuse LV - Controller",
"code": 279
},
{
"name": "Station Load Break Disconnect Fuse LV - Controller",
"code": 280
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Type",
"description": "List of valid fuse types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Kearney A",
"code": 17
},
{
"name": "Kearney B",
"code": 18
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Link_Type",
"description": "Types of fuse links",
"codedValues": [
{
"name": "K",
"code": 10
},
{
"name": "T",
"code": 11
},
{
"name": "MS",
"code": 12
},
{
"name": "QH",
"code": 13
},
{
"name": "Standard",
"code": 14
},
{
"name": "SloFast",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 14,
"name": "Low Voltage Fuse"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation",
"description": "Low Voltage Generation",
"codedValues": [
{
"name": "Generation",
"code": 0
},
{
"name": "Battery LV",
"code": 281
},
{
"name": "Generator LV",
"code": 283
},
{
"name": "Residential Photovoltaic Solar LV",
"code": 284
},
{
"name": "Wind Turbine LV",
"code": 285
},
{
"name": "AC Wave LV",
"code": 286
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Generator_Control_Type",
"description": "Generator Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed",
"code": 1
},
{
"name": "Voltage",
"code": 2
},
{
"name": "Swing",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "codedValue",
"name": "WS1_Electric_Generation_Pole_Count",
"description": "Generator Pole count",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2 Pole",
"code": 2
},
{
"name": "4 Pole",
"code": 4
},
{
"name": "6 Pole",
"code": 6
},
{
"name": "8 Pole",
"code": 8
},
{
"name": "10 Pole",
"code": 10
},
{
"name": "12 Pole",
"code": 12
},
{
"name": "14 Pole",
"code": 14
},
{
"name": "16 Pole",
"code": 16
},
{
"name": "18 Pole",
"code": 18
},
{
"name": "20 Pole",
"code": 20
},
{
"name": "40 Pole",
"code": 40
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Fuel_Type",
"description": "Generator Fuel Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Ethenaol",
"code": 1
},
{
"name": "Gasoline",
"code": 2
},
{
"name": "Hydrogen",
"code": 3
},
{
"name": "Natural Gas",
"code": 4
},
{
"name": "Hydro",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 15,
"name": "Low Voltage Generation"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting",
"description": "Low Voltage Lighting",
"codedValues": [
{
"name": "Lighting",
"code": 0
},
{
"name": "Floodlight LV",
"code": 301
},
{
"name": "Streetlight LV",
"code": 302
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Light_Housing_Type",
"description": "Light Housing Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cobra Head",
"code": 1
},
{
"name": "Security",
"code": 2
},
{
"name": "Roadway",
"code": 3
},
{
"name": "Flood",
"code": 4
},
{
"name": "Decorative",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Street_Bulb_Type",
"description": "List of valid bulb types for streetlights",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "High Pressure Sodium (HPS)",
"code": 30
},
{
"name": "Low Pressure Sodium (LPS)",
"code": 31
},
{
"name": "Metal Halide (MH)",
"code": 32
},
{
"name": "Mercury Vapor (MV)",
"code": 33
},
{
"name": "Halogen (HG)",
"code": 34
},
{
"name": "Light Emitting Diode (LED)",
"code": 35
},
{
"name": "Phosphor-Converted Amber LED (PCA)",
"code": 36
},
{
"name": "Narrow-Band Amber LED (NBA)",
"code": 37
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"lightsphotoeye": {"type": "inherited"},
"lightswattage": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 16,
"name": "Low Voltage Lighting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay",
"description": "Low Voltage Line Monitor and Relay",
"codedValues": [
{
"name": "Line Monitor and Relay",
"code": 0
},
{
"name": "Fault Indicator LV",
"code": 321
},
{
"name": "Load Monitor LV",
"code": 322
},
{
"name": "Relay LV",
"code": 323
},
{
"name": "Instrument Transformer LV",
"code": 324
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "range",
"name": "WS1_Electric_Voltage_Offset",
"description": "Voltage Offset Range",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_RTU_Data_Type",
"description": "RTU Data collector data format",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Analog",
"code": 1
},
{
"name": "Digital",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Maximum_Voltage_Change",
"description": "Maximum Voltage Change",
"range": [
0,
10000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"p2sphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2tphaseshift": {
"type": "range",
"name": "WS1_Electric_Phase_Whole_Degrees_Positive",
"description": "Degrees in whole units",
"range": [
0,
180
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Short_Percent_Range",
"description": "Range domain for setting a percentage in whole numbers",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 17,
"name": "Low Voltage Line Monitor and Relay"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor",
"description": "Low Voltage Motor",
"codedValues": [
{
"name": "Motor",
"code": 0
},
{
"name": "Single Phase Motor LV",
"code": 341
},
{
"name": "Three Phase Motor LV",
"code": 342
},
{
"name": "DC Motor LV",
"code": 343
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Type",
"description": "Motor Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Induction",
"code": 1
},
{
"name": "Synchronous",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Generation_ANSI_Group_Code",
"description": "ANSI Generation Group Code",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Group 2",
"code": 2
},
{
"name": "Group 3",
"code": 3
},
{
"name": "Group 4",
"code": 4
},
{
"name": "Group 5",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Motor_Assistance_Type",
"description": "Motor Starting Assistance Types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Auto Transformer",
"code": 1
},
{
"name": "Capacitor",
"code": 2
},
{
"name": "Inductor",
"code": 3
},
{
"name": "Inductor & Resistor",
"code": 4
},
{
"name": "Resistor",
"code": 5
},
{
"name": "Star-Delta",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 18,
"name": "Low Voltage Motor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection",
"description": "Low Voltage Network Protection",
"codedValues": [
{
"name": "Network Protector",
"code": 0
},
{
"name": "Network Protector LV",
"code": 361
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps",
"description": "List of valid interrupting amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "30 A",
"code": 30
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
},
{
"name": "1000 A",
"code": 1000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps",
"description": "List of valid continuous amps for a fuse",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "3 A",
"code": 3
},
{
"name": "7 A",
"code": 7
},
{
"name": "10 A",
"code": 10
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "25 A",
"code": 25
},
{
"name": "30 A",
"code": 30
},
{
"name": "40 A",
"code": 40
},
{
"name": "50 A",
"code": 50
},
{
"name": "100 A",
"code": 100
},
{
"name": "200 A",
"code": 200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 19,
"name": "Low Voltage Network Protection"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion",
"description": "Low Voltage Power Conversion",
"codedValues": [
{
"name": "Power Conversion",
"code": 0
},
{
"name": "Single Phase Inverter LV",
"code": 381
},
{
"name": "Single Phase Rectifier LV",
"code": 382
},
{
"name": "Three Phase Inverter LV",
"code": 383
},
{
"name": "Three Phase Rectifier LV",
"code": 384
},
{
"name": "Single Phase Bidirectional LV",
"code": 386
},
{
"name": "Three Phase Bidirectional LV",
"code": 387
},
{
"name": "Wave Trap LV",
"code": 390
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage",
"description": "DC Nominal Low Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "36 V",
"code": 36
},
{
"name": "48 V",
"code": 48
},
{
"name": "60 V",
"code": 60
},
{
"name": "68 V",
"code": 68
},
{
"name": "72 V",
"code": 72
},
{
"name": "110 V",
"code": 110
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "160 V",
"code": 160
},
{
"name": "380 V",
"code": 380
},
{
"name": "500 V",
"code": 500
},
{
"name": "575 V",
"code": 575
},
{
"name": "600 V",
"code": 600
},
{
"name": "750 V",
"code": 750
},
{
"name": "1000 V",
"code": 1000
},
{
"name": "1500 V",
"code": 1500
},
{
"name": "400 V",
"code": 400
},
{
"name": "690 V",
"code": 690
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 20,
"name": "Low Voltage Power Conversion"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting",
"description": "Low Voltage Power Factor Correcting",
"codedValues": [
{
"name": "Power Factor Correcting",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "Mobile Harmonic Filter LV",
"code": 401
},
{
"name": "Mobile Reactor LV",
"code": 402
},
{
"name": "Overhead Capacitor LV",
"code": 403
},
{
"name": "Overhead Harmonic Filter LV",
"code": 404
},
{
"name": "Overhead Reactor LV",
"code": 405
},
{
"name": "Pad Mounted Capacitor LV",
"code": 406
},
{
"name": "Pad Mounted Harmonic Filter LV",
"code": 407
},
{
"name": "Pad Mounted Reactor LV",
"code": 408
},
{
"name": "Station Capacitor LV",
"code": 409
},
{
"name": "Station Harmonic Filter LV",
"code": 410
},
{
"name": "Station Reactor LV",
"code": 411
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Electric_Configuration_Type",
"description": "How equiment is configuration, in Series or Shunt",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Shunt",
"code": 1
},
{
"name": "Series",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Device_Resistance_Range",
"description": "Range of valid resistance values",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_Capacitory_Type",
"description": "Type of Capacitor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "kVA-PF",
"code": 1
},
{
"name": "AMP-PF",
"code": 2
},
{
"name": "kW-kVAR",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"upperrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lowerrange": {
"type": "codedValue",
"name": "WS1_Electric_Temperature_F",
"description": "Temperature in Fahrenheit",
"codedValues": [
{
"name": "32 F",
"code": 0
},
{
"name": "167 F",
"code": 75
},
{
"name": "194 F",
"code": 90
},
{
"name": "302 F",
"code": 150
},
{
"name": "356 F",
"code": 180
},
{
"name": "410 F",
"code": 210
},
{
"name": "446 F",
"code": 230
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_PF_Control_Type",
"description": "Power Factor Control Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Current",
"code": 1
},
{
"name": "Manual",
"code": 2
},
{
"name": "Power Factor",
"code": 3
},
{
"name": "VAR",
"code": 4
},
{
"name": "Tempature",
"code": 5
},
{
"name": "Time",
"code": 6
},
{
"name": "Reactive Current",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_KVAR",
"description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "25 kvar",
"code": 25000
},
{
"name": "50 kvar",
"code": 50000
},
{
"name": "75 kvar",
"code": 75000
},
{
"name": "100 kvar",
"code": 100000
},
{
"name": "125 kvar",
"code": 125000
},
{
"name": "150 kvar",
"code": 150000
},
{
"name": "175 kvar",
"code": 175000
},
{
"name": "200 kvar",
"code": 200000
},
{
"name": "225 kvar",
"code": 225000
},
{
"name": "250 kvar",
"code": 250000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 21,
"name": "Low Voltage Power Factor Correcting"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service",
"description": "Low Voltage Service",
"codedValues": [
{
"name": "Service",
"code": 0
},
{
"name": "Single Phase Commercial LV",
"code": 421
},
{
"name": "Single Phase Residential LV",
"code": 422
},
{
"name": "Three Phase Commercial LV",
"code": 423
},
{
"name": "Three Phase Residential LV",
"code": 424
},
{
"name": "Unmetered Load LV",
"code": 425
},
{
"name": "DC Commercial LV",
"code": 426
},
{
"name": "Low Voltage Premise LV",
"code": 427
},
{
"name": "Car Charger LV",
"code": 428
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"ratedpower": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"iscritical": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"centertap": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": "_CENTERTAPLOADMIX",
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 22,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch",
"description": "Low Voltage Switch",
"codedValues": [
{
"name": "Switch",
"code": 0
},
{
"name": "AC Overhead",
"code": 1
},
{
"name": "AC Underground",
"code": 2
},
{
"name": "AC Station",
"code": 3
},
{
"name": "AC Overhead Bank",
"code": 4
},
{
"name": "AC Underground Bank",
"code": 5
},
{
"name": "AC Station Bank",
"code": 6
},
{
"name": "DC Overhead",
"code": 11
},
{
"name": "DC Underground",
"code": 12
},
{
"name": "DC Station",
"code": 13
},
{
"name": "DC Overhead Bank",
"code": 14
},
{
"name": "DC Underground Bank",
"code": 15
},
{
"name": "DC Station Bank",
"code": 16
},
{
"name": "AC Station Disconnect LV",
"code": 431
},
{
"name": "AC Station Load Break LV",
"code": 432
},
{
"name": "AC Station Load Break Disconnect LV",
"code": 433
},
{
"name": "AC Station Disconnect LV - Controller",
"code": 434
},
{
"name": "AC Station Load Break LV - Controller",
"code": 435
},
{
"name": "AC Station Load Break Disconnect LV - Controller",
"code": 436
},
{
"name": "Overhead AC Load Break LV",
"code": 441
},
{
"name": "Overhead AC Disconnect LV",
"code": 442
},
{
"name": "Overhead DC Load Break LV",
"code": 443
},
{
"name": "Overhead DC Disconnect LV",
"code": 444
},
{
"name": "Underground AC Load Break LV",
"code": 445
},
{
"name": "Underground AC Disconnect LV",
"code": 446
},
{
"name": "Underground DC Load Break LV",
"code": 447
},
{
"name": "Underground DC Disconnect LV",
"code": 448
},
{
"name": "Indoor AC Load Break LV",
"code": 449
},
{
"name": "Indoor AC Disconnect LV",
"code": 450
},
{
"name": "Indoor DC Load Break LV",
"code": 451
},
{
"name": "Indoor DC Disconnect LV",
"code": 452
},
{
"name": "Source Selectable Switch LV",
"code": 453
},
{
"name": "Overhead Jumper LV",
"code": 454
},
{
"name": "DC Station LV",
"code": 456
},
{
"name": "AC Station Bypass LV",
"code": 457
},
{
"name": "AC Recloser LV",
"code": 458
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {
"type": "codedValue",
"name": "WS1_Electric_Device_Switch_Manufacturer",
"description": "All Electric Device Switch Manufacturer",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ABB/Westinghouse",
"code": 1
},
{
"name": "G&W Electric",
"code": 16
},
{
"name": "General Electric",
"code": 17
},
{
"name": "Royal Switchgear Mfg Co Inc",
"code": 44
},
{
"name": "S&C",
"code": 45
},
{
"name": "McGraw Edison",
"code": 62
},
{
"name": "AB Chance",
"code": 71
},
{
"name": "ABB T&D",
"code": 72
},
{
"name": "Cooper",
"code": 73
},
{
"name": "Eisler Engineering",
"code": 74
},
{
"name": "Elastimold",
"code": 75
},
{
"name": "Hi-Tech Fuses",
"code": 76
},
{
"name": "Kearney",
"code": 77
},
{
"name": "RTE",
"code": 88
},
{
"name": "Southern State Equipment",
"code": 94
},
{
"name": "USCO Power Equipment",
"code": 105
},
{
"name": "Wagner",
"code": 108
},
{
"name": "Action Trans",
"code": 110
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tripmode": {
"type": "codedValue",
"name": "WS1_Electric_Trip_Type",
"description": "Valid types of tripping",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trip Only",
"code": 10
},
{
"name": "Trip and Lockout",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Switch_Breaking_Medium",
"description": "Switch Arc Breaking Medium",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air",
"code": 1
},
{
"name": "CO2",
"code": 2
},
{
"name": "Gas",
"code": 3
},
{
"name": "Hybrid",
"code": 4
},
{
"name": "Oil",
"code": 5
},
{
"name": "Vaccum",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"minimumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps",
"description": "Low Voltage Switch Interrupting Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "10 kA",
"code": 10000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps",
"description": "Low Voltage Switch Continuous Amps",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "15 A",
"code": 15
},
{
"name": "20 A",
"code": 20
},
{
"name": "30 A",
"code": 30
},
{
"name": "45 A",
"code": 45
},
{
"name": "50 A",
"code": 50
},
{
"name": "60 A",
"code": 60
},
{
"name": "100 A",
"code": 100
},
{
"name": "125 A",
"code": 125
},
{
"name": "200 A",
"code": 200
},
{
"name": "225 A",
"code": 225
},
{
"name": "300 A",
"code": 300
},
{
"name": "320 A",
"code": 320
},
{
"name": "800 A",
"code": 800
},
{
"name": "1200 A",
"code": 1200
},
{
"name": "2500 A",
"code": 2500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"fieldoperation": {"type": "inherited"},
"operatingmechanism": {"type": "inherited"},
"isriser": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 23,
"name": "Low Voltage Switch"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer",
"description": "Low Voltage Transformer",
"codedValues": [
{
"name": "Transformer",
"code": 0
},
{
"name": "Single Phase - LV->LV",
"code": 461
},
{
"name": "Three Phase - LV->LV",
"code": 462
},
{
"name": "Three Winding - LV->LV-LV",
"code": 463
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {"type": "inherited"},
"nominalvoltagelg": {"type": "inherited"},
"secondaryvoltagelinetoline": {"type": "inherited"},
"secondaryvoltagelinetoground": {"type": "inherited"},
"secondarygrounding": {"type": "inherited"},
"tertiaryvoltagelinetoline": {"type": "inherited"},
"tertiaryvoltagelinetoground": {"type": "inherited"},
"tertiarygrounding": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"peakload": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Watts",
"description": "",
"range": [
0,
100000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"offpeakload": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Watts",
"description": "",
"range": [
0,
20000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Transformer_VA",
"description": "Low Voltage Transformer kVA",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "0.5 kVA",
"code": 500
},
{
"name": "0.75 kVA",
"code": 750
},
{
"name": "1 kVA",
"code": 1000
},
{
"name": "1.5 kVA",
"code": 1500
},
{
"name": "2 kVA",
"code": 2000
},
{
"name": "3 kVA",
"code": 3000
},
{
"name": "5 kVA",
"code": 5000
},
{
"name": "7.5 kVA",
"code": 7500
},
{
"name": "10 kVA",
"code": 10000
},
{
"name": "15 kVA",
"code": 15000
},
{
"name": "25 kVA",
"code": 25000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Low_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Low Voltage",
"range": [
0,
100
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"powerfactor": {
"type": "range",
"name": "WS1_Electric_Power_Factor_Range",
"description": "Power Factor valid value range",
"range": [
0,
1
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"primarytotertiaryvectorygroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 24,
"name": "Low Voltage Transformer"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector",
"description": "Low Voltage Connectors",
"codedValues": [
{
"name": "Wire Connector",
"code": 0
},
{
"name": "Ring Terminal LV",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"planoperatingstatus": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"winteroperatingstatus": {"type": "inherited"},
"summeroperatingstatus": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": 0,
"normaloperatingstatus": 0,
"winteroperatingstatus": 0,
"summeroperatingstatus": 0,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 44,
"name": "Low Voltage Wire Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator",
"description": "Asset Types for Low Voltage Regulating Equipment",
"codedValues": [
{
"name": "Regulator",
"code": 0
},
{
"name": "AC Single Phase LV",
"code": 141
},
{
"name": "AC Three Phase LV",
"code": 142
},
{
"name": "DC Regulator LV",
"code": 143
},
{
"name": "Network Load Balancer LV",
"code": 144
},
{
"name": "Frequency Converter LV",
"code": 145
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {"type": "inherited"},
"manufacturer": {"type": "inherited"},
"grounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangermaximumchange": {
"type": "range",
"name": "WS1_Electric_Tap_Maximum_Change",
"description": "Valid Tap Maxium Change Range",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerlowerbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumboost": {
"type": "range",
"name": "WS1_Electric_Buck_Boost_Rate",
"description": "Valid Buck and Boost Rates",
"range": [
-10,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0xmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z1psimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x0r0impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"x1r1impedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"z0pmimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarygroundimpedance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"gridsidecouplinginductance": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"remotecontrollerindicator": {
"type": "codedValue",
"name": "WS1_Electric_Remoted_Controlled",
"description": "List of remote control types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "No",
"code": 2
},
{
"name": "All Phases",
"code": 4
},
{
"name": "Individual Phase",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"equipmentype": {
"type": "codedValue",
"name": "WS1_Electric_XFR_Type",
"description": "Transformer Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Dry",
"code": 1
},
{
"name": "Oil Filled",
"code": 2
},
{
"name": "Pumped Oil",
"code": 3
},
{
"name": "Air Cooled",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"tapsandpoles": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"directional": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"primarygroundimpedance2": {
"type": "range",
"name": "WS1_Electric_Impedance_Range",
"description": "Valid Impendance Range",
"range": [
0,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"reversetrip": {"type": "inherited"},
"timedelay": {"type": "inherited"},
"tripcount": {"type": "inherited"},
"tapmaxchange": {
"type": "range",
"name": "WS1_Electric_Taps_Range",
"description": "Valid Taps Range",
"range": [
0,
32
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"optype": {
"type": "codedValue",
"name": "WS1_Electric_Regulator_Operation_Type",
"description": "Regulator Operation Type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fixed Tap",
"code": 1
},
{
"name": "Regulator Terminal",
"code": 2
},
{
"name": "R-X settings",
"code": 3
},
{
"name": "Load center",
"code": 4
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ratedpower": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Regulator_VA",
"description": "Low Voltage Regulators Volt Amps",
"codedValues": [
{
"name": "600 VA",
"code": 600
},
{
"name": "1200 VA",
"code": 1200
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangepercent": {"type": "inherited"},
"noloadloss": {
"type": "range",
"name": "WS1_Electric_Medium_Voltage_Load_Loss",
"description": "Valid Load Loss Range for Medium Voltage",
"range": [
0,
1000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ctratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ptratio": {
"type": "codedValue",
"name": "WS1_Electric_Winding_Ratio_Long",
"description": "Transformer and Regulator winding ratios",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "50:5",
"code": 50
},
{
"name": "60:5",
"code": 60
},
{
"name": "75:5",
"code": 75
},
{
"name": "80:5",
"code": 80
},
{
"name": "100:5",
"code": 100
},
{
"name": "125:5",
"code": 125
},
{
"name": "150:5",
"code": 150
},
{
"name": "200:5",
"code": 200
},
{
"name": "250:5",
"code": 250
},
{
"name": "300:5",
"code": 300
},
{
"name": "400:5",
"code": 400
},
{
"name": "500:5",
"code": 500
},
{
"name": "600:5",
"code": 600
},
{
"name": "800:5",
"code": 800
},
{
"name": "1000:5",
"code": 1000
},
{
"name": "1200:5",
"code": 1200
},
{
"name": "1500:5",
"code": 1500
},
{
"name": "1600:5",
"code": 1600
},
{
"name": "2000:5",
"code": 2000
},
{
"name": "3000:5",
"code": 3000
},
{
"name": "4000:5",
"code": 4000
},
{
"name": "6000:5",
"code": 6000
},
{
"name": "8000:5",
"code": 8000
},
{
"name": "5:5",
"code": 5
},
{
"name": "10:5",
"code": 10
},
{
"name": "15:5",
"code": 15
},
{
"name": "20:5",
"code": 20
},
{
"name": "25:5",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumbuck": {
"type": "range",
"name": "WS1_Electric_Regulator_Maximum_Buck_Boost",
"description": "Minimum and Maximum Regulator Buck percent",
"range": [
0,
20
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"buckbandwidth": {
"type": "range",
"name": "WS1_Electric_Voltage_Bandwidth",
"description": "Voltage Bandwidth Percentage",
"range": [
-5000,
5000
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerupperbandwidth": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"loadtapchangerminimumchange": {
"type": "range",
"name": "WS1_Electric_Load_Tap_Bandwidth",
"description": "Valid Load Tap Bandwidth",
"range": [
0,
10
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"starthour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"stophour": {
"type": "range",
"name": "WS1_Electric_Hour",
"description": "Hour of Operation",
"range": [
1,
24
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"coolingtype": {
"type": "codedValue",
"name": "WS1_Electric_Transformer_Cooling",
"description": "Transformer cooling type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Air Natural (AN)",
"code": 1
},
{
"name": "Air Blast",
"code": 2
},
{
"name": "Oil Natural/Air Natural (ONAN)",
"code": 3
},
{
"name": "Oil Natural/Air Forced (ONAF)",
"code": 4
},
{
"name": "Oil Forced/Air Forced (OFAF)",
"code": 5
},
{
"name": "Oil Forced/Water Forced (OFWF)",
"code": 6
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"inparallel": {
"type": "codedValue",
"name": "WS1_Yes_No",
"description": "Valid Yes, No values",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Yes",
"code": 1
},
{
"name": "No",
"code": 2
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"primarytosecondaryvectorgroup": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"hasarrester": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 45,
"name": "Low Voltage Regulator"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding",
"description": "Asset Types for Transformer Windings",
"codedValues": [
{
"name": "Transformer Winding",
"code": 0
},
{
"name": "AC Transformer Winding LV",
"code": 874
},
{
"name": "DC Transformer Winding LV",
"code": 875
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISSUBNETWORKCONTROLLER": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"TIERNAME": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasessubstituted": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Substitution",
"description": "Phase Substitution Values for Low Voltage",
"codedValues": [
{
"name": "abc->000",
"code": 0
},
{
"name": "abc->00a",
"code": 4
},
{
"name": "abc->00b",
"code": 2
},
{
"name": "abc->00c",
"code": 1
},
{
"name": "abc->0a0",
"code": 32
},
{
"name": "abc->0aa",
"code": 36
},
{
"name": "abc->0ab",
"code": 34
},
{
"name": "abc->0ac",
"code": 33
},
{
"name": "abc->0b0",
"code": 16
},
{
"name": "abc->0ba",
"code": 20
},
{
"name": "abc->0bb",
"code": 18
},
{
"name": "abc->0bc",
"code": 17
},
{
"name": "abc->0c0",
"code": 8
},
{
"name": "abc->0ca",
"code": 12
},
{
"name": "abc->0cb",
"code": 10
},
{
"name": "abc->0cc",
"code": 9
},
{
"name": "abc->a00",
"code": 256
},
{
"name": "abc->a0a",
"code": 260
},
{
"name": "abc->a0b",
"code": 258
},
{
"name": "abc->a0c",
"code": 257
},
{
"name": "abc->aa0",
"code": 288
},
{
"name": "abc->aaa",
"code": 292
},
{
"name": "abc->aab",
"code": 290
},
{
"name": "abc->aac",
"code": 289
},
{
"name": "abc->ab0",
"code": 272
},
{
"name": "abc->aba",
"code": 276
},
{
"name": "abc->abb",
"code": 274
},
{
"name": "abc->abc",
"code": 273
},
{
"name": "abc->ac0",
"code": 264
},
{
"name": "abc->aca",
"code": 268
},
{
"name": "abc->acb",
"code": 266
},
{
"name": "abc->acc",
"code": 265
},
{
"name": "abc->b00",
"code": 128
},
{
"name": "abc->b0a",
"code": 132
},
{
"name": "abc->b0b",
"code": 130
},
{
"name": "abc->b0c",
"code": 129
},
{
"name": "abc->ba0",
"code": 160
},
{
"name": "abc->baa",
"code": 164
},
{
"name": "abc->bab",
"code": 162
},
{
"name": "abc->bac",
"code": 161
},
{
"name": "abc->bb0",
"code": 144
},
{
"name": "abc->bba",
"code": 148
},
{
"name": "abc->bbb",
"code": 146
},
{
"name": "abc->bbc",
"code": 145
},
{
"name": "abc->bc0",
"code": 136
},
{
"name": "abc->bca",
"code": 140
},
{
"name": "abc->bcb",
"code": 138
},
{
"name": "abc->bcc",
