{ "layers": [ { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 100, "name": "Water", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 110, "name": "Fire Hydrant" }, { "id": 120, "name": "Valve" }, { "id": 130, "name": "Water Service Line" }, { "id": 140, "name": "Water Main Line" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 629119.0055, "ymin": 641136.5834999979, "xmax": 730761.9334999993, "ymax": 689819.7924999967, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 110, "name": "Fire Hydrant", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "a937b00a36d23e932454e5ca12261ef9", "imageData": "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", "contentType": "image/png", "width": 15, "height": 15, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674845.4305000007, "ymin": 643527.4575000033, "xmax": 709217.8770000003, "ymax": 689815.6180000007, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "HydrantSize", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "HydrantSize", "type": "esriFieldTypeSmallInteger", "alias": "Hydrant Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Fire Hydrant Size", "description": "Valid water firy hydrant size values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1153Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1153HydrantSize", "fields": "HydrantSize", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S522_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910583000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 120, "name": "Valve", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "c946d9971eaf14829f5c5eb2f6a5b2e4", "imageData": "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", "contentType": "image/png", "width": 9, "height": 9, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674797.6114999987, "ymin": 643527.0520000011, "xmax": 709220.2609999999, "ymax": 689807.6840000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "ValveType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ValveType", "type": "esriFieldTypeString", "alias": "Valve Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Valve Type", "description": "Valid water valve type values", "codedValues": [ { "name": "Gate", "code": "Gate" }, { "name": "Butterfly", "code": "Butterfly" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ValveSize", "type": "esriFieldTypeSmallInteger", "alias": "Valve Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Valve Size", "description": "Valid water valve size values", "codedValues": [ { "name": "2", "code": 2 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 }, { "name": "14", "code": 14 }, { "name": "16", "code": 16 }, { "name": "18", "code": 18 }, { "name": "20", "code": 20 }, { "name": "24", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1167Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167ValveSize", "fields": "ValveSize", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1167ValveType", "fields": "ValveType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S536_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910666000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 130, "name": "Water Service Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSDashDotDot", "color": [ 0, 92, 230, 255 ], "width": 1 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 629119.0055, "ymin": 643527.0520000011, "xmax": 730761.9334999993, "ymax": 689815.6180000007, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "ServiceLineType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ServiceLineType", "type": "esriFieldTypeString", "alias": "Service Line Type", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Service Line Type", "description": "Valid water service line type values", "codedValues": [ { "name": "Culinary Service", "code": "Culinary Service" }, { "name": "Sprinkler Service", "code": "Sprinkler Service" }, { "name": "Fire Service", "code": "Fire Service" }, { "name": "Fire Hydrant Service", "code": "Fire Hydrant Service" }, { "name": "Flush Hydrant Service", "code": "Flush Hydrant Service" }, { "name": "Culinary / Fire Service", "code": "Culinary / Fire Service" }, { "name": "Culinary / Fire Hydrant", "code": "Culinary / Fire Hydrant" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Size", "type": "esriFieldTypeDouble", "alias": "Size (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Service Line Size", "description": "Valid water service line size values", "codedValues": [ { "name": "0.5", "code": 0.5 }, { "name": "0.75", "code": 0.75 }, { "name": "1", "code": 1 }, { "name": "1.25", "code": 1.25 }, { "name": "1.5", "code": 1.5 }, { "name": "2", "code": 2 }, { "name": "2.5", "code": 2.5 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1152Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1152Size", "fields": "Size", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1152ServiceLine", "fields": "ServiceLineType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S521_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910566000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 140, "name": "Water Main Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 100, "name": "Water" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 92, 230, 255 ], "width": 2 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner IN ('Private', 'Parks')", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 0, 92, 230, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 669954.2635000013, "ymin": 641136.5834999979, "xmax": 730486.3040000014, "ymax": 689819.7924999967, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "codedValue", "name": "WS2_WTR Main Line Diameter", "description": "Valid water main line diameter values", "codedValues": [ { "name": "2", "code": 2 }, { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "12", "code": 12 }, { "name": "14", "code": 14 }, { "name": "16", "code": 16 }, { "name": "18", "code": 18 }, { "name": "20", "code": 20 }, { "name": "24", "code": 24 }, { "name": "120", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_WTR Owner", "description": "Valid water owner values", "codedValues": [ { "name": "City", "code": "City" }, { "name": "Private", "code": "Private" }, { "name": "Parks", "code": "Parks" }, { "name": "Falls Water", "code": "Falls Water" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "PipeClassification", "type": "esriFieldTypeString", "alias": "Pipe Classification", "length": 25, "domain": { "type": "codedValue", "name": "WS2_WTR Pipe Classification", "description": "Valid water pipe classification values", "codedValues": [ { "name": "Distribution", "code": "Distribution" }, { "name": "Transmission", "code": "Transmission" }, { "name": "Critical Infrastructure", "code": "Critical Infrastructure" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1154Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1154Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1154Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S523_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745910588000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 200, "name": "Sewer", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 210, "name": "Sewer Manhole" }, { "id": 220, "name": "Sewer Line" }, { "id": 230, "name": "Sewer Service Line" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 695866.438000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 210, "name": "Sewer Manhole", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "59db18049bc3de0810162914226eae5e", "imageData": "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", "contentType": "image/png", "width": 14, "height": 14, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 689763.7950000018, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "ManholeID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ManholeID", "type": "esriFieldTypeString", "alias": "Manhole ID", "length": 20, "domain": null }, { "name": "ManholeDiameter", "type": "esriFieldTypeSmallInteger", "alias": "Manhole Diameter (ft.)", "domain": { "type": "codedValue", "name": "WS2_UTIL Manhole Diameter", "description": "Valid utility manhole diameter values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "7", "code": 7 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "3", "code": 3 }, { "name": "5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeCoverSize", "type": "esriFieldTypeDouble", "alias": "Manhole Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Owner", "description": "Valid sewer owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "IBSD", "code": "IBSD" }, { "name": "Ammon", "code": "Ammon" }, { "name": "Private", "code": "Private" }, { "name": "Ucon", "code": "Ucon" }, { "name": "EIRSD", "code": "EIRSD" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeDouble", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "OutletElevation", "type": "esriFieldTypeDouble", "alias": "Outlet Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1245Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1245ManholeID", "fields": "ManholeID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S560_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915706000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 220, "name": "Sewer Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner = 'Private'", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 56, 168, 0, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 667767.1330000013, "ymin": 633747.811499998, "xmax": 727681.124499999, "ymax": 695866.438000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "PipeType", "type": "esriFieldTypeString", "alias": "Pipe Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Pipe Type", "description": "Valid sewer pipe type values", "codedValues": [ { "name": "Gravity", "code": "Gravity" }, { "name": "Forced Main", "code": "Forced Main" }, { "name": "Elevated", "code": "Elevated" }, { "name": "Siphon", "code": "Siphon" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "range", "name": "WS2_SWR Line Diameter", "description": "Valid sewer line diameter values", "range": [ 4, 60 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_SWR Owner", "description": "Valid sewer owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "IBSD", "code": "IBSD" }, { "name": "Ammon", "code": "Ammon" }, { "name": "Private", "code": "Private" }, { "name": "Ucon", "code": "Ucon" }, { "name": "EIRSD", "code": "EIRSD" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "UpInvertElevation", "type": "esriFieldTypeDouble", "alias": "Up Invert Elevation (ft.)", "domain": null }, { "name": "DownInvertElevation", "type": "esriFieldTypeDouble", "alias": "Down Invert Elevation (ft.)", "domain": null }, { "name": "Slope", "type": "esriFieldTypeDouble", "alias": "Slope", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "Collector_ID", "type": "esriFieldTypeString", "alias": "Collector ID", "length": 20, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1240Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1240PipeType", "fields": "PipeType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S555_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915662000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 230, "name": "Sewer Service Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 200, "name": "Sewer" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSDashDotDot", "color": [ 56, 168, 0, 255 ], "width": 1 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673163.9090000018, "ymin": 643612.2924999967, "xmax": 723950.1735000014, "ymax": 687739.5689999983, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "codedValue", "name": "WS2_SWR Service Line Diameter", "description": "Valid sewer service line diameter values", "codedValues": [ { "name": "3", "code": 3 }, { "name": "4", "code": 4 }, { "name": "5", "code": 5 }, { "name": "6", "code": 6 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1244Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1244Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S559_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745915692000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 300, "name": "Storm", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 310, "name": "Dry Well" }, { "id": 320, "name": "French Drain" }, { "id": 330, "name": "Storm Manhole" }, { "id": 340, "name": "Inlet Box" }, { "id": 350, "name": "Catch Basin" }, { "id": 360, "name": "Storm Line" }, { "id": 370, "name": "Other Conveyance" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 673209.5789999999, "ymin": 638864.5090000033, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 310, "name": "Dry Well", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "d4a8a7cb844e95944057ded944b3f151", "imageData": "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", "contentType": "image/png", "width": 16, "height": 16, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 679329.7030000016, "ymin": 659167.699000001, "xmax": 702986.5364999995, "ymax": 672312.7280000001, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "DryWellID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "DryWellID", "type": "esriFieldTypeString", "alias": "Dry Well ID", "length": 20, "domain": null }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "BottomElevation", "type": "esriFieldTypeSingle", "alias": "Bottom Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1317Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1317Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1317DryWellID", "fields": "DryWellID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S590_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918840000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 320, "name": "French Drain", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "f0258ffb3fbae43c57e2cbfd2aace83f", "imageData": "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", "contentType": "image/png", "width": 13, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674517.2325000018, "ymin": 645753.3980000019, "xmax": 704373.2705000006, "ymax": 678276.2480000034, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "FrenchDrainID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "FrenchDrainID", "type": "esriFieldTypeString", "alias": "French Drain ID", "length": 20, "domain": null }, { "name": "CoverSize", "type": "esriFieldTypeDouble", "alias": "Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1306Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1306Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1306FrenchDrain", "fields": "FrenchDrainID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S579_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918781000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 330, "name": "Storm Manhole", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "74bc710ff1a41d6af1b32a1a546c1afd", "imageData": "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", "contentType": "image/png", "width": 14, "height": 14, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673272.8154999986, "ymin": 638864.5090000033, "xmax": 706473.2025000006, "ymax": 689779.2459999993, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "ManholeID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "ManholeID", "type": "esriFieldTypeString", "alias": "Manhole ID", "length": 20, "domain": null }, { "name": "ManholeDiameter", "type": "esriFieldTypeSmallInteger", "alias": "Manhole Diameter (ft.)", "domain": { "type": "codedValue", "name": "WS2_UTIL Manhole Diameter", "description": "Valid utility manhole diameter values", "codedValues": [ { "name": "4", "code": 4 }, { "name": "6", "code": 6 }, { "name": "7", "code": 7 }, { "name": "8", "code": 8 }, { "name": "10", "code": 10 }, { "name": "3", "code": 3 }, { "name": "5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeCoverSize", "type": "esriFieldTypeDouble", "alias": "Manhole Cover Size (in.)", "domain": { "type": "range", "name": "WS2_UTIL Manhole Cover Size", "description": "Valid utility manhole cover size values", "range": [ 18, 36 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ManholeType", "type": "esriFieldTypeString", "alias": "Manhole Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Manhole Type", "description": "Valid storm manhole type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 5", "code": "Type 5" }, { "name": "CDS", "code": "CDS" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "RingElevation", "type": "esriFieldTypeSingle", "alias": "Ring Elevation (ft.)", "domain": null }, { "name": "OutletElevation", "type": "esriFieldTypeSingle", "alias": "Outlet Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "LastInspectDate", "type": "esriFieldTypeDate", "alias": "Last Inspect Date", "length": 8, "domain": null }, { "name": "LastDateCleaned", "type": "esriFieldTypeDate", "alias": "Last Date Cleaned", "length": 8, "domain": null }, { "name": "NeedCleaning", "type": "esriFieldTypeString", "alias": "Need Cleaning", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1310Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeType", "fields": "ManholeType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeDiam", "fields": "ManholeDiameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1310ManholeID", "fields": "ManholeID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S583_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918801000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 340, "name": "Inlet Box", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "e9b4a3e243aebc0d191500844e98300c", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAsAAAASCAYAAACNdSR1AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABAUlEQVQokZ3SMU6EQBTG8VEYkYwxwRi7bTSxNJZwC+IZ6GjopOAQdISahnKOwQmoCXFiyCygZhJZlMGsFcNLjLuv/uWfr3g6OuD0Y/AZQujpD5cv8aWu689xHF9gjMkCzVEUYc65gpFlWe++7z+uk2mavnHO1c3DMNzk+W9Aua7r9hNVPM+zJoQAWEp5ArBpmq+e592vcZIku7quwYxrSiko932PQXmapvOqqgAex/EUYELISxAEd2ucZdmOMaZiIcRtGIagzBgzQdkwjK3rups1ppR+NU2jYozxh23boEwI+Qbltm0fHMf51DRNea6yLMGMrZTyqigKUF7eUS/6r/sB/RRhpJ5ibC0AAAAASUVORK5CYII=", "contentType": "image/png", "width": 8, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.Rotate", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674257.7529999986, "ymin": 639332.3095000014, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "InletBoxID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "InletBoxID", "type": "esriFieldTypeString", "alias": "Inlet Box ID", "length": 20, "domain": null }, { "name": "InletBoxType", "type": "esriFieldTypeString", "alias": "Inlet Box Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Inlet Box Type", "description": "Valid storm inlet box type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 2", "code": "Type 2" }, { "name": "Type 3", "code": "Type 3" }, { "name": "Type 4", "code": "Type 4" }, { "name": "Type 5", "code": "Type 5" }, { "name": "Type 8", "code": "Type 8" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "GrateElevation", "type": "esriFieldTypeSingle", "alias": "Grate Elevation (ft.)", "domain": null }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Rotate", "type": "esriFieldTypeSmallInteger", "alias": "Rotate", "domain": { "type": "range", "name": "WS2_CIF Rotate", "description": "Valid rotate values", "range": [ 0, 360 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SideOpenerBlocked", "type": "esriFieldTypeString", "alias": "Side Opener Blocked", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1312Rotate", "fields": "Rotate", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxTyp", "fields": "InletBoxType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxID", "fields": "InletBoxID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S585_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918812000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 350, "name": "Catch Basin", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 2400, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "59ad5d42e1c5f92107329d7cf015766b", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAsAAAASCAYAAACNdSR1AAAACXBIWXMAAA7EAAAOxAGVKw4bAAABDUlEQVQokWNhIAGwkKOYjYGBIQiPuhXIivlYmBjLixOteFiYmbhhKv7/Z/g/beUZ1g+fvqMoZuDlZf8Y5q5tgG7k+j3XP3z49B3Vzb9+/hXbefQuhv0fv/4AORFV8T8GBubvP35jKP737z8jhmIOdpbnAc4aauiK1+y+9vPFm6/ozvgjcuD0AwyTP339xYph8t//DBzPXn3GUPz7z18mDMWcHCxPorx1ldEVbzt8++ert2jO+Pb9l9LkpacwTH719isnhsmsrMxvHMwUZNEV7z/94Pfbj2jhzMrC9ElXVQzDZC52lj8YJn/49FMvoXrjd2Zm1MR198l7DGe8+f//v9Dl2y8xTEYGZCVRogAAN1Nj4ZCbkk0AAAAASUVORK5CYII=", "contentType": "image/png", "width": 8, "height": 13, "angle": 0, "xoffset": 0, "yoffset": 0 }, "visualVariables": [ { "type": "rotationInfo", "valueExpressionTitle": "Custom", "valueExpression": "$feature.Rotate", "rotationType": "arithmetic" } ] }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674257.7529999986, "ymin": 639332.3095000014, "xmax": 706481.7875000015, "ymax": 689800.1105000004, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "InletBoxID", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "InletBoxID", "type": "esriFieldTypeString", "alias": "Inlet Box ID", "length": 20, "domain": null }, { "name": "InletBoxType", "type": "esriFieldTypeString", "alias": "Inlet Box Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Inlet Box Type", "description": "Valid storm inlet box type values", "codedValues": [ { "name": "Type 1", "code": "Type 1" }, { "name": "Type 2", "code": "Type 2" }, { "name": "Type 3", "code": "Type 3" }, { "name": "Type 4", "code": "Type 4" }, { "name": "Type 5", "code": "Type 5" }, { "name": "Type 8", "code": "Type 8" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "GrateElevation", "type": "esriFieldTypeSingle", "alias": "Grate Elevation (ft.)", "domain": null }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Depth", "type": "esriFieldTypeDouble", "alias": "Depth (ft.)", "domain": { "type": "range", "name": "WS2_UTIL Depth", "description": "Valid utility depth values", "range": [ 0, 40 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "FloorElevation", "type": "esriFieldTypeSingle", "alias": "Floor Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Rotate", "type": "esriFieldTypeSmallInteger", "alias": "Rotate", "domain": { "type": "range", "name": "WS2_CIF Rotate", "description": "Valid rotate values", "range": [ 0, 360 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SideOpenerBlocked", "type": "esriFieldTypeString", "alias": "Side Opener Blocked", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No/N/A", "description": "Valid Yes, No, or N/A values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" }, { "name": "N/A", "code": "N/A" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "BrokenPartsPieces", "type": "esriFieldTypeString", "alias": "Broken Parts/Pieces", "length": 10, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1312Rotate", "fields": "Rotate", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxTyp", "fields": "InletBoxType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1312InletBoxID", "fields": "InletBoxID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S585_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918812000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 360, "name": "Storm Line", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": [ { "labelExpressionInfo": { "expression": "DomainName($feature, 'Owner')", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "none", "multiPart": "labelPerFeature", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Owner = 'Private'", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Private", "priority": -1, "symbol": { "type": "esriTS", "color": [ 255, 0, 197, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 9, "style": "normal", "weight": "normal", "decoration": "none" } } }, { "labelExpressionInfo": { "expression": "DomainName($feature, 'Diameter') + \"\\\"\"", "title": "Custom" }, "labelPlacement": "esriServerLinePlacementAboveAlong", "textLayout": "straight", "deconflictionStrategy": "dynamic", "allowOverrun": true, "repeatLabel": false, "lineConnection": "minimizeLabels", "stackLabel": true, "stackAlignment": "dynamic", "removeDuplicates": "none", "stackRowLength": 24, "where": "Diameter IS NOT NULL", "useCodedValues": true, "maxScale": 0, "minScale": 1200, "name": "Size", "priority": -1, "symbol": { "type": "esriTS", "color": [ 137, 112, 68, 255 ], "backgroundColor": null, "borderLineColor": null, "borderLineSize": null, "verticalAlignment": "bottom", "horizontalAlignment": "left", "rightToLeft": false, "angle": 0, "xoffset": 0, "yoffset": 0, "kerning": true, "haloColor": [ 255, 255, 255, 191 ], "haloSize": 1.5, "font": { "family": "Tahoma", "size": 10, "style": "normal", "weight": "normal", "decoration": "none" } } } ] }, "defaultVisibility": true, "extent": { "xmin": 673209.5789999999, "ymin": 638864.5090000033, "xmax": 706481.7875000015, "ymax": 687807.9514999986, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Diameter", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "FlowType", "type": "esriFieldTypeString", "alias": "Flow Type", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Flow Type", "description": "Valid storm flow type values", "codedValues": [ { "name": "Gravity", "code": "Gravity" }, { "name": "Pressure", "code": "Pressure" }, { "name": "Siphon", "code": "Siphon" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Diameter", "type": "esriFieldTypeSmallInteger", "alias": "Diameter (in.)", "domain": { "type": "range", "name": "WS2_STM Line Diameter", "description": "Valid storm line diameter values", "range": [ 2, 74 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "UpInvertElevation", "type": "esriFieldTypeSingle", "alias": "Up Invert Elevation (ft.)", "domain": null }, { "name": "DownInvertElevation", "type": "esriFieldTypeSingle", "alias": "Down Invert Elevation (ft.)", "domain": null }, { "name": "Slope", "type": "esriFieldTypeDouble", "alias": "Slope", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "Collector_ID", "type": "esriFieldTypeString", "alias": "Collector ID", "length": 20, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1318Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318Diameter", "fields": "Diameter", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1318FlowType", "fields": "FlowType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S591_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": true, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918845000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 370, "name": "Other Conveyance", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 300, "name": "Storm" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 51, 51, 51, 255 ], "width": 13 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 677344.1585000008, "ymin": 645960.25, "xmax": 704293.2369999997, "ymax": 683598.9940000027, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "MethodOfConveyance", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "MethodOfConveyance", "type": "esriFieldTypeString", "alias": "Method of Conveyance", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Method of Conveyance", "description": "Valid storm method of conveyance values", "codedValues": [ { "name": "Storm Tunnel", "code": "Storm Tunnel" }, { "name": "Open Channel", "code": "Open Channel" }, { "name": "Underground Channel", "code": "Underground Channel" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Owner", "type": "esriFieldTypeString", "alias": "Owner", "length": 20, "domain": { "type": "codedValue", "name": "WS2_STM Owner", "description": "Valid storm owner values", "codedValues": [ { "name": "Idaho Falls", "code": "Idaho Falls" }, { "name": "Private", "code": "Private" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "InvertElevation", "type": "esriFieldTypeSingle", "alias": "Invert Elevation (ft.)", "domain": null }, { "name": "Abandoned", "type": "esriFieldTypeString", "alias": "Abandoned", "length": 5, "domain": { "type": "codedValue", "name": "WS2_CIF Yes/No", "description": "Valid Yes/No Values", "codedValues": [ { "name": "Yes", "code": "Yes" }, { "name": "No", "code": "No" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I1307Abandoned", "fields": "Abandoned", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1307Owner", "fields": "Owner", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I1307MethodOfCon", "fields": "MethodOfConveyance", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S580_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1745918786000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 400, "name": "Electric", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 410, "name": "Transformer" }, { "id": 420, "name": "Streetlight" }, { "id": 430, "name": "Secondary Conductor" }, { "id": 440, "name": "Primary Conductor" }, { "id": 450, "name": "Electric/Fiber Conduit" } ], "minScale": 12000, "maxScale": 0, "defaultVisibility": true, "extent": { "xmin": 643690.5494070798, "ymin": 639229.2276111543, "xmax": 707061.4210246615, "ymax": 695982.9940246567, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 410, "name": "Transformer", "type": "Feature Layer", "description": "

These are features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 400, "name": "Electric" }, "subLayers": [], "minScale": 5000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "ae8742f85343d434cc5e67cc5c21356d", "imageData": "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", "contentType": "image/png", "width": 17, "height": 16, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 643690.5494070798, "ymin": 639234.0107380748, "xmax": 707061.4210246615, "ymax": 688815.7550783232, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "assetgroup", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "WS1_Lifecycle_Status_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Proposed and In Service", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "In Service and Planned Removal", "code": 6 }, { "name": "Maintenance", "code": 7 }, { "name": "Design", "code": 11 }, { "name": "Abandoned", "code": 12 }, { "name": "Removed", "code": 13 }, { "name": "Retired", "code": 14 }, { "name": "NA", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S182_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Ground", "description": "Ground", "codedValues": [ { "name": "Ground", "code": 0 }, { "name": "Bound", "code": 31 }, { "name": "Rod", "code": 32 }, { "name": "Voltage Grid", "code": 33 }, { "name": "Stray Voltage Isolator", "code": 34 }, { "name": "Grounding Switch", "code": 35 }, { "name": "Cross Bond", "code": 36 }, { "name": "Ground Plate", "code": 37 }, { "name": "Ground Joint", "code": 38 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Ground_Type", "description": "Ground Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bound", "code": 1 }, { "name": "Mesh", "code": 2 }, { "name": "Rod", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 1, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit", "description": "High Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor HV", "code": 41 }, { "name": "Switch and Breaker HV", "code": 42 }, { "name": "Voltage Regulator HV", "code": 43 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 3, "name": "High Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation", "description": "High Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery HV", "code": 61 }, { "name": "Biomass HV", "code": 62 }, { "name": "Coal HV", "code": 63 }, { "name": "Gas Turbine HV", "code": 64 }, { "name": "Geothermal HV", "code": 65 }, { "name": "Hydro HV", "code": 66 }, { "name": "Nuclear HV", "code": 67 }, { "name": "Photovoltaic Solar HV", "code": 68 }, { "name": "Thermal Solar HV", "code": 69 }, { "name": "Wind HV", "code": 70 }, { "name": "AC Wave HV", "code": 71 }, { "name": "Generator HV", "code": 72 }, { "name": "Interconnect HV", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 4, "name": "High Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse", "description": "High Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Station Disconnect Fuse HV", "code": 581 }, { "name": "AC Station Load Break Fuse HV", "code": 582 }, { "name": "AC Load Break Disconnect Fuse HV", "code": 583 }, { "name": "AC Load Break Fuse HV - Controller", "code": 584 }, { "name": "AC Disconnect Fuse HV - Controller", "code": 585 }, { "name": "AC Load Break Disconnect Fuse HV - Controller", "code": 586 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current", "description": "List of valid High Voltage Switching and Protective Maximum Continuous Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "1200 A", "code": 1200 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "3000 A", "code": 3000 }, { "name": "6000 A", "code": 6000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current", "description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "60 kA", "code": 60000 }, { "name": "80 kA", "code": 80000 }, { "name": "90 kA", "code": 90000 }, { "name": "2 kA", "code": 2000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 43, "name": "High Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay", "description": "High Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator HV", "code": 80 }, { "name": "Instrument Transformer HV", "code": 81 }, { "name": "Load Monitor HV", "code": 82 }, { "name": "Relay HV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Phase_Angle_Offset_Range", "description": "Phase Offset values 0 - 60", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 5, "name": "High Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion", "description": "High Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Inverter HV", "code": 101 }, { "name": "Rectifier HV", "code": 102 }, { "name": "Bidirectional HV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_DC_Voltage", "description": "Valid High Voltage Direct Current Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "270 kV", "code": 270000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "500 kV", "code": 500000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1000 kV", "code": 1000000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 }, { "name": "1400 kV", "code": 1400000 }, { "name": "1500 kV", "code": 1500000 }, { "name": "1800 kV", "code": 1800000 }, { "name": "2500 kV", "code": 2500000 }, { "name": "3000 kV", "code": 3000000 }, { "name": "4000 kV", "code": 4000000 }, { "name": "5000 kV", "code": 5000000 }, { "name": "6000 kV", "code": 6000000 }, { "name": "6400 kV", "code": 6400000 }, { "name": "7200 kV", "code": 7200000 }, { "name": "8000 kV", "code": 8000000 }, { "name": "10000 kV", "code": 10000000 }, { "name": "12000 kV", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 6, "name": "High Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting", "description": "High Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Capacitor HV", "code": 121 }, { "name": "AC Wave Trap HV", "code": 122 }, { "name": "AC Reactor HV", "code": 123 }, { "name": "DC Capacitor HV", "code": 124 }, { "name": "DC Reactor HV", "code": 125 }, { "name": "Synchronous Condenser HV", "code": 126 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Power_Factor_Correcting_Type", "description": "Type of Power Factor Correcting Equipment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 7, "name": "High Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator", "description": "High Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase HV", "code": 171 }, { "name": "AC Three Phase HV", "code": 172 }, { "name": "DC Regulator HV", "code": 173 }, { "name": "Frequency Converter HV", "code": 174 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 8, "name": "High Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service", "description": "High Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "AC Metering HV", "code": 161 }, { "name": "DC Metering HV", "code": 162 }, { "name": "High Voltage Premise HV", "code": 163 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 9, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch", "description": "High Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Circuit Breaker HV", "code": 181 }, { "name": "AC Disconnect HV", "code": 182 }, { "name": "AC Switchgear HV", "code": 183 }, { "name": "DC Circuit Breaker HV", "code": 184 }, { "name": "DC Disconnect HV", "code": 185 }, { "name": "DC Switchgear HV", "code": 186 }, { "name": "AC Bus Tie Breaker HV", "code": 187 }, { "name": "DC Bus Tie Breaker HV", "code": 188 }, { "name": "AC Disconnect - Grounded HV", "code": 189 }, { "name": "AC Breaker Bypass HV", "code": 190 }, { "name": "AC Circuit Breaker HV - Controller", "code": 191 }, { "name": "AC Station Disconnect HV", "code": 192 }, { "name": "AC Station Load Break Disconnect HV - Controller", "code": 193 }, { "name": "DC Circuit Breaker HV - Controller", "code": 194 }, { "name": "AC Disconnect HV - Controller", "code": 195 }, { "name": "AC Grounding HV", "code": 196 }, { "name": "AC Thyristor HV", "code": 197 }, { "name": "DC Thyristor HV", "code": 198 }, { "name": "AC Transfer Switch HV", "code": 199 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps", "description": "High Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".6 kA", "code": 600 }, { "name": "1.2 kA", "code": 1200 }, { "name": "1.25 kA", "code": 1250 }, { "name": "1.6 kA", "code": 1600 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 10, "name": "High Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer", "description": "High Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "AC Single Phase - HV->MV", "code": 201 }, { "name": "AC Three Phase - HV->MV", "code": 202 }, { "name": "DC Power - HV->HV", "code": 203 }, { "name": "Grounding Transformer - HV->MV", "code": 204 }, { "name": "Station - HV->MV", "code": 205 }, { "name": "Station Three Winding - HV->HV-HV", "code": 206 }, { "name": "Station Three Winding - HV->HV-MV", "code": 207 }, { "name": "Phase Control - HV->HV", "code": 208 }, { "name": "Station Three Winding - HV->HV-LV", "code": 209 }, { "name": "Station Step Up - MV->HV", "code": 210 }, { "name": "Station Step - HV->HV", "code": 211 }, { "name": "Station Three Winding - HV->MV-MV", "code": 212 }, { "name": "Station Three Winding - HV->MV-LV", "code": 213 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 11, "name": "High Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Line Hardware", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 61, "name": "High Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding HV", "code": 871 }, { "name": "DC Transformer Winding HV", "code": 872 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 48, "name": "High Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker", "description": "Medium Voltage Circuit Breaker", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "Isolator Switch MV", "code": 501 }, { "name": "Single Phase Circuit Breaker MV", "code": 502 }, { "name": "Three Phase Circuit Breaker MV", "code": 503 }, { "name": "Single Phase Circuit Breaker MV - Controller", "code": 512 }, { "name": "Three Phase Circuit Breaker MV - Controller", "code": 513 }, { "name": "Network Protector MV", "code": 515 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Medium Voltage Circuit Breaker Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "1250 A", "code": 1250 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "2500 A", "code": 2500 }, { "name": "3000 A", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 26, "name": "Medium Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit", "description": "Medium Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor MV", "code": 521 }, { "name": "Circuit Breaker MV", "code": 522 }, { "name": "Recloser MV", "code": 523 }, { "name": "Transfer Switch Controller MV", "code": 524 }, { "name": "Regulator MV", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 27, "name": "Medium Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow", "description": "Medium Voltage Elbow", "codedValues": [ { "name": "Elbow", "code": 0 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Load Break Feedthru MV", "code": 541 }, { "name": "Load Break Junction MV", "code": 542 }, { "name": "Single Phase Dead Break MV", "code": 543 }, { "name": "Single Phase Load Break MV", "code": 544 }, { "name": "Three Phase Dead Break MV", "code": 545 }, { "name": "Three Phase Load Break MV", "code": 546 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 28, "name": "Medium Voltage Elbow" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse", "description": "Medium Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Bayonet Fuse MV", "code": 561 }, { "name": "Fault Limiter Fuse MV", "code": 562 }, { "name": "Indoor Fuse MV", "code": 563 }, { "name": "Overhead Cutout Disconnect Fuse MV", "code": 564 }, { "name": "Overhead Cutout Load Break Fuse MV", "code": 565 }, { "name": "Overhead Cutout Sectionalizer Fuse MV", "code": 566 }, { "name": "Overhead Cutout Solid Blade Fuse MV", "code": 567 }, { "name": "Cabinet Fuse MV", "code": 568 }, { "name": "Underground Fuse MV", "code": 569 }, { "name": "Underground Disconnect Fuse MV", "code": 570 }, { "name": "Underground Load Break Fuse MV", "code": 571 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV", "code": 572 }, { "name": "Overhead Cutout Load Break Fuse MV - Controller", "code": 573 }, { "name": "Overhead Cutout Disconnect Fuse MV - Controller", "code": 574 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller", "code": 575 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Rating", "description": "List of valid Electric Medium Voltage Fuse Ratingsl", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "C", "code": 1 }, { "name": "E", "code": 2 }, { "name": "R", "code": 3 }, { "name": "PT", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Type", "description": "Medium Voltage fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridged", "code": 1 }, { "name": "Burndy", "code": 2 }, { "name": "Bussman", "code": 3 }, { "name": "Cooper Elf", "code": 4 }, { "name": "D & W", "code": 5 }, { "name": "EJO-1", "code": 6 }, { "name": "Fault Tamer", "code": 7 }, { "name": "Kearney", "code": 8 }, { "name": "Kearney 200", "code": 9 }, { "name": "Kearney QA", "code": 10 }, { "name": "RTE B", "code": 11 }, { "name": "S & C", "code": 12 }, { "name": "S & C SM-4", "code": 13 }, { "name": "X-Limiter", "code": 14 }, { "name": "NX", "code": 15 }, { "name": "CL", "code": 16 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 29, "name": "Medium Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation", "description": "Medium Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "AC Wave MV", "code": 110 }, { "name": "Battery MV", "code": 111 }, { "name": "Biomass MV", "code": 112 }, { "name": "Generator MV", "code": 113 }, { "name": "Gas Turbine MV", "code": 114 }, { "name": "Geothermal MV", "code": 115 }, { "name": "Hydro MV", "code": 116 }, { "name": "Wind MV", "code": 117 }, { "name": "Photovoltaic Solar MV", "code": 118 }, { "name": "Thermal Solar MV", "code": 119 }, { "name": "Interconnect MV", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 30, "name": "Medium Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay", "description": "Medium Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator MV", "code": 601 }, { "name": "Instrument Transformer MV", "code": 602 }, { "name": "Programmable Logic Unit MV", "code": 603 }, { "name": "Remote Terminal Unit MV", "code": 604 }, { "name": "SCADA Load Monitor MV", "code": 605 }, { "name": "SCADA Weather Station MV", "code": 606 }, { "name": "Relay MV", "code": 607 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 31, "name": "Medium Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump", "description": "Medium Voltage Motor and Pump", "codedValues": [ { "name": "Motor and Pump", "code": 0 }, { "name": "Single Phase Motor MV", "code": 621 }, { "name": "Single Phase Pump MV", "code": 622 }, { "name": "Three Phase Motor MV", "code": 623 }, { "name": "Three Phase Pump MV", "code": 624 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 32, "name": "Medium Voltage Motor and Pump" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion", "description": "Medium Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter MV", "code": 641 }, { "name": "Single Phase Rectifier MV", "code": 642 }, { "name": "Three Phase Inverter MV", "code": 643 }, { "name": "Three Phase Rectifier MV", "code": 644 }, { "name": "Single Phase Bidirectional MV", "code": 645 }, { "name": "Three Phase Bidirectional MV", "code": 646 }, { "name": "Wave Trap MV", "code": 647 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 33, "name": "Medium Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting", "description": "Medium Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Mobile Capacitor MV", "code": 661 }, { "name": "Overhead Single Phase Capacitor MV", "code": 664 }, { "name": "Overhead Three Phase Capacitor MV", "code": 665 }, { "name": "Overhead Harmonic Filter MV", "code": 666 }, { "name": "Overhead Reactor MV", "code": 667 }, { "name": "Pad Mounted Single Phase Capacitor MV", "code": 668 }, { "name": "Pad Mounted Three Phase Capacitor MV", "code": 669 }, { "name": "Mobile Harmonic Filter MV", "code": 671 }, { "name": "Mobile Reactor MV", "code": 672 }, { "name": "Pad Mounted Harmonic Filter MV", "code": 673 }, { "name": "Pad Mounted Reactor MV", "code": 674 }, { "name": "Station Capacitor MV", "code": 675 }, { "name": "Station Harmonic Filter MV", "code": 676 }, { "name": "Station Reactor MV", "code": 677 }, { "name": "Synchronous Condenser MV", "code": 678 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 34, "name": "Medium Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator", "description": "Medium Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Overhead Single Phase VR MV", "code": 681 }, { "name": "Overhead Three Phase VR MV", "code": 683 }, { "name": "Pad Mounted Single Phase VR MV", "code": 685 }, { "name": "Pad Mounted Three Phase VR MV", "code": 687 }, { "name": "Frequency Converter MV", "code": 688 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 35, "name": "Medium Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service", "description": "Medium Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Primary Meter - Industrial Customer MV", "code": 701 }, { "name": "Primary Meter - Utility Customer MV", "code": 702 }, { "name": "Primary Meter Circuit Source MV", "code": 703 }, { "name": "Medium Voltage Premise MV", "code": 704 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 36, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser", "description": "Medium Voltage Recloser Asset Types", "codedValues": [ { "name": "Recloser", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Recloser MV", "code": 730 }, { "name": "Overhead Three Phase Recloser MV - Controller", "code": 734 }, { "name": "Pad Mounted Three Phase Recloser MV - Controller", "code": 738 }, { "name": "Overhead Three Phase Recloser MV", "code": 744 }, { "name": "Pad Mounted Single Phase Recloser MV", "code": 747 }, { "name": "Pad Mounted Three Phase Recloser MV", "code": 748 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps", "description": "Medium Voltage Recloser Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "280 A", "code": 280 }, { "name": "400 A", "code": 400 }, { "name": "560 A", "code": 560 }, { "name": "600 A", "code": 600 }, { "name": "630 A", "code": 630 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 41, "name": "Medium Voltage Recloser" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer", "description": "Medium Voltage Secitionalizer", "codedValues": [ { "name": "Sectionalizer", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Sectionalizer MV", "code": 731 }, { "name": "Overhead Three Phase Sectionalizer MV", "code": 745 }, { "name": "Pad Mounted Single Phase Sectionalizer MV", "code": 749 }, { "name": "Pad Mounted Three Phase Sectionalizer MV", "code": 750 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 42, "name": "Medium Voltage Sectionalizer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch", "description": "Medium Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Cabinet Bypass MV", "code": 721 }, { "name": "Cabinet Switch MV", "code": 722 }, { "name": "Cabinet Switch - Grounded MV", "code": 723 }, { "name": "Overhead Bypass MV", "code": 724 }, { "name": "Overhead Grounding Switch MV", "code": 725 }, { "name": "Overhead Jumper MV", "code": 726 }, { "name": "Station Grounding MV", "code": 727 }, { "name": "Overhead Single Phase Disconnect MV", "code": 728 }, { "name": "Overhead Single Phase Load Break MV", "code": 729 }, { "name": "Overhead Three Phase Disconnect MV", "code": 732 }, { "name": "Overhead Three Phase Load Break MV", "code": 733 }, { "name": "Pad Mounted Fault Interrupter MV", "code": 746 }, { "name": "Station Single Phase Disconnect MV", "code": 751 }, { "name": "Station Disconnect MV", "code": 752 }, { "name": "T Blade MV", "code": 753 }, { "name": "V Blade MV", "code": 754 }, { "name": "Underground Single Phase Disconnect MV", "code": 755 }, { "name": "Underground Single Phase Load Break MV", "code": 758 }, { "name": "Underground Three Phase Disconnect MV", "code": 759 }, { "name": "Underground Three Phase Load Break MV", "code": 760 }, { "name": "Underground Transfer Switch MV", "code": 761 }, { "name": "Bus Tie Breaker MV", "code": 765 }, { "name": "Station Load Break MV", "code": 766 }, { "name": "Station Disconnect - Grounded MV", "code": 768 }, { "name": "Station Load Break Disconnect MV", "code": 769 }, { "name": "Station Disconnect MV - Controller", "code": 770 }, { "name": "Station Load Break MV - Controller", "code": 771 }, { "name": "Station Load Break Disconnect MV - Controller", "code": 772 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps", "description": "Medium Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "900 A", "code": 900 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 37, "name": "Medium Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer", "description": "Medium Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Grounding Transformer - MV->MV", "code": 781 }, { "name": "Mobile Single Phase - MV->LV", "code": 782 }, { "name": "Mobile Three Phase - MV->LV", "code": 783 }, { "name": "Network - MV->LV", "code": 784 }, { "name": "Overhead Single Phase - MV->LV", "code": 785 }, { "name": "Station - MV->LV", "code": 786 }, { "name": "Station Three Winding - MV->LV-LV", "code": 787 }, { "name": "Overhead Three Phase - MV->LV", "code": 788 }, { "name": "Pad Mounted Single Phase - MV->LV", "code": 789 }, { "name": "Station Three Winding - MV->MV-LV", "code": 790 }, { "name": "Pad Mounted Three Phase - MV->LV", "code": 792 }, { "name": "Submersible Single Phase - MV->LV", "code": 793 }, { "name": "Submersible Three Phase - MV->LV", "code": 794 }, { "name": "Overhead Open Delta - MV->LV", "code": 795 }, { "name": "Overhead Open Wye - MV->LV", "code": 796 }, { "name": "Pad Mounted Open Delta - MV->LV", "code": 797 }, { "name": "Pad Mounted Open Wye - MV->LV", "code": 798 }, { "name": "Overhead Single Phase Step - MV<->MV", "code": 801 }, { "name": "Overhead Three Phase Step - MV<->MV", "code": 802 }, { "name": "Overhead Single Phase Step - MV->MV", "code": 803 }, { "name": "Overhead Three Phase Step - MV->MV", "code": 804 }, { "name": "Pad Mounted Single Phase Step - MV<->MV", "code": 805 }, { "name": "Pad Mounted Three Phase Step - MV<->MV", "code": 806 }, { "name": "Pad Mounted Single Phase Step - MV->MV", "code": 807 }, { "name": "Pad Mounted Three Phase Step - MV->MV", "code": 808 }, { "name": "Submersible Single Phase Step - MV<->MV", "code": 809 }, { "name": "Overhead Three Phase Wye Delta Closed Ground", "code": 810 }, { "name": "Submersible Single Phase Step - MV->MV", "code": 811 }, { "name": "Pad Mounted Three Phase Wye Delta Closed Ground", "code": 812 }, { "name": "Station Step - MV->MV", "code": 813 }, { "name": "Station Step - MV<->MV", "code": 814 }, { "name": "Station Step Three Winding - MV->MV-MV", "code": 815 }, { "name": "Overhead Three Phase Step Up - LV->MV", "code": 816 }, { "name": "Overhead Three Phase Step Up - LV<->MV", "code": 817 }, { "name": "Station Step Up - LV->MV", "code": 818 }, { "name": "Station Step Up - LV<->MV", "code": 819 }, { "name": "Pad Mounted Three Phase Step Up - LV->MV", "code": 820 }, { "name": "Pad Mounted Three Phase Step Up - LV<->MV", "code": 821 }, { "name": "Overhead Single Phase Step Up - LV->MV", "code": 822 }, { "name": "Overhead Single Phase Step Up - LV<->MV", "code": 823 }, { "name": "Pad Mounted Single Phase Step Up - LV->MV", "code": 824 }, { "name": "Pad Mounted Single Phase Step Up - LV<->MV", "code": 825 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 38, "name": "Medium Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 62, "name": "Medium Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "Transformer Winding MV", "code": 873 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 47, "name": "Medium Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker", "description": "Asset Types for Low Voltage Circuit Breakers", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Circuit Breaker LV", "code": 471 }, { "name": "DC Circuit Breaker LV", "code": 472 }, { "name": "AC Circuit Breaker LV - Controller", "code": 473 }, { "name": "DC Circuit Breaker LV - Controller", "code": 474 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Low Voltage Circuit Breaker Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 40, "name": "Low Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit", "description": "Low Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Control Unit LV", "code": 241 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 13, "name": "Low Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse", "description": "Low Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "Service Fuse Load Break LV", "code": 259 }, { "name": "Service Fuse Disconnect LV", "code": 260 }, { "name": "AC Overhead Fuse LV", "code": 261 }, { "name": "AC Underground Fuse LV", "code": 262 }, { "name": "DC Overhead Fuse LV", "code": 263 }, { "name": "DC Underground Fuse LV", "code": 264 }, { "name": "AC Overhead Load Break Fuse LV", "code": 265 }, { "name": "AC Overhead Fuse LV - Controller", "code": 266 }, { "name": "AC Underground Load Break Fuse LV", "code": 267 }, { "name": "AC Underground Fuse LV - Controller", "code": 268 }, { "name": "DC Overhead Fuse LV - Controller", "code": 269 }, { "name": "DC Underground Fuse LV - Controller", "code": 270 }, { "name": "AC Overhead Cutout Load Break Disconnect Fuse LV", "code": 271 }, { "name": "AC Overhead Cutout Load Break Fuse LV - Controller", "code": 272 }, { "name": "AC Overhead Cutout Disconnect Fuse LV - Controller", "code": 273 }, { "name": "AC Overhead Cutout Load Break Fuse LV", "code": 274 }, { "name": "Station Disconnect Fuse LV", "code": 275 }, { "name": "Station Load Break Fuse LV", "code": 276 }, { "name": "Station Load Break Disconnect Fuse LV", "code": 277 }, { "name": "Station Disconnect Fuse LV - Controller", "code": 278 }, { "name": "Station Load Break Fuse LV - Controller", "code": 279 }, { "name": "Station Load Break Disconnect Fuse LV - Controller", "code": 280 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Type", "description": "List of valid fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Link_Type", "description": "Types of fuse links", "codedValues": [ { "name": "K", "code": 10 }, { "name": "T", "code": 11 }, { "name": "MS", "code": 12 }, { "name": "QH", "code": 13 }, { "name": "Standard", "code": 14 }, { "name": "SloFast", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 14, "name": "Low Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation", "description": "Low Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery LV", "code": 281 }, { "name": "Generator LV", "code": 283 }, { "name": "Residential Photovoltaic Solar LV", "code": 284 }, { "name": "Wind Turbine LV", "code": 285 }, { "name": "AC Wave LV", "code": 286 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 15, "name": "Low Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting", "description": "Low Voltage Lighting", "codedValues": [ { "name": "Lighting", "code": 0 }, { "name": "Floodlight LV", "code": 301 }, { "name": "Streetlight LV", "code": 302 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Light_Housing_Type", "description": "Light Housing Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cobra Head", "code": 1 }, { "name": "Security", "code": 2 }, { "name": "Roadway", "code": 3 }, { "name": "Flood", "code": 4 }, { "name": "Decorative", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Street_Bulb_Type", "description": "List of valid bulb types for streetlights", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High Pressure Sodium (HPS)", "code": 30 }, { "name": "Low Pressure Sodium (LPS)", "code": 31 }, { "name": "Metal Halide (MH)", "code": 32 }, { "name": "Mercury Vapor (MV)", "code": 33 }, { "name": "Halogen (HG)", "code": 34 }, { "name": "Light Emitting Diode (LED)", "code": 35 }, { "name": "Phosphor-Converted Amber LED (PCA)", "code": 36 }, { "name": "Narrow-Band Amber LED (NBA)", "code": 37 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "lightsphotoeye": {"type": "inherited"}, "lightswattage": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 16, "name": "Low Voltage Lighting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay", "description": "Low Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator LV", "code": 321 }, { "name": "Load Monitor LV", "code": 322 }, { "name": "Relay LV", "code": 323 }, { "name": "Instrument Transformer LV", "code": 324 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 17, "name": "Low Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor", "description": "Low Voltage Motor", "codedValues": [ { "name": "Motor", "code": 0 }, { "name": "Single Phase Motor LV", "code": 341 }, { "name": "Three Phase Motor LV", "code": 342 }, { "name": "DC Motor LV", "code": 343 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 18, "name": "Low Voltage Motor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection", "description": "Low Voltage Network Protection", "codedValues": [ { "name": "Network Protector", "code": 0 }, { "name": "Network Protector LV", "code": 361 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 19, "name": "Low Voltage Network Protection" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion", "description": "Low Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter LV", "code": 381 }, { "name": "Single Phase Rectifier LV", "code": 382 }, { "name": "Three Phase Inverter LV", "code": 383 }, { "name": "Three Phase Rectifier LV", "code": 384 }, { "name": "Single Phase Bidirectional LV", "code": 386 }, { "name": "Three Phase Bidirectional LV", "code": 387 }, { "name": "Wave Trap LV", "code": 390 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 20, "name": "Low Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting", "description": "Low Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "Mobile Harmonic Filter LV", "code": 401 }, { "name": "Mobile Reactor LV", "code": 402 }, { "name": "Overhead Capacitor LV", "code": 403 }, { "name": "Overhead Harmonic Filter LV", "code": 404 }, { "name": "Overhead Reactor LV", "code": 405 }, { "name": "Pad Mounted Capacitor LV", "code": 406 }, { "name": "Pad Mounted Harmonic Filter LV", "code": 407 }, { "name": "Pad Mounted Reactor LV", "code": 408 }, { "name": "Station Capacitor LV", "code": 409 }, { "name": "Station Harmonic Filter LV", "code": 410 }, { "name": "Station Reactor LV", "code": 411 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 21, "name": "Low Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service", "description": "Low Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Single Phase Commercial LV", "code": 421 }, { "name": "Single Phase Residential LV", "code": 422 }, { "name": "Three Phase Commercial LV", "code": 423 }, { "name": "Three Phase Residential LV", "code": 424 }, { "name": "Unmetered Load LV", "code": 425 }, { "name": "DC Commercial LV", "code": 426 }, { "name": "Low Voltage Premise LV", "code": 427 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 22, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch", "description": "Low Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Station Disconnect LV", "code": 431 }, { "name": "AC Station Load Break LV", "code": 432 }, { "name": "AC Station Load Break Disconnect LV", "code": 433 }, { "name": "AC Station Disconnect LV - Controller", "code": 434 }, { "name": "AC Station Load Break LV - Controller", "code": 435 }, { "name": "AC Station Load Break Disconnect LV - Controller", "code": 436 }, { "name": "Overhead AC Load Break LV", "code": 441 }, { "name": "Overhead AC Disconnect LV", "code": 442 }, { "name": "Overhead DC Load Break LV", "code": 443 }, { "name": "Overhead DC Disconnect LV", "code": 444 }, { "name": "Underground AC Load Break LV", "code": 445 }, { "name": "Underground AC Disconnect LV", "code": 446 }, { "name": "Underground DC Load Break LV", "code": 447 }, { "name": "Underground DC Disconnect LV", "code": 448 }, { "name": "Indoor AC Load Break LV", "code": 449 }, { "name": "Indoor AC Disconnect LV", "code": 450 }, { "name": "Indoor DC Load Break LV", "code": 451 }, { "name": "Indoor DC Disconnect LV", "code": 452 }, { "name": "Source Selectable Switch LV", "code": 453 }, { "name": "Overhead Jumper LV", "code": 454 }, { "name": "DC Station LV", "code": 456 }, { "name": "AC Station Bypass LV", "code": 457 }, { "name": "AC Recloser LV", "code": 458 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps", "description": "Low Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "45 A", "code": 45 }, { "name": "50 A", "code": 50 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "300 A", "code": 300 }, { "name": "320 A", "code": 320 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 }, { "name": "2500 A", "code": 2500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 23, "name": "Low Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer", "description": "Low Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Single Phase - LV->LV", "code": 461 }, { "name": "Three Phase - LV->LV", "code": 462 }, { "name": "Three Winding - LV->LV-LV", "code": 463 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 24, "name": "Low Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector", "description": "Low Voltage Connectors", "codedValues": [ { "name": "Wire Connector", "code": 0 }, { "name": "Ring Terminal LV", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 44, "name": "Low Voltage Wire Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator", "description": "Asset Types for Low Voltage Regulating Equipment", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase LV", "code": 141 }, { "name": "AC Three Phase LV", "code": 142 }, { "name": "DC Regulator LV", "code": 143 }, { "name": "Network Load Balancer LV", "code": 144 }, { "name": "Frequency Converter LV", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 45, "name": "Low Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding LV", "code": 874 }, { "name": "DC Transformer Winding LV", "code": 875 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 46, "name": "Low Voltage Transformer Winding" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": null, "maintby": null, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Ground", "description": "Ground", "codedValues": [ { "name": "Ground", "code": 0 }, { "name": "Bound", "code": 31 }, { "name": "Rod", "code": 32 }, { "name": "Voltage Grid", "code": 33 }, { "name": "Stray Voltage Isolator", "code": 34 }, { "name": "Grounding Switch", "code": 35 }, { "name": "Cross Bond", "code": 36 }, { "name": "Ground Plate", "code": 37 }, { "name": "Ground Joint", "code": 38 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Ground_Type", "description": "Ground Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bound", "code": 1 }, { "name": "Mesh", "code": 2 }, { "name": "Rod", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 1, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit", "description": "High Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor HV", "code": 41 }, { "name": "Switch and Breaker HV", "code": 42 }, { "name": "Voltage Regulator HV", "code": 43 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 3, "name": "High Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation", "description": "High Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery HV", "code": 61 }, { "name": "Biomass HV", "code": 62 }, { "name": "Coal HV", "code": 63 }, { "name": "Gas Turbine HV", "code": 64 }, { "name": "Geothermal HV", "code": 65 }, { "name": "Hydro HV", "code": 66 }, { "name": "Nuclear HV", "code": 67 }, { "name": "Photovoltaic Solar HV", "code": 68 }, { "name": "Thermal Solar HV", "code": 69 }, { "name": "Wind HV", "code": 70 }, { "name": "AC Wave HV", "code": 71 }, { "name": "Generator HV", "code": 72 }, { "name": "Interconnect HV", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 4, "name": "High Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse", "description": "High Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Station Disconnect Fuse HV", "code": 581 }, { "name": "AC Station Load Break Fuse HV", "code": 582 }, { "name": "AC Load Break Disconnect Fuse HV", "code": 583 }, { "name": "AC Load Break Fuse HV - Controller", "code": 584 }, { "name": "AC Disconnect Fuse HV - Controller", "code": 585 }, { "name": "AC Load Break Disconnect Fuse HV - Controller", "code": 586 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current", "description": "List of valid High Voltage Switching and Protective Maximum Continuous Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "1200 A", "code": 1200 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "3000 A", "code": 3000 }, { "name": "6000 A", "code": 6000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current", "description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "60 kA", "code": 60000 }, { "name": "80 kA", "code": 80000 }, { "name": "90 kA", "code": 90000 }, { "name": "2 kA", "code": 2000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 43, "name": "High Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay", "description": "High Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator HV", "code": 80 }, { "name": "Instrument Transformer HV", "code": 81 }, { "name": "Load Monitor HV", "code": 82 }, { "name": "Relay HV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Phase_Angle_Offset_Range", "description": "Phase Offset values 0 - 60", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 5, "name": "High Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion", "description": "High Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Inverter HV", "code": 101 }, { "name": "Rectifier HV", "code": 102 }, { "name": "Bidirectional HV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_DC_Voltage", "description": "Valid High Voltage Direct Current Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "270 kV", "code": 270000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "500 kV", "code": 500000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1000 kV", "code": 1000000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 }, { "name": "1400 kV", "code": 1400000 }, { "name": "1500 kV", "code": 1500000 }, { "name": "1800 kV", "code": 1800000 }, { "name": "2500 kV", "code": 2500000 }, { "name": "3000 kV", "code": 3000000 }, { "name": "4000 kV", "code": 4000000 }, { "name": "5000 kV", "code": 5000000 }, { "name": "6000 kV", "code": 6000000 }, { "name": "6400 kV", "code": 6400000 }, { "name": "7200 kV", "code": 7200000 }, { "name": "8000 kV", "code": 8000000 }, { "name": "10000 kV", "code": 10000000 }, { "name": "12000 kV", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 6, "name": "High Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting", "description": "High Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Capacitor HV", "code": 121 }, { "name": "AC Wave Trap HV", "code": 122 }, { "name": "AC Reactor HV", "code": 123 }, { "name": "DC Capacitor HV", "code": 124 }, { "name": "DC Reactor HV", "code": 125 }, { "name": "Synchronous Condenser HV", "code": 126 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Power_Factor_Correcting_Type", "description": "Type of Power Factor Correcting Equipment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 7, "name": "High Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator", "description": "High Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase HV", "code": 171 }, { "name": "AC Three Phase HV", "code": 172 }, { "name": "DC Regulator HV", "code": 173 }, { "name": "Frequency Converter HV", "code": 174 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 8, "name": "High Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service", "description": "High Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "AC Metering HV", "code": 161 }, { "name": "DC Metering HV", "code": 162 }, { "name": "High Voltage Premise HV", "code": 163 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 9, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch", "description": "High Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Circuit Breaker HV", "code": 181 }, { "name": "AC Disconnect HV", "code": 182 }, { "name": "AC Switchgear HV", "code": 183 }, { "name": "DC Circuit Breaker HV", "code": 184 }, { "name": "DC Disconnect HV", "code": 185 }, { "name": "DC Switchgear HV", "code": 186 }, { "name": "AC Bus Tie Breaker HV", "code": 187 }, { "name": "DC Bus Tie Breaker HV", "code": 188 }, { "name": "AC Disconnect - Grounded HV", "code": 189 }, { "name": "AC Breaker Bypass HV", "code": 190 }, { "name": "AC Circuit Breaker HV - Controller", "code": 191 }, { "name": "AC Station Disconnect HV", "code": 192 }, { "name": "AC Station Load Break Disconnect HV - Controller", "code": 193 }, { "name": "DC Circuit Breaker HV - Controller", "code": 194 }, { "name": "AC Disconnect HV - Controller", "code": 195 }, { "name": "AC Grounding HV", "code": 196 }, { "name": "AC Thyristor HV", "code": 197 }, { "name": "DC Thyristor HV", "code": 198 }, { "name": "AC Transfer Switch HV", "code": 199 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps", "description": "High Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".6 kA", "code": 600 }, { "name": "1.2 kA", "code": 1200 }, { "name": "1.25 kA", "code": 1250 }, { "name": "1.6 kA", "code": 1600 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 10, "name": "High Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer", "description": "High Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "AC Single Phase - HV->MV", "code": 201 }, { "name": "AC Three Phase - HV->MV", "code": 202 }, { "name": "DC Power - HV->HV", "code": 203 }, { "name": "Grounding Transformer - HV->MV", "code": 204 }, { "name": "Station - HV->MV", "code": 205 }, { "name": "Station Three Winding - HV->HV-HV", "code": 206 }, { "name": "Station Three Winding - HV->HV-MV", "code": 207 }, { "name": "Phase Control - HV->HV", "code": 208 }, { "name": "Station Three Winding - HV->HV-LV", "code": 209 }, { "name": "Station Step Up - MV->HV", "code": 210 }, { "name": "Station Step - HV->HV", "code": 211 }, { "name": "Station Three Winding - HV->MV-MV", "code": 212 }, { "name": "Station Three Winding - HV->MV-LV", "code": 213 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 11, "name": "High Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Line Hardware", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 61, "name": "High Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding HV", "code": 871 }, { "name": "DC Transformer Winding HV", "code": 872 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 48, "name": "High Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker", "description": "Medium Voltage Circuit Breaker", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "Isolator Switch MV", "code": 501 }, { "name": "Single Phase Circuit Breaker MV", "code": 502 }, { "name": "Three Phase Circuit Breaker MV", "code": 503 }, { "name": "Single Phase Circuit Breaker MV - Controller", "code": 512 }, { "name": "Three Phase Circuit Breaker MV - Controller", "code": 513 }, { "name": "Network Protector MV", "code": 515 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Medium Voltage Circuit Breaker Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "1250 A", "code": 1250 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "2500 A", "code": 2500 }, { "name": "3000 A", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 26, "name": "Medium Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit", "description": "Medium Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor MV", "code": 521 }, { "name": "Circuit Breaker MV", "code": 522 }, { "name": "Recloser MV", "code": 523 }, { "name": "Transfer Switch Controller MV", "code": 524 }, { "name": "Regulator MV", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 27, "name": "Medium Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow", "description": "Medium Voltage Elbow", "codedValues": [ { "name": "Elbow", "code": 0 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Load Break Feedthru MV", "code": 541 }, { "name": "Load Break Junction MV", "code": 542 }, { "name": "Single Phase Dead Break MV", "code": 543 }, { "name": "Single Phase Load Break MV", "code": 544 }, { "name": "Three Phase Dead Break MV", "code": 545 }, { "name": "Three Phase Load Break MV", "code": 546 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 28, "name": "Medium Voltage Elbow" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse", "description": "Medium Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Bayonet Fuse MV", "code": 561 }, { "name": "Fault Limiter Fuse MV", "code": 562 }, { "name": "Indoor Fuse MV", "code": 563 }, { "name": "Overhead Cutout Disconnect Fuse MV", "code": 564 }, { "name": "Overhead Cutout Load Break Fuse MV", "code": 565 }, { "name": "Overhead Cutout Sectionalizer Fuse MV", "code": 566 }, { "name": "Overhead Cutout Solid Blade Fuse MV", "code": 567 }, { "name": "Cabinet Fuse MV", "code": 568 }, { "name": "Underground Fuse MV", "code": 569 }, { "name": "Underground Disconnect Fuse MV", "code": 570 }, { "name": "Underground Load Break Fuse MV", "code": 571 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV", "code": 572 }, { "name": "Overhead Cutout Load Break Fuse MV - Controller", "code": 573 }, { "name": "Overhead Cutout Disconnect Fuse MV - Controller", "code": 574 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller", "code": 575 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Rating", "description": "List of valid Electric Medium Voltage Fuse Ratingsl", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "C", "code": 1 }, { "name": "E", "code": 2 }, { "name": "R", "code": 3 }, { "name": "PT", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Type", "description": "Medium Voltage fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridged", "code": 1 }, { "name": "Burndy", "code": 2 }, { "name": "Bussman", "code": 3 }, { "name": "Cooper Elf", "code": 4 }, { "name": "D & W", "code": 5 }, { "name": "EJO-1", "code": 6 }, { "name": "Fault Tamer", "code": 7 }, { "name": "Kearney", "code": 8 }, { "name": "Kearney 200", "code": 9 }, { "name": "Kearney QA", "code": 10 }, { "name": "RTE B", "code": 11 }, { "name": "S & C", "code": 12 }, { "name": "S & C SM-4", "code": 13 }, { "name": "X-Limiter", "code": 14 }, { "name": "NX", "code": 15 }, { "name": "CL", "code": 16 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 29, "name": "Medium Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation", "description": "Medium Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "AC Wave MV", "code": 110 }, { "name": "Battery MV", "code": 111 }, { "name": "Biomass MV", "code": 112 }, { "name": "Generator MV", "code": 113 }, { "name": "Gas Turbine MV", "code": 114 }, { "name": "Geothermal MV", "code": 115 }, { "name": "Hydro MV", "code": 116 }, { "name": "Wind MV", "code": 117 }, { "name": "Photovoltaic Solar MV", "code": 118 }, { "name": "Thermal Solar MV", "code": 119 }, { "name": "Interconnect MV", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 30, "name": "Medium Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay", "description": "Medium Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator MV", "code": 601 }, { "name": "Instrument Transformer MV", "code": 602 }, { "name": "Programmable Logic Unit MV", "code": 603 }, { "name": "Remote Terminal Unit MV", "code": 604 }, { "name": "SCADA Load Monitor MV", "code": 605 }, { "name": "SCADA Weather Station MV", "code": 606 }, { "name": "Relay MV", "code": 607 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 31, "name": "Medium Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump", "description": "Medium Voltage Motor and Pump", "codedValues": [ { "name": "Motor and Pump", "code": 0 }, { "name": "Single Phase Motor MV", "code": 621 }, { "name": "Single Phase Pump MV", "code": 622 }, { "name": "Three Phase Motor MV", "code": 623 }, { "name": "Three Phase Pump MV", "code": 624 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 32, "name": "Medium Voltage Motor and Pump" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion", "description": "Medium Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter MV", "code": 641 }, { "name": "Single Phase Rectifier MV", "code": 642 }, { "name": "Three Phase Inverter MV", "code": 643 }, { "name": "Three Phase Rectifier MV", "code": 644 }, { "name": "Single Phase Bidirectional MV", "code": 645 }, { "name": "Three Phase Bidirectional MV", "code": 646 }, { "name": "Wave Trap MV", "code": 647 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 33, "name": "Medium Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting", "description": "Medium Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Mobile Capacitor MV", "code": 661 }, { "name": "Overhead Single Phase Capacitor MV", "code": 664 }, { "name": "Overhead Three Phase Capacitor MV", "code": 665 }, { "name": "Overhead Harmonic Filter MV", "code": 666 }, { "name": "Overhead Reactor MV", "code": 667 }, { "name": "Pad Mounted Single Phase Capacitor MV", "code": 668 }, { "name": "Pad Mounted Three Phase Capacitor MV", "code": 669 }, { "name": "Mobile Harmonic Filter MV", "code": 671 }, { "name": "Mobile Reactor MV", "code": 672 }, { "name": "Pad Mounted Harmonic Filter MV", "code": 673 }, { "name": "Pad Mounted Reactor MV", "code": 674 }, { "name": "Station Capacitor MV", "code": 675 }, { "name": "Station Harmonic Filter MV", "code": 676 }, { "name": "Station Reactor MV", "code": 677 }, { "name": "Synchronous Condenser MV", "code": 678 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 34, "name": "Medium Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator", "description": "Medium Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Overhead Single Phase VR MV", "code": 681 }, { "name": "Overhead Three Phase VR MV", "code": 683 }, { "name": "Pad Mounted Single Phase VR MV", "code": 685 }, { "name": "Pad Mounted Three Phase VR MV", "code": 687 }, { "name": "Frequency Converter MV", "code": 688 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 35, "name": "Medium Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service", "description": "Medium Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Primary Meter - Industrial Customer MV", "code": 701 }, { "name": "Primary Meter - Utility Customer MV", "code": 702 }, { "name": "Primary Meter Circuit Source MV", "code": 703 }, { "name": "Medium Voltage Premise MV", "code": 704 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 36, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser", "description": "Medium Voltage Recloser Asset Types", "codedValues": [ { "name": "Recloser", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Recloser MV", "code": 730 }, { "name": "Overhead Three Phase Recloser MV - Controller", "code": 734 }, { "name": "Pad Mounted Three Phase Recloser MV - Controller", "code": 738 }, { "name": "Overhead Three Phase Recloser MV", "code": 744 }, { "name": "Pad Mounted Single Phase Recloser MV", "code": 747 }, { "name": "Pad Mounted Three Phase Recloser MV", "code": 748 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps", "description": "Medium Voltage Recloser Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "280 A", "code": 280 }, { "name": "400 A", "code": 400 }, { "name": "560 A", "code": 560 }, { "name": "600 A", "code": 600 }, { "name": "630 A", "code": 630 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 41, "name": "Medium Voltage Recloser" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer", "description": "Medium Voltage Secitionalizer", "codedValues": [ { "name": "Sectionalizer", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Sectionalizer MV", "code": 731 }, { "name": "Overhead Three Phase Sectionalizer MV", "code": 745 }, { "name": "Pad Mounted Single Phase Sectionalizer MV", "code": 749 }, { "name": "Pad Mounted Three Phase Sectionalizer MV", "code": 750 