"code": 137
},
{
"name": "abc->c00",
"code": 64
},
{
"name": "abc->c0a",
"code": 68
},
{
"name": "abc->c0b",
"code": 66
},
{
"name": "abc->c0c",
"code": 65
},
{
"name": "abc->ca0",
"code": 96
},
{
"name": "abc->caa",
"code": 100
},
{
"name": "abc->cab",
"code": 98
},
{
"name": "abc->cac",
"code": 97
},
{
"name": "abc->cb0",
"code": 80
},
{
"name": "abc->cba",
"code": 84
},
{
"name": "abc->cbb",
"code": 82
},
{
"name": "abc->cbc",
"code": 81
},
{
"name": "abc->cc0",
"code": 72
},
{
"name": "abc->cca",
"code": 76
},
{
"name": "abc->ccb",
"code": 74
},
{
"name": "abc->ccc",
"code": 73
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"secondaryvoltagelinetoline": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondaryvoltagelinetoground": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"secondarygrounding": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Configuration",
"description": "List of valid ground types for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Grounded Wye",
"code": 1
},
{
"name": "Wye",
"code": 2
},
{
"name": "Delta",
"code": 3
},
{
"name": "Grounded Delta",
"code": 4
},
{
"name": "Direct Current",
"code": 5
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"symbolrotation": {"type": "inherited"},
"p2sphaseshift": {"type": "inherited"},
"p2tphaseshift": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISSUBNETWORKCONTROLLER": 0,
"ISCONNECTED": 2,
"SUBNETWORKCONTROLLERNAME": "Unknown",
"TIERNAME": 0,
"TIERRANK": 0,
"TERMINALCONFIGURATION": "Default",
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"planoperatingstatus": null,
"normaloperatingstatus": null,
"winteroperatingstatus": null,
"summeroperatingstatus": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasessubstituted": null,
"phasefrequency": null,
"numphasesconstructed": null,
"designtype": null,
"manufacturer": null,
"grounding": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"secondaryvoltagelinetoline": null,
"secondaryvoltagelinetoground": null,
"secondarygrounding": null,
"tertiaryvoltagelinetoline": null,
"tertiaryvoltagelinetoground": null,
"tertiarygrounding": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"compatibleunit": null,
"lifecyclestatus": 2,
"model": null,
"loadtapchangermaximumchange": null,
"loadtapchangerlowerbandwidth": null,
"maximumboost": null,
"z0psimpedance": null,
"z0xmimpedance": null,
"z1psimpedance": null,
"x0r0impedance": null,
"x1r1impedance": null,
"z0pmimpedance": null,
"primarygroundimpedance": null,
"gridsidecouplinginductance": null,
"remotecontrollerindicator": null,
"equipmentype": null,
"tripmode": null,
"tapsandpoles": null,
"directional": null,
"peakload": null,
"offpeakload": null,
"district": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"notes": null,
"symbolrotation": null,
"upperrange": null,
"lowerrange": null,
"primarygroundimpedance2": null,
"reversetrip": null,
"p2sphaseshift": null,
"p2tphaseshift": null,
"timedelay": null,
"tripcount": null,
"tapmaxchange": null,
"optype": null,
"maximumpower": null,
"minimumpower": null,
"ratedpower": null,
"loadtapchangepercent": null,
"noloadloss": null,
"secondarygroundimpedance": null,
"ctratio": null,
"ptratio": null,
"maximumbuck": null,
"secondarygroundimpedance2": null,
"buckbandwidth": null,
"loadtapchangerupperbandwidth": null,
"loadtapchangerminimumchange": null,
"starthour": null,
"stophour": null,
"powerfactor": null,
"coolingtype": null,
"inparallel": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"primarytosecondaryvectorgroup": null,
"primarytotertiaryvectorygroup": null,
"constructionstatus": 6,
"fieldoperation": null,
"operatingmechanism": null,
"primaryphaseshift": null,
"sectionid": null,
"TERMINALID": null,
"iscritical": null,
"isriser": null,
"hasarrester": null,
"isvalidloop": null,
"WithstandRating": null,
"centertap": null,
"sectionalizercabinetID": null,
"transformerlocationnumber": null,
"meterform": null,
"meterbase": null,
"meterclass": null,
"meterloadmis": null,
"metergisid": null,
"workorder": null,
"lightsphotoeye": null,
"lightswattage": null,
"birthyear": null,
"rel_guid": null,
"meterserialsurvalent": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 46,
"name": "Low Voltage Transformer Winding"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"hasM": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1757937024000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 430,
"name": "Secondary Conductor",
"type": "Feature Layer",
"description": " The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within any container feature that has rules allowing it.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
},
"copyrightText": "",
"parentLayer": {
"id": 400,
"name": "Electric"
},
"subLayers": [],
"minScale": 24000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "ASSETGROUP",
"field2": "ASSETTYPE",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "2,20",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "6,100",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,160",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,161",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,162",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,165",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,166",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,167",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "37,102",
"label": "Underground"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
252,
240,
255
],
"toColor": [
212,
252,
240,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
179,
252,
255
],
"toColor": [
252,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
183,
182,
255
],
"toColor": [
252,
183,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
201,
252,
255
],
"toColor": [
179,
201,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
238,
182,
255
],
"toColor": [
252,
238,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
184,
252,
189,
255
],
"toColor": [
184,
252,
189,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
240,
255
],
"toColor": [
252,
212,
240,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
234,
215,
255
],
"toColor": [
252,
234,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
228,
252,
255
],
"toColor": [
179,
228,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
221,
202,
252,
255
],
"toColor": [
221,
202,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
237,
252,
210,
255
],
"toColor": [
237,
252,
210,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
217,
255
],
"toColor": [
252,
184,
217,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
218,
252,
179,
255
],
"toColor": [
218,
252,
179,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 646553.9354125783,
"ymin": 639229.2276111543,
"xmax": 707061.4210246615,
"ymax": 695982.9940246567,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "assetgroup",
"typeIdField": "ASSETGROUP",
"subtypeFieldName": "ASSETGROUP",
"subtypeField": "ASSETGROUP",
"defaultSubtypeCode": 0,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "ASSETGROUP",
"type": "esriFieldTypeInteger",
"alias": "Asset Group",
"domain": null
},
{
"name": "ASSETTYPE",
"type": "esriFieldTypeSmallInteger",
"alias": "Asset Type",
"domain": null
},
{
"name": "lifecyclestatus",
"type": "esriFieldTypeSmallInteger",
"alias": "Lifecycle Status",
"domain": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status_Combined",
"description": "Bitwise combination of lifecycle states for subnetwork management",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Proposed and In Service",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "In Service and Planned Removal",
"code": 6
},
{
"name": "Maintenance",
"code": 7
},
{
"name": "Design",
"code": 11
},
{
"name": "Abandoned",
"code": 12
},
{
"name": "Removed",
"code": 13
},
{
"name": "Retired",
"code": 14
},
{
"name": "NA",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "ownedby",
"type": "esriFieldTypeSmallInteger",
"alias": "Owned By",
"domain": {
"type": "codedValue",
"name": "WS1_Asset_Owner",
"description": "The owner of the asset",
"codedValues": [
{
"name": "Our Agency",
"code": 1
},
{
"name": "Private",
"code": 2
},
{
"name": "Other",
"code": 100
},
{
"name": "Idaho Falls Power",
"code": 3
},
{
"name": "Rocky Mountain Power",
"code": 4
},
{
"name": "Century Link",
"code": 5
},
{
"name": "IF Parks & Recreation",
"code": 6
},
{
"name": "Idaho Department of Transportation",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "SHAPE.STLength()",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S183_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"WithstandRating": {"type": "inherited"},
"conductorsheaththickness": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Neutral",
"description": "Neutral",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Bare",
"code": 200
},
{
"name": "Overhead Shielded",
"code": 201
},
{
"name": "Underground Shielded",
"code": 202
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Neutral_Material",
"description": "List of valid neutral materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Steel",
"code": 506
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "All Aluminum Conductor",
"code": 516
},
{
"name": "All Aluminum Steel Reinforced",
"code": 517
},
{
"name": "Copper",
"code": 525
},
{
"name": "Hard Drawn Copper",
"code": 526
},
{
"name": "Soft Drawn Copper",
"code": 527
},
{
"name": "Stranded Copper",
"code": 528
},
{
"name": "Copper Weld",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 11,
"name": "Neutral Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Covered Ground",
"code": 221
},
{
"name": "Bare Ground",
"code": 222
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 12,
"name": "Ground Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor",
"description": "High Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead HV",
"code": 20
},
{
"name": "DC Overhead HV",
"code": 23
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {"type": "inherited"},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 2,
"name": "High Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor",
"description": "High VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground HV",
"code": 22
},
{
"name": "DC Underground HV",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 31,
"name": "High Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor",
"description": "High VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible HV",
"code": 21
},
{
"name": "DC Submersible HV",
"code": 24
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 32,
"name": "High Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar",
"description": "High Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Station Single Phase HV",
"code": 1
},
{
"name": "AC Station Three Phase HV",
"code": 2
},
{
"name": "DC Station HV",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 1,
"name": "High Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector",
"description": "High Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector HV",
"code": 40
},
{
"name": "DC Connector HV",
"code": 41
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 3,
"name": "High Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire",
"description": "High Voltage Static Wire",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 60
},
{
"name": "Single",
"code": 61
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 4,
"name": "High Voltage Static Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service",
"description": "High Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service HV",
"code": 260
},
{
"name": "AC Underground Service HV",
"code": 261
},
{
"name": "DC Overhead Service HV",
"code": 262
},
{
"name": "DC Underground Service HV",
"code": 263
},
{
"name": "AC Submersible Service HV",
"code": 264
},
{
"name": "DC Submersible Service HV",
"code": 265
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 15,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor",
"description": "Medium Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase MV",
"code": 160
},
{
"name": "Overhead Three Phase MV",
"code": 161
},
{
"name": "Overhead Two Phase MV",
"code": 162
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 9,
"name": "Medium Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor",
"description": "Medium VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Underground Single Phase MV",
"code": 165
},
{
"name": "Underground Three Phase MV",
"code": 166
},
{
"name": "Underground Two Phase MV",
"code": 167
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 34,
"name": "Medium Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor",
"description": "Medium VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Submersible Single Phase MV",
"code": 163
},
{
"name": "Submersible Three Phase MV",
"code": 164
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 35,
"name": "Medium Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar",
"description": "Medium Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cabinet Single Phase MV",
"code": 140
},
{
"name": "Cabinet Three Phase MV",
"code": 141
},
{
"name": "Station Single Phase MV",
"code": 142
},
{
"name": "Station Three Phase MV",
"code": 143
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 8,
"name": "Medium Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector",
"description": "Medium Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase MV",
"code": 180
},
{
"name": "Three Phase MV",
"code": 181
},
{
"name": "Two Phase MV",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 10,
"name": "Medium Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service",
"description": "Medium Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase Service MV",
"code": 170
},
{
"name": "Overhead Three Phase Service MV",
"code": 171
},
{
"name": "Overhead Two Phase Service MV",
"code": 172
},
{
"name": "Submersible Single Phase Service MV",
"code": 173
},
{
"name": "Submersible Three Phase Service MV",
"code": 174
},
{
"name": "Underground Single Phase Service MV",
"code": 175
},
{
"name": "Underground Three Phase Service MV",
"code": 176
},
{
"name": "Underground Two Phase Service MV",
"code": 177
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 14,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar",
"description": "Low Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Cabinet LV",
"code": 80
},
{
"name": "AC Station LV",
"code": 81
},
{
"name": "DC Cabinet LV",
"code": 82
},
{
"name": "DC Station LV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 5,
"name": "Low Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector",
"description": "Low Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector LV",
"code": 120
},
{
"name": "DC Connector LV",
"code": 121
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 7,
"name": "Low Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service",
"description": "List of asset types for Low Voltage Services",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service LV",
"code": 110
},
{
"name": "AC Underground Service LV",
"code": 112
},
{
"name": "DC Overhead Service LV",
"code": 113
},
{
"name": "DC Underground Service LV",
"code": 115
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 13,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor",
"description": "Low Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead LV",
"code": 100
},
{
"name": "DC Overhead LV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 6,
"name": "Low Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor",
"description": "Low VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground LV",
"code": 102
},
{
"name": "DC Underground LV",
"code": 105
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 37,
"name": "Low Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor",
"description": "Low VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible LV",
"code": 101
},
{
"name": "DC Submersible LV",
"code": 104
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 38,
"name": "Low Voltage Submersible Conductor"
}
],
"subtypes": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"WithstandRating": {"type": "inherited"},
"conductorsheaththickness": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Neutral",
"description": "Neutral",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Bare",
"code": 200
},
{
"name": "Overhead Shielded",
"code": 201
},
{
"name": "Underground Shielded",
"code": 202
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Neutral_Material",
"description": "List of valid neutral materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Steel",
"code": 506
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "All Aluminum Conductor",
"code": 516
},
{
"name": "All Aluminum Steel Reinforced",
"code": 517
},
{
"name": "Copper",
"code": 525
},
{
"name": "Hard Drawn Copper",
"code": 526
},
{
"name": "Soft Drawn Copper",
"code": 527
},
{
"name": "Stranded Copper",
"code": 528
},
{
"name": "Copper Weld",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 11,
"name": "Neutral Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Covered Ground",
"code": 221
},
{
"name": "Bare Ground",
"code": 222
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 12,
"name": "Ground Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor",
"description": "High Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead HV",
"code": 20
},
{
"name": "DC Overhead HV",
"code": 23
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {"type": "inherited"},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 2,
"name": "High Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor",
"description": "High VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground HV",
"code": 22
},
{
"name": "DC Underground HV",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": null,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 31,
"name": "High Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor",
"description": "High VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible HV",
"code": 21
},
{
"name": "DC Submersible HV",
"code": 24
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 32,
"name": "High Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar",
"description": "High Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Station Single Phase HV",
"code": 1
},
{
"name": "AC Station Three Phase HV",
"code": 2
},
{
"name": "DC Station HV",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 1,
"name": "High Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector",
"description": "High Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector HV",
"code": 40
},
{
"name": "DC Connector HV",
"code": 41
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 3,
"name": "High Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire",
"description": "High Voltage Static Wire",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 60
},
{
"name": "Single",
"code": 61
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 4,
"name": "High Voltage Static Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service",
"description": "High Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service HV",
"code": 260
},
{
"name": "AC Underground Service HV",
"code": 261
},
{
"name": "DC Overhead Service HV",
"code": 262
},
{
"name": "DC Underground Service HV",
"code": 263
},
{
"name": "AC Submersible Service HV",
"code": 264
},
{
"name": "DC Submersible Service HV",
"code": 265
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 15,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor",
"description": "Medium Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase MV",
"code": 160
},
{
"name": "Overhead Three Phase MV",
"code": 161
},
{
"name": "Overhead Two Phase MV",
"code": 162
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 9,
"name": "Medium Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor",
"description": "Medium VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Underground Single Phase MV",
"code": 165
},
{
"name": "Underground Three Phase MV",
"code": 166
},
{
"name": "Underground Two Phase MV",
"code": 167
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 34,
"name": "Medium Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor",
"description": "Medium VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Submersible Single Phase MV",
"code": 163
},
{
"name": "Submersible Three Phase MV",
"code": 164
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 35,
"name": "Medium Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar",
"description": "Medium Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cabinet Single Phase MV",
"code": 140
},
{
"name": "Cabinet Three Phase MV",
"code": 141
},
{
"name": "Station Single Phase MV",
"code": 142
},
{
"name": "Station Three Phase MV",
"code": 143
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 8,
"name": "Medium Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector",
"description": "Medium Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase MV",
"code": 180
},
{
"name": "Three Phase MV",
"code": 181
},
{
"name": "Two Phase MV",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 10,
"name": "Medium Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service",
"description": "Medium Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase Service MV",
"code": 170
},
{
"name": "Overhead Three Phase Service MV",
"code": 171
},
{
"name": "Overhead Two Phase Service MV",
"code": 172
},
{
"name": "Submersible Single Phase Service MV",
"code": 173
},
{
"name": "Submersible Three Phase Service MV",
"code": 174
},
{
"name": "Underground Single Phase Service MV",
"code": 175
},
{
"name": "Underground Three Phase Service MV",
"code": 176
},
{
"name": "Underground Two Phase Service MV",
"code": 177
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 14,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar",
"description": "Low Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Cabinet LV",
"code": 80
},
{
"name": "AC Station LV",
"code": 81
},
{
"name": "DC Cabinet LV",
"code": 82
},
{
"name": "DC Station LV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 5,
"name": "Low Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector",
"description": "Low Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector LV",
"code": 120
},
{
"name": "DC Connector LV",
"code": 121
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 7,
"name": "Low Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service",
"description": "List of asset types for Low Voltage Services",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service LV",
"code": 110
},
{
"name": "AC Underground Service LV",
"code": 112
},
{
"name": "DC Overhead Service LV",
"code": 113
},
{
"name": "DC Underground Service LV",
"code": 115
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 13,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor",
"description": "Low Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead LV",
"code": 100
},
{
"name": "DC Overhead LV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 6,
"name": "Low Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor",
"description": "Low VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground LV",
"code": 102
},
{
"name": "DC Underground LV",
"code": 105
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 37,
"name": "Low Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor",
"description": "Low VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible LV",
"code": 101
},
{
"name": "DC Submersible LV",
"code": 104
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 38,
"name": "Low Voltage Submersible Conductor"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"hasM": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"effectiveMinScale": 12000,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1757937049000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 440,
"name": "Primary Conductor",
"type": "Feature Layer",
"description": " The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within any container feature that has rules allowing it.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
},
"copyrightText": "",
"parentLayer": {
"id": 400,
"name": "Electric"
},
"subLayers": [],
"minScale": 24000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "ASSETGROUP",
"field2": "ASSETTYPE",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "2,20",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "6,100",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,160",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,161",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "9,162",
"label": "Overhead"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,165",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,166",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "34,167",
"label": "Underground"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 3
},
"value": "37,102",
"label": "Underground"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
252,
240,
255
],
"toColor": [
212,
252,
240,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
179,
252,
255
],
"toColor": [
252,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
183,
182,
255
],
"toColor": [
252,
183,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
201,
252,
255
],
"toColor": [
179,
201,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
238,
182,
255
],
"toColor": [
252,
238,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
184,
252,
189,
255
],
"toColor": [
184,
252,
189,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
240,
255
],
"toColor": [
252,
212,
240,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
234,
215,
255
],
"toColor": [
252,
234,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
228,
252,
255
],
"toColor": [
179,
228,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
221,
202,
252,
255
],
"toColor": [
221,
202,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
237,
252,
210,
255
],
"toColor": [
237,
252,
210,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
217,
255
],
"toColor": [
252,
184,
217,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
218,
252,
179,
255
],
"toColor": [
218,
252,
179,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 646553.9354125783,
"ymin": 639229.2276111543,
"xmax": 707061.4210246615,
"ymax": 695982.9940246567,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "assetgroup",
"typeIdField": "ASSETGROUP",
"subtypeFieldName": "ASSETGROUP",
"subtypeField": "ASSETGROUP",
"defaultSubtypeCode": 0,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "ASSETGROUP",
"type": "esriFieldTypeInteger",
"alias": "Asset Group",
"domain": null
},
{
"name": "ASSETTYPE",
"type": "esriFieldTypeSmallInteger",
"alias": "Asset Type",
"domain": null
},
{
"name": "lifecyclestatus",
"type": "esriFieldTypeSmallInteger",
"alias": "Lifecycle Status",
"domain": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status_Combined",
"description": "Bitwise combination of lifecycle states for subnetwork management",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Proposed and In Service",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "In Service and Planned Removal",
"code": 6
},
{
"name": "Maintenance",
"code": 7
},
{
"name": "Design",
"code": 11
},
{
"name": "Abandoned",
"code": 12
},
{
"name": "Removed",
"code": 13
},
{
"name": "Retired",
"code": 14
},
{
"name": "NA",
"code": 15
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "SHAPE.STLength()",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S183_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"WithstandRating": {"type": "inherited"},
"conductorsheaththickness": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Neutral",
"description": "Neutral",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Bare",
"code": 200
},
{
"name": "Overhead Shielded",
"code": 201
},
{
"name": "Underground Shielded",
"code": 202
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Neutral_Material",
"description": "List of valid neutral materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Steel",
"code": 506
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "All Aluminum Conductor",
"code": 516
},
{
"name": "All Aluminum Steel Reinforced",
"code": 517
},
{
"name": "Copper",
"code": 525
},
{
"name": "Hard Drawn Copper",
"code": 526
},
{
"name": "Soft Drawn Copper",
"code": 527
},
{
"name": "Stranded Copper",
"code": 528
},
{
"name": "Copper Weld",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 11,