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 42, "name": "Medium Voltage Sectionalizer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch", "description": "Medium Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Cabinet Bypass MV", "code": 721 }, { "name": "Cabinet Switch MV", "code": 722 }, { "name": "Cabinet Switch - Grounded MV", "code": 723 }, { "name": "Overhead Bypass MV", "code": 724 }, { "name": "Overhead Grounding Switch MV", "code": 725 }, { "name": "Overhead Jumper MV", "code": 726 }, { "name": "Station Grounding MV", "code": 727 }, { "name": "Overhead Single Phase Disconnect MV", "code": 728 }, { "name": "Overhead Single Phase Load Break MV", "code": 729 }, { "name": "Overhead Three Phase Disconnect MV", "code": 732 }, { "name": "Overhead Three Phase Load Break MV", "code": 733 }, { "name": "Pad Mounted Fault Interrupter MV", "code": 746 }, { "name": "Station Single Phase Disconnect MV", "code": 751 }, { "name": "Station Disconnect MV", "code": 752 }, { "name": "T Blade MV", "code": 753 }, { "name": "V Blade MV", "code": 754 }, { "name": "Underground Single Phase Disconnect MV", "code": 755 }, { "name": "Underground Single Phase Load Break MV", "code": 758 }, { "name": "Underground Three Phase Disconnect MV", "code": 759 }, { "name": "Underground Three Phase Load Break MV", "code": 760 }, { "name": "Underground Transfer Switch MV", "code": 761 }, { "name": "Bus Tie Breaker MV", "code": 765 }, { "name": "Station Load Break MV", "code": 766 }, { "name": "Station Disconnect - Grounded MV", "code": 768 }, { "name": "Station Load Break Disconnect MV", "code": 769 }, { "name": "Station Disconnect MV - Controller", "code": 770 }, { "name": "Station Load Break MV - Controller", "code": 771 }, { "name": "Station Load Break Disconnect MV - Controller", "code": 772 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps", "description": "Medium Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "900 A", "code": 900 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12000, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 37, "name": "Medium Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer", "description": "Medium Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Grounding Transformer - MV->MV", "code": 781 }, { "name": "Mobile Single Phase - MV->LV", "code": 782 }, { "name": "Mobile Three Phase - MV->LV", "code": 783 }, { "name": "Network - MV->LV", "code": 784 }, { "name": "Overhead Single Phase - MV->LV", "code": 785 }, { "name": "Station - MV->LV", "code": 786 }, { "name": "Station Three Winding - MV->LV-LV", "code": 787 }, { "name": "Overhead Three Phase - MV->LV", "code": 788 }, { "name": "Pad Mounted Single Phase - MV->LV", "code": 789 }, { "name": "Station Three Winding - MV->MV-LV", "code": 790 }, { "name": "Pad Mounted Three Phase - MV->LV", "code": 792 }, { "name": "Submersible Single Phase - MV->LV", "code": 793 }, { "name": "Submersible Three Phase - MV->LV", "code": 794 }, { "name": "Overhead Open Delta - MV->LV", "code": 795 }, { "name": "Overhead Open Wye - MV->LV", "code": 796 }, { "name": "Pad Mounted Open Delta - MV->LV", "code": 797 }, { "name": "Pad Mounted Open Wye - MV->LV", "code": 798 }, { "name": "Overhead Single Phase Step - MV<->MV", "code": 801 }, { "name": "Overhead Three Phase Step - MV<->MV", "code": 802 }, { "name": "Overhead Single Phase Step - MV->MV", "code": 803 }, { "name": "Overhead Three Phase Step - MV->MV", "code": 804 }, { "name": "Pad Mounted Single Phase Step - MV<->MV", "code": 805 }, { "name": "Pad Mounted Three Phase Step - MV<->MV", "code": 806 }, { "name": "Pad Mounted Single Phase Step - MV->MV", "code": 807 }, { "name": "Pad Mounted Three Phase Step - MV->MV", "code": 808 }, { "name": "Submersible Single Phase Step - MV<->MV", "code": 809 }, { "name": "Overhead Three Phase Wye Delta Closed Ground", "code": 810 }, { "name": "Submersible Single Phase Step - MV->MV", "code": 811 }, { "name": "Pad Mounted Three Phase Wye Delta Closed Ground", "code": 812 }, { "name": "Station Step - MV->MV", "code": 813 }, { "name": "Station Step - MV<->MV", "code": 814 }, { "name": "Station Step Three Winding - MV->MV-MV", "code": 815 }, { "name": "Overhead Three Phase Step Up - LV->MV", "code": 816 }, { "name": "Overhead Three Phase Step Up - LV<->MV", "code": 817 }, { "name": "Station Step Up - LV->MV", "code": 818 }, { "name": "Station Step Up - LV<->MV", "code": 819 }, { "name": "Pad Mounted Three Phase Step Up - LV->MV", "code": 820 }, { "name": "Pad Mounted Three Phase Step Up - LV<->MV", "code": 821 }, { "name": "Overhead Single Phase Step Up - LV->MV", "code": 822 }, { "name": "Overhead Single Phase Step Up - LV<->MV", "code": 823 }, { "name": "Pad Mounted Single Phase Step Up - LV->MV", "code": 824 }, { "name": "Pad Mounted Single Phase Step Up - LV<->MV", "code": 825 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": "_CENTERTAPLOADMIX", "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 38, "name": "Medium Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 62, "name": "Medium Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "Transformer Winding MV", "code": 873 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 47, "name": "Medium Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker", "description": "Asset Types for Low Voltage Circuit Breakers", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Circuit Breaker LV", "code": 471 }, { "name": "DC Circuit Breaker LV", "code": 472 }, { "name": "AC Circuit Breaker LV - Controller", "code": 473 }, { "name": "DC Circuit Breaker LV - Controller", "code": 474 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Low Voltage Circuit Breaker Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 40, "name": "Low Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit", "description": "Low Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Control Unit LV", "code": 241 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 13, "name": "Low Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse", "description": "Low Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "Service Fuse Load Break LV", "code": 259 }, { "name": "Service Fuse Disconnect LV", "code": 260 }, { "name": "AC Overhead Fuse LV", "code": 261 }, { "name": "AC Underground Fuse LV", "code": 262 }, { "name": "DC Overhead Fuse LV", "code": 263 }, { "name": "DC Underground Fuse LV", "code": 264 }, { "name": "AC Overhead Load Break Fuse LV", "code": 265 }, { "name": "AC Overhead Fuse LV - Controller", "code": 266 }, { "name": "AC Underground Load Break Fuse LV", "code": 267 }, { "name": "AC Underground Fuse LV - Controller", "code": 268 }, { "name": "DC Overhead Fuse LV - Controller", "code": 269 }, { "name": "DC Underground Fuse LV - Controller", "code": 270 }, { "name": "AC Overhead Cutout Load Break Disconnect Fuse LV", "code": 271 }, { "name": "AC Overhead Cutout Load Break Fuse LV - Controller", "code": 272 }, { "name": "AC Overhead Cutout Disconnect Fuse LV - Controller", "code": 273 }, { "name": "AC Overhead Cutout Load Break Fuse LV", "code": 274 }, { "name": "Station Disconnect Fuse LV", "code": 275 }, { "name": "Station Load Break Fuse LV", "code": 276 }, { "name": "Station Load Break Disconnect Fuse LV", "code": 277 }, { "name": "Station Disconnect Fuse LV - Controller", "code": 278 }, { "name": "Station Load Break Fuse LV - Controller", "code": 279 }, { "name": "Station Load Break Disconnect Fuse LV - Controller", "code": 280 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Type", "description": "List of valid fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Link_Type", "description": "Types of fuse links", "codedValues": [ { "name": "K", "code": 10 }, { "name": "T", "code": 11 }, { "name": "MS", "code": 12 }, { "name": "QH", "code": 13 }, { "name": "Standard", "code": 14 }, { "name": "SloFast", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 14, "name": "Low Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation", "description": "Low Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery LV", "code": 281 }, { "name": "Generator LV", "code": 283 }, { "name": "Residential Photovoltaic Solar LV", "code": 284 }, { "name": "Wind Turbine LV", "code": 285 }, { "name": "AC Wave LV", "code": 286 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 15, "name": "Low Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting", "description": "Low Voltage Lighting", "codedValues": [ { "name": "Lighting", "code": 0 }, { "name": "Floodlight LV", "code": 301 }, { "name": "Streetlight LV", "code": 302 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Light_Housing_Type", "description": "Light Housing Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cobra Head", "code": 1 }, { "name": "Security", "code": 2 }, { "name": "Roadway", "code": 3 }, { "name": "Flood", "code": 4 }, { "name": "Decorative", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Street_Bulb_Type", "description": "List of valid bulb types for streetlights", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High Pressure Sodium (HPS)", "code": 30 }, { "name": "Low Pressure Sodium (LPS)", "code": 31 }, { "name": "Metal Halide (MH)", "code": 32 }, { "name": "Mercury Vapor (MV)", "code": 33 }, { "name": "Halogen (HG)", "code": 34 }, { "name": "Light Emitting Diode (LED)", "code": 35 }, { "name": "Phosphor-Converted Amber LED (PCA)", "code": 36 }, { "name": "Narrow-Band Amber LED (NBA)", "code": 37 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "lightsphotoeye": {"type": "inherited"}, "lightswattage": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 16, "name": "Low Voltage Lighting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay", "description": "Low Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator LV", "code": 321 }, { "name": "Load Monitor LV", "code": 322 }, { "name": "Relay LV", "code": 323 }, { "name": "Instrument Transformer LV", "code": 324 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 17, "name": "Low Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor", "description": "Low Voltage Motor", "codedValues": [ { "name": "Motor", "code": 0 }, { "name": "Single Phase Motor LV", "code": 341 }, { "name": "Three Phase Motor LV", "code": 342 }, { "name": "DC Motor LV", "code": 343 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 18, "name": "Low Voltage Motor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection", "description": "Low Voltage Network Protection", "codedValues": [ { "name": "Network Protector", "code": 0 }, { "name": "Network Protector LV", "code": 361 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 19, "name": "Low Voltage Network Protection" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion", "description": "Low Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter LV", "code": 381 }, { "name": "Single Phase Rectifier LV", "code": 382 }, { "name": "Three Phase Inverter LV", "code": 383 }, { "name": "Three Phase Rectifier LV", "code": 384 }, { "name": "Single Phase Bidirectional LV", "code": 386 }, { "name": "Three Phase Bidirectional LV", "code": 387 }, { "name": "Wave Trap LV", "code": 390 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 20, "name": "Low Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting", "description": "Low Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "Mobile Harmonic Filter LV", "code": 401 }, { "name": "Mobile Reactor LV", "code": 402 }, { "name": "Overhead Capacitor LV", "code": 403 }, { "name": "Overhead Harmonic Filter LV", "code": 404 }, { "name": "Overhead Reactor LV", "code": 405 }, { "name": "Pad Mounted Capacitor LV", "code": 406 }, { "name": "Pad Mounted Harmonic Filter LV", "code": 407 }, { "name": "Pad Mounted Reactor LV", "code": 408 }, { "name": "Station Capacitor LV", "code": 409 }, { "name": "Station Harmonic Filter LV", "code": 410 }, { "name": "Station Reactor LV", "code": 411 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 21, "name": "Low Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service", "description": "Low Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Single Phase Commercial LV", "code": 421 }, { "name": "Single Phase Residential LV", "code": 422 }, { "name": "Three Phase Commercial LV", "code": 423 }, { "name": "Three Phase Residential LV", "code": 424 }, { "name": "Unmetered Load LV", "code": 425 }, { "name": "DC Commercial LV", "code": 426 }, { "name": "Low Voltage Premise LV", "code": 427 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": "_CENTERTAPLOADMIX", "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 22, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch", "description": "Low Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Station Disconnect LV", "code": 431 }, { "name": "AC Station Load Break LV", "code": 432 }, { "name": "AC Station Load Break Disconnect LV", "code": 433 }, { "name": "AC Station Disconnect LV - Controller", "code": 434 }, { "name": "AC Station Load Break LV - Controller", "code": 435 }, { "name": "AC Station Load Break Disconnect LV - Controller", "code": 436 }, { "name": "Overhead AC Load Break LV", "code": 441 }, { "name": "Overhead AC Disconnect LV", "code": 442 }, { "name": "Overhead DC Load Break LV", "code": 443 }, { "name": "Overhead DC Disconnect LV", "code": 444 }, { "name": "Underground AC Load Break LV", "code": 445 }, { "name": "Underground AC Disconnect LV", "code": 446 }, { "name": "Underground DC Load Break LV", "code": 447 }, { "name": "Underground DC Disconnect LV", "code": 448 }, { "name": "Indoor AC Load Break LV", "code": 449 }, { "name": "Indoor AC Disconnect LV", "code": 450 }, { "name": "Indoor DC Load Break LV", "code": 451 }, { "name": "Indoor DC Disconnect LV", "code": 452 }, { "name": "Source Selectable Switch LV", "code": 453 }, { "name": "Overhead Jumper LV", "code": 454 }, { "name": "DC Station LV", "code": 456 }, { "name": "AC Station Bypass LV", "code": 457 }, { "name": "AC Recloser LV", "code": 458 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps", "description": "Low Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "45 A", "code": 45 }, { "name": "50 A", "code": 50 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "300 A", "code": 300 }, { "name": "320 A", "code": 320 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 }, { "name": "2500 A", "code": 2500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 23, "name": "Low Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer", "description": "Low Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Single Phase - LV->LV", "code": 461 }, { "name": "Three Phase - LV->LV", "code": 462 }, { "name": "Three Winding - LV->LV-LV", "code": 463 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 24, "name": "Low Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector", "description": "Low Voltage Connectors", "codedValues": [ { "name": "Wire Connector", "code": 0 }, { "name": "Ring Terminal LV", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 44, "name": "Low Voltage Wire Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator", "description": "Asset Types for Low Voltage Regulating Equipment", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase LV", "code": 141 }, { "name": "AC Three Phase LV", "code": 142 }, { "name": "DC Regulator LV", "code": 143 }, { "name": "Network Load Balancer LV", "code": 144 }, { "name": "Frequency Converter LV", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 45, "name": "Low Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding LV", "code": 874 }, { "name": "DC Transformer Winding LV", "code": 875 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 46, "name": "Low Voltage Transformer Winding" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1757937024000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 420, "name": "Streetlight", "type": "Feature Layer", "description": "

These are features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 400, "name": "Electric" }, "subLayers": [], "minScale": 2000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriPMS", "url": "8709531302979b3aa502d12e7659f144", "imageData": "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", "contentType": "image/png", "width": 15, "height": 15, "angle": 0, "xoffset": 0, "yoffset": 0 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 643690.5494070798, "ymin": 639234.0107380748, "xmax": 707061.4210246615, "ymax": 688815.7550783232, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "assetgroup", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "WS1_Lifecycle_Status_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Proposed and In Service", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "In Service and Planned Removal", "code": 6 }, { "name": "Maintenance", "code": 7 }, { "name": "Design", "code": 11 }, { "name": "Abandoned", "code": 12 }, { "name": "Removed", "code": 13 }, { "name": "Retired", "code": 14 }, { "name": "NA", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S182_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Ground", "description": "Ground", "codedValues": [ { "name": "Ground", "code": 0 }, { "name": "Bound", "code": 31 }, { "name": "Rod", "code": 32 }, { "name": "Voltage Grid", "code": 33 }, { "name": "Stray Voltage Isolator", "code": 34 }, { "name": "Grounding Switch", "code": 35 }, { "name": "Cross Bond", "code": 36 }, { "name": "Ground Plate", "code": 37 }, { "name": "Ground Joint", "code": 38 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Ground_Type", "description": "Ground Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bound", "code": 1 }, { "name": "Mesh", "code": 2 }, { "name": "Rod", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 1, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit", "description": "High Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor HV", "code": 41 }, { "name": "Switch and Breaker HV", "code": 42 }, { "name": "Voltage Regulator HV", "code": 43 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 3, "name": "High Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation", "description": "High Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery HV", "code": 61 }, { "name": "Biomass HV", "code": 62 }, { "name": "Coal HV", "code": 63 }, { "name": "Gas Turbine HV", "code": 64 }, { "name": "Geothermal HV", "code": 65 }, { "name": "Hydro HV", "code": 66 }, { "name": "Nuclear HV", "code": 67 }, { "name": "Photovoltaic Solar HV", "code": 68 }, { "name": "Thermal Solar HV", "code": 69 }, { "name": "Wind HV", "code": 70 }, { "name": "AC Wave HV", "code": 71 }, { "name": "Generator HV", "code": 72 }, { "name": "Interconnect HV", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 4, "name": "High Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse", "description": "High Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Station Disconnect Fuse HV", "code": 581 }, { "name": "AC Station Load Break Fuse HV", "code": 582 }, { "name": "AC Load Break Disconnect Fuse HV", "code": 583 }, { "name": "AC Load Break Fuse HV - Controller", "code": 584 }, { "name": "AC Disconnect Fuse HV - Controller", "code": 585 }, { "name": "AC Load Break Disconnect Fuse HV - Controller", "code": 586 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current", "description": "List of valid High Voltage Switching and Protective Maximum Continuous Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "1200 A", "code": 1200 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "3000 A", "code": 3000 }, { "name": "6000 A", "code": 6000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current", "description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "60 kA", "code": 60000 }, { "name": "80 kA", "code": 80000 }, { "name": "90 kA", "code": 90000 }, { "name": "2 kA", "code": 2000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 43, "name": "High Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay", "description": "High Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator HV", "code": 80 }, { "name": "Instrument Transformer HV", "code": 81 }, { "name": "Load Monitor HV", "code": 82 }, { "name": "Relay HV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Phase_Angle_Offset_Range", "description": "Phase Offset values 0 - 60", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 5, "name": "High Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion", "description": "High Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Inverter HV", "code": 101 }, { "name": "Rectifier HV", "code": 102 }, { "name": "Bidirectional HV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_DC_Voltage", "description": "Valid High Voltage Direct Current Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "270 kV", "code": 270000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "500 kV", "code": 500000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1000 kV", "code": 1000000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 }, { "name": "1400 kV", "code": 1400000 }, { "name": "1500 kV", "code": 1500000 }, { "name": "1800 kV", "code": 1800000 }, { "name": "2500 kV", "code": 2500000 }, { "name": "3000 kV", "code": 3000000 }, { "name": "4000 kV", "code": 4000000 }, { "name": "5000 kV", "code": 5000000 }, { "name": "6000 kV", "code": 6000000 }, { "name": "6400 kV", "code": 6400000 }, { "name": "7200 kV", "code": 7200000 }, { "name": "8000 kV", "code": 8000000 }, { "name": "10000 kV", "code": 10000000 }, { "name": "12000 kV", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 6, "name": "High Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting", "description": "High Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Capacitor HV", "code": 121 }, { "name": "AC Wave Trap HV", "code": 122 }, { "name": "AC Reactor HV", "code": 123 }, { "name": "DC Capacitor HV", "code": 124 }, { "name": "DC Reactor HV", "code": 125 }, { "name": "Synchronous Condenser HV", "code": 126 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Power_Factor_Correcting_Type", "description": "Type of Power Factor Correcting Equipment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 7, "name": "High Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator", "description": "High Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase HV", "code": 171 }, { "name": "AC Three Phase HV", "code": 172 }, { "name": "DC Regulator HV", "code": 173 }, { "name": "Frequency Converter HV", "code": 174 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 8, "name": "High Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service", "description": "High Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "AC Metering HV", "code": 161 }, { "name": "DC Metering HV", "code": 162 }, { "name": "High Voltage Premise HV", "code": 163 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 9, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch", "description": "High Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Circuit Breaker HV", "code": 181 }, { "name": "AC Disconnect HV", "code": 182 }, { "name": "AC Switchgear HV", "code": 183 }, { "name": "DC Circuit Breaker HV", "code": 184 }, { "name": "DC Disconnect HV", "code": 185 }, { "name": "DC Switchgear HV", "code": 186 }, { "name": "AC Bus Tie Breaker HV", "code": 187 }, { "name": "DC Bus Tie Breaker HV", "code": 188 }, { "name": "AC Disconnect - Grounded HV", "code": 189 }, { "name": "AC Breaker Bypass HV", "code": 190 }, { "name": "AC Circuit Breaker HV - Controller", "code": 191 }, { "name": "AC Station Disconnect HV", "code": 192 }, { "name": "AC Station Load Break Disconnect HV - Controller", "code": 193 }, { "name": "DC Circuit Breaker HV - Controller", "code": 194 }, { "name": "AC Disconnect HV - Controller", "code": 195 }, { "name": "AC Grounding HV", "code": 196 }, { "name": "AC Thyristor HV", "code": 197 }, { "name": "DC Thyristor HV", "code": 198 }, { "name": "AC Transfer Switch HV", "code": 199 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps", "description": "High Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".6 kA", "code": 600 }, { "name": "1.2 kA", "code": 1200 }, { "name": "1.25 kA", "code": 1250 }, { "name": "1.6 kA", "code": 1600 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 10, "name": "High Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer", "description": "High Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "AC Single Phase - HV->MV", "code": 201 }, { "name": "AC Three Phase - HV->MV", "code": 202 }, { "name": "DC Power - HV->HV", "code": 203 }, { "name": "Grounding Transformer - HV->MV", "code": 204 }, { "name": "Station - HV->MV", "code": 205 }, { "name": "Station Three Winding - HV->HV-HV", "code": 206 }, { "name": "Station Three Winding - HV->HV-MV", "code": 207 }, { "name": "Phase Control - HV->HV", "code": 208 }, { "name": "Station Three Winding - HV->HV-LV", "code": 209 }, { "name": "Station Step Up - MV->HV", "code": 210 }, { "name": "Station Step - HV->HV", "code": 211 }, { "name": "Station Three Winding - HV->MV-MV", "code": 212 }, { "name": "Station Three Winding - HV->MV-LV", "code": 213 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 11, "name": "High Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Line Hardware", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 61, "name": "High Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding HV", "code": 871 }, { "name": "DC Transformer Winding HV", "code": 872 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 48, "name": "High Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker", "description": "Medium Voltage Circuit Breaker", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "Isolator Switch MV", "code": 501 }, { "name": "Single Phase Circuit Breaker MV", "code": 502 }, { "name": "Three Phase Circuit Breaker MV", "code": 503 }, { "name": "Single Phase Circuit Breaker MV - Controller", "code": 512 }, { "name": "Three Phase Circuit Breaker MV - Controller", "code": 513 }, { "name": "Network Protector MV", "code": 515 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Medium Voltage Circuit Breaker Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "1250 A", "code": 1250 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "2500 A", "code": 2500 }, { "name": "3000 A", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 26, "name": "Medium Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit", "description": "Medium Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor MV", "code": 521 }, { "name": "Circuit Breaker MV", "code": 522 }, { "name": "Recloser MV", "code": 523 }, { "name": "Transfer Switch Controller MV", "code": 524 }, { "name": "Regulator MV", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 27, "name": "Medium Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow", "description": "Medium Voltage Elbow", "codedValues": [ { "name": "Elbow", "code": 0 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Load Break Feedthru MV", "code": 541 }, { "name": "Load Break Junction MV", "code": 542 }, { "name": "Single Phase Dead Break MV", "code": 543 }, { "name": "Single Phase Load Break MV", "code": 544 }, { "name": "Three Phase Dead Break MV", "code": 545 }, { "name": "Three Phase Load Break MV", "code": 546 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 28, "name": "Medium Voltage Elbow" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse", "description": "Medium Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Bayonet Fuse MV", "code": 561 }, { "name": "Fault Limiter Fuse MV", "code": 562 }, { "name": "Indoor Fuse MV", "code": 563 }, { "name": "Overhead Cutout Disconnect Fuse MV", "code": 564 }, { "name": "Overhead Cutout Load Break Fuse MV", "code": 565 }, { "name": "Overhead Cutout Sectionalizer Fuse MV", "code": 566 }, { "name": "Overhead Cutout Solid Blade Fuse MV", "code": 567 }, { "name": "Cabinet Fuse MV", "code": 568 }, { "name": "Underground Fuse MV", "code": 569 }, { "name": "Underground Disconnect Fuse MV", "code": 570 }, { "name": "Underground Load Break Fuse MV", "code": 571 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV", "code": 572 }, { "name": "Overhead Cutout Load Break Fuse MV - Controller", "code": 573 }, { "name": "Overhead Cutout Disconnect Fuse MV - Controller", "code": 574 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller", "code": 575 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Rating", "description": "List of valid Electric Medium Voltage Fuse Ratingsl", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "C", "code": 1 }, { "name": "E", "code": 2 }, { "name": "R", "code": 3 }, { "name": "PT", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Type", "description": "Medium Voltage fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridged", "code": 1 }, { "name": "Burndy", "code": 2 }, { "name": "Bussman", "code": 3 }, { "name": "Cooper Elf", "code": 4 }, { "name": "D & W", "code": 5 }, { "name": "EJO-1", "code": 6 }, { "name": "Fault Tamer", "code": 7 }, { "name": "Kearney", "code": 8 }, { "name": "Kearney 200", "code": 9 }, { "name": "Kearney QA", "code": 10 }, { "name": "RTE B", "code": 11 }, { "name": "S & C", "code": 12 }, { "name": "S & C SM-4", "code": 13 }, { "name": "X-Limiter", "code": 14 }, { "name": "NX", "code": 15 }, { "name": "CL", "code": 16 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 29, "name": "Medium Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation", "description": "Medium Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "AC Wave MV", "code": 110 }, { "name": "Battery MV", "code": 111 }, { "name": "Biomass MV", "code": 112 }, { "name": "Generator MV", "code": 113 }, { "name": "Gas Turbine MV", "code": 114 }, { "name": "Geothermal MV", "code": 115 }, { "name": "Hydro MV", "code": 116 }, { "name": "Wind MV", "code": 117 }, { "name": "Photovoltaic Solar MV", "code": 118 }, { "name": "Thermal Solar MV", "code": 119 }, { "name": "Interconnect MV", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 30, "name": "Medium Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay", "description": "Medium Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator MV", "code": 601 }, { "name": "Instrument Transformer MV", "code": 602 }, { "name": "Programmable Logic Unit MV", "code": 603 }, { "name": "Remote Terminal Unit MV", "code": 604 }, { "name": "SCADA Load Monitor MV", "code": 605 }, { "name": "SCADA Weather Station MV", "code": 606 }, { "name": "Relay MV", "code": 607 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 31, "name": "Medium Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump", "description": "Medium Voltage Motor and Pump", "codedValues": [ { "name": "Motor and Pump", "code": 0 }, { "name": "Single Phase Motor MV", "code": 621 }, { "name": "Single Phase Pump MV", "code": 622 }, { "name": "Three Phase Motor MV", "code": 623 }, { "name": "Three Phase Pump MV", "code": 624 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 32, "name": "Medium Voltage Motor and Pump" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion", "description": "Medium Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter MV", "code": 641 }, { "name": "Single Phase Rectifier MV", "code": 642 }, { "name": "Three Phase Inverter MV", "code": 643 }, { "name": "Three Phase Rectifier MV", "code": 644 }, { "name": "Single Phase Bidirectional MV", "code": 645 }, { "name": "Three Phase Bidirectional MV", "code": 646 }, { "name": "Wave Trap MV", "code": 647 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 33, "name": "Medium Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting", "description": "Medium Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Mobile Capacitor MV", "code": 661 }, { "name": "Overhead Single Phase Capacitor MV", "code": 664 }, { "name": "Overhead Three Phase Capacitor MV", "code": 665 }, { "name": "Overhead Harmonic Filter MV", "code": 666 }, { "name": "Overhead Reactor MV", "code": 667 }, { "name": "Pad Mounted Single Phase Capacitor MV", "code": 668 }, { "name": "Pad Mounted Three Phase Capacitor MV", "code": 669 }, { "name": "Mobile Harmonic Filter MV", "code": 671 }, { "name": "Mobile Reactor MV", "code": 672 }, { "name": "Pad Mounted Harmonic Filter MV", "code": 673 }, { "name": "Pad Mounted Reactor MV", "code": 674 }, { "name": "Station Capacitor MV", "code": 675 }, { "name": "Station Harmonic Filter MV", "code": 676 }, { "name": "Station Reactor MV", "code": 677 }, { "name": "Synchronous Condenser MV", "code": 678 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 34, "name": "Medium Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator", "description": "Medium Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Overhead Single Phase VR MV", "code": 681 }, { "name": "Overhead Three Phase VR MV", "code": 683 }, { "name": "Pad Mounted Single Phase VR MV", "code": 685 }, { "name": "Pad Mounted Three Phase VR MV", "code": 687 }, { "name": "Frequency Converter MV", "code": 688 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 35, "name": "Medium Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service", "description": "Medium Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Primary Meter - Industrial Customer MV", "code": 701 }, { "name": "Primary Meter - Utility Customer MV", "code": 702 }, { "name": "Primary Meter Circuit Source MV", "code": 703 }, { "name": "Medium Voltage Premise MV", "code": 704 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 36, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser", "description": "Medium Voltage Recloser Asset Types", "codedValues": [ { "name": "Recloser", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Recloser MV", "code": 730 }, { "name": "Overhead Three Phase Recloser MV - Controller", "code": 734 }, { "name": "Pad Mounted Three Phase Recloser MV - Controller", "code": 738 }, { "name": "Overhead Three Phase Recloser MV", "code": 744 }, { "name": "Pad Mounted Single Phase Recloser MV", "code": 747 }, { "name": "Pad Mounted Three Phase Recloser MV", "code": 748 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps", "description": "Medium Voltage Recloser Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "280 A", "code": 280 }, { "name": "400 A", "code": 400 }, { "name": "560 A", "code": 560 }, { "name": "600 A", "code": 600 }, { "name": "630 A", "code": 630 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 41, "name": "Medium Voltage Recloser" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer", "description": "Medium Voltage Secitionalizer", "codedValues": [ { "name": "Sectionalizer", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Sectionalizer MV", "code": 731 }, { "name": "Overhead Three Phase Sectionalizer MV", "code": 745 }, { "name": "Pad Mounted Single Phase Sectionalizer MV", "code": 749 }, { "name": "Pad Mounted Three Phase Sectionalizer MV", "code": 750 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 42, "name": "Medium Voltage Sectionalizer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch", "description": "Medium Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Cabinet Bypass MV", "code": 721 }, { "name": "Cabinet Switch MV", "code": 722 }, { "name": "Cabinet Switch - Grounded MV", "code": 723 }, { "name": "Overhead Bypass MV", "code": 724 }, { "name": "Overhead Grounding Switch MV", "code": 725 }, { "name": "Overhead Jumper MV", "code": 726 }, { "name": "Station Grounding MV", "code": 727 }, { "name": "Overhead Single Phase Disconnect MV", "code": 728 }, { "name": "Overhead Single Phase Load Break MV", "code": 729 }, { "name": "Overhead Three Phase Disconnect MV", "code": 732 }, { "name": "Overhead Three Phase Load Break MV", "code": 733 }, { "name": "Pad Mounted Fault Interrupter MV", "code": 746 }, { "name": "Station Single Phase Disconnect MV", "code": 751 }, { "name": "Station Disconnect MV", "code": 752 }, { "name": "T Blade MV", "code": 753 }, { "name": "V Blade MV", "code": 754 }, { "name": "Underground Single Phase Disconnect MV", "code": 755 }, { "name": "Underground Single Phase Load Break MV", "code": 758 }, { "name": "Underground Three Phase Disconnect MV", "code": 759 }, { "name": "Underground Three Phase Load Break MV", "code": 760 }, { "name": "Underground Transfer Switch MV", "code": 761 }, { "name": "Bus Tie Breaker MV", "code": 765 }, { "name": "Station Load Break MV", "code": 766 }, { "name": "Station Disconnect - Grounded MV", "code": 768 }, { "name": "Station Load Break Disconnect MV", "code": 769 }, { "name": "Station Disconnect MV - Controller", "code": 770 }, { "name": "Station Load Break MV - Controller", "code": 771 }, { "name": "Station Load Break Disconnect MV - Controller", "code": 772 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps", "description": "Medium Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "900 A", "code": 900 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 37, "name": "Medium Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer", "description": "Medium Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Grounding Transformer - MV->MV", "code": 781 }, { "name": "Mobile Single Phase - MV->LV", "code": 782 }, { "name": "Mobile Three Phase - MV->LV", "code": 783 }, { "name": "Network - MV->LV", "code": 784 }, { "name": "Overhead Single Phase - MV->LV", "code": 785 }, { "name": "Station - MV->LV", "code": 786 }, { "name": "Station Three Winding - MV->LV-LV", "code": 787 }, { "name": "Overhead Three Phase - MV->LV", "code": 788 }, { "name": "Pad Mounted Single Phase - MV->LV", "code": 789 }, { "name": "Station Three Winding - MV->MV-LV", "code": 790 }, { "name": "Pad Mounted Three Phase - MV->LV", "code": 792 }, { "name": "Submersible Single Phase - MV->LV", "code": 793 }, { "name": "Submersible Three Phase - MV->LV", "code": 794 }, { "name": "Overhead Open Delta - MV->LV", "code": 795 }, { "name": "Overhead Open Wye - MV->LV", "code": 796 }, { "name": "Pad Mounted Open Delta - MV->LV", "code": 797 }, { "name": "Pad Mounted Open Wye - MV->LV", "code": 798 }, { "name": "Overhead Single Phase Step - MV<->MV", "code": 801 }, { "name": "Overhead Three Phase Step - MV<->MV", "code": 802 }, { "name": "Overhead Single Phase Step - MV->MV", "code": 803 }, { "name": "Overhead Three Phase Step - MV->MV", "code": 804 }, { "name": "Pad Mounted Single Phase Step - MV<->MV", "code": 805 }, { "name": "Pad Mounted Three Phase Step - MV<->MV", "code": 806 }, { "name": "Pad Mounted Single Phase Step - MV->MV", "code": 807 }, { "name": "Pad Mounted Three Phase Step - MV->MV", "code": 808 }, { "name": "Submersible Single Phase Step - MV<->MV", "code": 809 }, { "name": "Overhead Three Phase Wye Delta Closed Ground", "code": 810 }, { "name": "Submersible Single Phase Step - MV->MV", "code": 811 }, { "name": "Pad Mounted Three Phase Wye Delta Closed Ground", "code": 812 }, { "name": "Station Step - MV->MV", "code": 813 }, { "name": "Station Step - MV<->MV", "code": 814 }, { "name": "Station Step Three Winding - MV->MV-MV", "code": 815 }, { "name": "Overhead Three Phase Step Up - LV->MV", "code": 816 }, { "name": "Overhead Three Phase Step Up - LV<->MV", "code": 817 }, { "name": "Station Step Up - LV->MV", "code": 818 }, { "name": "Station Step Up - LV<->MV", "code": 819 }, { "name": "Pad Mounted Three Phase Step Up - LV->MV", "code": 820 }, { "name": "Pad Mounted Three Phase Step Up - LV<->MV", "code": 821 }, { "name": "Overhead Single Phase Step Up - LV->MV", "code": 822 }, { "name": "Overhead Single Phase Step Up - LV<->MV", "code": 823 }, { "name": "Pad Mounted Single Phase Step Up - LV->MV", "code": 824 }, { "name": "Pad Mounted Single Phase Step Up - LV<->MV", "code": 825 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 38, "name": "Medium Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 62, "name": "Medium Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "Transformer Winding MV", "code": 873 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 47, "name": "Medium Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker", "description": "Asset Types for Low Voltage Circuit Breakers", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Circuit Breaker LV", "code": 471 }, { "name": "DC Circuit Breaker LV", "code": 472 }, { "name": "AC Circuit Breaker LV - Controller", "code": 473 }, { "name": "DC Circuit Breaker LV - Controller", "code": 474 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Low Voltage Circuit Breaker Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 40, "name": "Low Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit", "description": "Low Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Control Unit LV", "code": 241 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 13, "name": "Low Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse", "description": "Low Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "Service Fuse Load Break LV", "code": 259 }, { "name": "Service Fuse Disconnect LV", "code": 260 }, { "name": "AC Overhead Fuse LV", "code": 261 }, { "name": "AC Underground Fuse LV", "code": 262 }, { "name": "DC Overhead Fuse LV", "code": 263 }, { "name": "DC Underground Fuse LV", "code": 264 }, { "name": "AC Overhead Load Break Fuse LV", "code": 265 }, { "name": "AC Overhead Fuse LV - Controller", "code": 266 }, { "name": "AC Underground Load Break Fuse LV", "code": 267 }, { "name": "AC Underground Fuse LV - Controller", "code": 268 }, { "name": "DC Overhead Fuse LV - Controller", "code": 269 }, { "name": "DC Underground Fuse LV - Controller", "code": 270 }, { "name": "AC Overhead Cutout Load Break Disconnect Fuse LV", "code": 271 }, { "name": "AC Overhead Cutout Load Break Fuse LV - Controller", "code": 272 }, { "name": "AC Overhead Cutout Disconnect Fuse LV - Controller", "code": 273 }, { "name": "AC Overhead Cutout Load Break Fuse LV", "code": 274 }, { "name": "Station Disconnect Fuse LV", "code": 275 }, { "name": "Station Load Break Fuse LV", "code": 276 }, { "name": "Station Load Break Disconnect Fuse LV", "code": 277 }, { "name": "Station Disconnect Fuse LV - Controller", "code": 278 }, { "name": "Station Load Break Fuse LV - Controller", "code": 279 }, { "name": "Station Load Break Disconnect Fuse LV - Controller", "code": 280 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Type", "description": "List of valid fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Link_Type", "description": "Types of fuse links", "codedValues": [ { "name": "K", "code": 10 }, { "name": "T", "code": 11 }, { "name": "MS", "code": 12 }, { "name": "QH", "code": 13 }, { "name": "Standard", "code": 14 }, { "name": "SloFast", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 14, "name": "Low Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation", "description": "Low Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery LV", "code": 281 }, { "name": "Generator LV", "code": 283 }, { "name": "Residential Photovoltaic Solar LV", "code": 284 }, { "name": "Wind Turbine LV", "code": 285 }, { "name": "AC Wave LV", "code": 286 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 15, "name": "Low Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting", "description": "Low Voltage Lighting", "codedValues": [ { "name": "Lighting", "code": 0 }, { "name": "Floodlight LV", "code": 301 }, { "name": "Streetlight LV", "code": 302 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Light_Housing_Type", "description": "Light Housing Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cobra Head", "code": 1 }, { "name": "Security", "code": 2 }, { "name": "Roadway", "code": 3 }, { "name": "Flood", "code": 4 }, { "name": "Decorative", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Street_Bulb_Type", "description": "List of valid bulb types for streetlights", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High Pressure Sodium (HPS)", "code": 30 }, { "name": "Low Pressure Sodium (LPS)", "code": 31 }, { "name": "Metal Halide (MH)", "code": 32 }, { "name": "Mercury Vapor (MV)", "code": 33 }, { "name": "Halogen (HG)", "code": 34 }, { "name": "Light Emitting Diode (LED)", "code": 35 }, { "name": "Phosphor-Converted Amber LED (PCA)", "code": 36 }, { "name": "Narrow-Band Amber LED (NBA)", "code": 37 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "lightsphotoeye": {"type": "inherited"}, "lightswattage": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 16, "name": "Low Voltage Lighting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay", "description": "Low Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator LV", "code": 321 }, { "name": "Load Monitor LV", "code": 322 }, { "name": "Relay LV", "code": 323 }, { "name": "Instrument Transformer LV", "code": 324 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 17, "name": "Low Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor", "description": "Low Voltage Motor", "codedValues": [ { "name": "Motor", "code": 0 }, { "name": "Single Phase Motor LV", "code": 341 }, { "name": "Three Phase Motor LV", "code": 342 }, { "name": "DC Motor LV", "code": 343 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 18, "name": "Low Voltage Motor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection", "description": "Low Voltage Network Protection", "codedValues": [ { "name": "Network Protector", "code": 0 }, { "name": "Network Protector LV", "code": 361 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 19, "name": "Low Voltage Network Protection" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion", "description": "Low Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter LV", "code": 381 }, { "name": "Single Phase Rectifier LV", "code": 382 }, { "name": "Three Phase Inverter LV", "code": 383 }, { "name": "Three Phase Rectifier LV", "code": 384 }, { "name": "Single Phase Bidirectional LV", "code": 386 }, { "name": "Three Phase Bidirectional LV", "code": 387 }, { "name": "Wave Trap LV", "code": 390 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 20, "name": "Low Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting", "description": "Low Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "Mobile Harmonic Filter LV", "code": 401 }, { "name": "Mobile Reactor LV", "code": 402 }, { "name": "Overhead Capacitor LV", "code": 403 }, { "name": "Overhead Harmonic Filter LV", "code": 404 }, { "name": "Overhead Reactor LV", "code": 405 }, { "name": "Pad Mounted Capacitor LV", "code": 406 }, { "name": "Pad Mounted Harmonic Filter LV", "code": 407 }, { "name": "Pad Mounted Reactor LV", "code": 408 }, { "name": "Station Capacitor LV", "code": 409 }, { "name": "Station Harmonic Filter LV", "code": 410 }, { "name": "Station Reactor LV", "code": 411 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 21, "name": "Low Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service", "description": "Low Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Single Phase Commercial LV", "code": 421 }, { "name": "Single Phase Residential LV", "code": 422 }, { "name": "Three Phase Commercial LV", "code": 423 }, { "name": "Three Phase Residential LV", "code": 424 }, { "name": "Unmetered Load LV", "code": 425 }, { "name": "DC Commercial LV", "code": 426 }, { "name": "Low Voltage Premise LV", "code": 427 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 22, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch", "description": "Low Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Station Disconnect LV", "code": 431 }, { "name": "AC Station Load Break LV", "code": 432 }, { "name": "AC Station Load Break Disconnect LV", "code": 433 }, { "name": "AC Station Disconnect LV - Controller", "code": 434 }, { "name": "AC Station Load Break LV - Controller", "code": 435 }, { "name": "AC Station Load Break Disconnect LV - Controller", "code": 436 }, { "name": "Overhead AC Load Break LV", "code": 441 }, { "name": "Overhead AC Disconnect LV", "code": 442 }, { "name": "Overhead DC Load Break LV", "code": 443 }, { "name": "Overhead DC Disconnect LV", "code": 444 }, { "name": "Underground AC Load Break LV", "code": 445 }, { "name": "Underground AC Disconnect LV", "code": 446 }, { "name": "Underground DC Load Break LV", "code": 447 }, { "name": "Underground DC Disconnect LV", "code": 448 }, { "name": "Indoor AC Load Break LV", "code": 449 }, { "name": "Indoor AC Disconnect LV", "code": 450 }, { "name": "Indoor DC Load Break LV", "code": 451 }, { "name": "Indoor DC Disconnect LV", "code": 452 }, { "name": "Source Selectable Switch LV", "code": 453 }, { "name": "Overhead Jumper LV", "code": 454 }, { "name": "DC Station LV", "code": 456 }, { "name": "AC Station Bypass LV", "code": 457 }, { "name": "AC Recloser LV", "code": 458 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps", "description": "Low Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "45 A", "code": 45 }, { "name": "50 A", "code": 50 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "300 A", "code": 300 }, { "name": "320 A", "code": 320 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 }, { "name": "2500 A", "code": 2500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 23, "name": "Low Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer", "description": "Low Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Single Phase - LV->LV", "code": 461 }, { "name": "Three Phase - LV->LV", "code": 462 }, { "name": "Three Winding - LV->LV-LV", "code": 463 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 24, "name": "Low Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector", "description": "Low Voltage Connectors", "codedValues": [ { "name": "Wire Connector", "code": 0 }, { "name": "Ring Terminal LV", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 44, "name": "Low Voltage Wire Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator", "description": "Asset Types for Low Voltage Regulating Equipment", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase LV", "code": 141 }, { "name": "AC Three Phase LV", "code": 142 }, { "name": "DC Regulator LV", "code": 143 }, { "name": "Network Load Balancer LV", "code": 144 }, { "name": "Frequency Converter LV", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 45, "name": "Low Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding LV", "code": 874 }, { "name": "DC Transformer Winding LV", "code": 875 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 46, "name": "Low Voltage Transformer Winding" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tertiarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": null, "maintby": null, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Ground", "description": "Ground", "codedValues": [ { "name": "Ground", "code": 0 }, { "name": "Bound", "code": 31 }, { "name": "Rod", "code": 32 }, { "name": "Voltage Grid", "code": 33 }, { "name": "Stray Voltage Isolator", "code": 34 }, { "name": "Grounding Switch", "code": 35 }, { "name": "Cross Bond", "code": 36 }, { "name": "Ground Plate", "code": 37 }, { "name": "Ground Joint", "code": 38 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Ground_Type", "description": "Ground Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bound", "code": 1 }, { "name": "Mesh", "code": 2 }, { "name": "Rod", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 1, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Control_Unit", "description": "High Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor HV", "code": 41 }, { "name": "Switch and Breaker HV", "code": 42 }, { "name": "Voltage Regulator HV", "code": 43 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 3, "name": "High Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Generation", "description": "High Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery HV", "code": 61 }, { "name": "Biomass HV", "code": 62 }, { "name": "Coal HV", "code": 63 }, { "name": "Gas Turbine HV", "code": 64 }, { "name": "Geothermal HV", "code": 65 }, { "name": "Hydro HV", "code": 66 }, { "name": "Nuclear HV", "code": 67 }, { "name": "Photovoltaic Solar HV", "code": 68 }, { "name": "Thermal Solar HV", "code": 69 }, { "name": "Wind HV", "code": 70 }, { "name": "AC Wave HV", "code": 71 }, { "name": "Generator HV", "code": 72 }, { "name": "Interconnect HV", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 4, "name": "High Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Fuse", "description": "High Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Station Disconnect Fuse HV", "code": 581 }, { "name": "AC Station Load Break Fuse HV", "code": 582 }, { "name": "AC Load Break Disconnect Fuse HV", "code": 583 }, { "name": "AC Load Break Fuse HV - Controller", "code": 584 }, { "name": "AC Disconnect Fuse HV - Controller", "code": 585 }, { "name": "AC Load Break Disconnect Fuse HV - Controller", "code": 586 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Continuous_Current", "description": "List of valid High Voltage Switching and Protective Maximum Continuous Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "1200 A", "code": 1200 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "3000 A", "code": 3000 }, { "name": "6000 A", "code": 6000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Interrupting_Current", "description": "List of valid High Voltage Switching and Protective Maximum Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "60 kA", "code": 60000 }, { "name": "80 kA", "code": 80000 }, { "name": "90 kA", "code": 90000 }, { "name": "2 kA", "code": 2000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 43, "name": "High Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay", "description": "High Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator HV", "code": 80 }, { "name": "Instrument Transformer HV", "code": 81 }, { "name": "Load Monitor HV", "code": 82 }, { "name": "Relay HV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Phase_Angle_Offset_Range", "description": "Phase Offset values 0 - 60", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 5, "name": "High Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Conversion", "description": "High Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Inverter HV", "code": 101 }, { "name": "Rectifier HV", "code": 102 }, { "name": "Bidirectional HV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_DC_Voltage", "description": "Valid High Voltage Direct Current Voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "270 kV", "code": 270000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "500 kV", "code": 500000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1000 kV", "code": 1000000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 }, { "name": "1400 kV", "code": 1400000 }, { "name": "1500 kV", "code": 1500000 }, { "name": "1800 kV", "code": 1800000 }, { "name": "2500 kV", "code": 2500000 }, { "name": "3000 kV", "code": 3000000 }, { "name": "4000 kV", "code": 4000000 }, { "name": "5000 kV", "code": 5000000 }, { "name": "6000 kV", "code": 6000000 }, { "name": "6400 kV", "code": 6400000 }, { "name": "7200 kV", "code": 7200000 }, { "name": "8000 kV", "code": 8000000 }, { "name": "10000 kV", "code": 10000000 }, { "name": "12000 kV", "code": 12000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Generate_Watts", "description": "Maximum Generation Station Watts output", "codedValues": [ { "name": "Idle", "code": -1 }, { "name": "Unknown", "code": 0 }, { "name": "540 MW", "code": 540 }, { "name": "1540 MW", "code": 1540 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 6, "name": "High Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting", "description": "High Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Capacitor HV", "code": 121 }, { "name": "AC Wave Trap HV", "code": 122 }, { "name": "AC Reactor HV", "code": 123 }, { "name": "DC Capacitor HV", "code": 124 }, { "name": "DC Reactor HV", "code": 125 }, { "name": "Synchronous Condenser HV", "code": 126 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "designtype": { "type": "codedValue", "name": "WS1_Electric_Power_Factor_Correcting_Type", "description": "Type of Power Factor Correcting Equipment", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_High_Voltage_Maximum_Current", "description": "Maximum Current Range Domain", "range": [ 0, 15000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_KVAR", "description": "Domain for valid kVAR rating for High Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "600 kvar", "code": 600000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 7, "name": "High Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Regulator", "description": "High Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase HV", "code": 171 }, { "name": "AC Three Phase HV", "code": 172 }, { "name": "DC Regulator HV", "code": 173 }, { "name": "Frequency Converter HV", "code": 174 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Regulator_VA", "description": "List of valid High Voltage Regulator in volt amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".5 MVA", "code": 500000 }, { "name": "1 MVA", "code": 1000000 }, { "name": "1.5 MVA", "code": 1500000 }, { "name": "2 MVA", "code": 2000000 }, { "name": "2.5 MVA", "code": 2500000 }, { "name": "3 MVA", "code": 3000000 }, { "name": "3.5 MVA", "code": 3500000 }, { "name": "4 MVA", "code": 4000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 8, "name": "High Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Service", "description": "High Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "AC Metering HV", "code": 161 }, { "name": "DC Metering HV", "code": 162 }, { "name": "High Voltage Premise HV", "code": 163 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Service_Load_kW", "description": "Range domain of valid kW loads", "range": [ 0, 500000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 9, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Switch", "description": "High Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Circuit Breaker HV", "code": 181 }, { "name": "AC Disconnect HV", "code": 182 }, { "name": "AC Switchgear HV", "code": 183 }, { "name": "DC Circuit Breaker HV", "code": 184 }, { "name": "DC Disconnect HV", "code": 185 }, { "name": "DC Switchgear HV", "code": 186 }, { "name": "AC Bus Tie Breaker HV", "code": 187 }, { "name": "DC Bus Tie Breaker HV", "code": 188 }, { "name": "AC Disconnect - Grounded HV", "code": 189 }, { "name": "AC Breaker Bypass HV", "code": 190 }, { "name": "AC Circuit Breaker HV - Controller", "code": 191 }, { "name": "AC Station Disconnect HV", "code": 192 }, { "name": "AC Station Load Break Disconnect HV - Controller", "code": 193 }, { "name": "DC Circuit Breaker HV - Controller", "code": 194 }, { "name": "AC Disconnect HV - Controller", "code": 195 }, { "name": "AC Grounding HV", "code": 196 }, { "name": "AC Thyristor HV", "code": 197 }, { "name": "DC Thyristor HV", "code": 198 }, { "name": "AC Transfer Switch HV", "code": 199 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Interrupting_Amps", "description": "High Voltage Switch Interrupting Current", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.6 kA", "code": 1600 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Switch_Continuous_Amps", "description": "High Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": ".6 kA", "code": 600 }, { "name": "1.2 kA", "code": 1200 }, { "name": "1.25 kA", "code": 1250 }, { "name": "1.6 kA", "code": 1600 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 10, "name": "High Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer", "description": "High Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "AC Single Phase - HV->MV", "code": 201 }, { "name": "AC Three Phase - HV->MV", "code": 202 }, { "name": "DC Power - HV->HV", "code": 203 }, { "name": "Grounding Transformer - HV->MV", "code": 204 }, { "name": "Station - HV->MV", "code": 205 }, { "name": "Station Three Winding - HV->HV-HV", "code": 206 }, { "name": "Station Three Winding - HV->HV-MV", "code": 207 }, { "name": "Phase Control - HV->HV", "code": 208 }, { "name": "Station Three Winding - HV->HV-LV", "code": 209 }, { "name": "Station Step Up - MV->HV", "code": 210 }, { "name": "Station Step - HV->HV", "code": 211 }, { "name": "Station Three Winding - HV->MV-MV", "code": 212 }, { "name": "Station Three Winding - HV->MV-LV", "code": 213 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Number_of_Phases", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Watts", "description": "Maximum Load in Watts", "range": [ 0, 20000000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "tapmaxchange": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Transformer_VA", "description": "List of valid High Voltage Transformer Power Rating", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5.5 MVA", "code": 5500000 }, { "name": "74 MVA", "code": 74000000 }, { "name": "75 MVA", "code": 75000000 }, { "name": "200 MVA", "code": 200000000 }, { "name": "300 MVA", "code": 300000000 }, { "name": "350 MVA", "code": 350000000 }, { "name": "400 MVA", "code": 400000000 }, { "name": "500 MVA", "code": 500000000 }, { "name": "550 MVA", "code": 550000000 }, { "name": "650 MVA", "code": 650000000 }, { "name": "750 MVA", "code": 750000000 }, { "name": "1000 MVA", "code": 1000000000 }, { "name": "1200 MVA", "code": 1200000000 }, { "name": "1500 MVA", "code": 1500000000 }, { "name": "100 MVA", "code": 10000000 }, { "name": "200 MVA", "code": 20000000 }, { "name": "300 MVA", "code": 30000000 }, { "name": "350 MVA", "code": 35000000 }, { "name": "400 MVA", "code": 40000000 }, { "name": "500 MVA", "code": 50000000 }, { "name": "550 MVA", "code": 55000000 }, { "name": "650 MVA", "code": 65000000 }, { "name": "1000 MVA", "code": 100000000 }, { "name": "1200 MVA", "code": 120000000 }, { "name": "1500 MVA", "code": 150000000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_High_Voltage_Load_Loss", "description": "Valid Load Loss Range for High Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 11, "name": "High Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Line Hardware", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 61, "name": "High Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_High_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding HV", "code": 871 }, { "name": "DC Transformer Winding HV", "code": 872 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 48, "name": "High Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker", "description": "Medium Voltage Circuit Breaker", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "Isolator Switch MV", "code": 501 }, { "name": "Single Phase Circuit Breaker MV", "code": 502 }, { "name": "Three Phase Circuit Breaker MV", "code": 503 }, { "name": "Single Phase Circuit Breaker MV - Controller", "code": 512 }, { "name": "Three Phase Circuit Breaker MV - Controller", "code": 513 }, { "name": "Network Protector MV", "code": 515 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees", "description": "Positive and Negative degrees in whole units", "range": [ -180, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Medium Voltage Circuit Breaker Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Medium Voltage Circuit Breaker Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "1250 A", "code": 1250 }, { "name": "1600 A", "code": 1600 }, { "name": "2000 A", "code": 2000 }, { "name": "2500 A", "code": 2500 }, { "name": "3000 A", "code": 3000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 26, "name": "Medium Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Control_Unit", "description": "Medium Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Capacitor MV", "code": 521 }, { "name": "Circuit Breaker MV", "code": 522 }, { "name": "Recloser MV", "code": 523 }, { "name": "Transfer Switch Controller MV", "code": 524 }, { "name": "Regulator MV", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 27, "name": "Medium Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Elbow", "description": "Medium Voltage Elbow", "codedValues": [ { "name": "Elbow", "code": 0 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Load Break Feedthru MV", "code": 541 }, { "name": "Load Break Junction MV", "code": 542 }, { "name": "Single Phase Dead Break MV", "code": 543 }, { "name": "Single Phase Load Break MV", "code": 544 }, { "name": "Three Phase Dead Break MV", "code": 545 }, { "name": "Three Phase Load Break MV", "code": 546 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 28, "name": "Medium Voltage Elbow" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Fuse", "description": "Medium Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Bayonet Fuse MV", "code": 561 }, { "name": "Fault Limiter Fuse MV", "code": 562 }, { "name": "Indoor Fuse MV", "code": 563 }, { "name": "Overhead Cutout Disconnect Fuse MV", "code": 564 }, { "name": "Overhead Cutout Load Break Fuse MV", "code": 565 }, { "name": "Overhead Cutout Sectionalizer Fuse MV", "code": 566 }, { "name": "Overhead Cutout Solid Blade Fuse MV", "code": 567 }, { "name": "Cabinet Fuse MV", "code": 568 }, { "name": "Underground Fuse MV", "code": 569 }, { "name": "Underground Disconnect Fuse MV", "code": 570 }, { "name": "Underground Load Break Fuse MV", "code": 571 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV", "code": 572 }, { "name": "Overhead Cutout Load Break Fuse MV - Controller", "code": 573 }, { "name": "Overhead Cutout Disconnect Fuse MV - Controller", "code": 574 }, { "name": "Overhead Cutout Load Break Disconnect Fuse MV - Controller", "code": 575 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Rating", "description": "List of valid Electric Medium Voltage Fuse Ratingsl", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "C", "code": 1 }, { "name": "E", "code": 2 }, { "name": "R", "code": 3 }, { "name": "PT", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Type", "description": "Medium Voltage fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridged", "code": 1 }, { "name": "Burndy", "code": 2 }, { "name": "Bussman", "code": 3 }, { "name": "Cooper Elf", "code": 4 }, { "name": "D & W", "code": 5 }, { "name": "EJO-1", "code": 6 }, { "name": "Fault Tamer", "code": 7 }, { "name": "Kearney", "code": 8 }, { "name": "Kearney 200", "code": 9 }, { "name": "Kearney QA", "code": 10 }, { "name": "RTE B", "code": 11 }, { "name": "S & C", "code": 12 }, { "name": "S & C SM-4", "code": 13 }, { "name": "X-Limiter", "code": 14 }, { "name": "NX", "code": 15 }, { "name": "CL", "code": 16 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "250 A", "code": 250 }, { "name": "500 A", "code": 500 }, { "name": "600 A", "code": 600 }, { "name": "1080 A", "code": 1080 }, { "name": "8000 A", "code": 8000 }, { "name": "10000 A", "code": 10000 }, { "name": "12000 A", "code": 12000 }, { "name": "16000 A", "code": 16000 }, { "name": "20000 A", "code": 20000 }, { "name": "40000 A", "code": 40000 }, { "name": "60000 A", "code": 60000 }, { "name": "80000 A", "code": 80000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "65 A", "code": 65 }, { "name": "80 A", "code": 80 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "150 A", "code": 150 }, { "name": "175 A", "code": 175 }, { "name": "180 A", "code": 180 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "250 A", "code": 250 }, { "name": "300 A", "code": 300 }, { "name": "350 A", "code": 350 }, { "name": "400 A", "code": 400 }, { "name": "450 A", "code": 450 }, { "name": "500 A", "code": 500 }, { "name": "550 A", "code": 550 }, { "name": "600 A", "code": 600 }, { "name": "140 A", "code": 140 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 29, "name": "Medium Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Generation", "description": "Medium Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "AC Wave MV", "code": 110 }, { "name": "Battery MV", "code": 111 }, { "name": "Biomass MV", "code": 112 }, { "name": "Generator MV", "code": 113 }, { "name": "Gas Turbine MV", "code": 114 }, { "name": "Geothermal MV", "code": 115 }, { "name": "Hydro MV", "code": 116 }, { "name": "Wind MV", "code": 117 }, { "name": "Photovoltaic Solar MV", "code": 118 }, { "name": "Thermal Solar MV", "code": 119 }, { "name": "Interconnect MV", "code": 120 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 30, "name": "Medium Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay", "description": "Medium Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator MV", "code": 601 }, { "name": "Instrument Transformer MV", "code": 602 }, { "name": "Programmable Logic Unit MV", "code": 603 }, { "name": "Remote Terminal Unit MV", "code": 604 }, { "name": "SCADA Load Monitor MV", "code": 605 }, { "name": "SCADA Weather Station MV", "code": 606 }, { "name": "Relay MV", "code": 607 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 31, "name": "Medium Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump", "description": "Medium Voltage Motor and Pump", "codedValues": [ { "name": "Motor and Pump", "code": 0 }, { "name": "Single Phase Motor MV", "code": 621 }, { "name": "Single Phase Pump MV", "code": 622 }, { "name": "Three Phase Motor MV", "code": 623 }, { "name": "Three Phase Pump MV", "code": 624 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 32, "name": "Medium Voltage Motor and Pump" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion", "description": "Medium Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter MV", "code": 641 }, { "name": "Single Phase Rectifier MV", "code": 642 }, { "name": "Three Phase Inverter MV", "code": 643 }, { "name": "Three Phase Rectifier MV", "code": 644 }, { "name": "Single Phase Bidirectional MV", "code": 645 }, { "name": "Three Phase Bidirectional MV", "code": 646 }, { "name": "Wave Trap MV", "code": 647 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 33, "name": "Medium Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting", "description": "Medium Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Mobile Capacitor MV", "code": 661 }, { "name": "Overhead Single Phase Capacitor MV", "code": 664 }, { "name": "Overhead Three Phase Capacitor MV", "code": 665 }, { "name": "Overhead Harmonic Filter MV", "code": 666 }, { "name": "Overhead Reactor MV", "code": 667 }, { "name": "Pad Mounted Single Phase Capacitor MV", "code": 668 }, { "name": "Pad Mounted Three Phase Capacitor MV", "code": 669 }, { "name": "Mobile Harmonic Filter MV", "code": 671 }, { "name": "Mobile Reactor MV", "code": 672 }, { "name": "Pad Mounted Harmonic Filter MV", "code": 673 }, { "name": "Pad Mounted Reactor MV", "code": 674 }, { "name": "Station Capacitor MV", "code": 675 }, { "name": "Station Harmonic Filter MV", "code": 676 }, { "name": "Station Reactor MV", "code": 677 }, { "name": "Synchronous Condenser MV", "code": 678 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_KVAR", "description": "Domain of valid kVAR ratings for Medium Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "5 kvar", "code": 5000 }, { "name": "10 kvar", "code": 10000 }, { "name": "20 kvar", "code": 20000 }, { "name": "30 kvar", "code": 30000 }, { "name": "50 kvar", "code": 50000 }, { "name": "100 kvar", "code": 100000 }, { "name": "150 kvar", "code": 150000 }, { "name": "200 kvar", "code": 200000 }, { "name": "300 kvar", "code": 300000 }, { "name": "400 kvar", "code": 400000 }, { "name": "500 kvar", "code": 500000 }, { "name": "600 kvar", "code": 600000 }, { "name": "800 kvar", "code": 800000 }, { "name": "1200 kvar", "code": 1200000 }, { "name": "1500 kvar", "code": 1500000 }, { "name": "1800 kvar", "code": 1800000 }, { "name": "2400 kvar", "code": 2400000 }, { "name": "3600 kvar", "code": 3600000 }, { "name": "900 kvar", "code": 900000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 34, "name": "Medium Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Regulator", "description": "Medium Voltage Regulator", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Overhead Single Phase VR MV", "code": 681 }, { "name": "Overhead Three Phase VR MV", "code": 683 }, { "name": "Pad Mounted Single Phase VR MV", "code": 685 }, { "name": "Pad Mounted Three Phase VR MV", "code": 687 }, { "name": "Frequency Converter MV", "code": 688 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Regulator_VA", "description": "Medium Voltage Regulator VA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kVA", "code": 25000 }, { "name": "38 kVA", "code": 38000 }, { "name": "38.1 kVA", "code": 38100 }, { "name": "50 kVA", "code": 50000 }, { "name": "57 kVA", "code": 57000 }, { "name": "57.2 kVA", "code": 57200 }, { "name": "69 kVA", "code": 69000 }, { "name": "72 kVA", "code": 72000 }, { "name": "75 kVA", "code": 75000 }, { "name": "76 kVA", "code": 76000 }, { "name": "76.2 kVA", "code": 76200 }, { "name": "100 kVA", "code": 100000 }, { "name": "114 kVA", "code": 114000 }, { "name": "114.3 kVA", "code": 114300 }, { "name": "124.8 kVA", "code": 124800 }, { "name": "138 kVA", "code": 138000 }, { "name": "144 kVA", "code": 144000 }, { "name": "150 kVA", "code": 150000 }, { "name": "152 kVA", "code": 152000 }, { "name": "167 kVA", "code": 167000 }, { "name": "171.6 kVA", "code": 171600 }, { "name": "172.5 kVA", "code": 172500 }, { "name": "200 kVA", "code": 200000 }, { "name": "207 kVA", "code": 207000 }, { "name": "216 kVA", "code": 216000 }, { "name": "219 kVA", "code": 219000 }, { "name": "228.6 kVA", "code": 228600 }, { "name": "250 kVA", "code": 250000 }, { "name": "276 kVA", "code": 276000 }, { "name": "288 kVA", "code": 288000 }, { "name": "300 kVA", "code": 300000 }, { "name": "332 kVA", "code": 332000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342.9 kVA", "code": 342900 }, { "name": "345 kVA", "code": 345000 }, { "name": "400 kVA", "code": 400000 }, { "name": "414 kVA", "code": 414000 }, { "name": "416 kVA", "code": 416000 }, { "name": "432 kVA", "code": 432000 }, { "name": "456 kVA", "code": 456000 }, { "name": "500 kVA", "code": 500000 }, { "name": "517.5 kVA", "code": 517500 }, { "name": "518 kVA", "code": 518000 }, { "name": "552 kVA", "code": 552000 }, { "name": "576 kVA", "code": 576000 }, { "name": "600 kVA", "code": 600000 }, { "name": "621 kVA", "code": 621000 }, { "name": "657 kVA", "code": 657000 }, { "name": "667 kVA", "code": 667000 }, { "name": "690 kVA", "code": 690000 }, { "name": "700 kVA", "code": 700000 }, { "name": "720 kVA", "code": 720000 }, { "name": "750 kVA", "code": 750000 }, { "name": "828 kVA", "code": 828000 }, { "name": "833 kVA", "code": 833000 }, { "name": "863 kVA", "code": 863000 }, { "name": "864 kVA", "code": 864000 }, { "name": "996 kVA", "code": 996000 }, { "name": "999 kVA", "code": 999000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1035 kVA", "code": 1035000 }, { "name": "1145 kVA", "code": 1145000 }, { "name": "1200 kVA", "code": 1200000 }, { "name": "1242 kVA", "code": 1242000 }, { "name": "1248 kVA", "code": 1248000 }, { "name": "1296 kVA", "code": 1296000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1554 kVA", "code": 1554000 }, { "name": "1656 kVA", "code": 1656000 }, { "name": "1728 kVA", "code": 1728000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2001 kVA", "code": 2001000 }, { "name": "2070 kVA", "code": 2070000 }, { "name": "2100 kVA", "code": 2100000 }, { "name": "2160 kVA", "code": 2160000 }, { "name": "2499 kVA", "code": 2499000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "2589 kVA", "code": 2589000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3462 kVA", "code": 3462000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 35, "name": "Medium Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Service", "description": "Medium Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Primary Meter - Industrial Customer MV", "code": 701 }, { "name": "Primary Meter - Utility Customer MV", "code": 702 }, { "name": "Primary Meter Circuit Source MV", "code": 703 }, { "name": "Medium Voltage Premise MV", "code": 704 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 36, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Recloser", "description": "Medium Voltage Recloser Asset Types", "codedValues": [ { "name": "Recloser", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Recloser MV", "code": 730 }, { "name": "Overhead Three Phase Recloser MV - Controller", "code": 734 }, { "name": "Pad Mounted Three Phase Recloser MV - Controller", "code": 738 }, { "name": "Overhead Three Phase Recloser MV", "code": 744 }, { "name": "Pad Mounted Single Phase Recloser MV", "code": 747 }, { "name": "Pad Mounted Three Phase Recloser MV", "code": 748 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Interrupting_Amps", "description": "Medium Voltage Recloser Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 kA", "code": 2000 }, { "name": "2.5 kA", "code": 2500 }, { "name": "3 kA", "code": 3000 }, { "name": "4 kA", "code": 4000 }, { "name": "6 kA", "code": 6000 }, { "name": "8 kA", "code": 8000 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Recloser_Continuous_Amps", "description": "Medium Voltage Recloser Continuous Amps Ratings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "280 A", "code": 280 }, { "name": "400 A", "code": 400 }, { "name": "560 A", "code": 560 }, { "name": "600 A", "code": 600 }, { "name": "630 A", "code": 630 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 41, "name": "Medium Voltage Recloser" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer", "description": "Medium Voltage Secitionalizer", "codedValues": [ { "name": "Sectionalizer", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "Overhead Single Phase Sectionalizer MV", "code": 731 }, { "name": "Overhead Three Phase Sectionalizer MV", "code": 745 }, { "name": "Pad Mounted Single Phase Sectionalizer MV", "code": 749 }, { "name": "Pad Mounted Three Phase Sectionalizer MV", "code": 750 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 42, "name": "Medium Voltage Sectionalizer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Switch", "description": "Medium Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "Cabinet Bypass MV", "code": 721 }, { "name": "Cabinet Switch MV", "code": 722 }, { "name": "Cabinet Switch - Grounded MV", "code": 723 }, { "name": "Overhead Bypass MV", "code": 724 }, { "name": "Overhead Grounding Switch MV", "code": 725 }, { "name": "Overhead Jumper MV", "code": 726 }, { "name": "Station Grounding MV", "code": 727 }, { "name": "Overhead Single Phase Disconnect MV", "code": 728 }, { "name": "Overhead Single Phase Load Break MV", "code": 729 }, { "name": "Overhead Three Phase Disconnect MV", "code": 732 }, { "name": "Overhead Three Phase Load Break MV", "code": 733 }, { "name": "Pad Mounted Fault Interrupter MV", "code": 746 }, { "name": "Station Single Phase Disconnect MV", "code": 751 }, { "name": "Station Disconnect MV", "code": 752 }, { "name": "T Blade MV", "code": 753 }, { "name": "V Blade MV", "code": 754 }, { "name": "Underground Single Phase Disconnect MV", "code": 755 }, { "name": "Underground Single Phase Load Break MV", "code": 758 }, { "name": "Underground Three Phase Disconnect MV", "code": 759 }, { "name": "Underground Three Phase Load Break MV", "code": 760 }, { "name": "Underground Transfer Switch MV", "code": 761 }, { "name": "Bus Tie Breaker MV", "code": 765 }, { "name": "Station Load Break MV", "code": 766 }, { "name": "Station Disconnect - Grounded MV", "code": 768 }, { "name": "Station Load Break Disconnect MV", "code": 769 }, { "name": "Station Disconnect MV - Controller", "code": 770 }, { "name": "Station Load Break MV - Controller", "code": 771 }, { "name": "Station Load Break Disconnect MV - Controller", "code": 772 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Interrupting_Amps", "description": "Medium Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "16 kA", "code": 16000 }, { "name": "25 kA", "code": 25000 }, { "name": "29 kA", "code": 29000 }, { "name": "31.5 kA", "code": 31500 }, { "name": "40 kA", "code": 40000 }, { "name": "50 kA", "code": 50000 }, { "name": "63 kA", "code": 63000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Switch_Continuous_Amps", "description": "Medium Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 A", "code": 600 }, { "name": "900 A", "code": 900 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12000, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 37, "name": "Medium Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer", "description": "Medium Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Grounding Transformer - MV->MV", "code": 781 }, { "name": "Mobile Single Phase - MV->LV", "code": 782 }, { "name": "Mobile Three Phase - MV->LV", "code": 783 }, { "name": "Network - MV->LV", "code": 784 }, { "name": "Overhead Single Phase - MV->LV", "code": 785 }, { "name": "Station - MV->LV", "code": 786 }, { "name": "Station Three Winding - MV->LV-LV", "code": 787 }, { "name": "Overhead Three Phase - MV->LV", "code": 788 }, { "name": "Pad Mounted Single Phase - MV->LV", "code": 789 }, { "name": "Station Three Winding - MV->MV-LV", "code": 790 }, { "name": "Pad Mounted Three Phase - MV->LV", "code": 792 }, { "name": "Submersible Single Phase - MV->LV", "code": 793 }, { "name": "Submersible Three Phase - MV->LV", "code": 794 }, { "name": "Overhead Open Delta - MV->LV", "code": 795 }, { "name": "Overhead Open Wye - MV->LV", "code": 796 }, { "name": "Pad Mounted Open Delta - MV->LV", "code": 797 }, { "name": "Pad Mounted Open Wye - MV->LV", "code": 798 }, { "name": "Overhead Single Phase Step - MV<->MV", "code": 801 }, { "name": "Overhead Three Phase Step - MV<->MV", "code": 802 }, { "name": "Overhead Single Phase Step - MV->MV", "code": 803 }, { "name": "Overhead Three Phase Step - MV->MV", "code": 804 }, { "name": "Pad Mounted Single Phase Step - MV<->MV", "code": 805 }, { "name": "Pad Mounted Three Phase Step - MV<->MV", "code": 