"name": "Neutral Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Covered Ground",
"code": 221
},
{
"name": "Bare Ground",
"code": 222
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 12,
"name": "Ground Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor",
"description": "High Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead HV",
"code": 20
},
{
"name": "DC Overhead HV",
"code": 23
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {"type": "inherited"},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 2,
"name": "High Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor",
"description": "High VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground HV",
"code": 22
},
{
"name": "DC Underground HV",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 31,
"name": "High Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor",
"description": "High VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible HV",
"code": 21
},
{
"name": "DC Submersible HV",
"code": 24
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 32,
"name": "High Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar",
"description": "High Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Station Single Phase HV",
"code": 1
},
{
"name": "AC Station Three Phase HV",
"code": 2
},
{
"name": "DC Station HV",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 1,
"name": "High Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector",
"description": "High Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector HV",
"code": 40
},
{
"name": "DC Connector HV",
"code": 41
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 3,
"name": "High Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire",
"description": "High Voltage Static Wire",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 60
},
{
"name": "Single",
"code": 61
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 4,
"name": "High Voltage Static Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service",
"description": "High Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service HV",
"code": 260
},
{
"name": "AC Underground Service HV",
"code": 261
},
{
"name": "DC Overhead Service HV",
"code": 262
},
{
"name": "DC Underground Service HV",
"code": 263
},
{
"name": "AC Submersible Service HV",
"code": 264
},
{
"name": "DC Submersible Service HV",
"code": 265
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 15,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor",
"description": "Medium Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase MV",
"code": 160
},
{
"name": "Overhead Three Phase MV",
"code": 161
},
{
"name": "Overhead Two Phase MV",
"code": 162
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 9,
"name": "Medium Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor",
"description": "Medium VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Underground Single Phase MV",
"code": 165
},
{
"name": "Underground Three Phase MV",
"code": 166
},
{
"name": "Underground Two Phase MV",
"code": 167
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 34,
"name": "Medium Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor",
"description": "Medium VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Submersible Single Phase MV",
"code": 163
},
{
"name": "Submersible Three Phase MV",
"code": 164
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 35,
"name": "Medium Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar",
"description": "Medium Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cabinet Single Phase MV",
"code": 140
},
{
"name": "Cabinet Three Phase MV",
"code": 141
},
{
"name": "Station Single Phase MV",
"code": 142
},
{
"name": "Station Three Phase MV",
"code": 143
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 8,
"name": "Medium Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector",
"description": "Medium Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase MV",
"code": 180
},
{
"name": "Three Phase MV",
"code": 181
},
{
"name": "Two Phase MV",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 10,
"name": "Medium Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service",
"description": "Medium Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase Service MV",
"code": 170
},
{
"name": "Overhead Three Phase Service MV",
"code": 171
},
{
"name": "Overhead Two Phase Service MV",
"code": 172
},
{
"name": "Submersible Single Phase Service MV",
"code": 173
},
{
"name": "Submersible Three Phase Service MV",
"code": 174
},
{
"name": "Underground Single Phase Service MV",
"code": 175
},
{
"name": "Underground Three Phase Service MV",
"code": 176
},
{
"name": "Underground Two Phase Service MV",
"code": 177
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 14,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar",
"description": "Low Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Cabinet LV",
"code": 80
},
{
"name": "AC Station LV",
"code": 81
},
{
"name": "DC Cabinet LV",
"code": 82
},
{
"name": "DC Station LV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 5,
"name": "Low Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector",
"description": "Low Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector LV",
"code": 120
},
{
"name": "DC Connector LV",
"code": 121
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 7,
"name": "Low Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service",
"description": "List of asset types for Low Voltage Services",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service LV",
"code": 110
},
{
"name": "AC Underground Service LV",
"code": 112
},
{
"name": "DC Overhead Service LV",
"code": 113
},
{
"name": "DC Underground Service LV",
"code": 115
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 13,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor",
"description": "Low Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead LV",
"code": 100
},
{
"name": "DC Overhead LV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 6,
"name": "Low Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor",
"description": "Low VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground LV",
"code": 102
},
{
"name": "DC Underground LV",
"code": 105
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 37,
"name": "Low Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor",
"description": "Low VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible LV",
"code": 101
},
{
"name": "DC Submersible LV",
"code": 104
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 38,
"name": "Low Voltage Submersible Conductor"
}
],
"subtypes": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"WithstandRating": {"type": "inherited"},
"conductorsheaththickness": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Neutral",
"description": "Neutral",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Bare",
"code": 200
},
{
"name": "Overhead Shielded",
"code": 201
},
{
"name": "Underground Shielded",
"code": 202
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {"type": "inherited"},
"phasechange": {"type": "inherited"},
"phasesplan": {"type": "inherited"},
"phasesenergized": {"type": "inherited"},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Neutral_Material",
"description": "List of valid neutral materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Steel",
"code": 506
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "All Aluminum Conductor",
"code": 516
},
{
"name": "All Aluminum Steel Reinforced",
"code": 517
},
{
"name": "Copper",
"code": 525
},
{
"name": "Hard Drawn Copper",
"code": 526
},
{
"name": "Soft Drawn Copper",
"code": 527
},
{
"name": "Stranded Copper",
"code": 528
},
{
"name": "Copper Weld",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 11,
"name": "Neutral Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Ground",
"description": "Ground",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Covered Ground",
"code": 221
},
{
"name": "Bare Ground",
"code": 222
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Ground_Material",
"description": "Grounding material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Aluminum",
"code": 515
},
{
"name": "Copper",
"code": 525
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 12,
"name": "Ground Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor",
"description": "High Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead HV",
"code": 20
},
{
"name": "DC Overhead HV",
"code": 23
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {"type": "inherited"},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 2,
"name": "High Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor",
"description": "High VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground HV",
"code": 22
},
{
"name": "DC Underground HV",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of High Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "121 kV",
"code": 121000
},
{
"name": "124 kV",
"code": 124000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "172 kV",
"code": 172000
},
{
"name": "245 kV",
"code": 245000
},
{
"name": "420 kV",
"code": 420000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": null,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 31,
"name": "High Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor",
"description": "High VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible HV",
"code": 21
},
{
"name": "DC Submersible HV",
"code": 24
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 32,
"name": "High Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar",
"description": "High Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Station Single Phase HV",
"code": 1
},
{
"name": "AC Station Three Phase HV",
"code": 2
},
{
"name": "DC Station HV",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 1,
"name": "High Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector",
"description": "High Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector HV",
"code": 40
},
{
"name": "DC Connector HV",
"code": 41
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phases_Constructed",
"description": "High Voltage number of Phase Constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
},
{
"name": "Six Phase",
"code": 6
},
{
"name": "Twelve Phase",
"code": 12
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 3,
"name": "High Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire",
"description": "High Voltage Static Wire",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 60
},
{
"name": "Single",
"code": 61
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Phase_Not_Applicable",
"description": "Domain for Phase attributes on Neutral and Ground",
"codedValues": [
{
"name": "N/A",
"code": 0
},
{
"name": "N/A, Traceable",
"code": 8
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 4,
"name": "High Voltage Static Wire"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service",
"description": "High Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service HV",
"code": 260
},
{
"name": "AC Underground Service HV",
"code": 261
},
{
"name": "DC Overhead Service HV",
"code": 262
},
{
"name": "DC Underground Service HV",
"code": 263
},
{
"name": "AC Submersible Service HV",
"code": 264
},
{
"name": "DC Submersible Service HV",
"code": 265
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the transmission system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "III",
"code": 1
},
{
"name": "II",
"code": 2
},
{
"name": "II,III",
"code": 3
},
{
"name": "I",
"code": 4
},
{
"name": "I,III",
"code": 5
},
{
"name": "I,II",
"code": 6
},
{
"name": "I,II,III",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 kV",
"code": 120000
},
{
"name": "145 kV",
"code": 145000
},
{
"name": "170 kV",
"code": 170000
},
{
"name": "240 kV",
"code": 240000
},
{
"name": "300 kV",
"code": 300000
},
{
"name": "362 kV",
"code": 362000
},
{
"name": "420 kV",
"code": 420000
},
{
"name": "550 kV",
"code": 550000
},
{
"name": "800 kV",
"code": 800000
},
{
"name": "1100 kV",
"code": 1100000
},
{
"name": "1200 kV",
"code": 1200000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for high voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "115 kV",
"code": 115000
},
{
"name": "138 kV",
"code": 138000
},
{
"name": "161 kV",
"code": 161000
},
{
"name": "230 kV",
"code": 230000
},
{
"name": "345 kV",
"code": 345000
},
{
"name": "500 kV",
"code": 500000
},
{
"name": "765 kV",
"code": 765000
},
{
"name": "18 kV",
"code": 18000
},
{
"name": "50 kV",
"code": 50000
},
{
"name": "60 kV",
"code": 60000
},
{
"name": "70 kV",
"code": 70000
},
{
"name": "75 kV",
"code": 75000
},
{
"name": "80 kV",
"code": 80000
},
{
"name": "100 kV",
"code": 100000
},
{
"name": "150 kV",
"code": 150000
},
{
"name": "180 kV",
"code": 180000
},
{
"name": "200 kV",
"code": 200000
},
{
"name": "250 kV",
"code": 250000
},
{
"name": "266 kV",
"code": 266000
},
{
"name": "277 kV",
"code": 277000
},
{
"name": "285 kV",
"code": 285000
},
{
"name": "320 kV",
"code": 320000
},
{
"name": "350 kV",
"code": 350000
},
{
"name": "400 kV",
"code": 400000
},
{
"name": "440 kV",
"code": 440000
},
{
"name": "515 kV",
"code": 515000
},
{
"name": "525 kV",
"code": 525000
},
{
"name": "533 kV",
"code": 533000
},
{
"name": "600 kV",
"code": 600000
},
{
"name": "1 MV",
"code": 1000000
},
{
"name": "1.1 MV",
"code": 1100000
},
{
"name": "1.2 MV",
"code": 1200000
},
{
"name": "1.4 MV",
"code": 1400000
},
{
"name": "1.5 MV",
"code": 1500000
},
{
"name": "1.8 MV",
"code": 1800000
},
{
"name": "2.5 MV",
"code": 2500000
},
{
"name": "3 MV",
"code": 3000000
},
{
"name": "4 MV",
"code": 4000000
},
{
"name": "5 MV",
"code": 5000000
},
{
"name": "6 MV",
"code": 6000000
},
{
"name": "6.4 MV",
"code": 6400000
},
{
"name": "7.2 MV",
"code": 7200000
},
{
"name": "8 MV",
"code": 8000000
},
{
"name": "10 MV",
"code": 10000000
},
{
"name": "12 MV",
"code": 12000000
},
{
"name": "46 kV",
"code": 46000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_High_Voltage_Conductor_Material",
"description": "List of valid High Voltage Conductor Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
},
{
"name": "1272 ACSR Bittern",
"code": 507
},
{
"name": "336 ACSR Merlin",
"code": 514
},
{
"name": "795 AAC Arbutus",
"code": 526
},
{
"name": "795 ACSR Drake",
"code": 527
},
{
"name": "927 ACAR",
"code": 529
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 15,
"name": "High Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor",
"description": "Medium Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase MV",
"code": 160
},
{
"name": "Overhead Three Phase MV",
"code": 161
},
{
"name": "Overhead Two Phase MV",
"code": 162
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 9,
"name": "Medium Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor",
"description": "Medium VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Underground Single Phase MV",
"code": 165
},
{
"name": "Underground Three Phase MV",
"code": 166
},
{
"name": "Underground Two Phase MV",
"code": 167
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"conductorspacing": {"type": "inherited"},
"phaseorder": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 34,
"name": "Medium Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor",
"description": "Medium VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Submersible Single Phase MV",
"code": 163
},
{
"name": "Submersible Three Phase MV",
"code": 164
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Conductor_Material",
"description": "List of valid medium voltage conductor materials for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "#1 ACSR",
"code": 1
},
{
"name": "#1 AL",
"code": 2
},
{
"name": "#1 B.STRD",
"code": 3
},
{
"name": "#1 CU",
"code": 4
},
{
"name": "#1 WP",
"code": 5
},
{
"name": "#2 PID AL",
"code": 6
},
{
"name": "#2 3/4 AWAC",
"code": 7
},
{
"name": "#2 4/3 AWAC",
"code": 8
},
{
"name": "#2 5/2 AWAC",
"code": 9
},
{
"name": "#2 5005",
"code": 10
},
{
"name": "#2 AAAC",
"code": 11
},
{
"name": "#2 AAC",
"code": 12
},
{
"name": "#2 AACTW",
"code": 13
},
{
"name": "#2 ACAR",
"code": 14
},
{
"name": "#2 ACSR",
"code": 15
},
{
"name": "#2 ACSR/SD",
"code": 17
},
{
"name": "#2 ACSRTW",
"code": 18
},
{
"name": "#2 AER.CAB",
"code": 19
},
{
"name": "#2 AL",
"code": 20
},
{
"name": "#2 AWA",
"code": 21
},
{
"name": "#2 AWAC",
"code": 22
},
{
"name": "#2 B.SOL",
"code": 23
},
{
"name": "#2 B.STRD",
"code": 24
},
{
"name": "#2 CU",
"code": 25
},
{
"name": "#2 CU PILC",
"code": 26
},
{
"name": "#2 HD",
"code": 27
},
{
"name": "#2 PECN",
"code": 28
},
{
"name": "#2 PECN AL",
"code": 29
},
{
"name": "#2 PECN CU",
"code": 30
},
{
"name": "#2 PECN-PEJ AL",
"code": 31
},
{
"name": "#2 PECN-PEJ PID",
"code": 32
},
{
"name": "#2 PECN-PEJ PID AL",
"code": 33
},
{
"name": "#2 PECN-PID AL",
"code": 34
},
{
"name": "#2 PID CU",
"code": 36
},
{
"name": "#2 PID-PEJ AL",
"code": 37
},
{
"name": "#2 PILC",
"code": 38
},
{
"name": "#2 PILC NJ CU",
"code": 39
},
{
"name": "#2 PILC-NJ",
"code": 40
},
{
"name": "#2 PILC-PEJ",
"code": 41
},
{
"name": "#2 PILC-PEJ CU",
"code": 42
},
{
"name": "#2 SOL",
"code": 43
},
{
"name": "#2 SOL PECN-PEJ AL",
"code": 44
},
{
"name": "#2 SOL TRXLPECN-PEJ AL PID",
"code": 45
},
{
"name": "#2 SOL XLPECN-PEJ",
"code": 46
},
{
"name": "#2 THW",
"code": 47
},
{
"name": "#2 TREE",
"code": 48
},
{
"name": "#2 TRXLPECN-PEJ AL PID",
"code": 49
},
{
"name": "#2 WP",
"code": 50
},
{
"name": "#2 WPAL",
"code": 51
},
{
"name": "#2 WPCU",
"code": 52
},
{
"name": "#2 XLPECN AL",
"code": 53
},
{
"name": "#2 XLPECN-PEJ",
"code": 54
},
{
"name": "#2 XLPECN-PEJ AL",
"code": 55
},
{
"name": "#2 XLPE-PEJ AL",
"code": 56
},
{
"name": "#2/7 TREE",
"code": 57
},
{
"name": "#2SOL TRXLPECN-PEJ AL PID",
"code": 58
},
{
"name": "#4 5005",
"code": 59
},
{
"name": "#4 ACSR",
"code": 60
},
{
"name": "#4 ACSRTW",
"code": 61
},
{
"name": "#4 AL",
"code": 62
},
{
"name": "#4 B.SOL",
"code": 63
},
{
"name": "#4 B.STRD",
"code": 64
},
{
"name": "#4 CU",
"code": 65
},
{
"name": "#4 GAL",
"code": 66
},
{
"name": "#4 HD",
"code": 67
},
{
"name": "#4 LEAD",
"code": 68
},
{
"name": "#4 NEOPRENE",
"code": 69
},
{
"name": "#4 PAA",
"code": 70
},
{
"name": "#4 PECN",
"code": 71
},
{
"name": "#4 PECN CU",
"code": 72
},
{
"name": "#4 PELPE CU",
"code": 73
},
{
"name": "#4 PID CU",
"code": 74
},
{
"name": "#4 PILC",
"code": 75
},
{
"name": "#4 PILC-NJ",
"code": 76
},
{
"name": "#4 PILC-PEJ CU",
"code": 77
},
{
"name": "#4 THW",
"code": 78
},
{
"name": "#4 TREE",
"code": 79
},
{
"name": "#4 WP",
"code": 80
},
{
"name": "#4 WPAL",
"code": 81
},
{
"name": "#4 WPCU",
"code": 82
},
{
"name": "#4A CUWELD",
"code": 83
},
{
"name": "#4D CUWELD",
"code": 84
},
{
"name": "#4N CUWELD",
"code": 85
},
{
"name": "#6 AL",
"code": 86
},
{
"name": "#6 B.SOL",
"code": 87
},
{
"name": "#6 B.STRD",
"code": 88
},
{
"name": "#6 CU",
"code": 89
},
{
"name": "#6 CUWELD",
"code": 90
},
{
"name": "#6 CW",
"code": 91
},
{
"name": "#6 GAL",
"code": 92
},
{
"name": "#6 HD",
"code": 93
},
{
"name": "#6 LEAD",
"code": 94
},
{
"name": "#6 PILC",
"code": 95
},
{
"name": "#6 PILC-PEJ CU",
"code": 96
},
{
"name": "#6 SOLID",
"code": 97
},
{
"name": "#6 THW",
"code": 98
},
{
"name": "#6 TREE",
"code": 99
},
{
"name": "#6 WP",
"code": 100
},
{
"name": "#6 WPAL",
"code": 101
},
{
"name": "#6 WPCU",
"code": 102
},
{
"name": "#6A CUWELD",
"code": 103
},
{
"name": "#8 AL",
"code": 104
},
{
"name": "#8 B.STRD",
"code": 105
},
{
"name": "#8 CU",
"code": 106
},
{
"name": "#8 CUWELD",
"code": 107
},
{
"name": "#8 HD",
"code": 108
},
{
"name": "#8 SOL",
"code": 109
},
{
"name": "#8 WP",
"code": 110
},
{
"name": "#8 WPCU",
"code": 111
},
{
"name": "#8A CUWELD",
"code": 112
},
{
"name": "1 ACSR",
"code": 113
},
{
"name": "1 ACSRTW",
"code": 114
},
{
"name": "1/0 15kV SpacerCable",
"code": 115
},
{
"name": "1/0 4/3 AWAC",
"code": 116
},
{
"name": "1/0 5005",
"code": 117
},
{
"name": "1/0 AAAC",
"code": 118
},
{
"name": "1/0 AAC",
"code": 119
},
{
"name": "1/0 ACAR",
"code": 120
},
{
"name": "1/0 ACSR",
"code": 121
},
{
"name": "1/0 ACSRTW",
"code": 122
},
{
"name": "1/0 AER.CAB",
"code": 123
},
{
"name": "1/0 AL",
"code": 124
},
{
"name": "1/0 ALUMOWELD",
"code": 125
},
{
"name": "1/0 AWA",
"code": 126
},
{
"name": "1/0 B.STRD",
"code": 127
},
{
"name": "1/0 CU",
"code": 128
},
{
"name": "1/0 LEAD",
"code": 129
},
{
"name": "1/0 OTH",
"code": 130
},
{
"name": "1/0 PAA",
"code": 131
},
{
"name": "1/0 PILC",
"code": 132
},
{
"name": "1/0 PILC-NJ",
"code": 133
},
{
"name": "1/0 STEEL",
"code": 134
},
{
"name": "1/0 THW",
"code": 135
},
{
"name": "1/0 TREE",
"code": 136
},
{
"name": "1/0 WP",
"code": 137
},
{
"name": "1/0 WPAL",
"code": 138
},
{
"name": "1/0 WPCU",
"code": 139
},
{
"name": "1000 PECN AL",
"code": 140
},
{
"name": "1000 PECN-PEJ AL",
"code": 141
},
{
"name": "1000 PILC-PEJ CU",
"code": 142
},
{
"name": "1000 TRXLPECN-PEJ CU",
"code": 143
},
{
"name": "1000 XLPE AL",
"code": 144
},
{
"name": "1000 XLPECN AL",
"code": 145
},
{
"name": "1000 XLPECN-PEJ",
"code": 146
},
{
"name": "1000 XLPECN-PEJ AL",
"code": 147
},
{
"name": "1000 XLPE-PEJ AL",
"code": 148
},
{
"name": "1033 ACSR",
"code": 149
},
{
"name": "1033 AL",
"code": 150
},
{
"name": "1250 RUBBER",
"code": 151
},
{
"name": "2/0 AAAC",
"code": 152
},
{
"name": "2/0 ACSR",
"code": 153
},
{
"name": "2/0 ACSRTW",
"code": 154
},
{
"name": "2/0 AL",
"code": 155
},
{
"name": "2/0 B.STRD",
"code": 156
},
{
"name": "2/0 CU",
"code": 157
},
{
"name": "2/0 PECN AL",
"code": 158
},
{
"name": "2/0 PECN-PEJ AL",
"code": 159
},
{
"name": "2/0 PILC",
"code": 160
},
{
"name": "2/0 WP",
"code": 161
},
{
"name": "2/0 WPAL",
"code": 162
},
{
"name": "2/0 WPCU",
"code": 163
},
{
"name": "2/0 XLPE AL",
"code": 164
},
{
"name": "2/0 XLPECN-PEJ",
"code": 165
},
{
"name": "2/0 XLPECN-PEJ AL",
"code": 166
},
{
"name": "2/0 XLPE-PEJ AL",
"code": 167
},
{
"name": "250 AAC",
"code": 168
},
{
"name": "250 AL",
"code": 169
},
{
"name": "250 B.STRD",
"code": 170
},
{
"name": "250 CU",
"code": 171
},
{
"name": "3 ACSR",
"code": 172
},
{
"name": "3 AL",
"code": 173
},
{
"name": "3 CU",
"code": 174
},
{
"name": "3 WPCU",
"code": 175
},
{
"name": "3/0 5/2 AWAC",
"code": 176
},
{
"name": "3/0 5005",
"code": 177
},
{
"name": "3/0 ACSR",
"code": 178
},
{
"name": "3/0 AL",
"code": 179
},
{
"name": "3/0 B.STRD",
"code": 180
},
{
"name": "3/0 CU",
"code": 181
},
{
"name": "3/0 WP",
"code": 182
},
{
"name": "336 AAC",
"code": 183
},
{
"name": "336 AACTW",
"code": 184
},
{
"name": "336 ACAR",
"code": 185
},
{
"name": "336 ACSR",
"code": 186
},
{
"name": "336 ACSRTW",
"code": 187
},
{
"name": "336 AL",
"code": 188
},
{
"name": "336 CU",
"code": 189
},
{
"name": "336 WPAL",
"code": 190
},
{
"name": "336.4 ACSR",
"code": 191
},
{
"name": "336.4 PAA",
"code": 192
},
{
"name": "350 EPR-PEJ CU",
"code": 193
},
{
"name": "350 PECN AL",
"code": 194
},
{
"name": "350 PECN-PEJ AL",
"code": 195
},
{
"name": "350 XLPE AL",
"code": 196
},
{
"name": "350 XLPECN-PEJ",
"code": 197
},
{
"name": "350 XLPECN-PEJ AL",
"code": 198
},
{
"name": "355 ACAR",
"code": 199
},
{
"name": "394.5 5005",
"code": 200
},
{
"name": "394.5 BNDL 5005",
"code": 201
},
{
"name": "395 AAAC",
"code": 202
},
{
"name": "395 ACAR",
"code": 203
},
{
"name": "395 ACSR",
"code": 204
},
{
"name": "395 AL",
"code": 205
},
{
"name": "397 AAAC",
"code": 206
},
{
"name": "397 AAC",
"code": 207
},
{
"name": "397 ACAR",
"code": 208
},
{
"name": "397 ACSR",
"code": 209
},
{
"name": "397 ACSRTW",
"code": 210
},
{
"name": "397 AL",
"code": 211
},
{
"name": "397 AWA",
"code": 212
},
{
"name": "397 CU",
"code": 213
},
{
"name": "4/0 AAAC",
"code": 214
},
{
"name": "4/0 AAC",
"code": 215
},
{
"name": "4/0 ACSR",
"code": 216
},
{
"name": "4/0 ACSR2",
"code": 217
},
{
"name": "4/0 ACSRTW",
"code": 218
},
{
"name": "4/0 AER.CAB",
"code": 219
},
{
"name": "4/0 AL",
"code": 220
},
{
"name": "4/0 B.STRD",
"code": 221
},
{
"name": "4/0 BNDL B.STRD",
"code": 222
},
{
"name": "4/0 CU",
"code": 223
},
{
"name": "4/0 PECN CU",
"code": 224
},
{
"name": "4/0 PILC",
"code": 225
},
{
"name": "4/0 PILC-PEJ CU",
"code": 226
},
{
"name": "4/0 THW",
"code": 227
},
{
"name": "4/0 TREE",
"code": 228
},
{
"name": "4/0 WP",
"code": 229
},
{
"name": "4/0 WPAL",
"code": 230
},
{
"name": "4/0 WPCU",
"code": 231
},
{
"name": "400K B.STRD",
"code": 232
},
{
"name": "500 AL",
"code": 233
},
{
"name": "500 CU",
"code": 234
},
{
"name": "500 EPR-PEJ CU",
"code": 235
},
{
"name": "500 PECN",
"code": 236
},
{
"name": "500 PECN CU",
"code": 237
},
{
"name": "500 PECN-PEJ CU",
"code": 238
},
{
"name": "500 PILC",
"code": 239
},
{
"name": "500 PILC-NJ",
"code": 240
},
{
"name": "500 PILC-PEJ",
"code": 241
},
{
"name": "500 PILC-PEJ CU",
"code": 242
},
{
"name": "500 THW",
"code": 243
},
{
"name": "500 XLPECN-PEJ",
"code": 244
},
{
"name": "500K B.STRD",
"code": 245
},
{
"name": "636 AAC",
"code": 246
},
{
"name": "636 ACAR",
"code": 247
},
{
"name": "636 ACSR",
"code": 248
},
{
"name": "636 ACSRTW",
"code": 249
},
{
"name": "636 AL",
"code": 250
},
{
"name": "636 B.STRD",
"code": 251
},
{
"name": "636 CU",
"code": 252
},
{
"name": "750 AAAC",
"code": 253
},
{
"name": "750 AAC",
"code": 254
},
{
"name": "750 ACSR",
"code": 255
},
{
"name": "750 AL",
"code": 256
},
{
"name": "750 AWA",
"code": 257
},
{
"name": "750 B.STRD",
"code": 258
},
{
"name": "750 CU",
"code": 259
},
{
"name": "750 EPR-PEJ",
"code": 260
},
{
"name": "750 EPR-PEJ CU",
"code": 261
},
{
"name": "750 PECN-PEJ AL",
"code": 262
},
{
"name": "750 XLPE AL",
"code": 263
},
{
"name": "750 XLPECN-PEJ",
"code": 264
},
{
"name": "750 XLPECN-PEJ AL",
"code": 265
},
{
"name": "750 XLPE-PEJ AL",
"code": 266
},
{
"name": "795 AAAC",
"code": 267
},
{
"name": "795 AAC",
"code": 268
},
{
"name": "795 ACSR",
"code": 269
},
{
"name": "795 AL",
"code": 270
},
{
"name": "1100 AL",
"code": 271
},
{
"name": "927 ACSR",
"code": 272
},
{
"name": "1272 ACSR Bittern",
"code": 273
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 35,
"name": "Medium Voltage Submersible Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar",
"description": "Medium Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Cabinet Single Phase MV",
"code": 140
},
{
"name": "Cabinet Three Phase MV",
"code": 141
},
{
"name": "Station Single Phase MV",
"code": 142
},
{
"name": "Station Three Phase MV",
"code": 143
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 8,
"name": "Medium Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector",
"description": "Medium Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase MV",
"code": 180
},
{
"name": "Three Phase MV",
"code": 181
},
{
"name": "Two Phase MV",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 10,
"name": "Medium Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service",
"description": "Medium Voltage Service Lines",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Single Phase Service MV",
"code": 170
},
{
"name": "Overhead Three Phase Service MV",
"code": 171
},
{
"name": "Overhead Two Phase Service MV",
"code": 172
},
{
"name": "Submersible Single Phase Service MV",
"code": 173
},
{
"name": "Submersible Three Phase Service MV",
"code": 174
},
{
"name": "Underground Single Phase Service MV",
"code": 175
},
{
"name": "Underground Three Phase Service MV",
"code": 176
},
{
"name": "Underground Two Phase Service MV",
"code": 177
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Phase_Attribution",
"description": "List of valid phase identifiers for the distribution system",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "C",
"code": 1
},
{
"name": "B",
"code": 2
},
{
"name": "BC",
"code": 3
},
{
"name": "A",
"code": 4
},
{
"name": "AC",
"code": 5
},
{
"name": "AB",
"code": 6
},
{
"name": "ABC",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Maximum_Voltage",
"description": "The maximum voltage, in kV",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "8 kV",
"code": 8000
},
{
"name": "15 kV",
"code": 15000
},
{
"name": "25 kV",
"code": 25000
},
{
"name": "35 kV",
"code": 35000
},
{
"name": "52 kV",
"code": 52000
},
{
"name": "72.5 kV",
"code": 72500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Medium Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1.2 kV",
"code": 1200
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "24 kV",
"code": 24000
},
{
"name": "28 kV",
"code": 28000
},
{
"name": "36 kV",
"code": 36000
},
{
"name": "44 kV",
"code": 44000
},
{
"name": "64 kV",
"code": 64000
},
{
"name": "72.5 kV",
"code": 72500
},
{
"name": "96 kV",
"code": 96000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Voltage_Nominal_Voltage",
"description": "List of valid nominal voltages for the distribution system",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.16 kV",
"code": 4160
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.9 kV",
"code": 6900
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "8.32 kV",
"code": 8320
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "12.47 kV",
"code": 12470
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "13.8 kV",
"code": 13800
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
},
{
"name": "20.78 kV",
"code": 20780
},
{
"name": "22.86 kV",
"code": 22860
},
{
"name": "23 kV",
"code": 23000
},
{
"name": "24.94 kV",
"code": 24940
},
{
"name": "34.5 kV",
"code": 34500
},
{
"name": "46 kV",
"code": 46000
},
{
"name": "69 kV",
"code": 69000
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Nominal_Voltage_LG",
"description": "Medium Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "2.4 kV",
"code": 2400
},
{
"name": "4.8 kV",
"code": 4800
},
{
"name": "6.93 kV",
"code": 6930
},
{
"name": "7.2 kV",
"code": 7200
},
{
"name": "7.62 kV",
"code": 7620
},
{
"name": "7.97 kV",
"code": 7970
},
{
"name": "12 kV",
"code": 12000
},
{
"name": "13.2 kV",
"code": 13200
},
{
"name": "14.4 kV",
"code": 14400
},
{
"name": "19.92 kV",
"code": 19920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 14,
"name": "Medium Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar",
"description": "Low Voltage Busbar",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Cabinet LV",
"code": 80
},
{
"name": "AC Station LV",
"code": 81
},
{
"name": "DC Cabinet LV",
"code": 82
},
{
"name": "DC Station LV",
"code": 83
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {
"type": "codedValue",
"name": "WS1_Electric_Busbar_Material",
"description": "List of valid Busbar Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Solid Aluminium",
"code": 401
},
{
"name": "Solid Copper",
"code": 402
},
{
"name": "Solid Steel",
"code": 403
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 5,
"name": "Low Voltage Busbar"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector",
"description": "Low Voltage Connector",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Connector LV",
"code": 120
},
{
"name": "DC Connector LV",
"code": 121
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Connector_Material",
"description": "List of valid Connector Common Conductor Material",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "ACSS/AW",
"code": 1004
},
{
"name": "ACSS/TW",
"code": 1005
},
{
"name": "AAC",
"code": 1006
},
{
"name": "AAC/TW",
"code": 1007
},
{
"name": "AAAC",
"code": 1008
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Welded Aluminum Sheath",
"code": 1010
},
{
"name": "Copper Wires with Aluminum Sheath",
"code": 1011
},
{
"name": "Copper Wires with Copper Sheath",
"code": 1012
},
{
"name": "Copper Wires with Lead Sheath",
"code": 1013
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 7,
"name": "Low Voltage Connector"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service",
"description": "List of asset types for Low Voltage Services",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead Service LV",
"code": 110
},
{
"name": "AC Underground Service LV",
"code": 112
},
{
"name": "DC Overhead Service LV",
"code": 113
},
{
"name": "DC Underground Service LV",
"code": 115
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 13,
"name": "Low Voltage Service"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor",
"description": "Low Voltage Conductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Overhead LV",
"code": 100
},
{
"name": "DC Overhead LV",
"code": 103
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {"type": "inherited"},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"normaloperatingstatus": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 6,
"name": "Low Voltage Overhead Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor",
"description": "Low VoltageUndergroundConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Underground LV",
"code": 102
},
{
"name": "DC Underground LV",
"code": 105
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 37,
"name": "Low Voltage Underground Conductor"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor",
"description": "Low VoltageSubmersibleConductor",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "AC Submersible LV",
"code": 101
},
{
"name": "DC Submersible LV",
"code": 104
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"ISCONNECTED": {"type": "inherited"},
"FROMDEVICETERMINAL": {"type": "inherited"},
"TODEVICETERMINAL": {"type": "inherited"},
"phasesnormal": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasechange": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesplan": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasesenergized": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Phase_Attribution",
"description": "Low Voltage Phase labels",
"codedValues": [
{
"name": "De-Energized",
"code": 0
},
{
"name": "c",
"code": 1
},
{
"name": "b",
"code": 2
},
{
"name": "bc",
"code": 3
},
{
"name": "a",
"code": 4
},
{
"name": "ac",
"code": 5
},
{
"name": "ab",
"code": 6
},
{
"name": "abc",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"phasefrequency": {"type": "inherited"},
"numphasesconstructed": {
"type": "codedValue",
"name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases",
"description": "Low Voltage number of phases constructed",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Phase",
"code": 1
},
{
"name": "Two Phase",
"code": 2
},
{
"name": "Three Phase",
"code": 3
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Maximum_Voltage",
"description": "Low Voltage maximum voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "229 V",
"code": 229
},
{
"name": "253 V",
"code": 253
},
{
"name": "264 V",
"code": 264
},
{
"name": "440 V",
"code": 440
},
{
"name": "528 V",
"code": 528
},
{
"name": "660 V",
"code": 660
},
{
"name": "759 V",
"code": 759
},
{
"name": "1.1 kV",
"code": 1100
},
{
"name": "480 V",
"code": 480
},
{
"name": "240 V",
"code": 240
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maxoperatingvoltage": {
"type": "codedValue",
"name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL",
"description": "List of Low Voltage maximum voltages",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "600 V",
"code": 600
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltage": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Nominal_Voltage",
"description": "Low Voltage Line to Line Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "208 V",
"code": 208
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
},
{
"name": "600 V",
"code": 600
},
{
"name": "400 V",
"code": 400
},
{
"name": "216 V",
"code": 216
},
{
"name": "12 V",
"code": 12
},
{
"name": "24 V",
"code": 24
},
{
"name": "48 V",
"code": 48
},
{
"name": "96 V",
"code": 96
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"nominalvoltagelg": {
"type": "codedValue",
"name": "WS1_Electric_Low_Nominal_Voltage_LG",
"description": "Low Voltage Line to Ground Nominal Operating Voltage",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "120 V",
"code": 120
},
{
"name": "125 V",
"code": 125
},
{
"name": "277 V",
"code": 277
},
{
"name": "240 V",
"code": 240
},
{
"name": "480 V",
"code": 480
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"grounding": {"type": "inherited"},
"commonconductortype": {
"type": "codedValue",
"name": "WS1_Electric_Low_Voltage_Conductor_Material",
"description": "Low Voltage conductor type",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Other",
"code": 999
},
{
"name": "ACSR",
"code": 1001
},
{
"name": "ACSR/AW",
"code": 1002
},
{
"name": "ACSR/TW",
"code": 1003
},
{
"name": "AAC",
"code": 1006
},
{
"name": "ACAR",
"code": 1009
},
{
"name": "Duplex",
"code": 2001
},
{
"name": "Triplex",
"code": 2002
},
{
"name": "Quadraplex",
"code": 2003
},
{
"name": "6 Duplex Shepherd",
"code": 2004
},
{
"name": "6 Triplex Voluta",
"code": 2005
},
{
"name": "4 Triplex Periwinkle",
"code": 2006
},
{
"name": "4 Quad Hackney",
"code": 2007
},
{
"name": "2 Triplex Cockle",
"code": 2008
},
{
"name": "2 Quad Palimino",
"code": 2009
},
{
"name": "1/0 Tri Janithina",
"code": 2010
},
{
"name": "1/0 Quad Constena",
"code": 2011
},
{
"name": "4/0 Triplex Cerapus",
"code": 2012
},
{
"name": "4/0 Quad Appoloosa",
"code": 2013
},
{
"name": "10 THHN",
"code": 2014
},
{
"name": "8 THHN",
"code": 2015
},
{
"name": "6 THHN",
"code": 2016
},
{
"name": "6 Duplex Claflin",
"code": 2017
},
{
"name": "4 Duplex Delgado",
"code": 2018
},
{
"name": "4 Triplex Vasser",
"code": 2019
},
{
"name": "2 Copper",
"code": 2020
},
{
"name": "1/0 Triplex Brenau",
"code": 2021
},
{
"name": "2/0 Triplex",
"code": 2022
},
{
"name": "4/0 Copper",
"code": 2023
},
{
"name": "4/0 Tri Sweebriar",
"code": 2024
},
{
"name": "250 AL",
"code": 2025
},
{
"name": "350 Triplex Wesleyan",
"code": 2026
},
{
"name": "500 Copper",
"code": 2027
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"neutraltype": {"type": "inherited"},
"sharedneutral": {"type": "inherited"},
"lifecyclestatus": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"primaryphaseshift": {"type": "inherited"},
"isvalidloop": {"type": "inherited"},
"conductormaterial": {"type": "inherited"},
"conductorinsulationmaterial": {"type": "inherited"},
"conductorsize": {"type": "inherited"},
"kcmil": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"ISCONNECTED": 2,
"FROMDEVICETERMINAL": 0,
"TODEVICETERMINAL": 0,
"GLOBALID": null,
"SUBNETWORKNAME": "Unknown",
"SUPPORTEDSUBNETWORKNAME": "Unknown",
"SUPPORTINGSUBNETWORKNAME": "Unknown",
"assetid": null,
"phasesnormal": 0,
"phasechange": null,
"phasesplan": 0,
"phasesenergized": 0,
"phasefrequency": null,
"numphasesconstructed": null,
"maxvoltage": null,
"maxoperatingvoltage": null,
"nominalvoltage": null,
"nominalvoltagelg": null,
"grounding": null,
"commonconductortype": null,
"neutraltype": null,
"sharedneutral": null,
"tiername": null,
"lifecyclestatus": 2,
"inservicedate": null,
"retireddate": null,
"measuredlength": null,
"spatialsource": null,
"spatialconfidence": null,
"ownedby": 3,
"maintby": 1,
"labeltext": null,
"notes": null,
"installdate": null,
"ohm": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"normaloperatingstatus": null,
"conductorsperphase": null,
"constructionstatus": 6,
"primaryphaseshift": null,
"sectionid": null,
"isvalidloop": null,
"WithstandRating": null,
"conductormaterial": null,
"conductorinsulationmaterial": null,
"conductorsize": null,
"kcmil": null,
"conductorfulldiameter": null,
"conductorinsulationthickness": null,
"conductorinsulationthich_m": null,
"conductorsheaththickness": null,
"conductorsheaththickness_metr": null,
"injectionid": null,
"injectiondate": null,
"conductorspacing": null,
"phaseorder": null,
"workorder": null,
"VALIDATIONSTATUS": 6,
"lpfield": null
},
"code": 38,
"name": "Low Voltage Submersible Conductor"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"hasM": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"effectiveMinScale": 12000,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1757937049000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 450,
"name": "Electric/Fiber Conduit",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
},
"copyrightText": "",
"parentLayer": {
"id": 400,
"name": "Electric"
},
"subLayers": [],
"minScale": 10000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
0,
0,
255
],
"width": 0.2
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 674290.8904372454,
"ymin": 643558.6110127419,
"xmax": 707051.7212409116,
"ymax": 687801.6045475751,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "ASSETGROUP",
"typeIdField": "ASSETGROUP",
"subtypeFieldName": "ASSETGROUP",
"subtypeField": "ASSETGROUP",
"defaultSubtypeCode": 0,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "ASSETGROUP",
"type": "esriFieldTypeInteger",
"alias": "Asset Group",
"domain": null
},
{
"name": "ASSETTYPE",
"type": "esriFieldTypeSmallInteger",
"alias": "Asset Type",
"domain": null
},
{
"name": "lifecyclestatus",
"type": "esriFieldTypeSmallInteger",
"alias": "Lifecycle Status",
"domain": {
"type": "codedValue",
"name": "WS1_Lifecycle_Status",
"description": "Valid lifecycle states for the assets.",
"codedValues": [
{
"name": "Out of Service",
"code": 0
},
{
"name": "Proposed",
"code": 1
},
{
"name": "In Service",
"code": 2
},
{
"name": "Design",
"code": 3
},
{
"name": "Planned Removal",
"code": 4
},
{
"name": "Abandoned",
"code": 5
},
{
"name": "Removed",
"code": 6
},
{
"name": "Retired",
"code": 7
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "SHAPE.STLength()",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S180_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Ground",
"description": "Asset Types for Ground Cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bare Ground",
"code": 801
},
{
"name": "Covered Ground",
"code": 802
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 801,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Duct_Bank",
"description": "Lines used to represent duct banks in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Duct Bank",
"code": 81
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "range",
"name": "WS1_Wire_Duct_Bank_Width",
"description": "Width of the duct bank",
"range": [
0,
50
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Bank_Material",
"description": "List of materials for duct banks",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumcapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"usedcapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"availablecapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 102,
"name": "Wire Duct Bank"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Aerial_Support",
"description": "Lines used to represent aerial supports in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridge Suspension",
"code": 121
},
{
"name": "Other Suspension",
"code": 122
},
{
"name": "Spanguy",
"code": 123
},
{
"name": "Aerial Span",
"code": 125
},
{
"name": "Communications Support Guy",
"code": 126
},
{
"name": "Lashing Guy",
"code": 127
},
{
"name": "Guy Wire",
"code": 128
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Guy_Diameter_in",
"description": "List of diameters of guys in inches",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1/4\"",
"code": 6
},
{
"name": "5/16\"",
"code": 7
},
{
"name": "3/8\"",
"code": 9
},
{
"name": "7/16\"",
"code": 11
},
{
"name": "1/2\"",
"code": 12
},
{
"name": "9/16\"",
"code": 14
},
{
"name": "1\"",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Aerial_Support_Material",
"description": "List of materials used for aerial supports",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Steel",
"code": 6
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 103,
"name": "Wire Aerial Support"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Trench",
"description": "Lines used to represent trenches in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trench",
"code": 101
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "range",
"name": "WS1_Wire_Trench_Width",
"description": "Depth of trench",
"range": [
0,
30
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Trench_Material",
"description": "List of valid trench materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Open",
"code": 11
},
{
"name": "Earth Covered",
"code": 12
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 104,
"name": "Wire Trench"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Tunnel",
"description": "Lines used to represent access tunnels in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Tunnel",
"code": 221
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 112,
"name": "Access Tunnel"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Conduit",
"description": "The Asset Types for the Electric High Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit HV",
"code": 114
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 105,
"name": "Electric High Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit",
"description": "The Asset Types for the Electric Low Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit LV",
"code": 118
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 106,
"name": "Electric Low Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit",
"description": "The Asset Types for the Electric Medium Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit MV",
"code": 112
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 107,
"name": "Electric Medium Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Connector",
"description": "Lines used to represent connecters inside vaults and handholes in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Vault Duct",
"code": 181
},
{
"name": "Handhole Duct",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 111,
"name": "Connector Line"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway",
"description": "Pathway for High Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway HV",
"code": 231
},
{
"name": "Underground Pathway HV",
"code": 232
},
{
"name": "Submersible Pathway HV",
"code": 233
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 113,
"name": "Electric High Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway",
"description": "Pathway for Medium Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway MV",
"code": 241
},
{
"name": "Underground Pathway MV",
"code": 242
},
{
"name": "Submersible Pathway MV",
"code": 243
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 114,
"name": "Electric Medium Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway",
"description": "Pathway for Low Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway LV",
"code": 251
},
{
"name": "Underground Pathway LV",
"code": 252
},
{
"name": "Submersible Pathway LV",
"code": 253
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 115,
"name": "Electric Low Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Microduct_Pathway",
"description": "Asset Types for Microduct Casings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Microduct Casing",
"code": 85
},
{
"name": "Multiple Microduct Casing",
"code": 86
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 118,
"name": "Wire Microduct Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Casing",
"description": "",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Casing",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 101,
"name": "Wire Casing"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Linear_Marker",
"description": "",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Buried Cable Marker",
"code": 462
},
{
"name": "Covered Marker",
"code": 465
},
{
"name": "Terrain Marker",
"code": 466
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 124,
"name": "Linear Marker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Communications_Conduit",
"description": "Lines used to represent conduit in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit",
"code": 111
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Communications_Conduit_Type",
"description": "The type of conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Abandoned Electric Conduit",
"code": 101
},
{
"name": "Abandoned Gas Pipe",
"code": 102
},
{
"name": "Abandoned Water Main",
"code": 103
},
{
"name": "Sewer pipe",
"code": 104
},
{
"name": "Storm Pipe",
"code": 105
},
{
"name": "Abandoned Communication Conduit",
"code": 106
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 109,
"name": "Communications Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Static_Wire",
"description": "Static Wire modeled in the structure network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 860
},
{
"name": "Single",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"id": 802,
"name": "Static Wire"
}
],
"subtypes": [
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_IFPower_2918_UnknownAssetType",
"description": "The AssetType domain for the Unknown AssetGroup.",
"codedValues": [
{
"name": "Unknown",
"code": 0
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": null,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 0,
"name": "Unknown"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Ground",
"description": "Asset Types for Ground Cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bare Ground",
"code": 801
},
{
"name": "Covered Ground",
"code": 802
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 801,
"name": "Ground"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Duct_Bank",
"description": "Lines used to represent duct banks in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Duct Bank",
"code": 81
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "range",
"name": "WS1_Wire_Duct_Bank_Width",
"description": "Width of the duct bank",
"range": [
0,
50
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Bank_Material",
"description": "List of materials for duct banks",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"maximumcapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"usedcapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"availablecapacity": {
"type": "range",
"name": "WS1_Wire_Number_of_Ducts",
"description": "",
"range": [
0,
64
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 102,
"name": "Wire Duct Bank"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Aerial_Support",
"description": "Lines used to represent aerial supports in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Bridge Suspension",
"code": 121
},
{
"name": "Other Suspension",
"code": 122
},
{
"name": "Spanguy",
"code": 123
},
{
"name": "Aerial Span",
"code": 125
},
{
"name": "Communications Support Guy",
"code": 126
},
{
"name": "Lashing Guy",
"code": 127
},
{
"name": "Guy Wire",
"code": 128
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Guy_Diameter_in",
"description": "List of diameters of guys in inches",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "1/4\"",
"code": 6
},
{
"name": "5/16\"",
"code": 7
},
{
"name": "3/8\"",
"code": 9
},
{
"name": "7/16\"",
"code": 11
},
{
"name": "1/2\"",
"code": 12
},
{
"name": "9/16\"",
"code": 14
},
{
"name": "1\"",
"code": 25
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Aerial_Support_Material",
"description": "List of materials used for aerial supports",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Steel",
"code": 6
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 103,
"name": "Wire Aerial Support"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Trench",
"description": "Lines used to represent trenches in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Trench",
"code": 101
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {
"type": "range",
"name": "WS1_Wire_Trench_Width",
"description": "Depth of trench",
"range": [
0,
30
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Trench_Material",
"description": "List of valid trench materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Open",
"code": 11
},
{
"name": "Earth Covered",
"code": 12
},
{
"name": "Other",
"code": 20
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 104,
"name": "Wire Trench"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Tunnel",
"description": "Lines used to represent access tunnels in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Tunnel",
"code": 221
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 112,
"name": "Access Tunnel"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Conduit",
"description": "The Asset Types for the Electric High Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit HV",
"code": 114
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 105,
"name": "Electric High Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit",
"description": "The Asset Types for the Electric Low Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit LV",
"code": 118
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 106,
"name": "Electric Low Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit",
"description": "The Asset Types for the Electric Medium Voltage Conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit MV",
"code": 112
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 107,
"name": "Electric Medium Voltage Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Connector",
"description": "Lines used to represent connecters inside vaults and handholes in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Vault Duct",
"code": 181
},
{
"name": "Handhole Duct",
"code": 182
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 111,
"name": "Connector Line"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway",
"description": "Pathway for High Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway HV",
"code": 231
},
{
"name": "Underground Pathway HV",
"code": 232
},
{
"name": "Submersible Pathway HV",
"code": 233
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 113,
"name": "Electric High Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway",
"description": "Pathway for Medium Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway MV",
"code": 241
},
{
"name": "Underground Pathway MV",
"code": 242
},
{
"name": "Submersible Pathway MV",
"code": 243
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 114,
"name": "Electric Medium Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway",
"description": "Pathway for Low Voltage cables",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Overhead Pathway LV",
"code": 251
},
{
"name": "Underground Pathway LV",
"code": 252
},
{
"name": "Submersible Pathway LV",
"code": 253
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 115,
"name": "Electric Low Voltage Cable Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Microduct_Pathway",
"description": "Asset Types for Microduct Casings",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Single Microduct Casing",
"code": 85
},
{
"name": "Multiple Microduct Casing",
"code": 86
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 118,
"name": "Wire Microduct Pathway"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Wire_Casing",
"description": "",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Casing",
"code": 11
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 101,
"name": "Wire Casing"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Linear_Marker",
"description": "",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Buried Cable Marker",
"code": 462
},
{
"name": "Covered Marker",
"code": 465
},
{
"name": "Terrain Marker",
"code": 466
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 124,
"name": "Linear Marker"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Communications_Conduit",
"description": "Lines used to represent conduit in the Structure Network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Conduit",
"code": 111
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"diameter": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Wire_Structure_Line_Duct_Material",
"description": "List of duct materials",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Composite",
"code": 3
},
{
"name": "Fiberglass",
"code": 4
},
{
"name": "Poured Concrete",
"code": 8
},
{
"name": "Precast Concrete",
"code": 9
},
{
"name": "Plastic",
"code": 10
},
{
"name": "Other",
"code": 20
},
{
"name": "PVC",
"code": 15
},
{
"name": "RGS",
"code": 16
},
{
"name": "HDPE",
"code": 17
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"designtype": {
"type": "codedValue",
"name": "WS1_Communications_Conduit_Type",
"description": "The type of conduit",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Abandoned Electric Conduit",
"code": 101
},
{
"name": "Abandoned Gas Pipe",
"code": 102
},
{
"name": "Abandoned Water Main",
"code": 103
},
{
"name": "Sewer pipe",
"code": 104
},
{
"name": "Storm Pipe",
"code": 105
},
{
"name": "Abandoned Communication Conduit",
"code": 106
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"constructionstatus": {"type": "inherited"},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 109,
"name": "Communications Conduit"
},
{
"domains": {
"ASSETTYPE": {
"type": "codedValue",
"name": "WS1_Asset_Type_Structure_Line_Static_Wire",
"description": "Static Wire modeled in the structure network",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "Double",
"code": 860
},
{
"name": "Single",
"code": 861
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"ASSOCIATIONSTATUS": {"type": "inherited"},
"materialcode": {
"type": "codedValue",
"name": "WS1_Electric_StaticWire_Material",
"description": "List of static wire types",
"codedValues": [
{
"name": "Unknown",
"code": 0
},
{
"name": "ACSR",