806 }, { "name": "Pad Mounted Single Phase Step - MV->MV", "code": 807 }, { "name": "Pad Mounted Three Phase Step - MV->MV", "code": 808 }, { "name": "Submersible Single Phase Step - MV<->MV", "code": 809 }, { "name": "Overhead Three Phase Wye Delta Closed Ground", "code": 810 }, { "name": "Submersible Single Phase Step - MV->MV", "code": 811 }, { "name": "Pad Mounted Three Phase Wye Delta Closed Ground", "code": 812 }, { "name": "Station Step - MV->MV", "code": 813 }, { "name": "Station Step - MV<->MV", "code": 814 }, { "name": "Station Step Three Winding - MV->MV-MV", "code": 815 }, { "name": "Overhead Three Phase Step Up - LV->MV", "code": 816 }, { "name": "Overhead Three Phase Step Up - LV<->MV", "code": 817 }, { "name": "Station Step Up - LV->MV", "code": 818 }, { "name": "Station Step Up - LV<->MV", "code": 819 }, { "name": "Pad Mounted Three Phase Step Up - LV->MV", "code": 820 }, { "name": "Pad Mounted Three Phase Step Up - LV<->MV", "code": 821 }, { "name": "Overhead Single Phase Step Up - LV->MV", "code": 822 }, { "name": "Overhead Single Phase Step Up - LV<->MV", "code": 823 }, { "name": "Pad Mounted Single Phase Step Up - LV->MV", "code": 824 }, { "name": "Pad Mounted Single Phase Step Up - LV<->MV", "code": 825 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Transformer_VA", "description": "List of volt amps for devices, displayed in kilovolt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "1.0 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7 kVA", "code": 7000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "20 kVA", "code": 20000 }, { "name": "25 kVA", "code": 25000 }, { "name": "30 kVA", "code": 30000 }, { "name": "37.5 kVA", "code": 37500 }, { "name": "45 kVA", "code": 45000 }, { "name": "50 kVA", "code": 50000 }, { "name": "75 kVA", "code": 75000 }, { "name": "100 kVA", "code": 100000 }, { "name": "112.5 kVA", "code": 112500 }, { "name": "150 kVA", "code": 150000 }, { "name": "167 kVA", "code": 167000 }, { "name": "200 kVA", "code": 200000 }, { "name": "225 kVA", "code": 225000 }, { "name": "250 kVA", "code": 250000 }, { "name": "300 kVA", "code": 300000 }, { "name": "333 kVA", "code": 333000 }, { "name": "342 kVA", "code": 342000 }, { "name": "375 kVA", "code": 375000 }, { "name": "416 kVA", "code": 416000 }, { "name": "450 kVA", "code": 450000 }, { "name": "500 kVA", "code": 500000 }, { "name": "666 kVA", "code": 666000 }, { "name": "750 kVA", "code": 750000 }, { "name": "833 kVA", "code": 833000 }, { "name": "966 kVA", "code": 966000 }, { "name": "1000 kVA", "code": 1000000 }, { "name": "1250 kVA", "code": 1250000 }, { "name": "1500 kVA", "code": 1500000 }, { "name": "1750 kVA", "code": 1750000 }, { "name": "2000 kVA", "code": 2000000 }, { "name": "2500 kVA", "code": 2500000 }, { "name": "3000 kVA", "code": 3000000 }, { "name": "3500 kVA", "code": 3500000 }, { "name": "3750 kVA", "code": 3750000 }, { "name": "5000 kVA", "code": 5000000 }, { "name": "7000 kVA", "code": 7000000 }, { "name": "7500 kVA", "code": 7500000 }, { "name": "10000 kVA", "code": 10000000 }, { "name": "12000 kVA", "code": 12000000 }, { "name": "4000 kVA", "code": 4000000 }, { "name": "4250 kVA", "code": 4250000 }, { "name": "4500 kVA", "code": 4500000 }, { "name": "4750 kVA", "code": 4750000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": 60, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": 2, "nominalvoltage": 12470, "nominalvoltagelg": 7200, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": "_CENTERTAPLOADMIX", "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 38, "name": "Medium Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware", "description": "Asset Types for equipment that connects electric lines to towers and poles", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Damper", "code": 834 }, { "name": "Spacer", "code": 836 }, { "name": "Aerial Marker", "code": 837 }, { "name": "Buried Cable Marker", "code": 838 }, { "name": "Submerged Cable Marker", "code": 839 }, { "name": "Overhead Water Crossing Marker", "code": 840 }, { "name": "Airflow Spoiler", "code": 841 }, { "name": "Bird Diverter", "code": 842 }, { "name": "Line Weight", "code": 843 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Cable_Hardware_Type", "description": "Types of cable hardward", "codedValues": [ { "name": "Brace", "code": 1 }, { "name": "Suspension", "code": 2 }, { "name": "Line Post", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 62, "name": "Medium Voltage Line Hardware" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "Transformer Winding MV", "code": 873 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 47, "name": "Medium Voltage Transformer Winding" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker", "description": "Asset Types for Low Voltage Circuit Breakers", "codedValues": [ { "name": "Circuit Breaker", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Circuit Breaker LV", "code": 471 }, { "name": "DC Circuit Breaker LV", "code": 472 }, { "name": "AC Circuit Breaker LV - Controller", "code": 473 }, { "name": "DC Circuit Breaker LV - Controller", "code": 474 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps", "description": "Low Voltage Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps", "description": "Low Voltage Circuit Breaker Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "600 A", "code": 600 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 40, "name": "Low Voltage Circuit Breaker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Control_Unit", "description": "Low Voltage Controller", "codedValues": [ { "name": "Control Unit", "code": 0 }, { "name": "Control Unit LV", "code": 241 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Closing_Mode", "description": "Device Closing Mode", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Normal Reclose", "code": 1 }, { "name": "Remote Block", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 13, "name": "Low Voltage Control Unit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Fuse", "description": "Low Voltage Fuse", "codedValues": [ { "name": "Fuse", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "Service Fuse Load Break LV", "code": 259 }, { "name": "Service Fuse Disconnect LV", "code": 260 }, { "name": "AC Overhead Fuse LV", "code": 261 }, { "name": "AC Underground Fuse LV", "code": 262 }, { "name": "DC Overhead Fuse LV", "code": 263 }, { "name": "DC Underground Fuse LV", "code": 264 }, { "name": "AC Overhead Load Break Fuse LV", "code": 265 }, { "name": "AC Overhead Fuse LV - Controller", "code": 266 }, { "name": "AC Underground Load Break Fuse LV", "code": 267 }, { "name": "AC Underground Fuse LV - Controller", "code": 268 }, { "name": "DC Overhead Fuse LV - Controller", "code": 269 }, { "name": "DC Underground Fuse LV - Controller", "code": 270 }, { "name": "AC Overhead Cutout Load Break Disconnect Fuse LV", "code": 271 }, { "name": "AC Overhead Cutout Load Break Fuse LV - Controller", "code": 272 }, { "name": "AC Overhead Cutout Disconnect Fuse LV - Controller", "code": 273 }, { "name": "AC Overhead Cutout Load Break Fuse LV", "code": 274 }, { "name": "Station Disconnect Fuse LV", "code": 275 }, { "name": "Station Load Break Fuse LV", "code": 276 }, { "name": "Station Load Break Disconnect Fuse LV", "code": 277 }, { "name": "Station Disconnect Fuse LV - Controller", "code": 278 }, { "name": "Station Load Break Fuse LV - Controller", "code": 279 }, { "name": "Station Load Break Disconnect Fuse LV - Controller", "code": 280 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Type", "description": "List of valid fuse types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Kearney A", "code": 17 }, { "name": "Kearney B", "code": 18 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Link_Type", "description": "Types of fuse links", "codedValues": [ { "name": "K", "code": 10 }, { "name": "T", "code": 11 }, { "name": "MS", "code": 12 }, { "name": "QH", "code": 13 }, { "name": "Standard", "code": 14 }, { "name": "SloFast", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 14, "name": "Low Voltage Fuse" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Generation", "description": "Low Voltage Generation", "codedValues": [ { "name": "Generation", "code": 0 }, { "name": "Battery LV", "code": 281 }, { "name": "Generator LV", "code": 283 }, { "name": "Residential Photovoltaic Solar LV", "code": 284 }, { "name": "Wind Turbine LV", "code": 285 }, { "name": "AC Wave LV", "code": 286 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Generator_Control_Type", "description": "Generator Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed", "code": 1 }, { "name": "Voltage", "code": 2 }, { "name": "Swing", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "codedValue", "name": "WS1_Electric_Generation_Pole_Count", "description": "Generator Pole count", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2 Pole", "code": 2 }, { "name": "4 Pole", "code": 4 }, { "name": "6 Pole", "code": 6 }, { "name": "8 Pole", "code": 8 }, { "name": "10 Pole", "code": 10 }, { "name": "12 Pole", "code": 12 }, { "name": "14 Pole", "code": 14 }, { "name": "16 Pole", "code": 16 }, { "name": "18 Pole", "code": 18 }, { "name": "20 Pole", "code": 20 }, { "name": "40 Pole", "code": 40 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Fuel_Type", "description": "Generator Fuel Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Ethenaol", "code": 1 }, { "name": "Gasoline", "code": 2 }, { "name": "Hydrogen", "code": 3 }, { "name": "Natural Gas", "code": 4 }, { "name": "Hydro", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 15, "name": "Low Voltage Generation" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Lighting", "description": "Low Voltage Lighting", "codedValues": [ { "name": "Lighting", "code": 0 }, { "name": "Floodlight LV", "code": 301 }, { "name": "Streetlight LV", "code": 302 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Light_Housing_Type", "description": "Light Housing Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cobra Head", "code": 1 }, { "name": "Security", "code": 2 }, { "name": "Roadway", "code": 3 }, { "name": "Flood", "code": 4 }, { "name": "Decorative", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Street_Bulb_Type", "description": "List of valid bulb types for streetlights", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "High Pressure Sodium (HPS)", "code": 30 }, { "name": "Low Pressure Sodium (LPS)", "code": 31 }, { "name": "Metal Halide (MH)", "code": 32 }, { "name": "Mercury Vapor (MV)", "code": 33 }, { "name": "Halogen (HG)", "code": 34 }, { "name": "Light Emitting Diode (LED)", "code": 35 }, { "name": "Phosphor-Converted Amber LED (PCA)", "code": 36 }, { "name": "Narrow-Band Amber LED (NBA)", "code": 37 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "lightsphotoeye": {"type": "inherited"}, "lightswattage": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 16, "name": "Low Voltage Lighting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay", "description": "Low Voltage Line Monitor and Relay", "codedValues": [ { "name": "Line Monitor and Relay", "code": 0 }, { "name": "Fault Indicator LV", "code": 321 }, { "name": "Load Monitor LV", "code": 322 }, { "name": "Relay LV", "code": 323 }, { "name": "Instrument Transformer LV", "code": 324 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "range", "name": "WS1_Electric_Voltage_Offset", "description": "Voltage Offset Range", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_RTU_Data_Type", "description": "RTU Data collector data format", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Analog", "code": 1 }, { "name": "Digital", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Maximum_Voltage_Change", "description": "Maximum Voltage Change", "range": [ 0, 10000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "p2sphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2tphaseshift": { "type": "range", "name": "WS1_Electric_Phase_Whole_Degrees_Positive", "description": "Degrees in whole units", "range": [ 0, 180 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Short_Percent_Range", "description": "Range domain for setting a percentage in whole numbers", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 17, "name": "Low Voltage Line Monitor and Relay" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Motor", "description": "Low Voltage Motor", "codedValues": [ { "name": "Motor", "code": 0 }, { "name": "Single Phase Motor LV", "code": 341 }, { "name": "Three Phase Motor LV", "code": 342 }, { "name": "DC Motor LV", "code": 343 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Motor_Type", "description": "Motor Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Induction", "code": 1 }, { "name": "Synchronous", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Generation_ANSI_Group_Code", "description": "ANSI Generation Group Code", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Group 2", "code": 2 }, { "name": "Group 3", "code": 3 }, { "name": "Group 4", "code": 4 }, { "name": "Group 5", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Motor_Assistance_Type", "description": "Motor Starting Assistance Types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Auto Transformer", "code": 1 }, { "name": "Capacitor", "code": 2 }, { "name": "Inductor", "code": 3 }, { "name": "Inductor & Resistor", "code": 4 }, { "name": "Resistor", "code": 5 }, { "name": "Star-Delta", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 18, "name": "Low Voltage Motor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Network_Protection", "description": "Low Voltage Network Protection", "codedValues": [ { "name": "Network Protector", "code": 0 }, { "name": "Network Protector LV", "code": 361 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Interrupting_Amps", "description": "List of valid interrupting amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "30 A", "code": 30 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 }, { "name": "1000 A", "code": 1000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Fuse_Continuous_Amps", "description": "List of valid continuous amps for a fuse", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "3 A", "code": 3 }, { "name": "7 A", "code": 7 }, { "name": "10 A", "code": 10 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "25 A", "code": 25 }, { "name": "30 A", "code": 30 }, { "name": "40 A", "code": 40 }, { "name": "50 A", "code": 50 }, { "name": "100 A", "code": 100 }, { "name": "200 A", "code": 200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 19, "name": "Low Voltage Network Protection" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Conversion", "description": "Low Voltage Power Conversion", "codedValues": [ { "name": "Power Conversion", "code": 0 }, { "name": "Single Phase Inverter LV", "code": 381 }, { "name": "Single Phase Rectifier LV", "code": 382 }, { "name": "Three Phase Inverter LV", "code": 383 }, { "name": "Three Phase Rectifier LV", "code": 384 }, { "name": "Single Phase Bidirectional LV", "code": 386 }, { "name": "Three Phase Bidirectional LV", "code": 387 }, { "name": "Wave Trap LV", "code": 390 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_DC_Low_Voltage_Nominal_Voltage", "description": "DC Nominal Low Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "36 V", "code": 36 }, { "name": "48 V", "code": 48 }, { "name": "60 V", "code": 60 }, { "name": "68 V", "code": 68 }, { "name": "72 V", "code": 72 }, { "name": "110 V", "code": 110 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "160 V", "code": 160 }, { "name": "380 V", "code": 380 }, { "name": "500 V", "code": 500 }, { "name": "575 V", "code": 575 }, { "name": "600 V", "code": 600 }, { "name": "750 V", "code": 750 }, { "name": "1000 V", "code": 1000 }, { "name": "1500 V", "code": 1500 }, { "name": "400 V", "code": 400 }, { "name": "690 V", "code": 690 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 20, "name": "Low Voltage Power Conversion" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting", "description": "Low Voltage Power Factor Correcting", "codedValues": [ { "name": "Power Factor Correcting", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "Mobile Harmonic Filter LV", "code": 401 }, { "name": "Mobile Reactor LV", "code": 402 }, { "name": "Overhead Capacitor LV", "code": 403 }, { "name": "Overhead Harmonic Filter LV", "code": 404 }, { "name": "Overhead Reactor LV", "code": 405 }, { "name": "Pad Mounted Capacitor LV", "code": 406 }, { "name": "Pad Mounted Harmonic Filter LV", "code": 407 }, { "name": "Pad Mounted Reactor LV", "code": 408 }, { "name": "Station Capacitor LV", "code": 409 }, { "name": "Station Harmonic Filter LV", "code": 410 }, { "name": "Station Reactor LV", "code": 411 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Electric_Configuration_Type", "description": "How equiment is configuration, in Series or Shunt", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Shunt", "code": 1 }, { "name": "Series", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Device_Resistance_Range", "description": "Range of valid resistance values", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_Capacitory_Type", "description": "Type of Capacitor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "kVA-PF", "code": 1 }, { "name": "AMP-PF", "code": 2 }, { "name": "kW-kVAR", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "upperrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lowerrange": { "type": "codedValue", "name": "WS1_Electric_Temperature_F", "description": "Temperature in Fahrenheit", "codedValues": [ { "name": "32 F", "code": 0 }, { "name": "167 F", "code": 75 }, { "name": "194 F", "code": 90 }, { "name": "302 F", "code": 150 }, { "name": "356 F", "code": 180 }, { "name": "410 F", "code": 210 }, { "name": "446 F", "code": 230 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_PF_Control_Type", "description": "Power Factor Control Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Current", "code": 1 }, { "name": "Manual", "code": 2 }, { "name": "Power Factor", "code": 3 }, { "name": "VAR", "code": 4 }, { "name": "Tempature", "code": 5 }, { "name": "Time", "code": 6 }, { "name": "Reactive Current", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_KVAR", "description": "Domain fo rvalid kVAR rating for Low Voltage Capacitors", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "25 kvar", "code": 25000 }, { "name": "50 kvar", "code": 50000 }, { "name": "75 kvar", "code": 75000 }, { "name": "100 kvar", "code": 100000 }, { "name": "125 kvar", "code": 125000 }, { "name": "150 kvar", "code": 150000 }, { "name": "175 kvar", "code": 175000 }, { "name": "200 kvar", "code": 200000 }, { "name": "225 kvar", "code": 225000 }, { "name": "250 kvar", "code": 250000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 21, "name": "Low Voltage Power Factor Correcting" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Service", "description": "Low Voltage Service", "codedValues": [ { "name": "Service", "code": 0 }, { "name": "Single Phase Commercial LV", "code": 421 }, { "name": "Single Phase Residential LV", "code": 422 }, { "name": "Three Phase Commercial LV", "code": 423 }, { "name": "Three Phase Residential LV", "code": 424 }, { "name": "Unmetered Load LV", "code": 425 }, { "name": "DC Commercial LV", "code": 426 }, { "name": "Low Voltage Premise LV", "code": 427 }, { "name": "Car Charger LV", "code": 428 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "ratedpower": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "iscritical": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "centertap": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": "_CENTERTAPLOADMIX", "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 22, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Switch", "description": "Low Voltage Switch", "codedValues": [ { "name": "Switch", "code": 0 }, { "name": "AC Overhead", "code": 1 }, { "name": "AC Underground", "code": 2 }, { "name": "AC Station", "code": 3 }, { "name": "AC Overhead Bank", "code": 4 }, { "name": "AC Underground Bank", "code": 5 }, { "name": "AC Station Bank", "code": 6 }, { "name": "DC Overhead", "code": 11 }, { "name": "DC Underground", "code": 12 }, { "name": "DC Station", "code": 13 }, { "name": "DC Overhead Bank", "code": 14 }, { "name": "DC Underground Bank", "code": 15 }, { "name": "DC Station Bank", "code": 16 }, { "name": "AC Station Disconnect LV", "code": 431 }, { "name": "AC Station Load Break LV", "code": 432 }, { "name": "AC Station Load Break Disconnect LV", "code": 433 }, { "name": "AC Station Disconnect LV - Controller", "code": 434 }, { "name": "AC Station Load Break LV - Controller", "code": 435 }, { "name": "AC Station Load Break Disconnect LV - Controller", "code": 436 }, { "name": "Overhead AC Load Break LV", "code": 441 }, { "name": "Overhead AC Disconnect LV", "code": 442 }, { "name": "Overhead DC Load Break LV", "code": 443 }, { "name": "Overhead DC Disconnect LV", "code": 444 }, { "name": "Underground AC Load Break LV", "code": 445 }, { "name": "Underground AC Disconnect LV", "code": 446 }, { "name": "Underground DC Load Break LV", "code": 447 }, { "name": "Underground DC Disconnect LV", "code": 448 }, { "name": "Indoor AC Load Break LV", "code": 449 }, { "name": "Indoor AC Disconnect LV", "code": 450 }, { "name": "Indoor DC Load Break LV", "code": 451 }, { "name": "Indoor DC Disconnect LV", "code": 452 }, { "name": "Source Selectable Switch LV", "code": 453 }, { "name": "Overhead Jumper LV", "code": 454 }, { "name": "DC Station LV", "code": 456 }, { "name": "AC Station Bypass LV", "code": 457 }, { "name": "AC Recloser LV", "code": 458 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": { "type": "codedValue", "name": "WS1_Electric_Device_Switch_Manufacturer", "description": "All Electric Device Switch Manufacturer", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ABB/Westinghouse", "code": 1 }, { "name": "G&W Electric", "code": 16 }, { "name": "General Electric", "code": 17 }, { "name": "Royal Switchgear Mfg Co Inc", "code": 44 }, { "name": "S&C", "code": 45 }, { "name": "McGraw Edison", "code": 62 }, { "name": "AB Chance", "code": 71 }, { "name": "ABB T&D", "code": 72 }, { "name": "Cooper", "code": 73 }, { "name": "Eisler Engineering", "code": 74 }, { "name": "Elastimold", "code": 75 }, { "name": "Hi-Tech Fuses", "code": 76 }, { "name": "Kearney", "code": 77 }, { "name": "RTE", "code": 88 }, { "name": "Southern State Equipment", "code": 94 }, { "name": "USCO Power Equipment", "code": 105 }, { "name": "Wagner", "code": 108 }, { "name": "Action Trans", "code": 110 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tripmode": { "type": "codedValue", "name": "WS1_Electric_Trip_Type", "description": "Valid types of tripping", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trip Only", "code": 10 }, { "name": "Trip and Lockout", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "optype": { "type": "codedValue", "name": "WS1_Electric_Switch_Breaking_Medium", "description": "Switch Arc Breaking Medium", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air", "code": 1 }, { "name": "CO2", "code": 2 }, { "name": "Gas", "code": 3 }, { "name": "Hybrid", "code": 4 }, { "name": "Oil", "code": 5 }, { "name": "Vaccum", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "minimumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Interrupting_Amps", "description": "Low Voltage Switch Interrupting Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "10 kA", "code": 10000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Switch_Continuous_Amps", "description": "Low Voltage Switch Continuous Amps", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "15 A", "code": 15 }, { "name": "20 A", "code": 20 }, { "name": "30 A", "code": 30 }, { "name": "45 A", "code": 45 }, { "name": "50 A", "code": 50 }, { "name": "60 A", "code": 60 }, { "name": "100 A", "code": 100 }, { "name": "125 A", "code": 125 }, { "name": "200 A", "code": 200 }, { "name": "225 A", "code": 225 }, { "name": "300 A", "code": 300 }, { "name": "320 A", "code": 320 }, { "name": "800 A", "code": 800 }, { "name": "1200 A", "code": 1200 }, { "name": "2500 A", "code": 2500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "fieldoperation": {"type": "inherited"}, "operatingmechanism": {"type": "inherited"}, "isriser": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 23, "name": "Low Voltage Switch" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer", "description": "Low Voltage Transformer", "codedValues": [ { "name": "Transformer", "code": 0 }, { "name": "Single Phase - LV->LV", "code": 461 }, { "name": "Three Phase - LV->LV", "code": 462 }, { "name": "Three Winding - LV->LV-LV", "code": 463 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": {"type": "inherited"}, "nominalvoltagelg": {"type": "inherited"}, "secondaryvoltagelinetoline": {"type": "inherited"}, "secondaryvoltagelinetoground": {"type": "inherited"}, "secondarygrounding": {"type": "inherited"}, "tertiaryvoltagelinetoline": {"type": "inherited"}, "tertiaryvoltagelinetoground": {"type": "inherited"}, "tertiarygrounding": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "peakload": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Watts", "description": "", "range": [ 0, 100000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "offpeakload": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Watts", "description": "", "range": [ 0, 20000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Transformer_VA", "description": "Low Voltage Transformer kVA", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "0.5 kVA", "code": 500 }, { "name": "0.75 kVA", "code": 750 }, { "name": "1 kVA", "code": 1000 }, { "name": "1.5 kVA", "code": 1500 }, { "name": "2 kVA", "code": 2000 }, { "name": "3 kVA", "code": 3000 }, { "name": "5 kVA", "code": 5000 }, { "name": "7.5 kVA", "code": 7500 }, { "name": "10 kVA", "code": 10000 }, { "name": "15 kVA", "code": 15000 }, { "name": "25 kVA", "code": 25000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Low_Voltage_Load_Loss", "description": "Valid Load Loss Range for Low Voltage", "range": [ 0, 100 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "powerfactor": { "type": "range", "name": "WS1_Electric_Power_Factor_Range", "description": "Power Factor valid value range", "range": [ 0, 1 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "primarytotertiaryvectorygroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 24, "name": "Low Voltage Transformer" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Wire_Connector", "description": "Low Voltage Connectors", "codedValues": [ { "name": "Wire Connector", "code": 0 }, { "name": "Ring Terminal LV", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "planoperatingstatus": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "winteroperatingstatus": {"type": "inherited"}, "summeroperatingstatus": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": 0, "normaloperatingstatus": 0, "winteroperatingstatus": 0, "summeroperatingstatus": 0, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 44, "name": "Low Voltage Wire Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Regulator", "description": "Asset Types for Low Voltage Regulating Equipment", "codedValues": [ { "name": "Regulator", "code": 0 }, { "name": "AC Single Phase LV", "code": 141 }, { "name": "AC Three Phase LV", "code": 142 }, { "name": "DC Regulator LV", "code": 143 }, { "name": "Network Load Balancer LV", "code": 144 }, { "name": "Frequency Converter LV", "code": 145 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": {"type": "inherited"}, "manufacturer": {"type": "inherited"}, "grounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangermaximumchange": { "type": "range", "name": "WS1_Electric_Tap_Maximum_Change", "description": "Valid Tap Maxium Change Range", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerlowerbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumboost": { "type": "range", "name": "WS1_Electric_Buck_Boost_Rate", "description": "Valid Buck and Boost Rates", "range": [ -10, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0xmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z1psimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x0r0impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "x1r1impedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "z0pmimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarygroundimpedance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "gridsidecouplinginductance": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "remotecontrollerindicator": { "type": "codedValue", "name": "WS1_Electric_Remoted_Controlled", "description": "List of remote control types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "No", "code": 2 }, { "name": "All Phases", "code": 4 }, { "name": "Individual Phase", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "equipmentype": { "type": "codedValue", "name": "WS1_Electric_XFR_Type", "description": "Transformer Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Dry", "code": 1 }, { "name": "Oil Filled", "code": 2 }, { "name": "Pumped Oil", "code": 3 }, { "name": "Air Cooled", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "tapsandpoles": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "directional": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "primarygroundimpedance2": { "type": "range", "name": "WS1_Electric_Impedance_Range", "description": "Valid Impendance Range", "range": [ 0, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "reversetrip": {"type": "inherited"}, "timedelay": {"type": "inherited"}, "tripcount": {"type": "inherited"}, "tapmaxchange": { "type": "range", "name": "WS1_Electric_Taps_Range", "description": "Valid Taps Range", "range": [ 0, 32 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "optype": { "type": "codedValue", "name": "WS1_Electric_Regulator_Operation_Type", "description": "Regulator Operation Type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fixed Tap", "code": 1 }, { "name": "Regulator Terminal", "code": 2 }, { "name": "R-X settings", "code": 3 }, { "name": "Load center", "code": 4 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ratedpower": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Regulator_VA", "description": "Low Voltage Regulators Volt Amps", "codedValues": [ { "name": "600 VA", "code": 600 }, { "name": "1200 VA", "code": 1200 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangepercent": {"type": "inherited"}, "noloadloss": { "type": "range", "name": "WS1_Electric_Medium_Voltage_Load_Loss", "description": "Valid Load Loss Range for Medium Voltage", "range": [ 0, 1000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ctratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ptratio": { "type": "codedValue", "name": "WS1_Electric_Winding_Ratio_Long", "description": "Transformer and Regulator winding ratios", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "50:5", "code": 50 }, { "name": "60:5", "code": 60 }, { "name": "75:5", "code": 75 }, { "name": "80:5", "code": 80 }, { "name": "100:5", "code": 100 }, { "name": "125:5", "code": 125 }, { "name": "150:5", "code": 150 }, { "name": "200:5", "code": 200 }, { "name": "250:5", "code": 250 }, { "name": "300:5", "code": 300 }, { "name": "400:5", "code": 400 }, { "name": "500:5", "code": 500 }, { "name": "600:5", "code": 600 }, { "name": "800:5", "code": 800 }, { "name": "1000:5", "code": 1000 }, { "name": "1200:5", "code": 1200 }, { "name": "1500:5", "code": 1500 }, { "name": "1600:5", "code": 1600 }, { "name": "2000:5", "code": 2000 }, { "name": "3000:5", "code": 3000 }, { "name": "4000:5", "code": 4000 }, { "name": "6000:5", "code": 6000 }, { "name": "8000:5", "code": 8000 }, { "name": "5:5", "code": 5 }, { "name": "10:5", "code": 10 }, { "name": "15:5", "code": 15 }, { "name": "20:5", "code": 20 }, { "name": "25:5", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumbuck": { "type": "range", "name": "WS1_Electric_Regulator_Maximum_Buck_Boost", "description": "Minimum and Maximum Regulator Buck percent", "range": [ 0, 20 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "buckbandwidth": { "type": "range", "name": "WS1_Electric_Voltage_Bandwidth", "description": "Voltage Bandwidth Percentage", "range": [ -5000, 5000 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerupperbandwidth": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "loadtapchangerminimumchange": { "type": "range", "name": "WS1_Electric_Load_Tap_Bandwidth", "description": "Valid Load Tap Bandwidth", "range": [ 0, 10 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "starthour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "stophour": { "type": "range", "name": "WS1_Electric_Hour", "description": "Hour of Operation", "range": [ 1, 24 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "coolingtype": { "type": "codedValue", "name": "WS1_Electric_Transformer_Cooling", "description": "Transformer cooling type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Air Natural (AN)", "code": 1 }, { "name": "Air Blast", "code": 2 }, { "name": "Oil Natural/Air Natural (ONAN)", "code": 3 }, { "name": "Oil Natural/Air Forced (ONAF)", "code": 4 }, { "name": "Oil Forced/Air Forced (OFAF)", "code": 5 }, { "name": "Oil Forced/Water Forced (OFWF)", "code": 6 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "inparallel": { "type": "codedValue", "name": "WS1_Yes_No", "description": "Valid Yes, No values", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Yes", "code": 1 }, { "name": "No", "code": 2 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "primarytosecondaryvectorgroup": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "hasarrester": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 45, "name": "Low Voltage Regulator" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding", "description": "Asset Types for Transformer Windings", "codedValues": [ { "name": "Transformer Winding", "code": 0 }, { "name": "AC Transformer Winding LV", "code": 874 }, { "name": "DC Transformer Winding LV", "code": 875 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISSUBNETWORKCONTROLLER": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "TIERNAME": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasessubstituted": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Substitution", "description": "Phase Substitution Values for Low Voltage", "codedValues": [ { "name": "abc->000", "code": 0 }, { "name": "abc->00a", "code": 4 }, { "name": "abc->00b", "code": 2 }, { "name": "abc->00c", "code": 1 }, { "name": "abc->0a0", "code": 32 }, { "name": "abc->0aa", "code": 36 }, { "name": "abc->0ab", "code": 34 }, { "name": "abc->0ac", "code": 33 }, { "name": "abc->0b0", "code": 16 }, { "name": "abc->0ba", "code": 20 }, { "name": "abc->0bb", "code": 18 }, { "name": "abc->0bc", "code": 17 }, { "name": "abc->0c0", "code": 8 }, { "name": "abc->0ca", "code": 12 }, { "name": "abc->0cb", "code": 10 }, { "name": "abc->0cc", "code": 9 }, { "name": "abc->a00", "code": 256 }, { "name": "abc->a0a", "code": 260 }, { "name": "abc->a0b", "code": 258 }, { "name": "abc->a0c", "code": 257 }, { "name": "abc->aa0", "code": 288 }, { "name": "abc->aaa", "code": 292 }, { "name": "abc->aab", "code": 290 }, { "name": "abc->aac", "code": 289 }, { "name": "abc->ab0", "code": 272 }, { "name": "abc->aba", "code": 276 }, { "name": "abc->abb", "code": 274 }, { "name": "abc->abc", "code": 273 }, { "name": "abc->ac0", "code": 264 }, { "name": "abc->aca", "code": 268 }, { "name": "abc->acb", "code": 266 }, { "name": "abc->acc", "code": 265 }, { "name": "abc->b00", "code": 128 }, { "name": "abc->b0a", "code": 132 }, { "name": "abc->b0b", "code": 130 }, { "name": "abc->b0c", "code": 129 }, { "name": "abc->ba0", "code": 160 }, { "name": "abc->baa", "code": 164 }, { "name": "abc->bab", "code": 162 }, { "name": "abc->bac", "code": 161 }, { "name": "abc->bb0", "code": 144 }, { "name": "abc->bba", "code": 148 }, { "name": "abc->bbb", "code": 146 }, { "name": "abc->bbc", "code": 145 }, { "name": "abc->bc0", "code": 136 }, { "name": "abc->bca", "code": 140 }, { "name": "abc->bcb", "code": 138 }, { "name": "abc->bcc", "code": 137 }, { "name": "abc->c00", "code": 64 }, { "name": "abc->c0a", "code": 68 }, { "name": "abc->c0b", "code": 66 }, { "name": "abc->c0c", "code": 65 }, { "name": "abc->ca0", "code": 96 }, { "name": "abc->caa", "code": 100 }, { "name": "abc->cab", "code": 98 }, { "name": "abc->cac", "code": 97 }, { "name": "abc->cb0", "code": 80 }, { "name": "abc->cba", "code": 84 }, { "name": "abc->cbb", "code": 82 }, { "name": "abc->cbc", "code": 81 }, { "name": "abc->cc0", "code": 72 }, { "name": "abc->cca", "code": 76 }, { "name": "abc->ccb", "code": 74 }, { "name": "abc->ccc", "code": 73 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "secondaryvoltagelinetoline": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondaryvoltagelinetoground": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "secondarygrounding": { "type": "codedValue", "name": "WS1_Electric_Ground_Configuration", "description": "List of valid ground types for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Grounded Wye", "code": 1 }, { "name": "Wye", "code": 2 }, { "name": "Delta", "code": 3 }, { "name": "Grounded Delta", "code": 4 }, { "name": "Direct Current", "code": 5 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "symbolrotation": {"type": "inherited"}, "p2sphaseshift": {"type": "inherited"}, "p2tphaseshift": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISSUBNETWORKCONTROLLER": 0, "ISCONNECTED": 2, "SUBNETWORKCONTROLLERNAME": "Unknown", "TIERNAME": 0, "TIERRANK": 0, "TERMINALCONFIGURATION": "Default", "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "planoperatingstatus": null, "normaloperatingstatus": null, "winteroperatingstatus": null, "summeroperatingstatus": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasessubstituted": null, "phasefrequency": null, "numphasesconstructed": null, "designtype": null, "manufacturer": null, "grounding": null, "nominalvoltage": null, "nominalvoltagelg": null, "secondaryvoltagelinetoline": null, "secondaryvoltagelinetoground": null, "secondarygrounding": null, "tertiaryvoltagelinetoline": null, "tertiaryvoltagelinetoground": null, "tertiarygrounding": null, "maxvoltage": null, "maxoperatingvoltage": null, "compatibleunit": null, "lifecyclestatus": 2, "model": null, "loadtapchangermaximumchange": null, "loadtapchangerlowerbandwidth": null, "maximumboost": null, "z0psimpedance": null, "z0xmimpedance": null, "z1psimpedance": null, "x0r0impedance": null, "x1r1impedance": null, "z0pmimpedance": null, "primarygroundimpedance": null, "gridsidecouplinginductance": null, "remotecontrollerindicator": null, "equipmentype": null, "tripmode": null, "tapsandpoles": null, "directional": null, "peakload": null, "offpeakload": null, "district": null, "installdate": null, "retireddate": null, "inservicedate": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "notes": null, "symbolrotation": null, "upperrange": null, "lowerrange": null, "primarygroundimpedance2": null, "reversetrip": null, "p2sphaseshift": null, "p2tphaseshift": null, "timedelay": null, "tripcount": null, "tapmaxchange": null, "optype": null, "maximumpower": null, "minimumpower": null, "ratedpower": null, "loadtapchangepercent": null, "noloadloss": null, "secondarygroundimpedance": null, "ctratio": null, "ptratio": null, "maximumbuck": null, "secondarygroundimpedance2": null, "buckbandwidth": null, "loadtapchangerupperbandwidth": null, "loadtapchangerminimumchange": null, "starthour": null, "stophour": null, "powerfactor": null, "coolingtype": null, "inparallel": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "primarytosecondaryvectorgroup": null, "primarytotertiaryvectorygroup": null, "constructionstatus": 6, "fieldoperation": null, "operatingmechanism": null, "primaryphaseshift": null, "sectionid": null, "TERMINALID": null, "iscritical": null, "isriser": null, "hasarrester": null, "isvalidloop": null, "WithstandRating": null, "centertap": null, "sectionalizercabinetID": null, "transformerlocationnumber": null, "meterform": null, "meterbase": null, "meterclass": null, "meterloadmis": null, "metergisid": null, "workorder": null, "lightsphotoeye": null, "lightswattage": null, "birthyear": null, "rel_guid": null, "meterserialsurvalent": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 46, "name": "Low Voltage Transformer Winding" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1757937024000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 430, "name": "Secondary Conductor", "type": "Feature Layer", "description": "