"code": 1001
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"lifecyclestatus": {"type": "inherited"},
"spatialsource": {"type": "inherited"},
"spatialconfidence": {"type": "inherited"},
"ownedby": {"type": "inherited"},
"maintby": {"type": "inherited"},
"constructionstatus": {"type": "inherited"},
"ohm": {
"type": "range",
"name": "WS1_Electric_Ohms_per_KM",
"description": "Range domain of valid values for Electric Cable resistance per KM",
"range": [
0,
999999
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
},
"VALIDATIONSTATUS": {"type": "inherited"}
},
"defaultValues": {
"ASSETGROUP": null,
"ASSETTYPE": 0,
"ASSOCIATIONSTATUS": 0,
"SUBNETWORKNAME": "Unknown",
"GLOBALID": null,
"assetid": null,
"diameter": null,
"materialcode": null,
"distance": null,
"labeltext": null,
"installdate": null,
"retireddate": null,
"inservicedate": null,
"maximumcapacity": null,
"usedcapacity": null,
"availablecapacity": null,
"measuredlength": null,
"lifecyclestatus": 2,
"spatialsource": null,
"spatialconfidence": null,
"notes": null,
"ownedby": 3,
"maintby": 1,
"designtype": null,
"searchdistance": null,
"created_user": null,
"created_date": null,
"last_edited_user": null,
"last_edited_date": null,
"constructionstatus": 6,
"sectionid": null,
"ohm": null,
"workorder": null,
"VALIDATIONSTATUS": 6
},
"code": 802,
"name": "Static Wire"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"hasM": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1757937005000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 600,
"name": "Zoning",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 610,
"name": "Area of Impact"
},
{
"id": 620,
"name": "Overlay Zone"
},
{
"id": 630,
"name": "Zoning"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 669337.9004999995,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 693960.124499999,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 610,
"name": "Area of Impact",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 600,
"name": "Zoning"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
54,
74,
97,
0
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
238,
118,
35,
255
],
"width": 2
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 669337.9004999995,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 693960.124499999,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GlobalID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 100,
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 20,
"domain": {
"type": "codedValue",
"name": "WS3_AOI Type",
"description": "Valid area of impact type values",
"codedValues": [
{
"name": "Active",
"code": "Active"
},
{
"name": "Inactive",
"code": "Inactive"
},
{
"name": "Proposed",
"code": "Proposed"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
}
},
{
"name": "ActiveDate",
"type": "esriFieldTypeDate",
"alias": "Active Date",
"length": 8,
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {},
"indexes": [
{
"name": "UUID_25",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075261000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 620,
"name": "Overlay Zone",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 600,
"name": "Zoning"
},
"subLayers": [],
"minScale": 12000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Type",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriPFS",
"url": "6fdb41372a48f71280e3bd63567ea07d",
"imageData": "iVBORw0KGgoAAAANSUhEUgAAAAwAAAAMCAYAAABWdVznAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAK0lEQVQokWNhIBGwUKLhPwMDAyMhPguSALIkTj4LJU4iCrAgsUf9wIAjXgCgCAk6OP9WWgAAAABJRU5ErkJggg==",
"contentType": "image/png",
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
104,
104,
104,
255
],
"width": 0.01
},
"width": 9,
"height": 9,
"angle": 0,
"xoffset": 0,
"yoffset": 0,
"xscale": 1,
"yscale": 1
},
"value": "PT",
"label": "Planned Transition (PT)"
},
{
"symbol": {
"type": "esriPFS",
"url": "408a797e815861da36172d5e1a1af9a4",
"imageData": "iVBORw0KGgoAAAANSUhEUgAAAAwAAAAMCAYAAABWdVznAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAALUlEQVQokWNhIBGwkK/h6P//DNaMjIT4LHABZEk8fBbynUQkYIGzRv3AgDNeADW+HVYZQgPYAAAAAElFTkSuQmCC",
"contentType": "image/png",
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
178,
178,
178,
255
],
"width": 0.01
},
"width": 9,
"height": 9,
"angle": 0,
"xoffset": 0,
"yoffset": 0,
"xscale": 1,
"yscale": 1
},
"value": "PT&T-1",
"label": "Planned Transition & Tower 1 (PT & T1)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSForwardDiagonal",
"color": [
178,
178,
178,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
104,
104,
104,
255
],
"width": 0.01
}
},
"value": "PUD",
"label": "Planned Unit Development (PUD)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSHorizontal",
"color": [
0,
112,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
107,
126,
147,
255
],
"width": 0.01
}
},
"value": "T-1",
"label": "Tower 1 (T-1)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSHorizontal",
"color": [
204,
204,
204,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
156,
156,
156,
255
],
"width": 0.01
}
},
"value": "T-2",
"label": "Tower 2 (T-2)"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 25,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 676996.25,
"ymin": 646282.25,
"xmax": 704767.3125,
"ymax": 677721.0689999983,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "TYPE",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 10,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Overlay Type",
"description": "Valid planning overlay type values",
"codedValues": [
{
"name": "Planned Transition",
"code": "PT"
},
{
"name": "Planned Transition & Tower 1",
"code": "PT&T-1"
},
{
"name": "Planned Unit Development",
"code": "PUD"
},
{
"name": "Tower 1",
"code": "T-1"
},
{
"name": "Tower 2",
"code": "T-2"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "I476Type",
"fields": "Type",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "UUID_220",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S183_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 630,
"name": "Zoning",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 600,
"name": "Zoning"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Name",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
227,
255,
190,
255
],
"outline": null
},
"value": "RE",
"label": "Residential Estate (RE)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
204,
255
],
"outline": null
},
"value": "RP",
"label": "Residential Park (RP)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
0,
255
],
"outline": null
},
"value": "R1",
"label": "Single Dwelling Residential (R1)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
191,
0,
255
],
"outline": null
},
"value": "R2",
"label": "Mixed Residential (R2)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
220,
98,
0,
255
],
"outline": null
},
"value": "TN",
"label": "Traditional Neighborhood (TN)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
204,
255,
0,
255
],
"outline": null
},
"value": "RMH",
"label": "Residential Mobile Home (RMH)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
76,
0,
255
],
"outline": null
},
"value": "R3",
"label": "Multiple Dwelling Residential (R3)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
223,
255,
255
],
"outline": null
},
"value": "R3A",
"label": "Residential Mixed Use (R3A)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
132,
168,
255
],
"outline": null
},
"value": "PB",
"label": "Professional Business Office (PB)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
230,
0,
165,
255
],
"outline": null
},
"value": "CC",
"label": "Central Commercial (CC)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
0,
255
],
"outline": null
},
"value": "LC",
"label": "Limited Commercial (LC)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
178,
235,
255
],
"outline": null
},
"value": "HC",
"label": "Highway Commercial (HC)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
97,
179,
158,
255
],
"outline": null
},
"value": "R&D",
"label": "Research and Development (R&D)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
204,
204,
204,
255
],
"outline": null
},
"value": "LM",
"label": "Light Manufacturing and Heavy Commercial (LM)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
52,
52,
52,
255
],
"outline": null
},
"value": "I&M",
"label": "Industrial and Manufacturing (I&M)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
153,
102,
204,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.4
}
},
"value": "FBC",
"label": "Form Based Code (FBC)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
56,
168,
0,
255
],
"outline": null
},
"value": "P",
"label": "Public (P)"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
188,
252,
179,
255
],
"toColor": [
188,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
238,
252,
255
],
"toColor": [
179,
238,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
210,
179,
252,
255
],
"toColor": [
210,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
244,
199,
255
],
"toColor": [
252,
244,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
182,
204,
252,
255
],
"toColor": [
182,
204,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
207,
252,
230,
255
],
"toColor": [
207,
252,
230,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
232,
255
],
"toColor": [
252,
184,
232,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
244,
215,
252,
255
],
"toColor": [
244,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
228,
252,
182,
255
],
"toColor": [
228,
252,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
229,
252,
255
],
"toColor": [
212,
229,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
204,
255
],
"toColor": [
202,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
252,
212,
255
],
"toColor": [
230,
252,
212,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
216,
207,
255
],
"toColor": [
252,
216,
207,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
250,
255
],
"toColor": [
179,
252,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
207,
227,
255
],
"toColor": [
252,
207,
227,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 50,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 673765.1440000013,
"ymin": 643478.2014999986,
"xmax": 707353.4959999993,
"ymax": 689852.7534999996,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 5,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Zoning Name",
"description": "Valid planning zoning name values",
"codedValues": [
{
"name": "Residential Estate",
"code": "RE"
},
{
"name": "Residential Park",
"code": "RP"
},
{
"name": "Single Dwelling Residential",
"code": "R1"
},
{
"name": "Mixed Residential",
"code": "R2"
},
{
"name": "Traditional Neighborhood",
"code": "TN"
},
{
"name": "Residential Mobile Home",
"code": "RMH"
},
{
"name": "Multiple Dwelling Residential",
"code": "R3"
},
{
"name": "Residential Mixed Use",
"code": "R3A"
},
{
"name": "Professional Business Office",
"code": "PB"
},
{
"name": "Central Commercial",
"code": "CC"
},
{
"name": "Limited Commercial",
"code": "LC"
},
{
"name": "Highway Commercial",
"code": "HC"
},
{
"name": "Light Manufacturing and Heavy Commercial",
"code": "LM"
},
{
"name": "Industrial and Manufacturing",
"code": "I&M"
},
{
"name": "Research and Development",
"code": "R&D"
},
{
"name": "Public",
"code": "P"
},
{
"name": "Downtown",
"code": "DT"
},
{
"name": "Form Based Code",
"code": "FBC"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "I493Name",
"fields": "Name",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S200_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 700,
"name": "Comprehensive Plan",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 710,
"name": "Area of Impact"
},
{
"id": 720,
"name": "Comprehensive Plan"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 662747.3640000001,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 696379.2929999977,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 710,
"name": "Area of Impact",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 700,
"name": "Comprehensive Plan"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
54,
74,
97,
0
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
238,
118,
35,
255
],
"width": 2
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 669337.9004999995,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 693960.124499999,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GlobalID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 100,
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 20,
"domain": {
"type": "codedValue",
"name": "WS3_AOI Type",
"description": "Valid area of impact type values",
"codedValues": [
{
"name": "Active",
"code": "Active"
},
{
"name": "Inactive",
"code": "Inactive"
},
{
"name": "Proposed",
"code": "Proposed"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
}
},
{
"name": "ActiveDate",
"type": "esriFieldTypeDate",
"alias": "Active Date",
"length": 8,
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {},
"indexes": [
{
"name": "UUID_25",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075261000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 720,
"name": "Comprehensive Plan",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 700,
"name": "Comprehensive Plan"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Transect",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
131,
117,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
255,
255,
0
],
"width": 2
}
},
"value": "Natural and Open Space",
"label": "1 Parks and Open Space"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
170,
170,
170,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSNull",
"color": [
0,
0,
0,
0
],
"width": 0
}
},
"value": "Industrial",
"label": "3 Industrial"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
245,
211,
18,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
255,
255,
0
],
"width": 2
}
},
"value": "Suburban",
"label": "4 Suburban"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
238,
118,
35,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
170,
0,
0
],
"width": 3
}
},
"value": "General Urban",
"label": "5 General Urban"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
153,
51,
51,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
170,
0,
0
],
"width": 3
}
},
"value": "Mixed Use Centers and Corridors",
"label": "6 Mixed Use Centers and Corridors"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
187,
158,
117,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
255,
255,
0
],
"width": 2
}
},
"value": "Urban Core",
"label": "7 Urban Core"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
54,
74,
97,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
255,
255,
0
],
"width": 2
}
},
"value": "Special Use",
"label": "8 Special Use"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 50,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 662747.3640000001,
"ymin": 640769.5399999991,
"xmax": 707273.2749999985,
"ymax": 696379.2929999977,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Transect",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Transect",
"type": "esriFieldTypeString",
"alias": "Transect",
"length": 40,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Comprehensive Plan 2022 Tract Transect",
"description": "Valid planning comprehensive plan 2022 tract transect values",
"codedValues": [
{
"name": "General Urban",
"code": "General Urban"
},
{
"name": "Industrial",
"code": "Industrial"
},
{
"name": "Mixed Use Centers and Corridors",
"code": "Mixed Use Centers and Corridors"
},
{
"name": "Natural and Open Space",
"code": "Natural and Open Space"
},
{
"name": "Special Use",
"code": "Special Use"
},
{
"name": "Suburban",
"code": "Suburban"
},
{
"name": "Urban Core",
"code": "Urban Core"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S206_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 800,
"name": "Land Use",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 810,
"name": "Area of Impact"
},
{
"id": 820,
"name": "Land Use"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 669337.9004999995,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 693960.124499999,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 810,
"name": "Area of Impact",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 800,
"name": "Land Use"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
54,
74,
97,
0
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
238,
118,
35,
255
],
"width": 2
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 669337.9004999995,
"ymin": 638198.1115000024,
"xmax": 712633.4855000004,
"ymax": 693960.124499999,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GlobalID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 100,
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 20,
"domain": {
"type": "codedValue",
"name": "WS3_AOI Type",
"description": "Valid area of impact type values",
"codedValues": [
{
"name": "Active",
"code": "Active"
},
{
"name": "Inactive",
"code": "Inactive"
},
{
"name": "Proposed",
"code": "Proposed"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
}
},
{
"name": "ActiveDate",
"type": "esriFieldTypeDate",
"alias": "Active Date",
"length": 8,
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {},
"indexes": [
{
"name": "UUID_25",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075261000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 820,
"name": "Land Use",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 800,
"name": "Land Use"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "StandardLandUseType",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
190,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSNull",
"color": [
0,
0,
0,
0
],
"width": 0
}
},
"value": "10",
"label": "SFD - Single Family Dwelling"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
190,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "40",
"label": "ACB - Accessory Building/Structure"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
211,
127,
255
],
"outline": null
},
"value": "20",
"label": "MFD - Multi-Family Dwelling"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
230,
230,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "30",
"label": "RSL - Other Residential"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
127,
127,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "80",
"label": "RTL - Retail Trade"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
223,
115,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "70",
"label": "WHL - Wholesale Trade"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
190,
232,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "100",
"label": "SRV - Services"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
205,
102,
102,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "110",
"label": "CBDRL - Central Business District Retail Trade"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
205,
102,
102,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "120",
"label": "CBDSV - Central Business District Services"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
223,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "90",
"label": "EDU - Educational"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
163,
255,
115,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "130",
"label": "CER - Cultural, Entertainment & Recreation"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
130,
130,
130,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "50",
"label": "I&M - Industrial & Manufacturing"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
178,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "60",
"label": "TCU - Transportation, Communication & Utilites"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
233,
255,
190,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "140",
"label": "AGL - Agricultural"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
158,
187,
215,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "150",
"label": "MNG - Mining"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
225,
225,
225,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "160",
"label": "VCT - Vacant"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "180",
"label": "ROW - Streets & Right-of-Ways"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
191,
217,
242,
255
],
"outline": null
},
"value": "170",
"label": "WTR - Water Areas"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
188,
252,
179,
255
],
"toColor": [
188,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
235,
252,
255
],
"toColor": [
179,
235,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
179,
252,
255
],
"toColor": [
216,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
244,
199,
255
],
"toColor": [
252,
244,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
204,
252,
220,
255
],
"toColor": [
204,
252,
220,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
246,
212,
252,
255
],
"toColor": [
246,
212,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
182,
204,
252,
255
],
"toColor": [
182,
204,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
207,
182,
255
],
"toColor": [
252,
207,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
251,
255
],
"toColor": [
252,
184,
251,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
183,
252,
255
],
"toColor": [
179,
183,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
252,
246,
255
],
"toColor": [
212,
252,
246,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
223,
252,
184,
255
],
"toColor": [
223,
252,
184,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
215,
232,
255
],
"toColor": [
252,
215,
232,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
215,
229,
252,
255
],
"toColor": [
215,
229,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
210,
199,
252,
255
],
"toColor": [
210,
199,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
182,
212,
255
],
"toColor": [
252,
182,
212,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
189,
252,
200,
255
],
"toColor": [
189,
252,
200,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 25,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 674610.0245000012,
"ymin": 643478.2014999986,
"xmax": 707353.4959999993,
"ymax": 689855.8580000028,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "StandardLandUseType",
"typeIdField": "StandardLandUseType",
"subtypeFieldName": "StandardLandUseType",
"subtypeField": "StandardLandUseType",
"defaultSubtypeCode": 10,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "StandardLandUseType",
"type": "esriFieldTypeSmallInteger",
"alias": "Standard Land Use Type",
"domain": null
},
{
"name": "StandardLandUseCode",
"type": "esriFieldTypeSmallInteger",
"alias": "Standard Land Use Code",
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "I491StandardLand",
"fields": "StandardLandUseCode",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "I491StandardLand_1",
"fields": "StandardLandUseType",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "UUID_235",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S198_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"types": [
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SFD",
"description": "Valid standard land use code SFD values",
"codedValues": [
{
"name": "1110 - Single Family Detached",
"code": 1110
},
{
"name": "1140 - Townhome/Single Family Attached (separate ownership)",
"code": 1140
},
{
"name": "1150 - Mobile Home",
"code": 1150
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 10,
"name": "SFD - Single Family Dwelling"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC MFD",
"description": "Valid standard land use code MFD values",
"codedValues": [
{
"name": "1120 - Two Units",
"code": 1120
},
{
"name": "1130 - Three or More Units",
"code": 1130
},
{
"name": "1300 - Residential Motel",
"code": 1300
},
{
"name": "1400 - Mobile Home Park",
"code": 1400
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 20,
"name": "MFD - Multi-Family Dwelling"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RSL",
"description": "Valid standard land use code RSL values",
"codedValues": [
{
"name": "1210 - Group Home",
"code": 1210
},
{
"name": "1241 - Retirement Home",
"code": 1241
},
{
"name": "1500 - Hotel/Motel",
"code": 1500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 30,
"name": "RSL - Other Residential"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC ACB",
"description": "Valid standard land use ACB values",
"codedValues": [
{
"name": "1950 - Detached Garage",
"code": 1950
},
{
"name": "1951 - Attached Garage",
"code": 1951
},
{
"name": "1952 - Covered Carport",
"code": 1952
},
{
"name": "1958 - Pool House",
"code": 1958
},
{
"name": "1960 - Shed",
"code": 1960
},
{
"name": "1970 - Deck",
"code": 1970
},
{
"name": "1971 - Pergola, Covered Deck, Patio Cover",
"code": 1971
},
{
"name": "1972 - Green House",
"code": 1972
},
{
"name": "1975 - ADA Ramp",
"code": 1975
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 40,
"name": "ACB - Accessory Building/Structure"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC I&M",
"description": "Valid standard land use code I&M values",
"codedValues": [
{
"name": "2100 - Food and Kindred Products",
"code": 2100
},
{
"name": "2200 - Textile Products",
"code": 2200
},
{
"name": "2300 - Apparel & other finished products made from fabrics, leather or similar",
"code": 2300
},
{
"name": "2400 - Lumber & Wood Products (except furniture)",
"code": 2400
},
{
"name": "2500 - Furniture & Fixtures",
"code": 2500
},
{
"name": "2600 - Paper & Allied Products",
"code": 2600
},
{
"name": "2700 - Printing, Publishing & Allied Industries",
"code": 2700
},
{
"name": "2800 - Chemicals & Allied Products",
"code": 2800
},
{
"name": "2900 - Petroleum Refining & Related Industries",
"code": 2900
},
{
"name": "3100 - Rubber & Miscellaneous Plastic Products",
"code": 3100
},
{
"name": "3200 - Stone, Clay & Glass Products",
"code": 3200
},
{
"name": "3300 - Metal Industries",
"code": 3300
},
{
"name": "3400 - Fabricated Metal Products",
"code": 3400
},
{
"name": "3500 - Professional, Scientific & Controlling Instruments; Research Instruments & Associated",
"code": 3500
},
{
"name": "3900 - Miscellaneous Manufacturing",
"code": 3900
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 50,
"name": "I&M - Industrial & Manufacturing"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC TCU",
"description": "Valid standard land use code TCU values",
"codedValues": [
{
"name": "4110 - Railroad Transportation",
"code": 4110
},
{
"name": "4210 - Bus Transportation",
"code": 4210
},
{
"name": "4220 - Motor Freight Transportation",
"code": 4220
},
{
"name": "4291 - Taxicab Transportation",
"code": 4291
},
{
"name": "4292 - Passenger Autos for Rent with Driver",
"code": 4292
},
{
"name": "4294 - Ambulance Service",
"code": 4294
},
{
"name": "4295 - Parcel Delivery & Pickup and Delivery Service",
"code": 4295
},
{
"name": "4299 - Other Motor Vehicle Transportation",
"code": 4299
},
{
"name": "4310 - Airport",
"code": 4310
},
{
"name": "4510 - Freeway",
"code": 4510
},
{
"name": "4520 - Principle Arterial",
"code": 4520
},
{
"name": "4530 - Major Arterial",
"code": 4530
},
{
"name": "4540 - Collector",
"code": 4540
},
{
"name": "4550 - Local",
"code": 4550
},
{
"name": "4560 - Alley",
"code": 4560
},
{
"name": "4599 - Neighborhood Walking Path",
"code": 4599
},
{
"name": "4600 - Automobile Parking",
"code": 4600
},
{
"name": "4710 - Telephone Communication",
"code": 4710
},
{
"name": "4712 - Cell Tower",
"code": 4712
},
{
"name": "4730 - Radio Communication",
"code": 4730
},
{
"name": "4731 - Radio Broadcasting Station",
"code": 4731
},
{
"name": "4732 - Radio Tower",
"code": 4732
},
{
"name": "4740 - Television Communication",
"code": 4740
},
{
"name": "4741 - Television Broadcasting Station",
"code": 4741
},
{
"name": "4742 - Television Tower",
"code": 4742
},
{
"name": "4810 - Electric Utility",
"code": 4810
},
{
"name": "4812 - Electric Generation Plant",
"code": 4812
},
{
"name": "4813 - Electric Substation",
"code": 4813
},
{
"name": "4818 - Wind Farm",
"code": 4818
},
{
"name": "4820 - Gas Utility",
"code": 4820
},
{
"name": "4830 - Water Utility",
"code": 4830
},
{
"name": "4832 - Water Treatment Plant",
"code": 4832
},
{
"name": "4833 - Water Storage",
"code": 4833
},
{
"name": "4834 - Water Storage - Covered",
"code": 4834
},
{
"name": "4840 - Sewage Disposal",
"code": 4840
},
{
"name": "4841 - Sewage Treatment Plant",
"code": 4841
},
{
"name": "4874 - Storm Pond",
"code": 4874
},
{
"name": "4890 - Fiber Utility",
"code": 4890
},
{