The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within any container feature that has rules allowing it.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 400, "name": "Electric" }, "subLayers": [], "minScale": 24000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "ASSETGROUP", "field2": "ASSETTYPE", "uniqueValueInfos": [ { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "2,20", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "6,100", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,160", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,161", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,162", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,165", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,166", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,167", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "37,102", "label": "Underground" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 252, 240, 255 ], "toColor": [ 212, 252, 240, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 179, 252, 255 ], "toColor": [ 252, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 183, 182, 255 ], "toColor": [ 252, 183, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 201, 252, 255 ], "toColor": [ 179, 201, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 238, 182, 255 ], "toColor": [ 252, 238, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 184, 252, 189, 255 ], "toColor": [ 184, 252, 189, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 240, 255 ], "toColor": [ 252, 212, 240, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 234, 215, 255 ], "toColor": [ 252, 234, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 228, 252, 255 ], "toColor": [ 179, 228, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 221, 202, 252, 255 ], "toColor": [ 221, 202, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 237, 252, 210, 255 ], "toColor": [ 237, 252, 210, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 217, 255 ], "toColor": [ 252, 184, 217, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 218, 252, 179, 255 ], "toColor": [ 218, 252, 179, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 646553.9354125783, "ymin": 639229.2276111543, "xmax": 707061.4210246615, "ymax": 695982.9940246567, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "assetgroup", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "WS1_Lifecycle_Status_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Proposed and In Service", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "In Service and Planned Removal", "code": 6 }, { "name": "Maintenance", "code": 7 }, { "name": "Design", "code": 11 }, { "name": "Abandoned", "code": 12 }, { "name": "Removed", "code": 13 }, { "name": "Retired", "code": 14 }, { "name": "NA", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "ownedby", "type": "esriFieldTypeSmallInteger", "alias": "Owned By", "domain": { "type": "codedValue", "name": "WS1_Asset_Owner", "description": "The owner of the asset", "codedValues": [ { "name": "Our Agency", "code": 1 }, { "name": "Private", "code": 2 }, { "name": "Other", "code": 100 }, { "name": "Idaho Falls Power", "code": 3 }, { "name": "Rocky Mountain Power", "code": 4 }, { "name": "Century Link", "code": 5 }, { "name": "IF Parks & Recreation", "code": 6 }, { "name": "Idaho Department of Transportation", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "SHAPE.STLength()", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S183_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "WithstandRating": {"type": "inherited"}, "conductorsheaththickness": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Neutral", "description": "Neutral", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Bare", "code": 200 }, { "name": "Overhead Shielded", "code": 201 }, { "name": "Underground Shielded", "code": 202 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Neutral_Material", "description": "List of valid neutral materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Steel", "code": 506 }, { "name": "Aluminum", "code": 515 }, { "name": "All Aluminum Conductor", "code": 516 }, { "name": "All Aluminum Steel Reinforced", "code": 517 }, { "name": "Copper", "code": 525 }, { "name": "Hard Drawn Copper", "code": 526 }, { "name": "Soft Drawn Copper", "code": 527 }, { "name": "Stranded Copper", "code": 528 }, { "name": "Copper Weld", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 11, "name": "Neutral Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Ground", "description": "Ground", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Covered Ground", "code": 221 }, { "name": "Bare Ground", "code": 222 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 12, "name": "Ground Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor", "description": "High Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead HV", "code": 20 }, { "name": "DC Overhead HV", "code": 23 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": {"type": "inherited"}, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 2, "name": "High Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor", "description": "High VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground HV", "code": 22 }, { "name": "DC Underground HV", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 31, "name": "High Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor", "description": "High VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible HV", "code": 21 }, { "name": "DC Submersible HV", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 32, "name": "High Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar", "description": "High Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Station Single Phase HV", "code": 1 }, { "name": "AC Station Three Phase HV", "code": 2 }, { "name": "DC Station HV", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 1, "name": "High Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector", "description": "High Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector HV", "code": 40 }, { "name": "DC Connector HV", "code": 41 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 3, "name": "High Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire", "description": "High Voltage Static Wire", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 60 }, { "name": "Single", "code": 61 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 4, "name": "High Voltage Static Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service", "description": "High Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service HV", "code": 260 }, { "name": "AC Underground Service HV", "code": 261 }, { "name": "DC Overhead Service HV", "code": 262 }, { "name": "DC Underground Service HV", "code": 263 }, { "name": "AC Submersible Service HV", "code": 264 }, { "name": "DC Submersible Service HV", "code": 265 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 15, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor", "description": "Medium Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase MV", "code": 160 }, { "name": "Overhead Three Phase MV", "code": 161 }, { "name": "Overhead Two Phase MV", "code": 162 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 9, "name": "Medium Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor", "description": "Medium VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Underground Single Phase MV", "code": 165 }, { "name": "Underground Three Phase MV", "code": 166 }, { "name": "Underground Two Phase MV", "code": 167 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 34, "name": "Medium Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor", "description": "Medium VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Submersible Single Phase MV", "code": 163 }, { "name": "Submersible Three Phase MV", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 35, "name": "Medium Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar", "description": "Medium Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cabinet Single Phase MV", "code": 140 }, { "name": "Cabinet Three Phase MV", "code": 141 }, { "name": "Station Single Phase MV", "code": 142 }, { "name": "Station Three Phase MV", "code": 143 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 8, "name": "Medium Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector", "description": "Medium Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase MV", "code": 180 }, { "name": "Three Phase MV", "code": 181 }, { "name": "Two Phase MV", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 10, "name": "Medium Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service", "description": "Medium Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Service MV", "code": 170 }, { "name": "Overhead Three Phase Service MV", "code": 171 }, { "name": "Overhead Two Phase Service MV", "code": 172 }, { "name": "Submersible Single Phase Service MV", "code": 173 }, { "name": "Submersible Three Phase Service MV", "code": 174 }, { "name": "Underground Single Phase Service MV", "code": 175 }, { "name": "Underground Three Phase Service MV", "code": 176 }, { "name": "Underground Two Phase Service MV", "code": 177 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 14, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar", "description": "Low Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Cabinet LV", "code": 80 }, { "name": "AC Station LV", "code": 81 }, { "name": "DC Cabinet LV", "code": 82 }, { "name": "DC Station LV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 5, "name": "Low Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector", "description": "Low Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector LV", "code": 120 }, { "name": "DC Connector LV", "code": 121 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 7, "name": "Low Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service", "description": "List of asset types for Low Voltage Services", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service LV", "code": 110 }, { "name": "AC Underground Service LV", "code": 112 }, { "name": "DC Overhead Service LV", "code": 113 }, { "name": "DC Underground Service LV", "code": 115 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 13, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor", "description": "Low Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead LV", "code": 100 }, { "name": "DC Overhead LV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 6, "name": "Low Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor", "description": "Low VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground LV", "code": 102 }, { "name": "DC Underground LV", "code": 105 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 37, "name": "Low Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor", "description": "Low VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible LV", "code": 101 }, { "name": "DC Submersible LV", "code": 104 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 38, "name": "Low Voltage Submersible Conductor" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "WithstandRating": {"type": "inherited"}, "conductorsheaththickness": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Neutral", "description": "Neutral", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Bare", "code": 200 }, { "name": "Overhead Shielded", "code": 201 }, { "name": "Underground Shielded", "code": 202 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Neutral_Material", "description": "List of valid neutral materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Steel", "code": 506 }, { "name": "Aluminum", "code": 515 }, { "name": "All Aluminum Conductor", "code": 516 }, { "name": "All Aluminum Steel Reinforced", "code": 517 }, { "name": "Copper", "code": 525 }, { "name": "Hard Drawn Copper", "code": 526 }, { "name": "Soft Drawn Copper", "code": 527 }, { "name": "Stranded Copper", "code": 528 }, { "name": "Copper Weld", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 11, "name": "Neutral Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Ground", "description": "Ground", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Covered Ground", "code": 221 }, { "name": "Bare Ground", "code": 222 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 12, "name": "Ground Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor", "description": "High Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead HV", "code": 20 }, { "name": "DC Overhead HV", "code": 23 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": {"type": "inherited"}, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 2, "name": "High Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor", "description": "High VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground HV", "code": 22 }, { "name": "DC Underground HV", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": null, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 31, "name": "High Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor", "description": "High VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible HV", "code": 21 }, { "name": "DC Submersible HV", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 32, "name": "High Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar", "description": "High Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Station Single Phase HV", "code": 1 }, { "name": "AC Station Three Phase HV", "code": 2 }, { "name": "DC Station HV", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 1, "name": "High Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector", "description": "High Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector HV", "code": 40 }, { "name": "DC Connector HV", "code": 41 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 3, "name": "High Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire", "description": "High Voltage Static Wire", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 60 }, { "name": "Single", "code": 61 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 4, "name": "High Voltage Static Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service", "description": "High Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service HV", "code": 260 }, { "name": "AC Underground Service HV", "code": 261 }, { "name": "DC Overhead Service HV", "code": 262 }, { "name": "DC Underground Service HV", "code": 263 }, { "name": "AC Submersible Service HV", "code": 264 }, { "name": "DC Submersible Service HV", "code": 265 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 15, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor", "description": "Medium Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase MV", "code": 160 }, { "name": "Overhead Three Phase MV", "code": 161 }, { "name": "Overhead Two Phase MV", "code": 162 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 9, "name": "Medium Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor", "description": "Medium VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Underground Single Phase MV", "code": 165 }, { "name": "Underground Three Phase MV", "code": 166 }, { "name": "Underground Two Phase MV", "code": 167 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 34, "name": "Medium Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor", "description": "Medium VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Submersible Single Phase MV", "code": 163 }, { "name": "Submersible Three Phase MV", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 35, "name": "Medium Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar", "description": "Medium Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cabinet Single Phase MV", "code": 140 }, { "name": "Cabinet Three Phase MV", "code": 141 }, { "name": "Station Single Phase MV", "code": 142 }, { "name": "Station Three Phase MV", "code": 143 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 8, "name": "Medium Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector", "description": "Medium Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase MV", "code": 180 }, { "name": "Three Phase MV", "code": 181 }, { "name": "Two Phase MV", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 10, "name": "Medium Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service", "description": "Medium Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Service MV", "code": 170 }, { "name": "Overhead Three Phase Service MV", "code": 171 }, { "name": "Overhead Two Phase Service MV", "code": 172 }, { "name": "Submersible Single Phase Service MV", "code": 173 }, { "name": "Submersible Three Phase Service MV", "code": 174 }, { "name": "Underground Single Phase Service MV", "code": 175 }, { "name": "Underground Three Phase Service MV", "code": 176 }, { "name": "Underground Two Phase Service MV", "code": 177 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 14, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar", "description": "Low Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Cabinet LV", "code": 80 }, { "name": "AC Station LV", "code": 81 }, { "name": "DC Cabinet LV", "code": 82 }, { "name": "DC Station LV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 5, "name": "Low Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector", "description": "Low Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector LV", "code": 120 }, { "name": "DC Connector LV", "code": 121 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 7, "name": "Low Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service", "description": "List of asset types for Low Voltage Services", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service LV", "code": 110 }, { "name": "AC Underground Service LV", "code": 112 }, { "name": "DC Overhead Service LV", "code": 113 }, { "name": "DC Underground Service LV", "code": 115 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 13, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor", "description": "Low Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead LV", "code": 100 }, { "name": "DC Overhead LV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 6, "name": "Low Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor", "description": "Low VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground LV", "code": 102 }, { "name": "DC Underground LV", "code": 105 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 37, "name": "Low Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor", "description": "Low VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible LV", "code": 101 }, { "name": "DC Submersible LV", "code": 104 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 38, "name": "Low Voltage Submersible Conductor" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "effectiveMinScale": 12000, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1757937049000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 440, "name": "Primary Conductor", "type": "Feature Layer", "description": "

The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within any container feature that has rules allowing it.<\/SPAN><\/P><\/DIV><\/DIV><\/DIV>", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 400, "name": "Electric" }, "subLayers": [], "minScale": 24000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "ASSETGROUP", "field2": "ASSETTYPE", "uniqueValueInfos": [ { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "2,20", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "6,100", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,160", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,161", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "9,162", "label": "Overhead" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,165", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,166", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "34,167", "label": "Underground" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 3 }, "value": "37,102", "label": "Underground" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 252, 240, 255 ], "toColor": [ 212, 252, 240, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 179, 252, 255 ], "toColor": [ 252, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 183, 182, 255 ], "toColor": [ 252, 183, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 201, 252, 255 ], "toColor": [ 179, 201, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 238, 182, 255 ], "toColor": [ 252, 238, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 184, 252, 189, 255 ], "toColor": [ 184, 252, 189, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 240, 255 ], "toColor": [ 252, 212, 240, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 234, 215, 255 ], "toColor": [ 252, 234, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 228, 252, 255 ], "toColor": [ 179, 228, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 221, 202, 252, 255 ], "toColor": [ 221, 202, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 237, 252, 210, 255 ], "toColor": [ 237, 252, 210, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 217, 255 ], "toColor": [ 252, 184, 217, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 218, 252, 179, 255 ], "toColor": [ 218, 252, 179, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 646553.9354125783, "ymin": 639229.2276111543, "xmax": 707061.4210246615, "ymax": 695982.9940246567, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "assetgroup", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "WS1_Lifecycle_Status_Combined", "description": "Bitwise combination of lifecycle states for subnetwork management", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Proposed and In Service", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "In Service and Planned Removal", "code": 6 }, { "name": "Maintenance", "code": 7 }, { "name": "Design", "code": 11 }, { "name": "Abandoned", "code": 12 }, { "name": "Removed", "code": 13 }, { "name": "Retired", "code": 14 }, { "name": "NA", "code": 15 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "SHAPE.STLength()", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S183_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "WithstandRating": {"type": "inherited"}, "conductorsheaththickness": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Neutral", "description": "Neutral", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Bare", "code": 200 }, { "name": "Overhead Shielded", "code": 201 }, { "name": "Underground Shielded", "code": 202 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Neutral_Material", "description": "List of valid neutral materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Steel", "code": 506 }, { "name": "Aluminum", "code": 515 }, { "name": "All Aluminum Conductor", "code": 516 }, { "name": "All Aluminum Steel Reinforced", "code": 517 }, { "name": "Copper", "code": 525 }, { "name": "Hard Drawn Copper", "code": 526 }, { "name": "Soft Drawn Copper", "code": 527 }, { "name": "Stranded Copper", "code": 528 }, { "name": "Copper Weld", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 11, "name": "Neutral Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Ground", "description": "Ground", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Covered Ground", "code": 221 }, { "name": "Bare Ground", "code": 222 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 12, "name": "Ground Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor", "description": "High Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead HV", "code": 20 }, { "name": "DC Overhead HV", "code": 23 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": {"type": "inherited"}, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 2, "name": "High Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor", "description": "High VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground HV", "code": 22 }, { "name": "DC Underground HV", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 31, "name": "High Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor", "description": "High VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible HV", "code": 21 }, { "name": "DC Submersible HV", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 32, "name": "High Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar", "description": "High Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Station Single Phase HV", "code": 1 }, { "name": "AC Station Three Phase HV", "code": 2 }, { "name": "DC Station HV", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 1, "name": "High Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector", "description": "High Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector HV", "code": 40 }, { "name": "DC Connector HV", "code": 41 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 3, "name": "High Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire", "description": "High Voltage Static Wire", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 60 }, { "name": "Single", "code": 61 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 4, "name": "High Voltage Static Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service", "description": "High Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service HV", "code": 260 }, { "name": "AC Underground Service HV", "code": 261 }, { "name": "DC Overhead Service HV", "code": 262 }, { "name": "DC Underground Service HV", "code": 263 }, { "name": "AC Submersible Service HV", "code": 264 }, { "name": "DC Submersible Service HV", "code": 265 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 15, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor", "description": "Medium Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase MV", "code": 160 }, { "name": "Overhead Three Phase MV", "code": 161 }, { "name": "Overhead Two Phase MV", "code": 162 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 9, "name": "Medium Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor", "description": "Medium VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Underground Single Phase MV", "code": 165 }, { "name": "Underground Three Phase MV", "code": 166 }, { "name": "Underground Two Phase MV", "code": 167 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 34, "name": "Medium Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor", "description": "Medium VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Submersible Single Phase MV", "code": 163 }, { "name": "Submersible Three Phase MV", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 35, "name": "Medium Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar", "description": "Medium Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cabinet Single Phase MV", "code": 140 }, { "name": "Cabinet Three Phase MV", "code": 141 }, { "name": "Station Single Phase MV", "code": 142 }, { "name": "Station Three Phase MV", "code": 143 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 8, "name": "Medium Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector", "description": "Medium Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase MV", "code": 180 }, { "name": "Three Phase MV", "code": 181 }, { "name": "Two Phase MV", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 10, "name": "Medium Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service", "description": "Medium Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Service MV", "code": 170 }, { "name": "Overhead Three Phase Service MV", "code": 171 }, { "name": "Overhead Two Phase Service MV", "code": 172 }, { "name": "Submersible Single Phase Service MV", "code": 173 }, { "name": "Submersible Three Phase Service MV", "code": 174 }, { "name": "Underground Single Phase Service MV", "code": 175 }, { "name": "Underground Three Phase Service MV", "code": 176 }, { "name": "Underground Two Phase Service MV", "code": 177 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 14, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar", "description": "Low Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Cabinet LV", "code": 80 }, { "name": "AC Station LV", "code": 81 }, { "name": "DC Cabinet LV", "code": 82 }, { "name": "DC Station LV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 5, "name": "Low Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector", "description": "Low Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector LV", "code": 120 }, { "name": "DC Connector LV", "code": 121 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 7, "name": "Low Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service", "description": "List of asset types for Low Voltage Services", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service LV", "code": 110 }, { "name": "AC Underground Service LV", "code": 112 }, { "name": "DC Overhead Service LV", "code": 113 }, { "name": "DC Underground Service LV", "code": 115 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 13, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor", "description": "Low Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead LV", "code": 100 }, { "name": "DC Overhead LV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 6, "name": "Low Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor", "description": "Low VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground LV", "code": 102 }, { "name": "DC Underground LV", "code": 105 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 37, "name": "Low Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor", "description": "Low VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible LV", "code": 101 }, { "name": "DC Submersible LV", "code": 104 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 38, "name": "Low Voltage Submersible Conductor" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "WithstandRating": {"type": "inherited"}, "conductorsheaththickness": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Neutral", "description": "Neutral", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Bare", "code": 200 }, { "name": "Overhead Shielded", "code": 201 }, { "name": "Underground Shielded", "code": 202 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": {"type": "inherited"}, "phasechange": {"type": "inherited"}, "phasesplan": {"type": "inherited"}, "phasesenergized": {"type": "inherited"}, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Neutral_Material", "description": "List of valid neutral materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Steel", "code": 506 }, { "name": "Aluminum", "code": 515 }, { "name": "All Aluminum Conductor", "code": 516 }, { "name": "All Aluminum Steel Reinforced", "code": 517 }, { "name": "Copper", "code": 525 }, { "name": "Hard Drawn Copper", "code": 526 }, { "name": "Soft Drawn Copper", "code": 527 }, { "name": "Stranded Copper", "code": 528 }, { "name": "Copper Weld", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 11, "name": "Neutral Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Ground", "description": "Ground", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Covered Ground", "code": 221 }, { "name": "Bare Ground", "code": 222 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Ground_Material", "description": "Grounding material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Aluminum", "code": 515 }, { "name": "Copper", "code": 525 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 12, "name": "Ground Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor", "description": "High Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead HV", "code": 20 }, { "name": "DC Overhead HV", "code": 23 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": {"type": "inherited"}, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 2, "name": "High Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Underground_Conductor", "description": "High VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground HV", "code": 22 }, { "name": "DC Underground HV", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_ELectric_High_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of High Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "100 kV", "code": 100000 }, { "name": "121 kV", "code": 121000 }, { "name": "124 kV", "code": 124000 }, { "name": "145 kV", "code": 145000 }, { "name": "172 kV", "code": 172000 }, { "name": "245 kV", "code": 245000 }, { "name": "420 kV", "code": 420000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": null, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 31, "name": "High Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor", "description": "High VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible HV", "code": 21 }, { "name": "DC Submersible HV", "code": 24 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 32, "name": "High Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Busbar", "description": "High Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Station Single Phase HV", "code": 1 }, { "name": "AC Station Three Phase HV", "code": 2 }, { "name": "DC Station HV", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 1, "name": "High Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Connector", "description": "High Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector HV", "code": 40 }, { "name": "DC Connector HV", "code": 41 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phases_Constructed", "description": "High Voltage number of Phase Constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 }, { "name": "Six Phase", "code": 6 }, { "name": "Twelve Phase", "code": 12 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 3, "name": "High Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Static_Wire", "description": "High Voltage Static Wire", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 60 }, { "name": "Single", "code": 61 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Phase_Not_Applicable", "description": "Domain for Phase attributes on Neutral and Ground", "codedValues": [ { "name": "N/A", "code": 0 }, { "name": "N/A, Traceable", "code": 8 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 4, "name": "High Voltage Static Wire" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_High_Voltage_Service", "description": "High Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service HV", "code": 260 }, { "name": "AC Underground Service HV", "code": 261 }, { "name": "DC Overhead Service HV", "code": 262 }, { "name": "DC Underground Service HV", "code": 263 }, { "name": "AC Submersible Service HV", "code": 264 }, { "name": "DC Submersible Service HV", "code": 265 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the transmission system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "III", "code": 1 }, { "name": "II", "code": 2 }, { "name": "II,III", "code": 3 }, { "name": "I", "code": 4 }, { "name": "I,III", "code": 5 }, { "name": "I,II", "code": 6 }, { "name": "I,II,III", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 kV", "code": 120000 }, { "name": "145 kV", "code": 145000 }, { "name": "170 kV", "code": 170000 }, { "name": "240 kV", "code": 240000 }, { "name": "300 kV", "code": 300000 }, { "name": "362 kV", "code": 362000 }, { "name": "420 kV", "code": 420000 }, { "name": "550 kV", "code": 550000 }, { "name": "800 kV", "code": 800000 }, { "name": "1100 kV", "code": 1100000 }, { "name": "1200 kV", "code": 1200000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for high voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "115 kV", "code": 115000 }, { "name": "138 kV", "code": 138000 }, { "name": "161 kV", "code": 161000 }, { "name": "230 kV", "code": 230000 }, { "name": "345 kV", "code": 345000 }, { "name": "500 kV", "code": 500000 }, { "name": "765 kV", "code": 765000 }, { "name": "18 kV", "code": 18000 }, { "name": "50 kV", "code": 50000 }, { "name": "60 kV", "code": 60000 }, { "name": "70 kV", "code": 70000 }, { "name": "75 kV", "code": 75000 }, { "name": "80 kV", "code": 80000 }, { "name": "100 kV", "code": 100000 }, { "name": "150 kV", "code": 150000 }, { "name": "180 kV", "code": 180000 }, { "name": "200 kV", "code": 200000 }, { "name": "250 kV", "code": 250000 }, { "name": "266 kV", "code": 266000 }, { "name": "277 kV", "code": 277000 }, { "name": "285 kV", "code": 285000 }, { "name": "320 kV", "code": 320000 }, { "name": "350 kV", "code": 350000 }, { "name": "400 kV", "code": 400000 }, { "name": "440 kV", "code": 440000 }, { "name": "515 kV", "code": 515000 }, { "name": "525 kV", "code": 525000 }, { "name": "533 kV", "code": 533000 }, { "name": "600 kV", "code": 600000 }, { "name": "1 MV", "code": 1000000 }, { "name": "1.1 MV", "code": 1100000 }, { "name": "1.2 MV", "code": 1200000 }, { "name": "1.4 MV", "code": 1400000 }, { "name": "1.5 MV", "code": 1500000 }, { "name": "1.8 MV", "code": 1800000 }, { "name": "2.5 MV", "code": 2500000 }, { "name": "3 MV", "code": 3000000 }, { "name": "4 MV", "code": 4000000 }, { "name": "5 MV", "code": 5000000 }, { "name": "6 MV", "code": 6000000 }, { "name": "6.4 MV", "code": 6400000 }, { "name": "7.2 MV", "code": 7200000 }, { "name": "8 MV", "code": 8000000 }, { "name": "10 MV", "code": 10000000 }, { "name": "12 MV", "code": 12000000 }, { "name": "46 kV", "code": 46000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_High_Voltage_Conductor_Material", "description": "List of valid High Voltage Conductor Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 }, { "name": "1272 ACSR Bittern", "code": 507 }, { "name": "336 ACSR Merlin", "code": 514 }, { "name": "795 AAC Arbutus", "code": 526 }, { "name": "795 ACSR Drake", "code": 527 }, { "name": "927 ACAR", "code": 529 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 15, "name": "High Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor", "description": "Medium Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase MV", "code": 160 }, { "name": "Overhead Three Phase MV", "code": 161 }, { "name": "Overhead Two Phase MV", "code": 162 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 9, "name": "Medium Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor", "description": "Medium VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Underground Single Phase MV", "code": 165 }, { "name": "Underground Three Phase MV", "code": 166 }, { "name": "Underground Two Phase MV", "code": 167 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "conductorspacing": {"type": "inherited"}, "phaseorder": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 34, "name": "Medium Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor", "description": "Medium VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Submersible Single Phase MV", "code": 163 }, { "name": "Submersible Three Phase MV", "code": 164 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Conductor_Material", "description": "List of valid medium voltage conductor materials for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "#1 ACSR", "code": 1 }, { "name": "#1 AL", "code": 2 }, { "name": "#1 B.STRD", "code": 3 }, { "name": "#1 CU", "code": 4 }, { "name": "#1 WP", "code": 5 }, { "name": "#2 PID AL", "code": 6 }, { "name": "#2 3/4 AWAC", "code": 7 }, { "name": "#2 4/3 AWAC", "code": 8 }, { "name": "#2 5/2 AWAC", "code": 9 }, { "name": "#2 5005", "code": 10 }, { "name": "#2 AAAC", "code": 11 }, { "name": "#2 AAC", "code": 12 }, { "name": "#2 AACTW", "code": 13 }, { "name": "#2 ACAR", "code": 14 }, { "name": "#2 ACSR", "code": 15 }, { "name": "#2 ACSR/SD", "code": 17 }, { "name": "#2 ACSRTW", "code": 18 }, { "name": "#2 AER.CAB", "code": 19 }, { "name": "#2 AL", "code": 20 }, { "name": "#2 AWA", "code": 21 }, { "name": "#2 AWAC", "code": 22 }, { "name": "#2 B.SOL", "code": 23 }, { "name": "#2 B.STRD", "code": 24 }, { "name": "#2 CU", "code": 25 }, { "name": "#2 CU PILC", "code": 26 }, { "name": "#2 HD", "code": 27 }, { "name": "#2 PECN", "code": 28 }, { "name": "#2 PECN AL", "code": 29 }, { "name": "#2 PECN CU", "code": 30 }, { "name": "#2 PECN-PEJ AL", "code": 31 }, { "name": "#2 PECN-PEJ PID", "code": 32 }, { "name": "#2 PECN-PEJ PID AL", "code": 33 }, { "name": "#2 PECN-PID AL", "code": 34 }, { "name": "#2 PID CU", "code": 36 }, { "name": "#2 PID-PEJ AL", "code": 37 }, { "name": "#2 PILC", "code": 38 }, { "name": "#2 PILC NJ CU", "code": 39 }, { "name": "#2 PILC-NJ", "code": 40 }, { "name": "#2 PILC-PEJ", "code": 41 }, { "name": "#2 PILC-PEJ CU", "code": 42 }, { "name": "#2 SOL", "code": 43 }, { "name": "#2 SOL PECN-PEJ AL", "code": 44 }, { "name": "#2 SOL TRXLPECN-PEJ AL PID", "code": 45 }, { "name": "#2 SOL XLPECN-PEJ", "code": 46 }, { "name": "#2 THW", "code": 47 }, { "name": "#2 TREE", "code": 48 }, { "name": "#2 TRXLPECN-PEJ AL PID", "code": 49 }, { "name": "#2 