"name": "4891 - Internet Service Provider",
"code": 4891
},
{
"name": "4920 - Transportation Services & Arrangements",
"code": 4920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 60,
"name": "TCU - Transportation, Communication & Utilites"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC WHL",
"description": "Valid standard land use code WHL values",
"codedValues": [
{
"name": "5110 - Motor Vehicles & Automotive Equipment",
"code": 5110
},
{
"name": "5120 - Drugs, Chemical, & Allied Products",
"code": 5120
},
{
"name": "5130 - Dry Goods & Apparel",
"code": 5130
},
{
"name": "5140 - Groceries & Related Products",
"code": 5140
},
{
"name": "5150 - Farm Products",
"code": 5150
},
{
"name": "5160 - Electrical Goods",
"code": 5160
},
{
"name": "5170 - Hardware, Plumbing, Heating Equipment & Supplies",
"code": 5170
},
{
"name": "5180 - Machinery, Equipment & Supplies",
"code": 5180
},
{
"name": "5190 - Miscellaneous Wholesale",
"code": 5190
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 70,
"name": "WHL - Wholesale Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RTL",
"description": "Valid standard land use code RTL values",
"codedValues": [
{
"name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies",
"code": 5200
},
{
"name": "5300 - General Merchandise",
"code": 5300
},
{
"name": "5310 - Shopping Center/Mall",
"code": 5310
},
{
"name": "5311 - Department Store",
"code": 5311
},
{
"name": "5312 - Discount Department Store",
"code": 5312
},
{
"name": "5313 - Surplus Store",
"code": 5313
},
{
"name": "5330 - Variety Store",
"code": 5330
},
{
"name": "5350 - Direct Selling Organization",
"code": 5350
},
{
"name": "5390 - Other Retail Trade - General Merchandise",
"code": 5390
},
{
"name": "5411 - Grocery Store/Supermarket",
"code": 5411
},
{
"name": "5412 - Convenience Store",
"code": 5412
},
{
"name": "5420 - Meat & Fish",
"code": 5420
},
{
"name": "5430 - Produce",
"code": 5430
},
{
"name": "5440 - Candy & Confectionery",
"code": 5440
},
{
"name": "5450 - Dairy Products",
"code": 5450
},
{
"name": "5460 - Bakeries & Donut Shops",
"code": 5460
},
{
"name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)",
"code": 5490
},
{
"name": "5510 - Motor Vehicles",
"code": 5510
},
{
"name": "5520 - Tires, Batteries & Accessories (auto parts stores)",
"code": 5520
},
{
"name": "5530 - Gas Station",
"code": 5530
},
{
"name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories",
"code": 5590
},
{
"name": "5600 - Apparel & Accessories",
"code": 5600
},
{
"name": "5710 - Furniture, Home Furnishings & Equipment",
"code": 5710
},
{
"name": "5720 - Household Appliances",
"code": 5720
},
{
"name": "5730 - Electronics",
"code": 5730
},
{
"name": "5740 - Office Equipment & Furniture",
"code": 5740
},
{
"name": "5811 - Restaurants (with or without liquor)",
"code": 5811
},
{
"name": "5812 - Short Order Sit Down",
"code": 5812
},
{
"name": "5813 - Short Order Drive-In",
"code": 5813
},
{
"name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)",
"code": 5814
},
{
"name": "5820 - Drinking Places - Alcoholic Beverages",
"code": 5820
},
{
"name": "5910 - Drug & Pharmacy",
"code": 5910
},
{
"name": "5920 - Liquor Store",
"code": 5920
},
{
"name": "5930 - Antiques & Secondhand Merchandise",
"code": 5930
},
{
"name": "5940 - Books, Stationery, Art & Hobby Supplies",
"code": 5940
},
{
"name": "5950 - Sporting Goods",
"code": 5950
},
{
"name": "5960 - Farm & Garden Supplies",
"code": 5960
},
{
"name": "5969 - Nursery Plants & Garden Supplies",
"code": 5969
},
{
"name": "5970 - Jewelry Store",
"code": 5970
},
{
"name": "5980 - Fuel & Ice",
"code": 5980
},
{
"name": "5990 - Miscellaneous Retail Trade",
"code": 5990
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 80,
"name": "RTL - Retail Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC EDU",
"description": "Valid standard land use code EDU values",
"codedValues": [
{
"name": "6811 - Kindergarten (Head Start)",
"code": 6811
},
{
"name": "6812 - Elementary",
"code": 6812
},
{
"name": "6813 - Junior High",
"code": 6813
},
{
"name": "6814 - Senior High",
"code": 6814
},
{
"name": "6818 - District Office",
"code": 6818
},
{
"name": "6821 - University or College",
"code": 6821
},
{
"name": "6831 - Vocational or Trade",
"code": 6831
},
{
"name": "6833 - Barber & Beauty School",
"code": 6833
},
{
"name": "6834 - Art, Drama & Music School",
"code": 6834
},
{
"name": "6835 - Dancing School",
"code": 6835
},
{
"name": "6836 - Driving School",
"code": 6836
},
{
"name": "6837 - Online & Correspondence School",
"code": 6837
},
{
"name": "6838 - Language School",
"code": 6838
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 90,
"name": "EDU - Educational"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SRV",
"description": "Valid standard land use code SRV values",
"codedValues": [
{
"name": "6110 - Banking & Related Functions",
"code": 6110
},
{
"name": "6120 - Credit Services",
"code": 6120
},
{
"name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services",
"code": 6130
},
{
"name": "6140 - Insurance Carriers, Agents, Brokers & Services",
"code": 6140
},
{
"name": "6150 - Real Estate & Related Services",
"code": 6150
},
{
"name": "6160 - Holding & Investment Services",
"code": 6160
},
{
"name": "6210 - Laundering & Dry Cleaning",
"code": 6210
},
{
"name": "6220 - Photographic Services",
"code": 6220
},
{
"name": "6230 - Beauty & Barber Services",
"code": 6230
},
{
"name": "6241 - Funeral Home",
"code": 6241
},
{
"name": "6242 - Cemeteries",
"code": 6242
},
{
"name": "6243 - Crematory",
"code": 6243
},
{
"name": "6250 - Apparel & Shoe Repair",
"code": 6250
},
{
"name": "6291 - Clothing Rental",
"code": 6291
},
{
"name": "6292 - Costume Rental",
"code": 6292
},
{
"name": "6295 - Tattooing",
"code": 6295
},
{
"name": "6296 - Massage Parlors",
"code": 6296
},
{
"name": "6310 - Advertising Services",
"code": 6310
},
{
"name": "6320 - Credit Reporting Services, Adjustment & Collections Services",
"code": 6320
},
{
"name": "6330 - Duplicating, Mailing & Office Services",
"code": 6330
},
{
"name": "6340 - Dwelling Cleaning, Maintenance & Building Services",
"code": 6340
},
{
"name": "6360 - Employment Services",
"code": 6360
},
{
"name": "6370 - Warehousing & Storage Services",
"code": 6370
},
{
"name": "6371 - Farming Products Warehousing",
"code": 6371
},
{
"name": "6372 - Stockyards",
"code": 6372
},
{
"name": "6390 - Business Services",
"code": 6390
},
{
"name": "6410 - Automobile Repair & Related Services",
"code": 6410
},
{
"name": "6420 - Electrical Appliance Repair & Services",
"code": 6420
},
{
"name": "6490 - Repair Shops & Related Services",
"code": 6490
},
{
"name": "6511 - Physicians Office",
"code": 6511
},
{
"name": "6512 - Dental Office",
"code": 6512
},
{
"name": "6513 - Hospital",
"code": 6513
},
{
"name": "6516 - Rest Home",
"code": 6516
},
{
"name": "6517 - Medical Clinic/Emergency Centers",
"code": 6517
},
{
"name": "6520 - Legal Services",
"code": 6520
},
{
"name": "6530 - Engineering, Architectural & Planning Services",
"code": 6530
},
{
"name": "6540 - Research Services (INL)",
"code": 6540
},
{
"name": "6590 - Other Professional Services",
"code": 6590
},
{
"name": "6600 - Contract Construction Services",
"code": 6600
},
{
"name": "6700 - Governmental Services",
"code": 6700
},
{
"name": "6710 - Executive, Legislative & Judicial Functions",
"code": 6710
},
{
"name": "6721 - Police Services",
"code": 6721
},
{
"name": "6723 - Fire Services",
"code": 6723
},
{
"name": "6724 - Civil Defense",
"code": 6724
},
{
"name": "6725 - Health Services",
"code": 6725
},
{
"name": "6730 - Postal Services (Government)",
"code": 6730
},
{
"name": "6740 - Correctional Institution",
"code": 6740
},
{
"name": "6815 - Day Care Center",
"code": 6815
},
{
"name": "6911 - Church, Synagogue & Temple",
"code": 6911
},
{
"name": "6920 - Welfare & Charitable Services",
"code": 6920
},
{
"name": "6930 - Business, Professional & Labor Organizations & Services",
"code": 6930
},
{
"name": "6940 - Social, Fraternal & Youth Organizations & Services",
"code": 6940
},
{
"name": "6950 - Political, Civic & Veterans Organizations",
"code": 6950
},
{
"name": "6960 - Organizations & Clubs",
"code": 6960
},
{
"name": "6990 - Recycling Center",
"code": 6990
},
{
"name": "6994 - Senior Citizens Center",
"code": 6994
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 100,
"name": "SRV - Services"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RTL",
"description": "Valid standard land use code RTL values",
"codedValues": [
{
"name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies",
"code": 5200
},
{
"name": "5300 - General Merchandise",
"code": 5300
},
{
"name": "5310 - Shopping Center/Mall",
"code": 5310
},
{
"name": "5311 - Department Store",
"code": 5311
},
{
"name": "5312 - Discount Department Store",
"code": 5312
},
{
"name": "5313 - Surplus Store",
"code": 5313
},
{
"name": "5330 - Variety Store",
"code": 5330
},
{
"name": "5350 - Direct Selling Organization",
"code": 5350
},
{
"name": "5390 - Other Retail Trade - General Merchandise",
"code": 5390
},
{
"name": "5411 - Grocery Store/Supermarket",
"code": 5411
},
{
"name": "5412 - Convenience Store",
"code": 5412
},
{
"name": "5420 - Meat & Fish",
"code": 5420
},
{
"name": "5430 - Produce",
"code": 5430
},
{
"name": "5440 - Candy & Confectionery",
"code": 5440
},
{
"name": "5450 - Dairy Products",
"code": 5450
},
{
"name": "5460 - Bakeries & Donut Shops",
"code": 5460
},
{
"name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)",
"code": 5490
},
{
"name": "5510 - Motor Vehicles",
"code": 5510
},
{
"name": "5520 - Tires, Batteries & Accessories (auto parts stores)",
"code": 5520
},
{
"name": "5530 - Gas Station",
"code": 5530
},
{
"name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories",
"code": 5590
},
{
"name": "5600 - Apparel & Accessories",
"code": 5600
},
{
"name": "5710 - Furniture, Home Furnishings & Equipment",
"code": 5710
},
{
"name": "5720 - Household Appliances",
"code": 5720
},
{
"name": "5730 - Electronics",
"code": 5730
},
{
"name": "5740 - Office Equipment & Furniture",
"code": 5740
},
{
"name": "5811 - Restaurants (with or without liquor)",
"code": 5811
},
{
"name": "5812 - Short Order Sit Down",
"code": 5812
},
{
"name": "5813 - Short Order Drive-In",
"code": 5813
},
{
"name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)",
"code": 5814
},
{
"name": "5820 - Drinking Places - Alcoholic Beverages",
"code": 5820
},
{
"name": "5910 - Drug & Pharmacy",
"code": 5910
},
{
"name": "5920 - Liquor Store",
"code": 5920
},
{
"name": "5930 - Antiques & Secondhand Merchandise",
"code": 5930
},
{
"name": "5940 - Books, Stationery, Art & Hobby Supplies",
"code": 5940
},
{
"name": "5950 - Sporting Goods",
"code": 5950
},
{
"name": "5960 - Farm & Garden Supplies",
"code": 5960
},
{
"name": "5969 - Nursery Plants & Garden Supplies",
"code": 5969
},
{
"name": "5970 - Jewelry Store",
"code": 5970
},
{
"name": "5980 - Fuel & Ice",
"code": 5980
},
{
"name": "5990 - Miscellaneous Retail Trade",
"code": 5990
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 110,
"name": "CBDRL - Central Business District Retail Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SRV",
"description": "Valid standard land use code SRV values",
"codedValues": [
{
"name": "6110 - Banking & Related Functions",
"code": 6110
},
{
"name": "6120 - Credit Services",
"code": 6120
},
{
"name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services",
"code": 6130
},
{
"name": "6140 - Insurance Carriers, Agents, Brokers & Services",
"code": 6140
},
{
"name": "6150 - Real Estate & Related Services",
"code": 6150
},
{
"name": "6160 - Holding & Investment Services",
"code": 6160
},
{
"name": "6210 - Laundering & Dry Cleaning",
"code": 6210
},
{
"name": "6220 - Photographic Services",
"code": 6220
},
{
"name": "6230 - Beauty & Barber Services",
"code": 6230
},
{
"name": "6241 - Funeral Home",
"code": 6241
},
{
"name": "6242 - Cemeteries",
"code": 6242
},
{
"name": "6243 - Crematory",
"code": 6243
},
{
"name": "6250 - Apparel & Shoe Repair",
"code": 6250
},
{
"name": "6291 - Clothing Rental",
"code": 6291
},
{
"name": "6292 - Costume Rental",
"code": 6292
},
{
"name": "6295 - Tattooing",
"code": 6295
},
{
"name": "6296 - Massage Parlors",
"code": 6296
},
{
"name": "6310 - Advertising Services",
"code": 6310
},
{
"name": "6320 - Credit Reporting Services, Adjustment & Collections Services",
"code": 6320
},
{
"name": "6330 - Duplicating, Mailing & Office Services",
"code": 6330
},
{
"name": "6340 - Dwelling Cleaning, Maintenance & Building Services",
"code": 6340
},
{
"name": "6360 - Employment Services",
"code": 6360
},
{
"name": "6370 - Warehousing & Storage Services",
"code": 6370
},
{
"name": "6371 - Farming Products Warehousing",
"code": 6371
},
{
"name": "6372 - Stockyards",
"code": 6372
},
{
"name": "6390 - Business Services",
"code": 6390
},
{
"name": "6410 - Automobile Repair & Related Services",
"code": 6410
},
{
"name": "6420 - Electrical Appliance Repair & Services",
"code": 6420
},
{
"name": "6490 - Repair Shops & Related Services",
"code": 6490
},
{
"name": "6511 - Physicians Office",
"code": 6511
},
{
"name": "6512 - Dental Office",
"code": 6512
},
{
"name": "6513 - Hospital",
"code": 6513
},
{
"name": "6516 - Rest Home",
"code": 6516
},
{
"name": "6517 - Medical Clinic/Emergency Centers",
"code": 6517
},
{
"name": "6520 - Legal Services",
"code": 6520
},
{
"name": "6530 - Engineering, Architectural & Planning Services",
"code": 6530
},
{
"name": "6540 - Research Services (INL)",
"code": 6540
},
{
"name": "6590 - Other Professional Services",
"code": 6590
},
{
"name": "6600 - Contract Construction Services",
"code": 6600
},
{
"name": "6700 - Governmental Services",
"code": 6700
},
{
"name": "6710 - Executive, Legislative & Judicial Functions",
"code": 6710
},
{
"name": "6721 - Police Services",
"code": 6721
},
{
"name": "6723 - Fire Services",
"code": 6723
},
{
"name": "6724 - Civil Defense",
"code": 6724
},
{
"name": "6725 - Health Services",
"code": 6725
},
{
"name": "6730 - Postal Services (Government)",
"code": 6730
},
{
"name": "6740 - Correctional Institution",
"code": 6740
},
{
"name": "6815 - Day Care Center",
"code": 6815
},
{
"name": "6911 - Church, Synagogue & Temple",
"code": 6911
},
{
"name": "6920 - Welfare & Charitable Services",
"code": 6920
},
{
"name": "6930 - Business, Professional & Labor Organizations & Services",
"code": 6930
},
{
"name": "6940 - Social, Fraternal & Youth Organizations & Services",
"code": 6940
},
{
"name": "6950 - Political, Civic & Veterans Organizations",
"code": 6950
},
{
"name": "6960 - Organizations & Clubs",
"code": 6960
},
{
"name": "6990 - Recycling Center",
"code": 6990
},
{
"name": "6994 - Senior Citizens Center",
"code": 6994
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 120,
"name": "CBDSV - Central Business District Services"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC CER",
"description": "Valid standard land use CER values",
"codedValues": [
{
"name": "7111 - Library",
"code": 7111
},
{
"name": "7112 - Museum",
"code": 7112
},
{
"name": "7113 - Art Gallery",
"code": 7113
},
{
"name": "7123 - Botanical Garden",
"code": 7123
},
{
"name": "7124 - Zoo",
"code": 7124
},
{
"name": "7191 - Historical & Monument Site",
"code": 7191
},
{
"name": "7212 - Theater",
"code": 7212
},
{
"name": "7213 - Drive-in Theater",
"code": 7213
},
{
"name": "7221 - Stadium",
"code": 7221
},
{
"name": "7222 - Arena",
"code": 7222
},
{
"name": "7223 - Race Track - Animal",
"code": 7223
},
{
"name": "7224 - Race Track - Auto",
"code": 7224
},
{
"name": "7231 - Auditorium",
"code": 7231
},
{
"name": "7232 - Exhibition Hall",
"code": 7232
},
{
"name": "7233 - Convention Center",
"code": 7233
},
{
"name": "7234 - Civic Theater",
"code": 7234
},
{
"name": "7311 - Fairgrounds",
"code": 7311
},
{
"name": "7312 - Amusement Park",
"code": 7312
},
{
"name": "7391 - Arcade",
"code": 7391
},
{
"name": "7392 - Miniature Golf",
"code": 7392
},
{
"name": "7396 - Dance Hall",
"code": 7396
},
{
"name": "7397 - Billiard",
"code": 7397
},
{
"name": "7411 - Golf Course - Public",
"code": 7411
},
{
"name": "7412 - Golf Course - Private",
"code": 7412
},
{
"name": "7413 - Tennis Court",
"code": 7413
},
{
"name": "7414 - Ice Skating",
"code": 7414
},
{
"name": "7415 - Roller Skating",
"code": 7415
},
{
"name": "7416 - Riding Academy",
"code": 7416
},
{
"name": "7417 - Bowling Alley",
"code": 7417
},
{
"name": "7421 - Playground",
"code": 7421
},
{
"name": "7423 - Athletic Field",
"code": 7423
},
{
"name": "7424 - Recreation & Community Center",
"code": 7424
},
{
"name": "7425 - Gymnasium",
"code": 7425
},
{
"name": "7426 - Baseball Field",
"code": 7426
},
{
"name": "7432 - Swimming Pool",
"code": 7432
},
{
"name": "7433 - Water Park",
"code": 7433
},
{
"name": "7442 - Boat Access Site",
"code": 7442
},
{
"name": "7443 - Sports Fishing Activities",
"code": 7443
},
{
"name": "7451 - Archery Range",
"code": 7451
},
{
"name": "7452 - Gun Range",
"code": 7452
},
{
"name": "7491 - RV Parking & Camping Area",
"code": 7491
},
{
"name": "7611 - Developed Park",
"code": 7611
},
{
"name": "7612 - Undeveloped Park",
"code": 7612
},
{
"name": "7621 - Green Belt",
"code": 7621
},
{
"name": "7691 - Landscaped Lot",
"code": 7691
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 130,
"name": "CER - Cultural, Entertainment & Recreation"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC AGL",
"description": "Valid standard land use code AGL values",
"codedValues": [
{
"name": "8100 - Agriculture",
"code": 8100
},
{
"name": "8144 - Dairy",
"code": 8144
},
{
"name": "8221 - Veterinarian",
"code": 8221
},
{
"name": "8224 - Kennel",
"code": 8224
},
{
"name": "8292 - Tree Planting, Pruning, Spraying",
"code": 8292
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 140,
"name": "AGL - Agricultural"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC MNG",
"description": "Valid standard land use code MNG values",
"codedValues": [
{
"name": "8543 - Gravel Pit",
"code": 8543
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 150,
"name": "MNG - Mining"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC VCT",
"description": "Valid standard land use code VCT values",
"codedValues": [
{
"name": "9100 - Vacant Land",
"code": 9100
},
{
"name": "9400 - Vacant Building",
"code": 9400
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 160,
"name": "VCT - Vacant"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC WTR",
"description": "Valid standard land use code WTR values",
"codedValues": [
{
"name": "9310 - Snake River",
"code": 9310
},
{
"name": "9311 - Canal/Stream",
"code": 9311
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 170,
"name": "WTR - Water Areas"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC ROW",
"description": "Valid standard land use code ROW values",
"codedValues": [
{
"name": "4500 - Highway and Street Right-of-Way",
"code": 4500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"id": 180,
"name": "ROW - Streets & Right-of-Ways"
}
],
"subtypes": [
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SFD",
"description": "Valid standard land use code SFD values",
"codedValues": [
{
"name": "1110 - Single Family Detached",
"code": 1110
},
{
"name": "1140 - Townhome/Single Family Attached (separate ownership)",
"code": 1140
},
{
"name": "1150 - Mobile Home",
"code": 1150
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 10,
"name": "SFD - Single Family Dwelling"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC MFD",
"description": "Valid standard land use code MFD values",
"codedValues": [
{
"name": "1120 - Two Units",
"code": 1120
},
{
"name": "1130 - Three or More Units",
"code": 1130
},
{
"name": "1300 - Residential Motel",
"code": 1300
},
{
"name": "1400 - Mobile Home Park",
"code": 1400
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 20,
"name": "MFD - Multi-Family Dwelling"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RSL",
"description": "Valid standard land use code RSL values",
"codedValues": [
{
"name": "1210 - Group Home",
"code": 1210
},
{
"name": "1241 - Retirement Home",
"code": 1241
},
{
"name": "1500 - Hotel/Motel",
"code": 1500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 30,
"name": "RSL - Other Residential"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC ACB",
"description": "Valid standard land use ACB values",
"codedValues": [
{
"name": "1950 - Detached Garage",
"code": 1950
},
{
"name": "1951 - Attached Garage",
"code": 1951
},
{
"name": "1952 - Covered Carport",
"code": 1952
},
{
"name": "1958 - Pool House",
"code": 1958
},
{
"name": "1960 - Shed",
"code": 1960
},
{
"name": "1970 - Deck",
"code": 1970
},
{
"name": "1971 - Pergola, Covered Deck, Patio Cover",
"code": 1971
},
{
"name": "1972 - Green House",
"code": 1972
},
{
"name": "1975 - ADA Ramp",
"code": 1975
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 40,
"name": "ACB - Accessory Building/Structure"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC I&M",
"description": "Valid standard land use code I&M values",
"codedValues": [
{
"name": "2100 - Food and Kindred Products",
"code": 2100
},
{
"name": "2200 - Textile Products",
"code": 2200
},
{
"name": "2300 - Apparel & other finished products made from fabrics, leather or similar",
"code": 2300
},
{
"name": "2400 - Lumber & Wood Products (except furniture)",
"code": 2400
},
{
"name": "2500 - Furniture & Fixtures",
"code": 2500
},
{
"name": "2600 - Paper & Allied Products",
"code": 2600
},
{
"name": "2700 - Printing, Publishing & Allied Industries",
"code": 2700
},
{
"name": "2800 - Chemicals & Allied Products",
"code": 2800
},
{
"name": "2900 - Petroleum Refining & Related Industries",
"code": 2900
},
{
"name": "3100 - Rubber & Miscellaneous Plastic Products",
"code": 3100
},
{
"name": "3200 - Stone, Clay & Glass Products",
"code": 3200
},
{
"name": "3300 - Metal Industries",
"code": 3300
},
{
"name": "3400 - Fabricated Metal Products",
"code": 3400
},
{
"name": "3500 - Professional, Scientific & Controlling Instruments; Research Instruments & Associated",
"code": 3500
},
{
"name": "3900 - Miscellaneous Manufacturing",
"code": 3900
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 50,
"name": "I&M - Industrial & Manufacturing"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC TCU",
"description": "Valid standard land use code TCU values",
"codedValues": [
{
"name": "4110 - Railroad Transportation",
"code": 4110
},
{
"name": "4210 - Bus Transportation",
"code": 4210
},
{
"name": "4220 - Motor Freight Transportation",
"code": 4220
},
{
"name": "4291 - Taxicab Transportation",
"code": 4291
},
{
"name": "4292 - Passenger Autos for Rent with Driver",
"code": 4292
},
{
"name": "4294 - Ambulance Service",
"code": 4294
},
{
"name": "4295 - Parcel Delivery & Pickup and Delivery Service",
"code": 4295
},
{
"name": "4299 - Other Motor Vehicle Transportation",
"code": 4299
},
{
"name": "4310 - Airport",
"code": 4310
},
{
"name": "4510 - Freeway",
"code": 4510
},
{
"name": "4520 - Principle Arterial",
"code": 4520
},
{
"name": "4530 - Major Arterial",
"code": 4530
},
{
"name": "4540 - Collector",
"code": 4540
},
{
"name": "4550 - Local",
"code": 4550
},
{
"name": "4560 - Alley",
"code": 4560
},
{
"name": "4599 - Neighborhood Walking Path",
"code": 4599
},
{
"name": "4600 - Automobile Parking",
"code": 4600
},
{
"name": "4710 - Telephone Communication",
"code": 4710
},
{
"name": "4712 - Cell Tower",
"code": 4712
},
{
"name": "4730 - Radio Communication",
"code": 4730
},
{
"name": "4731 - Radio Broadcasting Station",
"code": 4731
},
{
"name": "4732 - Radio Tower",
"code": 4732
},
{
"name": "4740 - Television Communication",
"code": 4740
},
{
"name": "4741 - Television Broadcasting Station",
"code": 4741
},
{
"name": "4742 - Television Tower",
"code": 4742
},
{
"name": "4810 - Electric Utility",
"code": 4810
},
{
"name": "4812 - Electric Generation Plant",
"code": 4812
},
{
"name": "4813 - Electric Substation",
"code": 4813
},
{
"name": "4818 - Wind Farm",
"code": 4818
},
{
"name": "4820 - Gas Utility",
"code": 4820
},
{
"name": "4830 - Water Utility",
"code": 4830
},
{
"name": "4832 - Water Treatment Plant",
"code": 4832
},
{
"name": "4833 - Water Storage",
"code": 4833
},
{
"name": "4834 - Water Storage - Covered",
"code": 4834
},
{
"name": "4840 - Sewage Disposal",
"code": 4840
},
{
"name": "4841 - Sewage Treatment Plant",
"code": 4841
},
{
"name": "4874 - Storm Pond",
"code": 4874
},
{
"name": "4890 - Fiber Utility",
"code": 4890
},
{
"name": "4891 - Internet Service Provider",
"code": 4891
},
{
"name": "4920 - Transportation Services & Arrangements",
"code": 4920
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 60,
"name": "TCU - Transportation, Communication & Utilites"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC WHL",
"description": "Valid standard land use code WHL values",
"codedValues": [
{
"name": "5110 - Motor Vehicles & Automotive Equipment",
"code": 5110
},
{
"name": "5120 - Drugs, Chemical, & Allied Products",
"code": 5120
},
{
"name": "5130 - Dry Goods & Apparel",
"code": 5130
},
{
"name": "5140 - Groceries & Related Products",
"code": 5140
},
{
"name": "5150 - Farm Products",
"code": 5150
},
{
"name": "5160 - Electrical Goods",
"code": 5160
},
{
"name": "5170 - Hardware, Plumbing, Heating Equipment & Supplies",
"code": 5170
},
{
"name": "5180 - Machinery, Equipment & Supplies",
"code": 5180
},
{
"name": "5190 - Miscellaneous Wholesale",
"code": 5190
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 70,
"name": "WHL - Wholesale Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RTL",
"description": "Valid standard land use code RTL values",
"codedValues": [
{
"name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies",
"code": 5200
},
{
"name": "5300 - General Merchandise",
"code": 5300
},
{
"name": "5310 - Shopping Center/Mall",
"code": 5310
},
{
"name": "5311 - Department Store",
"code": 5311
},
{
"name": "5312 - Discount Department Store",
"code": 5312
},
{
"name": "5313 - Surplus Store",
"code": 5313
},
{
"name": "5330 - Variety Store",
"code": 5330
},
{
"name": "5350 - Direct Selling Organization",
"code": 5350
},
{
"name": "5390 - Other Retail Trade - General Merchandise",
"code": 5390
},
{
"name": "5411 - Grocery Store/Supermarket",
"code": 5411
},
{
"name": "5412 - Convenience Store",
"code": 5412
},
{
"name": "5420 - Meat & Fish",
"code": 5420
},
{
"name": "5430 - Produce",
"code": 5430
},
{
"name": "5440 - Candy & Confectionery",
"code": 5440
},
{
"name": "5450 - Dairy Products",
"code": 5450
},
{
"name": "5460 - Bakeries & Donut Shops",
"code": 5460
},
{
"name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)",
"code": 5490
},
{
"name": "5510 - Motor Vehicles",
"code": 5510
},
{
"name": "5520 - Tires, Batteries & Accessories (auto parts stores)",
"code": 5520
},
{
"name": "5530 - Gas Station",
"code": 5530
},
{
"name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories",
"code": 5590
},
{
"name": "5600 - Apparel & Accessories",
"code": 5600
},
{
"name": "5710 - Furniture, Home Furnishings & Equipment",
"code": 5710
},
{
"name": "5720 - Household Appliances",
"code": 5720
},
{
"name": "5730 - Electronics",
"code": 5730
},
{
"name": "5740 - Office Equipment & Furniture",
"code": 5740
},
{
"name": "5811 - Restaurants (with or without liquor)",
"code": 5811
},
{
"name": "5812 - Short Order Sit Down",
"code": 5812
},
{
"name": "5813 - Short Order Drive-In",
"code": 5813
},
{
"name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)",
"code": 5814
},
{
"name": "5820 - Drinking Places - Alcoholic Beverages",
"code": 5820
},
{
"name": "5910 - Drug & Pharmacy",
"code": 5910
},
{
"name": "5920 - Liquor Store",
"code": 5920
},
{
"name": "5930 - Antiques & Secondhand Merchandise",
"code": 5930
},
{
"name": "5940 - Books, Stationery, Art & Hobby Supplies",
"code": 5940
},
{
"name": "5950 - Sporting Goods",
"code": 5950
},
{
"name": "5960 - Farm & Garden Supplies",
"code": 5960
},
{
"name": "5969 - Nursery Plants & Garden Supplies",
"code": 5969
},
{
"name": "5970 - Jewelry Store",
"code": 5970
},
{
"name": "5980 - Fuel & Ice",
"code": 5980
},
{
"name": "5990 - Miscellaneous Retail Trade",
"code": 5990
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 80,
"name": "RTL - Retail Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC EDU",
"description": "Valid standard land use code EDU values",
"codedValues": [
{
"name": "6811 - Kindergarten (Head Start)",
"code": 6811
},
{
"name": "6812 - Elementary",
"code": 6812
},
{
"name": "6813 - Junior High",
"code": 6813
},
{
"name": "6814 - Senior High",
"code": 6814
},
{
"name": "6818 - District Office",
"code": 6818
},
{