WP", "code": 50 }, { "name": "#2 WPAL", "code": 51 }, { "name": "#2 WPCU", "code": 52 }, { "name": "#2 XLPECN AL", "code": 53 }, { "name": "#2 XLPECN-PEJ", "code": 54 }, { "name": "#2 XLPECN-PEJ AL", "code": 55 }, { "name": "#2 XLPE-PEJ AL", "code": 56 }, { "name": "#2/7 TREE", "code": 57 }, { "name": "#2SOL TRXLPECN-PEJ AL PID", "code": 58 }, { "name": "#4 5005", "code": 59 }, { "name": "#4 ACSR", "code": 60 }, { "name": "#4 ACSRTW", "code": 61 }, { "name": "#4 AL", "code": 62 }, { "name": "#4 B.SOL", "code": 63 }, { "name": "#4 B.STRD", "code": 64 }, { "name": "#4 CU", "code": 65 }, { "name": "#4 GAL", "code": 66 }, { "name": "#4 HD", "code": 67 }, { "name": "#4 LEAD", "code": 68 }, { "name": "#4 NEOPRENE", "code": 69 }, { "name": "#4 PAA", "code": 70 }, { "name": "#4 PECN", "code": 71 }, { "name": "#4 PECN CU", "code": 72 }, { "name": "#4 PELPE CU", "code": 73 }, { "name": "#4 PID CU", "code": 74 }, { "name": "#4 PILC", "code": 75 }, { "name": "#4 PILC-NJ", "code": 76 }, { "name": "#4 PILC-PEJ CU", "code": 77 }, { "name": "#4 THW", "code": 78 }, { "name": "#4 TREE", "code": 79 }, { "name": "#4 WP", "code": 80 }, { "name": "#4 WPAL", "code": 81 }, { "name": "#4 WPCU", "code": 82 }, { "name": "#4A CUWELD", "code": 83 }, { "name": "#4D CUWELD", "code": 84 }, { "name": "#4N CUWELD", "code": 85 }, { "name": "#6 AL", "code": 86 }, { "name": "#6 B.SOL", "code": 87 }, { "name": "#6 B.STRD", "code": 88 }, { "name": "#6 CU", "code": 89 }, { "name": "#6 CUWELD", "code": 90 }, { "name": "#6 CW", "code": 91 }, { "name": "#6 GAL", "code": 92 }, { "name": "#6 HD", "code": 93 }, { "name": "#6 LEAD", "code": 94 }, { "name": "#6 PILC", "code": 95 }, { "name": "#6 PILC-PEJ CU", "code": 96 }, { "name": "#6 SOLID", "code": 97 }, { "name": "#6 THW", "code": 98 }, { "name": "#6 TREE", "code": 99 }, { "name": "#6 WP", "code": 100 }, { "name": "#6 WPAL", "code": 101 }, { "name": "#6 WPCU", "code": 102 }, { "name": "#6A CUWELD", "code": 103 }, { "name": "#8 AL", "code": 104 }, { "name": "#8 B.STRD", "code": 105 }, { "name": "#8 CU", "code": 106 }, { "name": "#8 CUWELD", "code": 107 }, { "name": "#8 HD", "code": 108 }, { "name": "#8 SOL", "code": 109 }, { "name": "#8 WP", "code": 110 }, { "name": "#8 WPCU", "code": 111 }, { "name": "#8A CUWELD", "code": 112 }, { "name": "1 ACSR", "code": 113 }, { "name": "1 ACSRTW", "code": 114 }, { "name": "1/0 15kV SpacerCable", "code": 115 }, { "name": "1/0 4/3 AWAC", "code": 116 }, { "name": "1/0 5005", "code": 117 }, { "name": "1/0 AAAC", "code": 118 }, { "name": "1/0 AAC", "code": 119 }, { "name": "1/0 ACAR", "code": 120 }, { "name": "1/0 ACSR", "code": 121 }, { "name": "1/0 ACSRTW", "code": 122 }, { "name": "1/0 AER.CAB", "code": 123 }, { "name": "1/0 AL", "code": 124 }, { "name": "1/0 ALUMOWELD", "code": 125 }, { "name": "1/0 AWA", "code": 126 }, { "name": "1/0 B.STRD", "code": 127 }, { "name": "1/0 CU", "code": 128 }, { "name": "1/0 LEAD", "code": 129 }, { "name": "1/0 OTH", "code": 130 }, { "name": "1/0 PAA", "code": 131 }, { "name": "1/0 PILC", "code": 132 }, { "name": "1/0 PILC-NJ", "code": 133 }, { "name": "1/0 STEEL", "code": 134 }, { "name": "1/0 THW", "code": 135 }, { "name": "1/0 TREE", "code": 136 }, { "name": "1/0 WP", "code": 137 }, { "name": "1/0 WPAL", "code": 138 }, { "name": "1/0 WPCU", "code": 139 }, { "name": "1000 PECN AL", "code": 140 }, { "name": "1000 PECN-PEJ AL", "code": 141 }, { "name": "1000 PILC-PEJ CU", "code": 142 }, { "name": "1000 TRXLPECN-PEJ CU", "code": 143 }, { "name": "1000 XLPE AL", "code": 144 }, { "name": "1000 XLPECN AL", "code": 145 }, { "name": "1000 XLPECN-PEJ", "code": 146 }, { "name": "1000 XLPECN-PEJ AL", "code": 147 }, { "name": "1000 XLPE-PEJ AL", "code": 148 }, { "name": "1033 ACSR", "code": 149 }, { "name": "1033 AL", "code": 150 }, { "name": "1250 RUBBER", "code": 151 }, { "name": "2/0 AAAC", "code": 152 }, { "name": "2/0 ACSR", "code": 153 }, { "name": "2/0 ACSRTW", "code": 154 }, { "name": "2/0 AL", "code": 155 }, { "name": "2/0 B.STRD", "code": 156 }, { "name": "2/0 CU", "code": 157 }, { "name": "2/0 PECN AL", "code": 158 }, { "name": "2/0 PECN-PEJ AL", "code": 159 }, { "name": "2/0 PILC", "code": 160 }, { "name": "2/0 WP", "code": 161 }, { "name": "2/0 WPAL", "code": 162 }, { "name": "2/0 WPCU", "code": 163 }, { "name": "2/0 XLPE AL", "code": 164 }, { "name": "2/0 XLPECN-PEJ", "code": 165 }, { "name": "2/0 XLPECN-PEJ AL", "code": 166 }, { "name": "2/0 XLPE-PEJ AL", "code": 167 }, { "name": "250 AAC", "code": 168 }, { "name": "250 AL", "code": 169 }, { "name": "250 B.STRD", "code": 170 }, { "name": "250 CU", "code": 171 }, { "name": "3 ACSR", "code": 172 }, { "name": "3 AL", "code": 173 }, { "name": "3 CU", "code": 174 }, { "name": "3 WPCU", "code": 175 }, { "name": "3/0 5/2 AWAC", "code": 176 }, { "name": "3/0 5005", "code": 177 }, { "name": "3/0 ACSR", "code": 178 }, { "name": "3/0 AL", "code": 179 }, { "name": "3/0 B.STRD", "code": 180 }, { "name": "3/0 CU", "code": 181 }, { "name": "3/0 WP", "code": 182 }, { "name": "336 AAC", "code": 183 }, { "name": "336 AACTW", "code": 184 }, { "name": "336 ACAR", "code": 185 }, { "name": "336 ACSR", "code": 186 }, { "name": "336 ACSRTW", "code": 187 }, { "name": "336 AL", "code": 188 }, { "name": "336 CU", "code": 189 }, { "name": "336 WPAL", "code": 190 }, { "name": "336.4 ACSR", "code": 191 }, { "name": "336.4 PAA", "code": 192 }, { "name": "350 EPR-PEJ CU", "code": 193 }, { "name": "350 PECN AL", "code": 194 }, { "name": "350 PECN-PEJ AL", "code": 195 }, { "name": "350 XLPE AL", "code": 196 }, { "name": "350 XLPECN-PEJ", "code": 197 }, { "name": "350 XLPECN-PEJ AL", "code": 198 }, { "name": "355 ACAR", "code": 199 }, { "name": "394.5 5005", "code": 200 }, { "name": "394.5 BNDL 5005", "code": 201 }, { "name": "395 AAAC", "code": 202 }, { "name": "395 ACAR", "code": 203 }, { "name": "395 ACSR", "code": 204 }, { "name": "395 AL", "code": 205 }, { "name": "397 AAAC", "code": 206 }, { "name": "397 AAC", "code": 207 }, { "name": "397 ACAR", "code": 208 }, { "name": "397 ACSR", "code": 209 }, { "name": "397 ACSRTW", "code": 210 }, { "name": "397 AL", "code": 211 }, { "name": "397 AWA", "code": 212 }, { "name": "397 CU", "code": 213 }, { "name": "4/0 AAAC", "code": 214 }, { "name": "4/0 AAC", "code": 215 }, { "name": "4/0 ACSR", "code": 216 }, { "name": "4/0 ACSR2", "code": 217 }, { "name": "4/0 ACSRTW", "code": 218 }, { "name": "4/0 AER.CAB", "code": 219 }, { "name": "4/0 AL", "code": 220 }, { "name": "4/0 B.STRD", "code": 221 }, { "name": "4/0 BNDL B.STRD", "code": 222 }, { "name": "4/0 CU", "code": 223 }, { "name": "4/0 PECN CU", "code": 224 }, { "name": "4/0 PILC", "code": 225 }, { "name": "4/0 PILC-PEJ CU", "code": 226 }, { "name": "4/0 THW", "code": 227 }, { "name": "4/0 TREE", "code": 228 }, { "name": "4/0 WP", "code": 229 }, { "name": "4/0 WPAL", "code": 230 }, { "name": "4/0 WPCU", "code": 231 }, { "name": "400K B.STRD", "code": 232 }, { "name": "500 AL", "code": 233 }, { "name": "500 CU", "code": 234 }, { "name": "500 EPR-PEJ CU", "code": 235 }, { "name": "500 PECN", "code": 236 }, { "name": "500 PECN CU", "code": 237 }, { "name": "500 PECN-PEJ CU", "code": 238 }, { "name": "500 PILC", "code": 239 }, { "name": "500 PILC-NJ", "code": 240 }, { "name": "500 PILC-PEJ", "code": 241 }, { "name": "500 PILC-PEJ CU", "code": 242 }, { "name": "500 THW", "code": 243 }, { "name": "500 XLPECN-PEJ", "code": 244 }, { "name": "500K B.STRD", "code": 245 }, { "name": "636 AAC", "code": 246 }, { "name": "636 ACAR", "code": 247 }, { "name": "636 ACSR", "code": 248 }, { "name": "636 ACSRTW", "code": 249 }, { "name": "636 AL", "code": 250 }, { "name": "636 B.STRD", "code": 251 }, { "name": "636 CU", "code": 252 }, { "name": "750 AAAC", "code": 253 }, { "name": "750 AAC", "code": 254 }, { "name": "750 ACSR", "code": 255 }, { "name": "750 AL", "code": 256 }, { "name": "750 AWA", "code": 257 }, { "name": "750 B.STRD", "code": 258 }, { "name": "750 CU", "code": 259 }, { "name": "750 EPR-PEJ", "code": 260 }, { "name": "750 EPR-PEJ CU", "code": 261 }, { "name": "750 PECN-PEJ AL", "code": 262 }, { "name": "750 XLPE AL", "code": 263 }, { "name": "750 XLPECN-PEJ", "code": 264 }, { "name": "750 XLPECN-PEJ AL", "code": 265 }, { "name": "750 XLPE-PEJ AL", "code": 266 }, { "name": "795 AAAC", "code": 267 }, { "name": "795 AAC", "code": 268 }, { "name": "795 ACSR", "code": 269 }, { "name": "795 AL", "code": 270 }, { "name": "1100 AL", "code": 271 }, { "name": "927 ACSR", "code": 272 }, { "name": "1272 ACSR Bittern", "code": 273 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 35, "name": "Medium Voltage Submersible Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Busbar", "description": "Medium Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Cabinet Single Phase MV", "code": 140 }, { "name": "Cabinet Three Phase MV", "code": 141 }, { "name": "Station Single Phase MV", "code": 142 }, { "name": "Station Three Phase MV", "code": 143 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 8, "name": "Medium Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Connector", "description": "Medium Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase MV", "code": 180 }, { "name": "Three Phase MV", "code": 181 }, { "name": "Two Phase MV", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 10, "name": "Medium Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Medium_Voltage_Service", "description": "Medium Voltage Service Lines", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Single Phase Service MV", "code": 170 }, { "name": "Overhead Three Phase Service MV", "code": 171 }, { "name": "Overhead Two Phase Service MV", "code": 172 }, { "name": "Submersible Single Phase Service MV", "code": 173 }, { "name": "Submersible Three Phase Service MV", "code": 174 }, { "name": "Underground Single Phase Service MV", "code": 175 }, { "name": "Underground Three Phase Service MV", "code": 176 }, { "name": "Underground Two Phase Service MV", "code": 177 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Phase_Attribution", "description": "List of valid phase identifiers for the distribution system", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "C", "code": 1 }, { "name": "B", "code": 2 }, { "name": "BC", "code": 3 }, { "name": "A", "code": 4 }, { "name": "AC", "code": 5 }, { "name": "AB", "code": 6 }, { "name": "ABC", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Maximum_Voltage", "description": "The maximum voltage, in kV", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "8 kV", "code": 8000 }, { "name": "15 kV", "code": 15000 }, { "name": "25 kV", "code": 25000 }, { "name": "35 kV", "code": 35000 }, { "name": "52 kV", "code": 52000 }, { "name": "72.5 kV", "code": 72500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Medium Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1.2 kV", "code": 1200 }, { "name": "7.2 kV", "code": 7200 }, { "name": "12 kV", "code": 12000 }, { "name": "24 kV", "code": 24000 }, { "name": "28 kV", "code": 28000 }, { "name": "36 kV", "code": 36000 }, { "name": "44 kV", "code": 44000 }, { "name": "64 kV", "code": 64000 }, { "name": "72.5 kV", "code": 72500 }, { "name": "96 kV", "code": 96000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Medium_Voltage_Nominal_Voltage", "description": "List of valid nominal voltages for the distribution system", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.16 kV", "code": 4160 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.9 kV", "code": 6900 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "8.32 kV", "code": 8320 }, { "name": "12 kV", "code": 12000 }, { "name": "12.47 kV", "code": 12470 }, { "name": "13.2 kV", "code": 13200 }, { "name": "13.8 kV", "code": 13800 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 }, { "name": "20.78 kV", "code": 20780 }, { "name": "22.86 kV", "code": 22860 }, { "name": "23 kV", "code": 23000 }, { "name": "24.94 kV", "code": 24940 }, { "name": "34.5 kV", "code": 34500 }, { "name": "46 kV", "code": 46000 }, { "name": "69 kV", "code": 69000 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Medium_Nominal_Voltage_LG", "description": "Medium Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "2.4 kV", "code": 2400 }, { "name": "4.8 kV", "code": 4800 }, { "name": "6.93 kV", "code": 6930 }, { "name": "7.2 kV", "code": 7200 }, { "name": "7.62 kV", "code": 7620 }, { "name": "7.97 kV", "code": 7970 }, { "name": "12 kV", "code": 12000 }, { "name": "13.2 kV", "code": 13200 }, { "name": "14.4 kV", "code": 14400 }, { "name": "19.92 kV", "code": 19920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 14, "name": "Medium Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Busbar", "description": "Low Voltage Busbar", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Cabinet LV", "code": 80 }, { "name": "AC Station LV", "code": 81 }, { "name": "DC Cabinet LV", "code": 82 }, { "name": "DC Station LV", "code": 83 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": { "type": "codedValue", "name": "WS1_Electric_Busbar_Material", "description": "List of valid Busbar Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Solid Aluminium", "code": 401 }, { "name": "Solid Copper", "code": 402 }, { "name": "Solid Steel", "code": 403 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 5, "name": "Low Voltage Busbar" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Connector", "description": "Low Voltage Connector", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Connector LV", "code": 120 }, { "name": "DC Connector LV", "code": 121 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Connector_Material", "description": "List of valid Connector Common Conductor Material", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "ACSS/AW", "code": 1004 }, { "name": "ACSS/TW", "code": 1005 }, { "name": "AAC", "code": 1006 }, { "name": "AAC/TW", "code": 1007 }, { "name": "AAAC", "code": 1008 }, { "name": "ACAR", "code": 1009 }, { "name": "Welded Aluminum Sheath", "code": 1010 }, { "name": "Copper Wires with Aluminum Sheath", "code": 1011 }, { "name": "Copper Wires with Copper Sheath", "code": 1012 }, { "name": "Copper Wires with Lead Sheath", "code": 1013 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 7, "name": "Low Voltage Connector" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Service", "description": "List of asset types for Low Voltage Services", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead Service LV", "code": 110 }, { "name": "AC Underground Service LV", "code": 112 }, { "name": "DC Overhead Service LV", "code": 113 }, { "name": "DC Underground Service LV", "code": 115 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 13, "name": "Low Voltage Service" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor", "description": "Low Voltage Conductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Overhead LV", "code": 100 }, { "name": "DC Overhead LV", "code": 103 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": {"type": "inherited"}, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "normaloperatingstatus": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 6, "name": "Low Voltage Overhead Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor", "description": "Low VoltageUndergroundConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Underground LV", "code": 102 }, { "name": "DC Underground LV", "code": 105 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 37, "name": "Low Voltage Underground Conductor" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor", "description": "Low VoltageSubmersibleConductor", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "AC Submersible LV", "code": 101 }, { "name": "DC Submersible LV", "code": 104 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "ISCONNECTED": {"type": "inherited"}, "FROMDEVICETERMINAL": {"type": "inherited"}, "TODEVICETERMINAL": {"type": "inherited"}, "phasesnormal": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasechange": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesplan": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasesenergized": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Phase_Attribution", "description": "Low Voltage Phase labels", "codedValues": [ { "name": "De-Energized", "code": 0 }, { "name": "c", "code": 1 }, { "name": "b", "code": 2 }, { "name": "bc", "code": 3 }, { "name": "a", "code": 4 }, { "name": "ac", "code": 5 }, { "name": "ab", "code": 6 }, { "name": "abc", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "phasefrequency": {"type": "inherited"}, "numphasesconstructed": { "type": "codedValue", "name": "WS1_Electric_Medium_Low_Voltage_Number_Of_Phases", "description": "Low Voltage number of phases constructed", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Phase", "code": 1 }, { "name": "Two Phase", "code": 2 }, { "name": "Three Phase", "code": 3 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Maximum_Voltage", "description": "Low Voltage maximum voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "229 V", "code": 229 }, { "name": "253 V", "code": 253 }, { "name": "264 V", "code": 264 }, { "name": "440 V", "code": 440 }, { "name": "528 V", "code": 528 }, { "name": "660 V", "code": 660 }, { "name": "759 V", "code": 759 }, { "name": "1.1 kV", "code": 1100 }, { "name": "480 V", "code": 480 }, { "name": "240 V", "code": 240 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maxoperatingvoltage": { "type": "codedValue", "name": "WS1_ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL", "description": "List of Low Voltage maximum voltages", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "600 V", "code": 600 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltage": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Nominal_Voltage", "description": "Low Voltage Line to Line Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "208 V", "code": 208 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 }, { "name": "600 V", "code": 600 }, { "name": "400 V", "code": 400 }, { "name": "216 V", "code": 216 }, { "name": "12 V", "code": 12 }, { "name": "24 V", "code": 24 }, { "name": "48 V", "code": 48 }, { "name": "96 V", "code": 96 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "nominalvoltagelg": { "type": "codedValue", "name": "WS1_Electric_Low_Nominal_Voltage_LG", "description": "Low Voltage Line to Ground Nominal Operating Voltage", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "120 V", "code": 120 }, { "name": "125 V", "code": 125 }, { "name": "277 V", "code": 277 }, { "name": "240 V", "code": 240 }, { "name": "480 V", "code": 480 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "grounding": {"type": "inherited"}, "commonconductortype": { "type": "codedValue", "name": "WS1_Electric_Low_Voltage_Conductor_Material", "description": "Low Voltage conductor type", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Other", "code": 999 }, { "name": "ACSR", "code": 1001 }, { "name": "ACSR/AW", "code": 1002 }, { "name": "ACSR/TW", "code": 1003 }, { "name": "AAC", "code": 1006 }, { "name": "ACAR", "code": 1009 }, { "name": "Duplex", "code": 2001 }, { "name": "Triplex", "code": 2002 }, { "name": "Quadraplex", "code": 2003 }, { "name": "6 Duplex Shepherd", "code": 2004 }, { "name": "6 Triplex Voluta", "code": 2005 }, { "name": "4 Triplex Periwinkle", "code": 2006 }, { "name": "4 Quad Hackney", "code": 2007 }, { "name": "2 Triplex Cockle", "code": 2008 }, { "name": "2 Quad Palimino", "code": 2009 }, { "name": "1/0 Tri Janithina", "code": 2010 }, { "name": "1/0 Quad Constena", "code": 2011 }, { "name": "4/0 Triplex Cerapus", "code": 2012 }, { "name": "4/0 Quad Appoloosa", "code": 2013 }, { "name": "10 THHN", "code": 2014 }, { "name": "8 THHN", "code": 2015 }, { "name": "6 THHN", "code": 2016 }, { "name": "6 Duplex Claflin", "code": 2017 }, { "name": "4 Duplex Delgado", "code": 2018 }, { "name": "4 Triplex Vasser", "code": 2019 }, { "name": "2 Copper", "code": 2020 }, { "name": "1/0 Triplex Brenau", "code": 2021 }, { "name": "2/0 Triplex", "code": 2022 }, { "name": "4/0 Copper", "code": 2023 }, { "name": "4/0 Tri Sweebriar", "code": 2024 }, { "name": "250 AL", "code": 2025 }, { "name": "350 Triplex Wesleyan", "code": 2026 }, { "name": "500 Copper", "code": 2027 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "neutraltype": {"type": "inherited"}, "sharedneutral": {"type": "inherited"}, "lifecyclestatus": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "primaryphaseshift": {"type": "inherited"}, "isvalidloop": {"type": "inherited"}, "conductormaterial": {"type": "inherited"}, "conductorinsulationmaterial": {"type": "inherited"}, "conductorsize": {"type": "inherited"}, "kcmil": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "ISCONNECTED": 2, "FROMDEVICETERMINAL": 0, "TODEVICETERMINAL": 0, "GLOBALID": null, "SUBNETWORKNAME": "Unknown", "SUPPORTEDSUBNETWORKNAME": "Unknown", "SUPPORTINGSUBNETWORKNAME": "Unknown", "assetid": null, "phasesnormal": 0, "phasechange": null, "phasesplan": 0, "phasesenergized": 0, "phasefrequency": null, "numphasesconstructed": null, "maxvoltage": null, "maxoperatingvoltage": null, "nominalvoltage": null, "nominalvoltagelg": null, "grounding": null, "commonconductortype": null, "neutraltype": null, "sharedneutral": null, "tiername": null, "lifecyclestatus": 2, "inservicedate": null, "retireddate": null, "measuredlength": null, "spatialsource": null, "spatialconfidence": null, "ownedby": 3, "maintby": 1, "labeltext": null, "notes": null, "installdate": null, "ohm": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "normaloperatingstatus": null, "conductorsperphase": null, "constructionstatus": 6, "primaryphaseshift": null, "sectionid": null, "isvalidloop": null, "WithstandRating": null, "conductormaterial": null, "conductorinsulationmaterial": null, "conductorsize": null, "kcmil": null, "conductorfulldiameter": null, "conductorinsulationthickness": null, "conductorinsulationthich_m": null, "conductorsheaththickness": null, "conductorsheaththickness_metr": null, "injectionid": null, "injectiondate": null, "conductorspacing": null, "phaseorder": null, "workorder": null, "VALIDATIONSTATUS": 6, "lpfield": null }, "code": 38, "name": "Low Voltage Submersible Conductor" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "effectiveMinScale": 12000, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1757937049000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 450, "name": "Electric/Fiber Conduit", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 }, "copyrightText": "", "parentLayer": { "id": 400, "name": "Electric" }, "subLayers": [], "minScale": 10000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 0, 0, 255 ], "width": 0.2 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674290.8904372454, "ymin": 643558.6110127419, "xmax": 707051.7212409116, "ymax": 687801.6045475751, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "ASSETGROUP", "typeIdField": "ASSETGROUP", "subtypeFieldName": "ASSETGROUP", "subtypeField": "ASSETGROUP", "defaultSubtypeCode": 0, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "ASSETGROUP", "type": "esriFieldTypeInteger", "alias": "Asset Group", "domain": null }, { "name": "ASSETTYPE", "type": "esriFieldTypeSmallInteger", "alias": "Asset Type", "domain": null }, { "name": "lifecyclestatus", "type": "esriFieldTypeSmallInteger", "alias": "Lifecycle Status", "domain": { "type": "codedValue", "name": "WS1_Lifecycle_Status", "description": "Valid lifecycle states for the assets.", "codedValues": [ { "name": "Out of Service", "code": 0 }, { "name": "Proposed", "code": 1 }, { "name": "In Service", "code": 2 }, { "name": "Design", "code": 3 }, { "name": "Planned Removal", "code": 4 }, { "name": "Abandoned", "code": 5 }, { "name": "Removed", "code": 6 }, { "name": "Retired", "code": 7 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "SHAPE.STLength()", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S180_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Ground", "description": "Asset Types for Ground Cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bare Ground", "code": 801 }, { "name": "Covered Ground", "code": 802 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 801, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Duct_Bank", "description": "Lines used to represent duct banks in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Duct Bank", "code": 81 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "range", "name": "WS1_Wire_Duct_Bank_Width", "description": "Width of the duct bank", "range": [ 0, 50 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Bank_Material", "description": "List of materials for duct banks", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumcapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "usedcapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "availablecapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 102, "name": "Wire Duct Bank" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Aerial_Support", "description": "Lines used to represent aerial supports in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridge Suspension", "code": 121 }, { "name": "Other Suspension", "code": 122 }, { "name": "Spanguy", "code": 123 }, { "name": "Aerial Span", "code": 125 }, { "name": "Communications Support Guy", "code": 126 }, { "name": "Lashing Guy", "code": 127 }, { "name": "Guy Wire", "code": 128 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "codedValue", "name": "WS1_Wire_Structure_Guy_Diameter_in", "description": "List of diameters of guys in inches", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1/4\"", "code": 6 }, { "name": "5/16\"", "code": 7 }, { "name": "3/8\"", "code": 9 }, { "name": "7/16\"", "code": 11 }, { "name": "1/2\"", "code": 12 }, { "name": "9/16\"", "code": 14 }, { "name": "1\"", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Aerial_Support_Material", "description": "List of materials used for aerial supports", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fiberglass", "code": 4 }, { "name": "Steel", "code": 6 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 103, "name": "Wire Aerial Support" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Trench", "description": "Lines used to represent trenches in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trench", "code": 101 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "range", "name": "WS1_Wire_Trench_Width", "description": "Depth of trench", "range": [ 0, 30 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Trench_Material", "description": "List of valid trench materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Open", "code": 11 }, { "name": "Earth Covered", "code": 12 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 104, "name": "Wire Trench" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Tunnel", "description": "Lines used to represent access tunnels in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Tunnel", "code": 221 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 112, "name": "Access Tunnel" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Conduit", "description": "The Asset Types for the Electric High Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit HV", "code": 114 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 105, "name": "Electric High Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit", "description": "The Asset Types for the Electric Low Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit LV", "code": 118 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 106, "name": "Electric Low Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit", "description": "The Asset Types for the Electric Medium Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit MV", "code": 112 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 107, "name": "Electric Medium Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Connector", "description": "Lines used to represent connecters inside vaults and handholes in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Vault Duct", "code": 181 }, { "name": "Handhole Duct", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 111, "name": "Connector Line" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway", "description": "Pathway for High Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway HV", "code": 231 }, { "name": "Underground Pathway HV", "code": 232 }, { "name": "Submersible Pathway HV", "code": 233 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 113, "name": "Electric High Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway", "description": "Pathway for Medium Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway MV", "code": 241 }, { "name": "Underground Pathway MV", "code": 242 }, { "name": "Submersible Pathway MV", "code": 243 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 114, "name": "Electric Medium Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway", "description": "Pathway for Low Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway LV", "code": 251 }, { "name": "Underground Pathway LV", "code": 252 }, { "name": "Submersible Pathway LV", "code": 253 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 115, "name": "Electric Low Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Microduct_Pathway", "description": "Asset Types for Microduct Casings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Microduct Casing", "code": 85 }, { "name": "Multiple Microduct Casing", "code": 86 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 118, "name": "Wire Microduct Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Casing", "description": "", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Casing", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 101, "name": "Wire Casing" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Linear_Marker", "description": "", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Buried Cable Marker", "code": 462 }, { "name": "Covered Marker", "code": 465 }, { "name": "Terrain Marker", "code": 466 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 124, "name": "Linear Marker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Communications_Conduit", "description": "Lines used to represent conduit in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit", "code": 111 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Communications_Conduit_Type", "description": "The type of conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Abandoned Electric Conduit", "code": 101 }, { "name": "Abandoned Gas Pipe", "code": 102 }, { "name": "Abandoned Water Main", "code": 103 }, { "name": "Sewer pipe", "code": 104 }, { "name": "Storm Pipe", "code": 105 }, { "name": "Abandoned Communication Conduit", "code": 106 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 109, "name": "Communications Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Static_Wire", "description": "Static Wire modeled in the structure network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 860 }, { "name": "Single", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "id": 802, "name": "Static Wire" } ], "subtypes": [ { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_IFPower_2918_UnknownAssetType", "description": "The AssetType domain for the Unknown AssetGroup.", "codedValues": [ { "name": "Unknown", "code": 0 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": null, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 0, "name": "Unknown" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Ground", "description": "Asset Types for Ground Cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bare Ground", "code": 801 }, { "name": "Covered Ground", "code": 802 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 801, "name": "Ground" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Duct_Bank", "description": "Lines used to represent duct banks in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Duct Bank", "code": 81 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "range", "name": "WS1_Wire_Duct_Bank_Width", "description": "Width of the duct bank", "range": [ 0, 50 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Bank_Material", "description": "List of materials for duct banks", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "maximumcapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "usedcapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "availablecapacity": { "type": "range", "name": "WS1_Wire_Number_of_Ducts", "description": "", "range": [ 0, 64 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 102, "name": "Wire Duct Bank" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Aerial_Support", "description": "Lines used to represent aerial supports in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Bridge Suspension", "code": 121 }, { "name": "Other Suspension", "code": 122 }, { "name": "Spanguy", "code": 123 }, { "name": "Aerial Span", "code": 125 }, { "name": "Communications Support Guy", "code": 126 }, { "name": "Lashing Guy", "code": 127 }, { "name": "Guy Wire", "code": 128 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "codedValue", "name": "WS1_Wire_Structure_Guy_Diameter_in", "description": "List of diameters of guys in inches", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "1/4\"", "code": 6 }, { "name": "5/16\"", "code": 7 }, { "name": "3/8\"", "code": 9 }, { "name": "7/16\"", "code": 11 }, { "name": "1/2\"", "code": 12 }, { "name": "9/16\"", "code": 14 }, { "name": "1\"", "code": 25 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Aerial_Support_Material", "description": "List of materials used for aerial supports", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Fiberglass", "code": 4 }, { "name": "Steel", "code": 6 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 103, "name": "Wire Aerial Support" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Trench", "description": "Lines used to represent trenches in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Trench", "code": 101 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": { "type": "range", "name": "WS1_Wire_Trench_Width", "description": "Depth of trench", "range": [ 0, 30 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Trench_Material", "description": "List of valid trench materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Open", "code": 11 }, { "name": "Earth Covered", "code": 12 }, { "name": "Other", "code": 20 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 104, "name": "Wire Trench" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Tunnel", "description": "Lines used to represent access tunnels in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Tunnel", "code": 221 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 112, "name": "Access Tunnel" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Conduit", "description": "The Asset Types for the Electric High Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit HV", "code": 114 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 105, "name": "Electric High Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit", "description": "The Asset Types for the Electric Low Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit LV", "code": 118 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 106, "name": "Electric Low Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit", "description": "The Asset Types for the Electric Medium Voltage Conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit MV", "code": 112 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 107, "name": "Electric Medium Voltage Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Connector", "description": "Lines used to represent connecters inside vaults and handholes in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Vault Duct", "code": 181 }, { "name": "Handhole Duct", "code": 182 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 111, "name": "Connector Line" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway", "description": "Pathway for High Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway HV", "code": 231 }, { "name": "Underground Pathway HV", "code": 232 }, { "name": "Submersible Pathway HV", "code": 233 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 113, "name": "Electric High Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway", "description": "Pathway for Medium Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway MV", "code": 241 }, { "name": "Underground Pathway MV", "code": 242 }, { "name": "Submersible Pathway MV", "code": 243 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 114, "name": "Electric Medium Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway", "description": "Pathway for Low Voltage cables", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Overhead Pathway LV", "code": 251 }, { "name": "Underground Pathway LV", "code": 252 }, { "name": "Submersible Pathway LV", "code": 253 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 115, "name": "Electric Low Voltage Cable Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Microduct_Pathway", "description": "Asset Types for Microduct Casings", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Single Microduct Casing", "code": 85 }, { "name": "Multiple Microduct Casing", "code": 86 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 118, "name": "Wire Microduct Pathway" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Wire_Casing", "description": "", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Casing", "code": 11 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 101, "name": "Wire Casing" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Linear_Marker", "description": "", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Buried Cable Marker", "code": 462 }, { "name": "Covered Marker", "code": 465 }, { "name": "Terrain Marker", "code": 466 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 124, "name": "Linear Marker" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Communications_Conduit", "description": "Lines used to represent conduit in the Structure Network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Conduit", "code": 111 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "diameter": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Wire_Structure_Line_Duct_Material", "description": "List of duct materials", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Composite", "code": 3 }, { "name": "Fiberglass", "code": 4 }, { "name": "Poured Concrete", "code": 8 }, { "name": "Precast Concrete", "code": 9 }, { "name": "Plastic", "code": 10 }, { "name": "Other", "code": 20 }, { "name": "PVC", "code": 15 }, { "name": "RGS", "code": 16 }, { "name": "HDPE", "code": 17 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "designtype": { "type": "codedValue", "name": "WS1_Communications_Conduit_Type", "description": "The type of conduit", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Abandoned Electric Conduit", "code": 101 }, { "name": "Abandoned Gas Pipe", "code": 102 }, { "name": "Abandoned Water Main", "code": 103 }, { "name": "Sewer pipe", "code": 104 }, { "name": "Storm Pipe", "code": 105 }, { "name": "Abandoned Communication Conduit", "code": 106 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "constructionstatus": {"type": "inherited"}, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 109, "name": "Communications Conduit" }, { "domains": { "ASSETTYPE": { "type": "codedValue", "name": "WS1_Asset_Type_Structure_Line_Static_Wire", "description": "Static Wire modeled in the structure network", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "Double", "code": 860 }, { "name": "Single", "code": 861 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "ASSOCIATIONSTATUS": {"type": "inherited"}, "materialcode": { "type": "codedValue", "name": "WS1_Electric_StaticWire_Material", "description": "List of static wire types", "codedValues": [ { "name": "Unknown", "code": 0 }, { "name": "ACSR", "code": 1001 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "lifecyclestatus": {"type": "inherited"}, "spatialsource": {"type": "inherited"}, "spatialconfidence": {"type": "inherited"}, "ownedby": {"type": "inherited"}, "maintby": {"type": "inherited"}, "constructionstatus": {"type": "inherited"}, "ohm": { "type": "range", "name": "WS1_Electric_Ohms_per_KM", "description": "Range domain of valid values for Electric Cable resistance per KM", "range": [ 0, 999999 ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" }, "VALIDATIONSTATUS": {"type": "inherited"} }, "defaultValues": { "ASSETGROUP": null, "ASSETTYPE": 0, "ASSOCIATIONSTATUS": 