"name": "6821 - University or College",
"code": 6821
},
{
"name": "6831 - Vocational or Trade",
"code": 6831
},
{
"name": "6833 - Barber & Beauty School",
"code": 6833
},
{
"name": "6834 - Art, Drama & Music School",
"code": 6834
},
{
"name": "6835 - Dancing School",
"code": 6835
},
{
"name": "6836 - Driving School",
"code": 6836
},
{
"name": "6837 - Online & Correspondence School",
"code": 6837
},
{
"name": "6838 - Language School",
"code": 6838
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 90,
"name": "EDU - Educational"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SRV",
"description": "Valid standard land use code SRV values",
"codedValues": [
{
"name": "6110 - Banking & Related Functions",
"code": 6110
},
{
"name": "6120 - Credit Services",
"code": 6120
},
{
"name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services",
"code": 6130
},
{
"name": "6140 - Insurance Carriers, Agents, Brokers & Services",
"code": 6140
},
{
"name": "6150 - Real Estate & Related Services",
"code": 6150
},
{
"name": "6160 - Holding & Investment Services",
"code": 6160
},
{
"name": "6210 - Laundering & Dry Cleaning",
"code": 6210
},
{
"name": "6220 - Photographic Services",
"code": 6220
},
{
"name": "6230 - Beauty & Barber Services",
"code": 6230
},
{
"name": "6241 - Funeral Home",
"code": 6241
},
{
"name": "6242 - Cemeteries",
"code": 6242
},
{
"name": "6243 - Crematory",
"code": 6243
},
{
"name": "6250 - Apparel & Shoe Repair",
"code": 6250
},
{
"name": "6291 - Clothing Rental",
"code": 6291
},
{
"name": "6292 - Costume Rental",
"code": 6292
},
{
"name": "6295 - Tattooing",
"code": 6295
},
{
"name": "6296 - Massage Parlors",
"code": 6296
},
{
"name": "6310 - Advertising Services",
"code": 6310
},
{
"name": "6320 - Credit Reporting Services, Adjustment & Collections Services",
"code": 6320
},
{
"name": "6330 - Duplicating, Mailing & Office Services",
"code": 6330
},
{
"name": "6340 - Dwelling Cleaning, Maintenance & Building Services",
"code": 6340
},
{
"name": "6360 - Employment Services",
"code": 6360
},
{
"name": "6370 - Warehousing & Storage Services",
"code": 6370
},
{
"name": "6371 - Farming Products Warehousing",
"code": 6371
},
{
"name": "6372 - Stockyards",
"code": 6372
},
{
"name": "6390 - Business Services",
"code": 6390
},
{
"name": "6410 - Automobile Repair & Related Services",
"code": 6410
},
{
"name": "6420 - Electrical Appliance Repair & Services",
"code": 6420
},
{
"name": "6490 - Repair Shops & Related Services",
"code": 6490
},
{
"name": "6511 - Physicians Office",
"code": 6511
},
{
"name": "6512 - Dental Office",
"code": 6512
},
{
"name": "6513 - Hospital",
"code": 6513
},
{
"name": "6516 - Rest Home",
"code": 6516
},
{
"name": "6517 - Medical Clinic/Emergency Centers",
"code": 6517
},
{
"name": "6520 - Legal Services",
"code": 6520
},
{
"name": "6530 - Engineering, Architectural & Planning Services",
"code": 6530
},
{
"name": "6540 - Research Services (INL)",
"code": 6540
},
{
"name": "6590 - Other Professional Services",
"code": 6590
},
{
"name": "6600 - Contract Construction Services",
"code": 6600
},
{
"name": "6700 - Governmental Services",
"code": 6700
},
{
"name": "6710 - Executive, Legislative & Judicial Functions",
"code": 6710
},
{
"name": "6721 - Police Services",
"code": 6721
},
{
"name": "6723 - Fire Services",
"code": 6723
},
{
"name": "6724 - Civil Defense",
"code": 6724
},
{
"name": "6725 - Health Services",
"code": 6725
},
{
"name": "6730 - Postal Services (Government)",
"code": 6730
},
{
"name": "6740 - Correctional Institution",
"code": 6740
},
{
"name": "6815 - Day Care Center",
"code": 6815
},
{
"name": "6911 - Church, Synagogue & Temple",
"code": 6911
},
{
"name": "6920 - Welfare & Charitable Services",
"code": 6920
},
{
"name": "6930 - Business, Professional & Labor Organizations & Services",
"code": 6930
},
{
"name": "6940 - Social, Fraternal & Youth Organizations & Services",
"code": 6940
},
{
"name": "6950 - Political, Civic & Veterans Organizations",
"code": 6950
},
{
"name": "6960 - Organizations & Clubs",
"code": 6960
},
{
"name": "6990 - Recycling Center",
"code": 6990
},
{
"name": "6994 - Senior Citizens Center",
"code": 6994
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 100,
"name": "SRV - Services"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC RTL",
"description": "Valid standard land use code RTL values",
"codedValues": [
{
"name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies",
"code": 5200
},
{
"name": "5300 - General Merchandise",
"code": 5300
},
{
"name": "5310 - Shopping Center/Mall",
"code": 5310
},
{
"name": "5311 - Department Store",
"code": 5311
},
{
"name": "5312 - Discount Department Store",
"code": 5312
},
{
"name": "5313 - Surplus Store",
"code": 5313
},
{
"name": "5330 - Variety Store",
"code": 5330
},
{
"name": "5350 - Direct Selling Organization",
"code": 5350
},
{
"name": "5390 - Other Retail Trade - General Merchandise",
"code": 5390
},
{
"name": "5411 - Grocery Store/Supermarket",
"code": 5411
},
{
"name": "5412 - Convenience Store",
"code": 5412
},
{
"name": "5420 - Meat & Fish",
"code": 5420
},
{
"name": "5430 - Produce",
"code": 5430
},
{
"name": "5440 - Candy & Confectionery",
"code": 5440
},
{
"name": "5450 - Dairy Products",
"code": 5450
},
{
"name": "5460 - Bakeries & Donut Shops",
"code": 5460
},
{
"name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)",
"code": 5490
},
{
"name": "5510 - Motor Vehicles",
"code": 5510
},
{
"name": "5520 - Tires, Batteries & Accessories (auto parts stores)",
"code": 5520
},
{
"name": "5530 - Gas Station",
"code": 5530
},
{
"name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories",
"code": 5590
},
{
"name": "5600 - Apparel & Accessories",
"code": 5600
},
{
"name": "5710 - Furniture, Home Furnishings & Equipment",
"code": 5710
},
{
"name": "5720 - Household Appliances",
"code": 5720
},
{
"name": "5730 - Electronics",
"code": 5730
},
{
"name": "5740 - Office Equipment & Furniture",
"code": 5740
},
{
"name": "5811 - Restaurants (with or without liquor)",
"code": 5811
},
{
"name": "5812 - Short Order Sit Down",
"code": 5812
},
{
"name": "5813 - Short Order Drive-In",
"code": 5813
},
{
"name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)",
"code": 5814
},
{
"name": "5820 - Drinking Places - Alcoholic Beverages",
"code": 5820
},
{
"name": "5910 - Drug & Pharmacy",
"code": 5910
},
{
"name": "5920 - Liquor Store",
"code": 5920
},
{
"name": "5930 - Antiques & Secondhand Merchandise",
"code": 5930
},
{
"name": "5940 - Books, Stationery, Art & Hobby Supplies",
"code": 5940
},
{
"name": "5950 - Sporting Goods",
"code": 5950
},
{
"name": "5960 - Farm & Garden Supplies",
"code": 5960
},
{
"name": "5969 - Nursery Plants & Garden Supplies",
"code": 5969
},
{
"name": "5970 - Jewelry Store",
"code": 5970
},
{
"name": "5980 - Fuel & Ice",
"code": 5980
},
{
"name": "5990 - Miscellaneous Retail Trade",
"code": 5990
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 110,
"name": "CBDRL - Central Business District Retail Trade"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC SRV",
"description": "Valid standard land use code SRV values",
"codedValues": [
{
"name": "6110 - Banking & Related Functions",
"code": 6110
},
{
"name": "6120 - Credit Services",
"code": 6120
},
{
"name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services",
"code": 6130
},
{
"name": "6140 - Insurance Carriers, Agents, Brokers & Services",
"code": 6140
},
{
"name": "6150 - Real Estate & Related Services",
"code": 6150
},
{
"name": "6160 - Holding & Investment Services",
"code": 6160
},
{
"name": "6210 - Laundering & Dry Cleaning",
"code": 6210
},
{
"name": "6220 - Photographic Services",
"code": 6220
},
{
"name": "6230 - Beauty & Barber Services",
"code": 6230
},
{
"name": "6241 - Funeral Home",
"code": 6241
},
{
"name": "6242 - Cemeteries",
"code": 6242
},
{
"name": "6243 - Crematory",
"code": 6243
},
{
"name": "6250 - Apparel & Shoe Repair",
"code": 6250
},
{
"name": "6291 - Clothing Rental",
"code": 6291
},
{
"name": "6292 - Costume Rental",
"code": 6292
},
{
"name": "6295 - Tattooing",
"code": 6295
},
{
"name": "6296 - Massage Parlors",
"code": 6296
},
{
"name": "6310 - Advertising Services",
"code": 6310
},
{
"name": "6320 - Credit Reporting Services, Adjustment & Collections Services",
"code": 6320
},
{
"name": "6330 - Duplicating, Mailing & Office Services",
"code": 6330
},
{
"name": "6340 - Dwelling Cleaning, Maintenance & Building Services",
"code": 6340
},
{
"name": "6360 - Employment Services",
"code": 6360
},
{
"name": "6370 - Warehousing & Storage Services",
"code": 6370
},
{
"name": "6371 - Farming Products Warehousing",
"code": 6371
},
{
"name": "6372 - Stockyards",
"code": 6372
},
{
"name": "6390 - Business Services",
"code": 6390
},
{
"name": "6410 - Automobile Repair & Related Services",
"code": 6410
},
{
"name": "6420 - Electrical Appliance Repair & Services",
"code": 6420
},
{
"name": "6490 - Repair Shops & Related Services",
"code": 6490
},
{
"name": "6511 - Physicians Office",
"code": 6511
},
{
"name": "6512 - Dental Office",
"code": 6512
},
{
"name": "6513 - Hospital",
"code": 6513
},
{
"name": "6516 - Rest Home",
"code": 6516
},
{
"name": "6517 - Medical Clinic/Emergency Centers",
"code": 6517
},
{
"name": "6520 - Legal Services",
"code": 6520
},
{
"name": "6530 - Engineering, Architectural & Planning Services",
"code": 6530
},
{
"name": "6540 - Research Services (INL)",
"code": 6540
},
{
"name": "6590 - Other Professional Services",
"code": 6590
},
{
"name": "6600 - Contract Construction Services",
"code": 6600
},
{
"name": "6700 - Governmental Services",
"code": 6700
},
{
"name": "6710 - Executive, Legislative & Judicial Functions",
"code": 6710
},
{
"name": "6721 - Police Services",
"code": 6721
},
{
"name": "6723 - Fire Services",
"code": 6723
},
{
"name": "6724 - Civil Defense",
"code": 6724
},
{
"name": "6725 - Health Services",
"code": 6725
},
{
"name": "6730 - Postal Services (Government)",
"code": 6730
},
{
"name": "6740 - Correctional Institution",
"code": 6740
},
{
"name": "6815 - Day Care Center",
"code": 6815
},
{
"name": "6911 - Church, Synagogue & Temple",
"code": 6911
},
{
"name": "6920 - Welfare & Charitable Services",
"code": 6920
},
{
"name": "6930 - Business, Professional & Labor Organizations & Services",
"code": 6930
},
{
"name": "6940 - Social, Fraternal & Youth Organizations & Services",
"code": 6940
},
{
"name": "6950 - Political, Civic & Veterans Organizations",
"code": 6950
},
{
"name": "6960 - Organizations & Clubs",
"code": 6960
},
{
"name": "6990 - Recycling Center",
"code": 6990
},
{
"name": "6994 - Senior Citizens Center",
"code": 6994
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 120,
"name": "CBDSV - Central Business District Services"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC CER",
"description": "Valid standard land use CER values",
"codedValues": [
{
"name": "7111 - Library",
"code": 7111
},
{
"name": "7112 - Museum",
"code": 7112
},
{
"name": "7113 - Art Gallery",
"code": 7113
},
{
"name": "7123 - Botanical Garden",
"code": 7123
},
{
"name": "7124 - Zoo",
"code": 7124
},
{
"name": "7191 - Historical & Monument Site",
"code": 7191
},
{
"name": "7212 - Theater",
"code": 7212
},
{
"name": "7213 - Drive-in Theater",
"code": 7213
},
{
"name": "7221 - Stadium",
"code": 7221
},
{
"name": "7222 - Arena",
"code": 7222
},
{
"name": "7223 - Race Track - Animal",
"code": 7223
},
{
"name": "7224 - Race Track - Auto",
"code": 7224
},
{
"name": "7231 - Auditorium",
"code": 7231
},
{
"name": "7232 - Exhibition Hall",
"code": 7232
},
{
"name": "7233 - Convention Center",
"code": 7233
},
{
"name": "7234 - Civic Theater",
"code": 7234
},
{
"name": "7311 - Fairgrounds",
"code": 7311
},
{
"name": "7312 - Amusement Park",
"code": 7312
},
{
"name": "7391 - Arcade",
"code": 7391
},
{
"name": "7392 - Miniature Golf",
"code": 7392
},
{
"name": "7396 - Dance Hall",
"code": 7396
},
{
"name": "7397 - Billiard",
"code": 7397
},
{
"name": "7411 - Golf Course - Public",
"code": 7411
},
{
"name": "7412 - Golf Course - Private",
"code": 7412
},
{
"name": "7413 - Tennis Court",
"code": 7413
},
{
"name": "7414 - Ice Skating",
"code": 7414
},
{
"name": "7415 - Roller Skating",
"code": 7415
},
{
"name": "7416 - Riding Academy",
"code": 7416
},
{
"name": "7417 - Bowling Alley",
"code": 7417
},
{
"name": "7421 - Playground",
"code": 7421
},
{
"name": "7423 - Athletic Field",
"code": 7423
},
{
"name": "7424 - Recreation & Community Center",
"code": 7424
},
{
"name": "7425 - Gymnasium",
"code": 7425
},
{
"name": "7426 - Baseball Field",
"code": 7426
},
{
"name": "7432 - Swimming Pool",
"code": 7432
},
{
"name": "7433 - Water Park",
"code": 7433
},
{
"name": "7442 - Boat Access Site",
"code": 7442
},
{
"name": "7443 - Sports Fishing Activities",
"code": 7443
},
{
"name": "7451 - Archery Range",
"code": 7451
},
{
"name": "7452 - Gun Range",
"code": 7452
},
{
"name": "7491 - RV Parking & Camping Area",
"code": 7491
},
{
"name": "7611 - Developed Park",
"code": 7611
},
{
"name": "7612 - Undeveloped Park",
"code": 7612
},
{
"name": "7621 - Green Belt",
"code": 7621
},
{
"name": "7691 - Landscaped Lot",
"code": 7691
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 130,
"name": "CER - Cultural, Entertainment & Recreation"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC AGL",
"description": "Valid standard land use code AGL values",
"codedValues": [
{
"name": "8100 - Agriculture",
"code": 8100
},
{
"name": "8144 - Dairy",
"code": 8144
},
{
"name": "8221 - Veterinarian",
"code": 8221
},
{
"name": "8224 - Kennel",
"code": 8224
},
{
"name": "8292 - Tree Planting, Pruning, Spraying",
"code": 8292
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 140,
"name": "AGL - Agricultural"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC MNG",
"description": "Valid standard land use code MNG values",
"codedValues": [
{
"name": "8543 - Gravel Pit",
"code": 8543
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 150,
"name": "MNG - Mining"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC VCT",
"description": "Valid standard land use code VCT values",
"codedValues": [
{
"name": "9100 - Vacant Land",
"code": 9100
},
{
"name": "9400 - Vacant Building",
"code": 9400
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 160,
"name": "VCT - Vacant"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC WTR",
"description": "Valid standard land use code WTR values",
"codedValues": [
{
"name": "9310 - Snake River",
"code": 9310
},
{
"name": "9311 - Canal/Stream",
"code": 9311
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 170,
"name": "WTR - Water Areas"
},
{
"domains": {
"StandardLandUseCode": {
"type": "codedValue",
"name": "WS3_SLUC ROW",
"description": "Valid standard land use code ROW values",
"codedValues": [
{
"name": "4500 - Highway and Street Right-of-Way",
"code": 4500
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
"defaultValues": {
"StandardLandUseType": null,
"StandardLandUseCode": null,
"Comments": null,
"CreateUser": null,
"CreateDate": null,
"EditUser": null,
"EditDate": null,
"GlobalID": null
},
"code": 180,
"name": "ROW - Streets & Right-of-Ways"
}
],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 900,
"name": "Form Based Code",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 910,
"name": "Form Based District"
},
{
"id": 920,
"name": "Form Based Subdistrict"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 687888.7329999991,
"ymin": 662118.0555000007,
"xmax": 697048.8330000006,
"ymax": 672455.1110000014,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 910,
"name": "Form Based District",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 900,
"name": "Form Based Code"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "DistrictName",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSVertical",
"color": [
255,
0,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 2
}
},
"value": "Downtown",
"label": "Downtown"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
230,
0,
0,
255
],
"width": 2
}
},
"value": "South Downtown",
"label": "South Downtown"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSBackwardDiagonal",
"color": [
255,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
255,
255,
0,
255
],
"width": 4
}
},
"value": "Northgate 1st St",
"label": "Northgate 1st St"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 687888.7329999991,
"ymin": 662118.0555000007,
"xmax": 697048.8330000006,
"ymax": 672455.1110000014,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "DistrictName",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "DistrictName",
"type": "esriFieldTypeString",
"alias": "District Name",
"length": 100,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Form Based District Name",
"description": "Valid planning form based district name values",
"codedValues": [
{
"name": "Downtown",
"code": "Downtown"
},
{
"name": "South Downtown",
"code": "South Downtown"
},
{
"name": "Northgate 1st St",
"code": "Northgate 1st St"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_230",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S193_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 920,
"name": "Form Based Subdistrict",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 900,
"name": "Form Based Code"
},
"subLayers": [],
"minScale": 60000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "SubdistrictName",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
230,
0,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Historic Core",
"label": "Historic Core"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
170,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Core A",
"label": "Core A"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
112,
168,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Edge A",
"label": "Edge A"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
112,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Edge B",
"label": "Edge B"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
235,
190,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "General A",
"label": "General A"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
178,
178,
178,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Edge C",
"label": "Edge C"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
112,
168,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "River Edge",
"label": "River Edge"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
223,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Warehouse District",
"label": "Warehouse District"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
223,
115,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Business Core",
"label": "Business Core"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Historic Residential",
"label": "Historic Residential"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
112,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "Commercial Edge",
"label": "Commercial Edge"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 50,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 688151.5150000006,
"ymin": 662316.814000003,
"xmax": 691323.3040000014,
"ymax": 667839.310999997,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "SubdistrictName",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "DistrictName",
"type": "esriFieldTypeString",
"alias": "DistrictName",
"length": 100,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Form Based District Name",
"description": "Valid planning form based district name values",
"codedValues": [
{
"name": "Downtown",
"code": "Downtown"
},
{
"name": "South Downtown",
"code": "South Downtown"
},
{
"name": "Northgate 1st St",
"code": "Northgate 1st St"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SubdistrictName",
"type": "esriFieldTypeString",
"alias": "Subdistrict Name",
"length": 100,
"domain": {
"type": "codedValue",
"name": "WS3_PLN Form Based Subdistrict Name",
"description": "Valid planning form based subdistrict name values",
"codedValues": [
{
"name": "Business Core",
"code": "Business Core"
},
{
"name": "Commercial Edge",
"code": "Commercial Edge"
},
{
"name": "Core A",
"code": "Core A"
},
{
"name": "Downtown",
"code": "Downtown"
},
{
"name": "Edge A",
"code": "Edge A"
},
{
"name": "Edge B",
"code": "Edge B"
},
{
"name": "Edge C",
"code": "Edge C"
},
{
"name": "General A",
"code": "General A"
},
{
"name": "Historic Core",
"code": "Historic Core"
},
{
"name": "Historic Residential",
"code": "Historic Residential"
},
{
"name": "River Edge",
"code": "River Edge"
},
{
"name": "Warehouse District",
"code": "Warehouse District"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {},
"indexes": [
{
"name": "UUID_231",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771076604000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 970,
"name": "Annexation",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 980,
"name": "Idaho Falls Annexation"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 673765.1570000015,
"ymin": 643478.9935000017,
"xmax": 707353.4065000005,
"ymax": 689855.1550000012,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 980,
"name": "Idaho Falls Annexation",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 970,
"name": "Annexation"
},
"subLayers": [],
"minScale": 120000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSDiagonalCross",
"color": [
0,
255,
197,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
255,
197,
255
],
"width": 4
}
}
},
"scaleSymbols": true,
"transparency": 50,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 673765.1570000015,
"ymin": 643478.9935000017,
"xmax": 707353.4065000005,
"ymax": 689855.1550000012,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": true,
"attachmentProperties": [
{
"name": "id",
"fieldName": "ATTACHMENTID",
"isEnabled": true
},
{
"name": "globalid",
"fieldName": "GLOBALID",
"isEnabled": true
},
{
"name": "keywords",
"fieldName": "KEYWORDS",
"isEnabled": false
},
{
"name": "name",
"fieldName": "ATT_NAME",
"isEnabled": true
},
{
"name": "contentType",
"fieldName": "CONTENT_TYPE",
"isEnabled": true
},
{
"name": "size",
"fieldName": "DATA_SIZE",
"isEnabled": true
},
{
"name": "exifInfo",
"fieldName": "EXIFINFO",
"isEnabled": false
}
],
"attachmentFields": [
{
"name": "ATTACHMENTID",
"type": "esriFieldTypeOID",
"alias": "ATTACHMENTID",
"editable": false,
"nullable": false,
"length": 4,
"domain": null
},
{
"name": "GLOBALID",
"type": "esriFieldTypeGlobalID",
"alias": "GLOBALID",
"editable": false,
"nullable": false,
"length": 38,
"domain": null
},
{
"name": "ATT_NAME",
"type": "esriFieldTypeString",
"alias": "ATT_NAME",
"editable": true,
"nullable": false,
"length": 250,
"domain": null
},
{
"name": "CONTENT_TYPE",
"type": "esriFieldTypeString",
"alias": "CONTENT_TYPE",
"editable": true,
"nullable": false,
"length": 150,
"domain": null
},
{
"name": "DATA_SIZE",
"type": "esriFieldTypeInteger",
"alias": "DATA_SIZE",
"editable": true,
"nullable": false,
"length": 4,
"domain": null
}
],
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayFieldExpressionInfo": {
"expression": "\"Annexation - \" + $feature.OrdinanceNumber",
"title": "DisplayField"
},
"displayField": "Type",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 25,
"domain": {
"type": "codedValue",
"name": "WS3_CTL Annexation Type",
"description": "Valid city limit annexation type values",
"codedValues": [
{
"name": "Annexation",
"code": "Annexation"
},
{
"name": "Deannexation",
"code": "Deannexation"
},
{
"name": "Repeal",
"code": "Repeal"
},
{
"name": "Affidavit of Correction",
"code": "Affidavit of Correction"
},
{
"name": "Gap",
"code": "Gap"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDefaultValue"
}
},
{
"name": "Description",
"type": "esriFieldTypeString",
"alias": "Description",
"length": 100,
"domain": null
},
{
"name": "OrdinanceNumber",
"type": "esriFieldTypeString",
"alias": "Ordinance #",
"length": 25,
"domain": null
},
{
"name": "OrdinanceDate",
"type": "esriFieldTypeDate",
"alias": "Ordinance Date",
"length": 8,
"domain": null
},
{
"name": "Acres",
"type": "esriFieldTypeDouble",
"alias": "Acres",
"domain": null
},
{
"name": "RecordNumber",
"type": "esriFieldTypeString",
"alias": "Record #",
"length": 30,
"domain": null
},
{
"name": "RecordDate",
"type": "esriFieldTypeDate",
"alias": "Record Date",
"length": 8,
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "S78_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAttachments": true,
"supportsQueryAttachmentsWithReturnUrl": true,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075859000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1000,
"name": "Connecting our Community 2021",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 1010,
"name": "Spot Improvement Recommendation 2021"
},
{
"id": 1020,
"name": "Linear Facility Recommendation 2021"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 672864.8209999986,
"ymin": 638583.5289999992,
"xmax": 726895.6295000017,
"ymax": 714388.2959999964,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1010,
"name": "Spot Improvement Recommendation 2021",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPoint",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1000,
"name": "Connecting our Community 2021"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Type",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSMS",
"style": "esriSMSCircle",
"color": [
56,
168,
0,
255
],
"size": 10,
"angle": 0,
"xoffset": 0,
"yoffset": 0,
"outline": {
"color": [
0,
0,
0,
255
],
"width": 0.6
}
},
"value": "At Grade Spot Improvement",
"label": "At Grade Spot Improvement"
},
{
"symbol": {
"type": "esriSMS",
"style": "esriSMSCircle",
"color": [
0,
255,
197,
255
],
"size": 10,
"angle": 0,
"xoffset": 0,
"yoffset": 0,
"outline": {
"color": [
0,
0,
0,
255
],
"width": 0.6
}
},
"value": "Bridge or Underpass/Tunnel",
"label": "Bridge or Underpass/Tunnel"
},
{
"symbol": {
"type": "esriSMS",
"style": "esriSMSCircle",
"color": [
137,
112,
68,
255
],
"size": 10,
"angle": 0,
"xoffset": 0,
"yoffset": 0,
"outline": {
"color": [
0,
0,
0,
255
],
"width": 0.6
}
},
"value": "Signal Spot Improvement",
"label": "Signal Spot Improvement"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 674219.306499999,
"ymin": 646000.5174999982,
"xmax": 718873.1524999999,
"ymax": 701530.5694999993,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 100,
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 50,
"domain": {
"type": "codedValue",
"name": "WS3_COC Spot Improvements Type",
"description": "Valid connecting our community spot improvements type values",
"codedValues": [
{
"name": "At Grade Spot Improvement",
"code": "At Grade Spot Improvement"
},
{
"name": "Bridge or Underpass/Tunnel",
"code": "Bridge or Underpass/Tunnel"
},
{
"name": "Signal Spot Improvement",
"code": "Signal Spot Improvement"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_111",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S84_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075911000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1020,
"name": "Linear Facility Recommendation 2021",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1000,
"name": "Connecting our Community 2021"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Type",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
112,
255,
255
],
"width": 3
},
"value": "Shared Use Path",
"label": "Shared Use Path"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
0,
0,
255
],
"width": 3
},
"value": "Bike Lane",
"label": "Bike Lane"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
197,
0,
255,
255
],
"width": 3
},
"value": "Buffered Bike Lane",
"label": "Buffered Bike Lane"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
85,
255,
0,
255
],
"width": 3
},
"value": "Signed Bike Route",
"label": "Signed Bike Route"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
170,
0,
255
],
"width": 3
},
"value": "Sidewalk",
"label": "Sidewalk"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
255,
255,
0,
255
],
"width": 3
},
"value": "Proposed Addition",
"label": "Proposed Addition"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
197,
0,
255,
255
],
"width": 3
},
"value": "Proposed Buffered Bike Lane",
"label": "Proposed Buffered Bike Lane"
},
{
"symbol": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
0,
112,
255,
255
],
"width": 3
},
"value": "Proposed Shared Use Path",
"label": "Proposed Shared Use Path"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 672864.8209999986,
"ymin": 638583.5289999992,
"xmax": 726895.6295000017,
"ymax": 714388.2959999964,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Name",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "OBJECTID",
"domain": null
},
{
"name": "Name",
"type": "esriFieldTypeString",
"alias": "Name",
"length": 100,
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 30,
"domain": {
"type": "codedValue",
"name": "WS3_COC Linear Facilities Type",
"description": "Valid connecting our community linear facilities type values",
"codedValues": [
{
"name": "Shared Use Path",
"code": "Shared Use Path"
},
{
"name": "Buffered Bike Lane",
"code": "Buffered Bike Lane"
},
{
"name": "Bike Lane",
"code": "Bike Lane"
},
{
"name": "Signed Bike Route",
"code": "Signed Bike Route"
},
{
"name": "Sidewalk",
"code": "Sidewalk"
},
{
"name": "Proposed Buffered Bike Lane",
"code": "Proposed Buffered Bike Lane"
},
{
"name": "Proposed Shared Use Path",
"code": "Proposed Shared Use Path"
},
{
"name": "Proposed Addition",
"code": "Proposed Addition"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "SHAPE",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "SHAPE"
},
"indexes": [
{
"name": "UUID_110",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S83_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075911000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1100,
"name": "Floodplain",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 1110,
"name": "Floodplain Buffer"
},
{
"id": 1120,
"name": "River Buffer"
},
{
"id": 1130,
"name": "Floodplain"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 667190.75,
"ymin": 638359.8125,
"xmax": 726218.625,
"ymax": 714976.5,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1110,
"name": "Floodplain Buffer",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1100,
"name": "Floodplain"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
130,
130,
130,
0
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
0,
112,
255,
255
],
"width": 1
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 674102.2745000012,
"ymin": 640894.6269999966,
"xmax": 689604.1490000002,
"ymax": 692606.049999997,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "BufferType",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Zone",
"type": "esriFieldTypeString",
"alias": "Zone",
"length": 5,
"domain": {
"type": "codedValue",
"name": "WS3_WTBD Floodplain Zone",
"description": "Valid water body floodplain zone values",
"codedValues": [
{
"name": "A - 100 Year Flood",
"code": "A"
},
{
"name": "A1 - 100 Year Flood",
"code": "A1"
},
{
"name": "A2 - 100 Year Flood",
"code": "A2"
},
{
"name": "AO - 100 Year Flood (2-3 ft Deep)",
"code": "AO"
},
{
"name": "B - 100 to 500 Year Flood",
"code": "B"
},
{
"name": "C - Minimal Flooding",
"code": "C"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "BufferType",
"type": "esriFieldTypeString",
"alias": "Buffer Type",
"length": 50,
"domain": {
"type": "codedValue",
"name": "WS3_WTBD Floodplain Buffer Type",
"description": "Valid water body floodplain buffer type values",
"codedValues": [
{
"name": "75 ft",
"code": "75 ft"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_396",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S345_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771077332000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1120,
"name": "River Buffer",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1100,
"name": "Floodplain"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
85,
255,
0,
0
],
"outline": {
"type": "esriSLS",
"style": "esriSLSDash",
"color": [
85,
255,
0,
255
],
"width": 1
}
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 672605,
"ymin": 638359.8125,
"xmax": 690247.125,
"ymax": 714976.5,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "BufferType",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "BufferType",
"type": "esriFieldTypeString",
"alias": "Buffer Type",
"length": 50,
"domain": {
"type": "codedValue",
"name": "WS3_WTBD River Buffer Type",
"description": "Valid water body river buffer type values",
"codedValues": [
{
"name": "750 ft",
"code": "750 ft"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_401",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S350_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771077332000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1130,
"name": "Floodplain",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1100,
"name": "Floodplain"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "Zone",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
170,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 1
}
},
"value": "A",
"label": "A - 100 Year Flood"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
255,
223,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 1
}
},
"value": "A1",
"label": "A1 - 100 Year Flood"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
115,
178,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 1
}
},
"value": "A2",
"label": "A2 - 100 Year Flood"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
127,
127,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 1
}
},
"value": "AO",
"label": "AO - 100 Year Flood (2-3 ft Deep)"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
235,
175,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 1
}
},
"value": "B",
"label": "B - 100 to 500 Year Flood"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
190,
232,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
0
],
"width": 0.7
}
},
"value": "C",
"label": "C - Minimal Flooding"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 50,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 667190.75,
"ymin": 640969.625,
"xmax": 726218.625,
"ymax": 692531.0625,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Zone",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Zone",
"type": "esriFieldTypeString",
"alias": "Zone",
"length": 5,
"domain": {
"type": "codedValue",
"name": "WS3_WTBD Floodplain Zone",
"description": "Valid water body floodplain zone values",
"codedValues": [
{
"name": "A - 100 Year Flood",
"code": "A"
},
{
"name": "A1 - 100 Year Flood",
"code": "A1"
},
{
"name": "A2 - 100 Year Flood",
"code": "A2"
},
{
"name": "AO - 100 Year Flood (2-3 ft Deep)",
"code": "AO"
},
{
"name": "B - 100 to 500 Year Flood",
"code": "B"
},
{
"name": "C - Minimal Flooding",
"code": "C"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "I844Zone",
"fields": "Zone",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "UUID_398",
"fields": "GlobalID",
"isAscending": true,
"isUnique": true,
"description": ""
},
{
"name": "S347_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771077332000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1200,
"name": "Airport Land Use",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 1210,
"name": "Airport"
},
{
"id": 1220,
"name": "Airport Land Use"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 663970.5245000012,
"ymin": 655243.7915000021,
"xmax": 720682.8724999987,
"ymax": 720837.7154999971,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1210,
"name": "Airport",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1200,
"name": "Airport Land Use"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
0,
0,
255
],
"width": 0.7
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 677906.1750000007,
"ymin": 668971.450000003,
"xmax": 684994.1424999982,
"ymax": 676555.6194999963,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "SHAPE.STLength()",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_21",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S8_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1220,
"name": "Airport Land Use",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1200,
"name": "Airport Land Use"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "CompatibleLandUse",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
112,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "Approach Surface",
"label": "Approach Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
230,
169,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "Controlled Development",
"label": "Controlled Development"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
197,
0,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "Controlled Development Approach Surface",
"label": "Controlled Development Approach Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "Limited Development",
"label": "Limited Development"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
170,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "Limited Development Approach Surface",
"label": "Limited Development Approach Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"value": "No Development",
"label": "No Development"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 60,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 663970.5245000012,
"ymin": 655243.7915000021,
"xmax": 720682.8724999987,
"ymax": 720837.7154999971,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "CompatibleLandUse",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "CompatibleLandUse",
"type": "esriFieldTypeString",
"alias": "Compatible Land Use",
"length": 50,
"domain": {
"type": "codedValue",
"name": "WS3_AIR Land Use Compatible Land Use",
"description": "Valid airport land use compatible land use values",
"codedValues": [
{
"name": "Approach Surface",
"code": "Approach Surface"
},
{
"name": "Controlled Development",
"code": "Controlled Development"
},
{
"name": "Controlled Development Approach Surface",
"code": "Controlled Development Approach Surface"
},
{
"name": "Limited Development",
"code": "Limited Development"
},
{
"name": "Limited Development Approach Surface",
"code": "Limited Development Approach Surface"
},
{
"name": "No Development",
"code": "No Development"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_18",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S5_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1300,
"name": "Airport Height Check",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 1310,
"name": "Airport"
},
{
"id": 1320,
"name": "Airport Height Limitation Contour"
},
{
"id": 1330,
"name": "Airport Height Limitation Zone"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 663808.3115000017,
"ymin": 654992.8294999972,
"xmax": 724674.6215000004,
"ymax": 723976.6330000013,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1310,
"name": "Airport",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1300,
"name": "Airport Height Check"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
0,
0,
255
],
"width": 0.7
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 677906.1750000007,
"ymin": 668971.450000003,
"xmax": 684994.1424999982,
"ymax": 676555.6194999963,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "SHAPE.STLength()",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_21",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S8_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1320,
"name": "Airport Height Limitation Contour",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1300,
"name": "Airport Height Check"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
0,
0,
0,
255
],
"width": 0.7
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 663808.3115000017,
"ymin": 654992.8294999972,
"xmax": 724674.6215000004,
"ymax": 723976.6330000013,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "Elevation",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Elevation",
"type": "esriFieldTypeSingle",
"alias": "Elevation (ft.)",
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_15",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S2_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1330,
"name": "Airport Height Limitation Zone",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1300,
"name": "Airport Height Check"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "SurfaceType",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
230,
152,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "Approach Surface",
"label": "Approach Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
77,
168,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "Conical Surface",
"label": "Conical Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
230,
169,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "Horizontal Surface",
"label": "Horizontal Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
52,
52,
52,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "Primary Surface",
"label": "Primary Surface"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "Transitional Surface",
"label": "Transitional Surface"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
192,
197,
255
],
"toColor": [
252,
192,
197,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
180,
252,
179,
255
],
"toColor": [
180,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
184,
252,
255
],
"toColor": [
179,
184,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
202,
252,
252,
255
],
"toColor": [
202,
252,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
247,
199,
255
],
"toColor": [
252,
247,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
184,
250,
255
],
"toColor": [
252,
184,
250,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
230,
215,
252,
255
],
"toColor": [
230,
215,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
222,
255
],
"toColor": [
179,
252,
222,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
218,
252,
255
],
"toColor": [
179,
218,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
182,
255
],
"toColor": [
252,
212,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
216,
252,
204,
255
],
"toColor": [
216,
252,
204,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
202,
233,
255
],
"toColor": [
252,
202,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
222,
215,
255
],
"toColor": [
252,
222,
215,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 60,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 663808.3115000017,
"ymin": 654992.8294999972,
"xmax": 724674.6215000004,
"ymax": 723976.6330000013,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "SurfaceType",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "SurfaceType",
"type": "esriFieldTypeString",
"alias": "Surface Type",
"length": 25,
"domain": {
"type": "codedValue",
"name": "WS3_AIR Height Limitation Zone Surface Type",
"description": "Valid airport height limitation zone surface type values",
"codedValues": [
{
"name": "Approach Surface",
"code": "Approach Surface"
},
{
"name": "Conical Surface",
"code": "Conical Surface"
},
{
"name": "Horizontal Surface",
"code": "Horizontal Surface"
},
{
"name": "Primary Surface",
"code": "Primary Surface"
},
{
"name": "Transitional Surface",
"code": "Transitional Surface"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "Elevation",
"type": "esriFieldTypeSingle",
"alias": "Elevation (ft.)",
"domain": null
},
{
"name": "Ratio",
"type": "esriFieldTypeString",
"alias": "Ratio",
"length": 10,
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_20",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S7_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1400,
"name": "Airport Noise Contours",
"type": "Group Layer",
"description": "",
"geometryType": null,
"copyrightText": "",
"parentLayer": null,
"subLayers": [
{
"id": 1410,
"name": "Airport"
},
{
"id": 1420,
"name": "Airport Current Noise Contour"
},
{
"id": 1430,
"name": "Airport Future Noise Contour"
}
],
"minScale": 0,
"maxScale": 0,
"defaultVisibility": false,
"extent": {
"xmin": 652837.7864999995,
"ymin": 655452.9704999998,
"xmax": 722849.3449999988,
"ymax": 692391.8154999986,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeNone",
"displayField": "",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": null,
"geometryField": {},
"indexes": [],
"subtypes": [],
"relationships": [],
"canModifyLayer": false,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query",
"supportsStatistics": false,
"supportsExceedsLimitStatistics": false,
"supportsAdvancedQueries": false,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": false,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": false,
"supportsPercentileStatistics": false,
"supportsHavingClause": false,
"supportsOrderBy": false,
"supportsDistinct": false,
"supportsCountDistinct": false,
"supportsPagination": false,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": false,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": false
},
"supportsDatumTransformation": true,
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasMetadata": true,
"isDataArchived": false,
"archivingInfo": {
"supportsQueryWithHistoricMoment": false,
"startArchivingMoment": -1
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": false
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1410,
"name": "Airport",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolyline",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1400,
"name": "Airport Noise Contours"
},
"subLayers": [],
"minScale": 240000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "simple",
"symbol": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
255,
0,
0,
255
],
"width": 0.7
}
},
"scaleSymbols": true,
"transparency": 0,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 677906.1750000007,
"ymin": 668971.450000003,
"xmax": 684994.1424999982,
"ymax": 676555.6194999963,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "SHAPE.STLength()",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_21",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S8_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1420,
"name": "Airport Current Noise Contour",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1400,
"name": "Airport Noise Contours"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "DayNightLevel",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
197,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "45",
"label": "45"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
197,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "50",
"label": "50"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
76,
230,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "55",
"label": "55"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
132,
0,
168,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "60",
"label": "60"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
170,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "65",
"label": "65"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
255,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "70",
"label": "70"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "75",
"label": "75"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
246,
252,
255
],
"toColor": [
212,
246,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
239,
182,
252,
255
],
"toColor": [
239,
182,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
250,
252,
179,
255
],
"toColor": [
250,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
185,
182,
255
],
"toColor": [
252,
185,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
199,
255
],
"toColor": [
179,
252,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
192,
203,
252,
255
],
"toColor": [
192,
203,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
242,
255
],
"toColor": [
252,
212,
242,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
235,
215,
255
],
"toColor": [
252,
235,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
222,
252,
215,
255
],
"toColor": [
222,
252,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
190,
179,
252,
255
],
"toColor": [
190,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
179,
212,
255
],
"toColor": [
252,
179,
212,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
192,
252,
233,
255
],
"toColor": [
192,
252,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
223,
252,
255
],
"toColor": [
179,
223,
252,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 60,
"labelingInfo": null
},
"defaultVisibility": true,
"extent": {
"xmin": 652837.7864999995,
"ymin": 655452.9704999998,
"xmax": 722849.3449999988,
"ymax": 692391.8154999986,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "DayNightLevel",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 10,
"domain": {
"type": "codedValue",
"name": "WS3_AIR Noise Contour Type",
"description": "Valid airport noise contour type values",
"codedValues": [
{
"name": "Current",
"code": "Current"
},
{
"name": "Future",
"code": "Future"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "DayNightLevel",
"type": "esriFieldTypeSmallInteger",
"alias": "Day-night Level (dBA)",
"domain": {
"type": "codedValue",
"name": "WS3_AIR Noise Contour Day-night Level",
"description": "Valid airport noise contour day-night level values",
"codedValues": [
{
"name": "45",
"code": 45
},
{
"name": "50",
"code": 50
},
{
"name": "55",
"code": 55
},
{
"name": "60",
"code": 60
},
{
"name": "65",
"code": 65
},
{
"name": "70",
"code": 70
},
{
"name": "75",
"code": 75
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_17",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S4_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
},
{
"currentVersion": 11.1,
"cimVersion": "3.1.0",
"id": 1430,
"name": "Airport Future Noise Contour",
"type": "Feature Layer",
"description": "",
"geometryType": "esriGeometryPolygon",
"sourceSpatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.001,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 2000,
"falseZ": -100000,
"zUnits": 2000,
"falseM": 0,
"mUnits": 1
},
"sourceHeightModelInfo": {
"heightModel": "gravity_related_height",
"vertCRS": "NAVD88_height_(ftUS)",
"heightUnit": "us-foot"
},
"copyrightText": "",
"parentLayer": {
"id": 1400,
"name": "Airport Noise Contours"
},
"subLayers": [],
"minScale": 600000,
"maxScale": 0,
"referenceScale": 0.0,
"drawingInfo": {
"renderer": {
"type": "uniqueValue",
"field1": "DayNightLevel",
"uniqueValueInfos": [
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
0,
197,
255,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "45",
"label": "45"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
0,
197,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "50",
"label": "50"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
76,
230,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "55",
"label": "55"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
132,
0,
168,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "60",
"label": "60"
},
{
"symbol": {
"type": "esriSFS",
"style": "esriSFSSolid",
"color": [
255,
170,
0,
255
],
"outline": {
"type": "esriSLS",
"style": "esriSLSSolid",
"color": [
110,
110,
110,
255
],
"width": 0.7
}
},
"value": "65",
"label": "65"
}
],
"fieldDelimiter": ",",
"authoringInfo": {
"colorRamp": {
"type": "multipart",
"colorRamps": [
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
212,
246,
252,
255
],
"toColor": [
212,
246,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
239,
182,
252,
255
],
"toColor": [
239,
182,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
250,
252,
179,
255
],
"toColor": [
250,
252,
179,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
185,
182,
255
],
"toColor": [
252,
185,
182,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
252,
199,
255
],
"toColor": [
179,
252,
199,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
192,
203,
252,
255
],
"toColor": [
192,
203,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
212,
242,
255
],
"toColor": [
252,
212,
242,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
235,
215,
255
],
"toColor": [
252,
235,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
222,
252,
215,
255
],
"toColor": [
222,
252,
215,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
190,
179,
252,
255
],
"toColor": [
190,
179,
252,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
252,
179,
212,
255
],
"toColor": [
252,
179,
212,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
192,
252,
233,
255
],
"toColor": [
192,
252,
233,
255
]
},
{
"type": "algorithmic",
"algorithm": "esriCIELabAlgorithm",
"fromColor": [
179,
223,
252,
255
],
"toColor": [
179,
223,
252,
255
]
}
]
}
}
},
"scaleSymbols": true,
"transparency": 60,
"labelingInfo": null
},
"defaultVisibility": false,
"extent": {
"xmin": 652837.7864999995,
"ymin": 655452.9704999998,
"xmax": 722849.3449999988,
"ymax": 692391.8154999986,
"spatialReference": {
"wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]",
"xyTolerance": 0.003280833333333333,
"zTolerance": 0.001,
"mTolerance": 0.001,
"falseX": -17796300,
"falseY": -47965700,
"xyUnits": 3048.0060960121928,
"falseZ": -100000,
"zUnits": 10000,
"falseM": -100000,
"mUnits": 10000
}
},
"hasAttachments": false,
"htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText",
"displayField": "DayNightLevel",
"typeIdField": null,
"subtypeFieldName": null,
"subtypeField": null,
"defaultSubtypeCode": null,
"fields": [
{
"name": "OBJECTID",
"type": "esriFieldTypeOID",
"alias": "Object ID",
"domain": null
},
{
"name": "Type",
"type": "esriFieldTypeString",
"alias": "Type",
"length": 10,
"domain": {
"type": "codedValue",
"name": "WS3_AIR Noise Contour Type",
"description": "Valid airport noise contour type values",
"codedValues": [
{
"name": "Current",
"code": "Current"
},
{
"name": "Future",
"code": "Future"
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "DayNightLevel",
"type": "esriFieldTypeSmallInteger",
"alias": "Day-night Level (dBA)",
"domain": {
"type": "codedValue",
"name": "WS3_AIR Noise Contour Day-night Level",
"description": "Valid airport noise contour day-night level values",
"codedValues": [
{
"name": "45",
"code": 45
},
{
"name": "50",
"code": 50
},
{
"name": "55",
"code": 55
},
{
"name": "60",
"code": 60
},
{
"name": "65",
"code": 65
},
{
"name": "70",
"code": 70
},
{
"name": "75",
"code": 75
}
],
"mergePolicy": "esriMPTDefaultValue",
"splitPolicy": "esriSPTDuplicate"
}
},
{
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape",
"domain": null
},
{
"name": "SHAPE.STArea()",
"type": "esriFieldTypeDouble",
"alias": "Area (sq. ft.)",
"domain": null
},
{
"name": "SHAPE.STLength()",
"type": "esriFieldTypeDouble",
"alias": "Perimeter Length (ft.)",
"domain": null
},
{
"name": "GlobalID",
"type": "esriFieldTypeGlobalID",
"alias": "GlobalID",
"length": 38,
"domain": null
}
],
"geometryField": {
"name": "SHAPE",
"type": "esriFieldTypeGeometry",
"alias": "Shape"
},
"indexes": [
{
"name": "UUID_17",
"fields": "GlobalID",
"isAscending": true,
"isUnique": false,
"description": ""
},
{
"name": "S4_idx",
"fields": "SHAPE",
"isAscending": true,
"isUnique": true,
"description": ""
}
],
"subtypes": [],
"relationships": [],
"canModifyLayer": true,
"canScaleSymbols": false,
"hasLabels": false,
"capabilities": "Map,Query,Data",
"maxRecordCount": 2000,
"supportsStatistics": true,
"supportsExceedsLimitStatistics": true,
"supportsAdvancedQueries": true,
"hasZ": true,
"supportedQueryFormats": "JSON, geoJSON, PBF",
"isDataVersioned": true,
"ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true},
"useStandardizedQueries": true,
"supportedSpatialRelationships": [
"esriSpatialRelIntersects",
"esriSpatialRelContains",
"esriSpatialRelCrosses",
"esriSpatialRelEnvelopeIntersects",
"esriSpatialRelIndexIntersects",
"esriSpatialRelOverlaps",
"esriSpatialRelTouches",
"esriSpatialRelWithin",
"esriSpatialRelRelation"
],
"advancedQueryCapabilities": {
"useStandardizedQueries": true,
"supportsStatistics": true,
"supportsPercentileStatistics": true,
"supportsHavingClause": true,
"supportsOrderBy": true,
"supportsDistinct": true,
"supportsCountDistinct": true,
"supportsPagination": true,
"supportsLod": false,
"supportsQueryWithLodSR": false,
"supportsTrueCurve": true,
"supportsQueryWithDatumTransformation": true,
"supportsReturningQueryExtent": true,
"supportsQueryWithDistance": true,
"supportsSqlExpression": true,
"supportsTimeRelation": true,
"supportsSqlFormat": false,
"supportsQueryAnalytic": true
},
"supportsDatumTransformation": true,
"advancedQueryAnalyticCapabilities": {
"supportsLinearRegression": true,
"supportsAsync": false,
"supportsPercentileAnalytic": true
},
"dateFieldsTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"preferredTimeReference": {
"timeZone": "Mountain Standard Time",
"respectsDaylightSaving": true
},
"datesInUnknownTimezone": false,
"hasGeometryProperties": true,
"geometryProperties": {
"shapeAreaFieldName": "SHAPE.STArea()",
"shapeLengthFieldName": "SHAPE.STLength()",
"units": "esriFeet",
"mapUnits": {"uwkid": 9003}
},
"hasMetadata": true,
"isDataArchived": true,
"archivingInfo": {
"supportsQueryWithHistoricMoment": true,
"startArchivingMoment": 1771075223000
},
"supportsCoordinatesQuantization": true,
"supportsDynamicLegends": true
}
],
"tables": []
}