0, "SUBNETWORKNAME": "Unknown", "GLOBALID": null, "assetid": null, "diameter": null, "materialcode": null, "distance": null, "labeltext": null, "installdate": null, "retireddate": null, "inservicedate": null, "maximumcapacity": null, "usedcapacity": null, "availablecapacity": null, "measuredlength": null, "lifecyclestatus": 2, "spatialsource": null, "spatialconfidence": null, "notes": null, "ownedby": 3, "maintby": 1, "designtype": null, "searchdistance": null, "created_user": null, "created_date": null, "last_edited_user": null, "last_edited_date": null, "constructionstatus": 6, "sectionid": null, "ohm": null, "workorder": null, "VALIDATIONSTATUS": 6 }, "code": 802, "name": "Static Wire" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "hasM": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1757937005000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 600, "name": "Zoning", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 610, "name": "Area of Impact" }, { "id": 620, "name": "Overlay Zone" }, { "id": 630, "name": "Zoning" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 669337.9004999995, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 693960.124499999, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 610, "name": "Area of Impact", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 600, "name": "Zoning" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 54, 74, 97, 0 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 238, 118, 35, 255 ], "width": 2 } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 669337.9004999995, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 693960.124499999, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GlobalID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 100, "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 20, "domain": { "type": "codedValue", "name": "WS3_AOI Type", "description": "Valid area of impact type values", "codedValues": [ { "name": "Active", "code": "Active" }, { "name": "Inactive", "code": "Inactive" }, { "name": "Proposed", "code": "Proposed" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "ActiveDate", "type": "esriFieldTypeDate", "alias": "Active Date", "length": 8, "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": {}, "indexes": [ { "name": "UUID_25", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075261000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 620, "name": "Overlay Zone", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 600, "name": "Zoning" }, "subLayers": [], "minScale": 12000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Type", "uniqueValueInfos": [ { "symbol": { "type": "esriPFS", "url": "6fdb41372a48f71280e3bd63567ea07d", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAwAAAAMCAYAAABWdVznAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAK0lEQVQokWNhIBGwUKLhPwMDAyMhPguSALIkTj4LJU4iCrAgsUf9wIAjXgCgCAk6OP9WWgAAAABJRU5ErkJggg==", "contentType": "image/png", "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 104, 104, 104, 255 ], "width": 0.01 }, "width": 9, "height": 9, "angle": 0, "xoffset": 0, "yoffset": 0, "xscale": 1, "yscale": 1 }, "value": "PT", "label": "Planned Transition (PT)" }, { "symbol": { "type": "esriPFS", "url": "408a797e815861da36172d5e1a1af9a4", "imageData": "iVBORw0KGgoAAAANSUhEUgAAAAwAAAAMCAYAAABWdVznAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAALUlEQVQokWNhIBGwkK/h6P//DNaMjIT4LHABZEk8fBbynUQkYIGzRv3AgDNeADW+HVYZQgPYAAAAAElFTkSuQmCC", "contentType": "image/png", "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 178, 178, 178, 255 ], "width": 0.01 }, "width": 9, "height": 9, "angle": 0, "xoffset": 0, "yoffset": 0, "xscale": 1, "yscale": 1 }, "value": "PT&T-1", "label": "Planned Transition & Tower 1 (PT & T1)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSForwardDiagonal", "color": [ 178, 178, 178, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 104, 104, 104, 255 ], "width": 0.01 } }, "value": "PUD", "label": "Planned Unit Development (PUD)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSHorizontal", "color": [ 0, 112, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 107, 126, 147, 255 ], "width": 0.01 } }, "value": "T-1", "label": "Tower 1 (T-1)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSHorizontal", "color": [ 204, 204, 204, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 156, 156, 156, 255 ], "width": 0.01 } }, "value": "T-2", "label": "Tower 2 (T-2)" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 25, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 676996.25, "ymin": 646282.25, "xmax": 704767.3125, "ymax": 677721.0689999983, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "TYPE", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 10, "domain": { "type": "codedValue", "name": "WS3_PLN Overlay Type", "description": "Valid planning overlay type values", "codedValues": [ { "name": "Planned Transition", "code": "PT" }, { "name": "Planned Transition & Tower 1", "code": "PT&T-1" }, { "name": "Planned Unit Development", "code": "PUD" }, { "name": "Tower 1", "code": "T-1" }, { "name": "Tower 2", "code": "T-2" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I476Type", "fields": "Type", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_220", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S183_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 630, "name": "Zoning", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 600, "name": "Zoning" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Name", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 227, 255, 190, 255 ], "outline": null }, "value": "RE", "label": "Residential Estate (RE)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 204, 255 ], "outline": null }, "value": "RP", "label": "Residential Park (RP)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 0, 255 ], "outline": null }, "value": "R1", "label": "Single Dwelling Residential (R1)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 191, 0, 255 ], "outline": null }, "value": "R2", "label": "Mixed Residential (R2)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 220, 98, 0, 255 ], "outline": null }, "value": "TN", "label": "Traditional Neighborhood (TN)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 204, 255, 0, 255 ], "outline": null }, "value": "RMH", "label": "Residential Mobile Home (RMH)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 76, 0, 255 ], "outline": null }, "value": "R3", "label": "Multiple Dwelling Residential (R3)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 223, 255, 255 ], "outline": null }, "value": "R3A", "label": "Residential Mixed Use (R3A)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 132, 168, 255 ], "outline": null }, "value": "PB", "label": "Professional Business Office (PB)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 230, 0, 165, 255 ], "outline": null }, "value": "CC", "label": "Central Commercial (CC)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 0, 255 ], "outline": null }, "value": "LC", "label": "Limited Commercial (LC)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 178, 235, 255 ], "outline": null }, "value": "HC", "label": "Highway Commercial (HC)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 97, 179, 158, 255 ], "outline": null }, "value": "R&D", "label": "Research and Development (R&D)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 204, 204, 204, 255 ], "outline": null }, "value": "LM", "label": "Light Manufacturing and Heavy Commercial (LM)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 52, 52, 52, 255 ], "outline": null }, "value": "I&M", "label": "Industrial and Manufacturing (I&M)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 153, 102, 204, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.4 } }, "value": "FBC", "label": "Form Based Code (FBC)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 56, 168, 0, 255 ], "outline": null }, "value": "P", "label": "Public (P)" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 188, 252, 179, 255 ], "toColor": [ 188, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 238, 252, 255 ], "toColor": [ 179, 238, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 210, 179, 252, 255 ], "toColor": [ 210, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 244, 199, 255 ], "toColor": [ 252, 244, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 182, 204, 252, 255 ], "toColor": [ 182, 204, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 207, 252, 230, 255 ], "toColor": [ 207, 252, 230, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 232, 255 ], "toColor": [ 252, 184, 232, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 244, 215, 252, 255 ], "toColor": [ 244, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 228, 252, 182, 255 ], "toColor": [ 228, 252, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 229, 252, 255 ], "toColor": [ 212, 229, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 204, 255 ], "toColor": [ 202, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 252, 212, 255 ], "toColor": [ 230, 252, 212, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 216, 207, 255 ], "toColor": [ 252, 216, 207, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 250, 255 ], "toColor": [ 179, 252, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 207, 227, 255 ], "toColor": [ 252, 207, 227, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 50, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673765.1440000013, "ymin": 643478.2014999986, "xmax": 707353.4959999993, "ymax": 689852.7534999996, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 5, "domain": { "type": "codedValue", "name": "WS3_PLN Zoning Name", "description": "Valid planning zoning name values", "codedValues": [ { "name": "Residential Estate", "code": "RE" }, { "name": "Residential Park", "code": "RP" }, { "name": "Single Dwelling Residential", "code": "R1" }, { "name": "Mixed Residential", "code": "R2" }, { "name": "Traditional Neighborhood", "code": "TN" }, { "name": "Residential Mobile Home", "code": "RMH" }, { "name": "Multiple Dwelling Residential", "code": "R3" }, { "name": "Residential Mixed Use", "code": "R3A" }, { "name": "Professional Business Office", "code": "PB" }, { "name": "Central Commercial", "code": "CC" }, { "name": "Limited Commercial", "code": "LC" }, { "name": "Highway Commercial", "code": "HC" }, { "name": "Light Manufacturing and Heavy Commercial", "code": "LM" }, { "name": "Industrial and Manufacturing", "code": "I&M" }, { "name": "Research and Development", "code": "R&D" }, { "name": "Public", "code": "P" }, { "name": "Downtown", "code": "DT" }, { "name": "Form Based Code", "code": "FBC" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I493Name", "fields": "Name", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S200_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 700, "name": "Comprehensive Plan", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 710, "name": "Area of Impact" }, { "id": 720, "name": "Comprehensive Plan" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 662747.3640000001, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 696379.2929999977, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 710, "name": "Area of Impact", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 700, "name": "Comprehensive Plan" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 54, 74, 97, 0 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 238, 118, 35, 255 ], "width": 2 } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 669337.9004999995, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 693960.124499999, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GlobalID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 100, "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 20, "domain": { "type": "codedValue", "name": "WS3_AOI Type", "description": "Valid area of impact type values", "codedValues": [ { "name": "Active", "code": "Active" }, { "name": "Inactive", "code": "Inactive" }, { "name": "Proposed", "code": "Proposed" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "ActiveDate", "type": "esriFieldTypeDate", "alias": "Active Date", "length": 8, "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": {}, "indexes": [ { "name": "UUID_25", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075261000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 720, "name": "Comprehensive Plan", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 700, "name": "Comprehensive Plan" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Transect", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 131, 117, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 255, 255, 0 ], "width": 2 } }, "value": "Natural and Open Space", "label": "1 Parks and Open Space" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 170, 170, 170, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSNull", "color": [ 0, 0, 0, 0 ], "width": 0 } }, "value": "Industrial", "label": "3 Industrial" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 245, 211, 18, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 255, 255, 0 ], "width": 2 } }, "value": "Suburban", "label": "4 Suburban" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 238, 118, 35, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 170, 0, 0 ], "width": 3 } }, "value": "General Urban", "label": "5 General Urban" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 153, 51, 51, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 170, 0, 0 ], "width": 3 } }, "value": "Mixed Use Centers and Corridors", "label": "6 Mixed Use Centers and Corridors" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 187, 158, 117, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 255, 255, 0 ], "width": 2 } }, "value": "Urban Core", "label": "7 Urban Core" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 54, 74, 97, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 255, 255, 0 ], "width": 2 } }, "value": "Special Use", "label": "8 Special Use" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 50, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 662747.3640000001, "ymin": 640769.5399999991, "xmax": 707273.2749999985, "ymax": 696379.2929999977, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Transect", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Transect", "type": "esriFieldTypeString", "alias": "Transect", "length": 40, "domain": { "type": "codedValue", "name": "WS3_PLN Comprehensive Plan 2022 Tract Transect", "description": "Valid planning comprehensive plan 2022 tract transect values", "codedValues": [ { "name": "General Urban", "code": "General Urban" }, { "name": "Industrial", "code": "Industrial" }, { "name": "Mixed Use Centers and Corridors", "code": "Mixed Use Centers and Corridors" }, { "name": "Natural and Open Space", "code": "Natural and Open Space" }, { "name": "Special Use", "code": "Special Use" }, { "name": "Suburban", "code": "Suburban" }, { "name": "Urban Core", "code": "Urban Core" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S206_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 800, "name": "Land Use", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 810, "name": "Area of Impact" }, { "id": 820, "name": "Land Use" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 669337.9004999995, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 693960.124499999, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 810, "name": "Area of Impact", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 800, "name": "Land Use" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 54, 74, 97, 0 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 238, 118, 35, 255 ], "width": 2 } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 669337.9004999995, "ymin": 638198.1115000024, "xmax": 712633.4855000004, "ymax": 693960.124499999, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GlobalID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 100, "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 20, "domain": { "type": "codedValue", "name": "WS3_AOI Type", "description": "Valid area of impact type values", "codedValues": [ { "name": "Active", "code": "Active" }, { "name": "Inactive", "code": "Inactive" }, { "name": "Proposed", "code": "Proposed" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "ActiveDate", "type": "esriFieldTypeDate", "alias": "Active Date", "length": 8, "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": {}, "indexes": [ { "name": "UUID_25", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075261000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 820, "name": "Land Use", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 800, "name": "Land Use" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "StandardLandUseType", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 190, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSNull", "color": [ 0, 0, 0, 0 ], "width": 0 } }, "value": "10", "label": "SFD - Single Family Dwelling" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 190, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "40", "label": "ACB - Accessory Building/Structure" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 211, 127, 255 ], "outline": null }, "value": "20", "label": "MFD - Multi-Family Dwelling" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 230, 230, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "30", "label": "RSL - Other Residential" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 127, 127, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "80", "label": "RTL - Retail Trade" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 223, 115, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "70", "label": "WHL - Wholesale Trade" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 190, 232, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "100", "label": "SRV - Services" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 205, 102, 102, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "110", "label": "CBDRL - Central Business District Retail Trade" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 205, 102, 102, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "120", "label": "CBDSV - Central Business District Services" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 223, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "90", "label": "EDU - Educational" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 163, 255, 115, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "130", "label": "CER - Cultural, Entertainment & Recreation" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 130, 130, 130, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "50", "label": "I&M - Industrial & Manufacturing" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 178, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "60", "label": "TCU - Transportation, Communication & Utilites" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 233, 255, 190, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "140", "label": "AGL - Agricultural" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 158, 187, 215, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "150", "label": "MNG - Mining" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 225, 225, 225, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "160", "label": "VCT - Vacant" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "180", "label": "ROW - Streets & Right-of-Ways" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 191, 217, 242, 255 ], "outline": null }, "value": "170", "label": "WTR - Water Areas" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 188, 252, 179, 255 ], "toColor": [ 188, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 235, 252, 255 ], "toColor": [ 179, 235, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 179, 252, 255 ], "toColor": [ 216, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 244, 199, 255 ], "toColor": [ 252, 244, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 204, 252, 220, 255 ], "toColor": [ 204, 252, 220, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 246, 212, 252, 255 ], "toColor": [ 246, 212, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 182, 204, 252, 255 ], "toColor": [ 182, 204, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 207, 182, 255 ], "toColor": [ 252, 207, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 251, 255 ], "toColor": [ 252, 184, 251, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 183, 252, 255 ], "toColor": [ 179, 183, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 252, 246, 255 ], "toColor": [ 212, 252, 246, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 223, 252, 184, 255 ], "toColor": [ 223, 252, 184, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 215, 232, 255 ], "toColor": [ 252, 215, 232, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 215, 229, 252, 255 ], "toColor": [ 215, 229, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 210, 199, 252, 255 ], "toColor": [ 210, 199, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 182, 212, 255 ], "toColor": [ 252, 182, 212, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 189, 252, 200, 255 ], "toColor": [ 189, 252, 200, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 25, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674610.0245000012, "ymin": 643478.2014999986, "xmax": 707353.4959999993, "ymax": 689855.8580000028, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "StandardLandUseType", "typeIdField": "StandardLandUseType", "subtypeFieldName": "StandardLandUseType", "subtypeField": "StandardLandUseType", "defaultSubtypeCode": 10, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "StandardLandUseType", "type": "esriFieldTypeSmallInteger", "alias": "Standard Land Use Type", "domain": null }, { "name": "StandardLandUseCode", "type": "esriFieldTypeSmallInteger", "alias": "Standard Land Use Code", "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I491StandardLand", "fields": "StandardLandUseCode", "isAscending": true, "isUnique": false, "description": "" }, { "name": "I491StandardLand_1", "fields": "StandardLandUseType", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_235", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S198_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "types": [ { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SFD", "description": "Valid standard land use code SFD values", "codedValues": [ { "name": "1110 - Single Family Detached", "code": 1110 }, { "name": "1140 - Townhome/Single Family Attached (separate ownership)", "code": 1140 }, { "name": "1150 - Mobile Home", "code": 1150 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 10, "name": "SFD - Single Family Dwelling" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC MFD", "description": "Valid standard land use code MFD values", "codedValues": [ { "name": "1120 - Two Units", "code": 1120 }, { "name": "1130 - Three or More Units", "code": 1130 }, { "name": "1300 - Residential Motel", "code": 1300 }, { "name": "1400 - Mobile Home Park", "code": 1400 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 20, "name": "MFD - Multi-Family Dwelling" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RSL", "description": "Valid standard land use code RSL values", "codedValues": [ { "name": "1210 - Group Home", "code": 1210 }, { "name": "1241 - Retirement Home", "code": 1241 }, { "name": "1500 - Hotel/Motel", "code": 1500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 30, "name": "RSL - Other Residential" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC ACB", "description": "Valid standard land use ACB values", "codedValues": [ { "name": "1950 - Detached Garage", "code": 1950 }, { "name": "1951 - Attached Garage", "code": 1951 }, { "name": "1952 - Covered Carport", "code": 1952 }, { "name": "1958 - Pool House", "code": 1958 }, { "name": "1960 - Shed", "code": 1960 }, { "name": "1970 - Deck", "code": 1970 }, { "name": "1971 - Pergola, Covered Deck, Patio Cover", "code": 1971 }, { "name": "1972 - Green House", "code": 1972 }, { "name": "1975 - ADA Ramp", "code": 1975 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 40, "name": "ACB - Accessory Building/Structure" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC I&M", "description": "Valid standard land use code I&M values", "codedValues": [ { "name": "2100 - Food and Kindred Products", "code": 2100 }, { "name": "2200 - Textile Products", "code": 2200 }, { "name": "2300 - Apparel & other finished products made from fabrics, leather or similar", "code": 2300 }, { "name": "2400 - Lumber & Wood Products (except furniture)", "code": 2400 }, { "name": "2500 - Furniture & Fixtures", "code": 2500 }, { "name": "2600 - Paper & Allied Products", "code": 2600 }, { "name": "2700 - Printing, Publishing & Allied Industries", "code": 2700 }, { "name": "2800 - Chemicals & Allied Products", "code": 2800 }, { "name": "2900 - Petroleum Refining & Related Industries", "code": 2900 }, { "name": "3100 - Rubber & Miscellaneous Plastic Products", "code": 3100 }, { "name": "3200 - Stone, Clay & Glass Products", "code": 3200 }, { "name": "3300 - Metal Industries", "code": 3300 }, { "name": "3400 - Fabricated Metal Products", "code": 3400 }, { "name": "3500 - Professional, Scientific & Controlling Instruments; Research Instruments & Associated", "code": 3500 }, { "name": "3900 - Miscellaneous Manufacturing", "code": 3900 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 50, "name": "I&M - Industrial & Manufacturing" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC TCU", "description": "Valid standard land use code TCU values", "codedValues": [ { "name": "4110 - Railroad Transportation", "code": 4110 }, { "name": "4210 - Bus Transportation", "code": 4210 }, { "name": "4220 - Motor Freight Transportation", "code": 4220 }, { "name": "4291 - Taxicab Transportation", "code": 4291 }, { "name": "4292 - Passenger Autos for Rent with Driver", "code": 4292 }, { "name": "4294 - Ambulance Service", "code": 4294 }, { "name": "4295 - Parcel Delivery & Pickup and Delivery Service", "code": 4295 }, { "name": "4299 - Other Motor Vehicle Transportation", "code": 4299 }, { "name": "4310 - Airport", "code": 4310 }, { "name": "4510 - Freeway", "code": 4510 }, { "name": "4520 - Principle Arterial", "code": 4520 }, { "name": "4530 - Major Arterial", "code": 4530 }, { "name": "4540 - Collector", "code": 4540 }, { "name": "4550 - Local", "code": 4550 }, { "name": "4560 - Alley", "code": 4560 }, { "name": "4599 - Neighborhood Walking Path", "code": 4599 }, { "name": "4600 - Automobile Parking", "code": 4600 }, { "name": "4710 - Telephone Communication", "code": 4710 }, { "name": "4712 - Cell Tower", "code": 4712 }, { "name": "4730 - Radio Communication", "code": 4730 }, { "name": "4731 - Radio Broadcasting Station", "code": 4731 }, { "name": "4732 - Radio Tower", "code": 4732 }, { "name": "4740 - Television Communication", "code": 4740 }, { "name": "4741 - Television Broadcasting Station", "code": 4741 }, { "name": "4742 - Television Tower", "code": 4742 }, { "name": "4810 - Electric Utility", "code": 4810 }, { "name": "4812 - Electric Generation Plant", "code": 4812 }, { "name": "4813 - Electric Substation", "code": 4813 }, { "name": "4818 - Wind Farm", "code": 4818 }, { "name": "4820 - Gas Utility", "code": 4820 }, { "name": "4830 - Water Utility", "code": 4830 }, { "name": "4832 - Water Treatment Plant", "code": 4832 }, { "name": "4833 - Water Storage", "code": 4833 }, { "name": "4834 - Water Storage - Covered", "code": 4834 }, { "name": "4840 - Sewage Disposal", "code": 4840 }, { "name": "4841 - Sewage Treatment Plant", "code": 4841 }, { "name": "4874 - Storm Pond", "code": 4874 }, { "name": "4890 - Fiber Utility", "code": 4890 }, { "name": "4891 - Internet Service Provider", "code": 4891 }, { "name": "4920 - Transportation Services & Arrangements", "code": 4920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 60, "name": "TCU - Transportation, Communication & Utilites" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC WHL", "description": "Valid standard land use code WHL values", "codedValues": [ { "name": "5110 - Motor Vehicles & Automotive Equipment", "code": 5110 }, { "name": "5120 - Drugs, Chemical, & Allied Products", "code": 5120 }, { "name": "5130 - Dry Goods & Apparel", "code": 5130 }, { "name": "5140 - Groceries & Related Products", "code": 5140 }, { "name": "5150 - Farm Products", "code": 5150 }, { "name": "5160 - Electrical Goods", "code": 5160 }, { "name": "5170 - Hardware, Plumbing, Heating Equipment & Supplies", "code": 5170 }, { "name": "5180 - Machinery, Equipment & Supplies", "code": 5180 }, { "name": "5190 - Miscellaneous Wholesale", "code": 5190 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 70, "name": "WHL - Wholesale Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RTL", "description": "Valid standard land use code RTL values", "codedValues": [ { "name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies", "code": 5200 }, { "name": "5300 - General Merchandise", "code": 5300 }, { "name": "5310 - Shopping Center/Mall", "code": 5310 }, { "name": "5311 - Department Store", "code": 5311 }, { "name": "5312 - Discount Department Store", "code": 5312 }, { "name": "5313 - Surplus Store", "code": 5313 }, { "name": "5330 - Variety Store", "code": 5330 }, { "name": "5350 - Direct Selling Organization", "code": 5350 }, { "name": "5390 - Other Retail Trade - General Merchandise", "code": 5390 }, { "name": "5411 - Grocery Store/Supermarket", "code": 5411 }, { "name": "5412 - Convenience Store", "code": 5412 }, { "name": "5420 - Meat & Fish", "code": 5420 }, { "name": "5430 - Produce", "code": 5430 }, { "name": "5440 - Candy & Confectionery", "code": 5440 }, { "name": "5450 - Dairy Products", "code": 5450 }, { "name": "5460 - Bakeries & Donut Shops", "code": 5460 }, { "name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)", "code": 5490 }, { "name": "5510 - Motor Vehicles", "code": 5510 }, { "name": "5520 - Tires, Batteries & Accessories (auto parts stores)", "code": 5520 }, { "name": "5530 - Gas Station", "code": 5530 }, { "name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories", "code": 5590 }, { "name": "5600 - Apparel & Accessories", "code": 5600 }, { "name": "5710 - Furniture, Home Furnishings & Equipment", "code": 5710 }, { "name": "5720 - Household Appliances", "code": 5720 }, { "name": "5730 - Electronics", "code": 5730 }, { "name": "5740 - Office Equipment & Furniture", "code": 5740 }, { "name": "5811 - Restaurants (with or without liquor)", "code": 5811 }, { "name": "5812 - Short Order Sit Down", "code": 5812 }, { "name": "5813 - Short Order Drive-In", "code": 5813 }, { "name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)", "code": 5814 }, { "name": "5820 - Drinking Places - Alcoholic Beverages", "code": 5820 }, { "name": "5910 - Drug & Pharmacy", "code": 5910 }, { "name": "5920 - Liquor Store", "code": 5920 }, { "name": "5930 - Antiques & Secondhand Merchandise", "code": 5930 }, { "name": "5940 - Books, Stationery, Art & Hobby Supplies", "code": 5940 }, { "name": "5950 - Sporting Goods", "code": 5950 }, { "name": "5960 - Farm & Garden Supplies", "code": 5960 }, { "name": "5969 - Nursery Plants & Garden Supplies", "code": 5969 }, { "name": "5970 - Jewelry Store", "code": 5970 }, { "name": "5980 - Fuel & Ice", "code": 5980 }, { "name": "5990 - Miscellaneous Retail Trade", "code": 5990 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 80, "name": "RTL - Retail Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC EDU", "description": "Valid standard land use code EDU values", "codedValues": [ { "name": "6811 - Kindergarten (Head Start)", "code": 6811 }, { "name": "6812 - Elementary", "code": 6812 }, { "name": "6813 - Junior High", "code": 6813 }, { "name": "6814 - Senior High", "code": 6814 }, { "name": "6818 - District Office", "code": 6818 }, { "name": "6821 - University or College", "code": 6821 }, { "name": "6831 - Vocational or Trade", "code": 6831 }, { "name": "6833 - Barber & Beauty School", "code": 6833 }, { "name": "6834 - Art, Drama & Music School", "code": 6834 }, { "name": "6835 - Dancing School", "code": 6835 }, { "name": "6836 - Driving School", "code": 6836 }, { "name": "6837 - Online & Correspondence School", "code": 6837 }, { "name": "6838 - Language School", "code": 6838 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 90, "name": "EDU - Educational" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SRV", "description": "Valid standard land use code SRV values", "codedValues": [ { "name": "6110 - Banking & Related Functions", "code": 6110 }, { "name": "6120 - Credit Services", "code": 6120 }, { "name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services", "code": 6130 }, { "name": "6140 - Insurance Carriers, Agents, Brokers & Services", "code": 6140 }, { "name": "6150 - Real Estate & Related Services", "code": 6150 }, { "name": "6160 - Holding & Investment Services", "code": 6160 }, { "name": "6210 - Laundering & Dry Cleaning", "code": 6210 }, { "name": "6220 - Photographic Services", "code": 6220 }, { "name": "6230 - Beauty & Barber Services", "code": 6230 }, { "name": "6241 - Funeral Home", "code": 6241 }, { "name": "6242 - Cemeteries", "code": 6242 }, { "name": "6243 - Crematory", "code": 6243 }, { "name": "6250 - Apparel & Shoe Repair", "code": 6250 }, { "name": "6291 - Clothing Rental", "code": 6291 }, { "name": "6292 - Costume Rental", "code": 6292 }, { "name": "6295 - Tattooing", "code": 6295 }, { "name": "6296 - Massage Parlors", "code": 6296 }, { "name": "6310 - Advertising Services", "code": 6310 }, { "name": "6320 - Credit Reporting Services, Adjustment & Collections Services", "code": 6320 }, { "name": "6330 - Duplicating, Mailing & Office Services", "code": 6330 }, { "name": "6340 - Dwelling Cleaning, Maintenance & Building Services", "code": 6340 }, { "name": "6360 - Employment Services", "code": 6360 }, { "name": "6370 - Warehousing & Storage Services", "code": 6370 }, { "name": "6371 - Farming Products Warehousing", "code": 6371 }, { "name": "6372 - Stockyards", "code": 6372 }, { "name": "6390 - Business Services", "code": 6390 }, { "name": "6410 - Automobile Repair & Related Services", "code": 6410 }, { "name": "6420 - Electrical Appliance Repair & Services", "code": 6420 }, { "name": "6490 - Repair Shops & Related Services", "code": 6490 }, { "name": "6511 - Physicians Office", "code": 6511 }, { "name": "6512 - Dental Office", "code": 6512 }, { "name": "6513 - Hospital", "code": 6513 }, { "name": "6516 - Rest Home", "code": 6516 }, { "name": "6517 - Medical Clinic/Emergency Centers", "code": 6517 }, { "name": "6520 - Legal Services", "code": 6520 }, { "name": "6530 - Engineering, Architectural & Planning Services", "code": 6530 }, { "name": "6540 - Research Services (INL)", "code": 6540 }, { "name": "6590 - Other Professional Services", "code": 6590 }, { "name": "6600 - Contract Construction Services", "code": 6600 }, { "name": "6700 - Governmental Services", "code": 6700 }, { "name": "6710 - Executive, Legislative & Judicial Functions", "code": 6710 }, { "name": "6721 - Police Services", "code": 6721 }, { "name": "6723 - Fire Services", "code": 6723 }, { "name": "6724 - Civil Defense", "code": 6724 }, { "name": "6725 - Health Services", "code": 6725 }, { "name": "6730 - Postal Services (Government)", "code": 6730 }, { "name": "6740 - Correctional Institution", "code": 6740 }, { "name": "6815 - Day Care Center", "code": 6815 }, { "name": "6911 - Church, Synagogue & Temple", "code": 6911 }, { "name": "6920 - Welfare & Charitable Services", "code": 6920 }, { "name": "6930 - Business, Professional & Labor Organizations & Services", "code": 6930 }, { "name": "6940 - Social, Fraternal & Youth Organizations & Services", "code": 6940 }, { "name": "6950 - Political, Civic & Veterans Organizations", "code": 6950 }, { "name": "6960 - Organizations & Clubs", "code": 6960 }, { "name": "6990 - Recycling Center", "code": 6990 }, { "name": "6994 - Senior Citizens Center", "code": 6994 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 100, "name": "SRV - Services" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RTL", "description": "Valid standard land use code RTL values", "codedValues": [ { "name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies", "code": 5200 }, { "name": "5300 - General Merchandise", "code": 5300 }, { "name": "5310 - Shopping Center/Mall", "code": 5310 }, { "name": "5311 - Department Store", "code": 5311 }, { "name": "5312 - Discount Department Store", "code": 5312 }, { "name": "5313 - Surplus Store", "code": 5313 }, { "name": "5330 - Variety Store", "code": 5330 }, { "name": "5350 - Direct Selling Organization", "code": 5350 }, { "name": "5390 - Other Retail Trade - General Merchandise", "code": 5390 }, { "name": "5411 - Grocery Store/Supermarket", "code": 5411 }, { "name": "5412 - Convenience Store", "code": 5412 }, { "name": "5420 - Meat & Fish", "code": 5420 }, { "name": "5430 - Produce", "code": 5430 }, { "name": "5440 - Candy & Confectionery", "code": 5440 }, { "name": "5450 - Dairy Products", "code": 5450 }, { "name": "5460 - Bakeries & Donut Shops", "code": 5460 }, { "name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)", "code": 5490 }, { "name": "5510 - Motor Vehicles", "code": 5510 }, { "name": "5520 - Tires, Batteries & Accessories (auto parts stores)", "code": 5520 }, { "name": "5530 - Gas Station", "code": 5530 }, { "name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories", "code": 5590 }, { "name": "5600 - Apparel & Accessories", "code": 5600 }, { "name": "5710 - Furniture, Home Furnishings & Equipment", "code": 5710 }, { "name": "5720 - Household Appliances", "code": 5720 }, { "name": "5730 - Electronics", "code": 5730 }, { "name": "5740 - Office Equipment & Furniture", "code": 5740 }, { "name": "5811 - Restaurants (with or without liquor)", "code": 5811 }, { "name": "5812 - Short Order Sit Down", "code": 5812 }, { "name": "5813 - Short Order Drive-In", "code": 5813 }, { "name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)", "code": 5814 }, { "name": "5820 - Drinking Places - Alcoholic Beverages", "code": 5820 }, { "name": "5910 - Drug & Pharmacy", "code": 5910 }, { "name": "5920 - Liquor Store", "code": 5920 }, { "name": "5930 - Antiques & Secondhand Merchandise", "code": 5930 }, { "name": "5940 - Books, Stationery, Art & Hobby Supplies", "code": 5940 }, { "name": "5950 - Sporting Goods", "code": 5950 }, { "name": "5960 - Farm & Garden Supplies", "code": 5960 }, { "name": "5969 - Nursery Plants & Garden Supplies", "code": 5969 }, { "name": "5970 - Jewelry Store", "code": 5970 }, { "name": "5980 - Fuel & Ice", "code": 5980 }, { "name": "5990 - Miscellaneous Retail Trade", "code": 5990 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 110, "name": "CBDRL - Central Business District Retail Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SRV", "description": "Valid standard land use code SRV values", "codedValues": [ { "name": "6110 - Banking & Related Functions", "code": 6110 }, { "name": "6120 - Credit Services", "code": 6120 }, { "name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services", "code": 6130 }, { "name": "6140 - Insurance Carriers, Agents, Brokers & Services", "code": 6140 }, { "name": "6150 - Real Estate & Related Services", "code": 6150 }, { "name": "6160 - Holding & Investment Services", "code": 6160 }, { "name": "6210 - Laundering & Dry Cleaning", "code": 6210 }, { "name": "6220 - Photographic Services", "code": 6220 }, { "name": "6230 - Beauty & Barber Services", "code": 6230 }, { "name": "6241 - Funeral Home", "code": 6241 }, { "name": "6242 - Cemeteries", "code": 6242 }, { "name": "6243 - Crematory", "code": 6243 }, { "name": "6250 - Apparel & Shoe Repair", "code": 6250 }, { "name": "6291 - Clothing Rental", "code": 6291 }, { "name": "6292 - Costume Rental", "code": 6292 }, { "name": "6295 - Tattooing", "code": 6295 }, { "name": "6296 - Massage Parlors", "code": 6296 }, { "name": "6310 - Advertising Services", "code": 6310 }, { "name": "6320 - Credit Reporting Services, Adjustment & Collections Services", "code": 6320 }, { "name": "6330 - Duplicating, Mailing & Office Services", "code": 6330 }, { "name": "6340 - Dwelling Cleaning, Maintenance & Building Services", "code": 6340 }, { "name": "6360 - Employment Services", "code": 6360 }, { "name": "6370 - Warehousing & Storage Services", "code": 6370 }, { "name": "6371 - Farming Products Warehousing", "code": 6371 }, { "name": "6372 - Stockyards", "code": 6372 }, { "name": "6390 - Business Services", "code": 6390 }, { "name": "6410 - Automobile Repair & Related Services", "code": 6410 }, { "name": "6420 - Electrical Appliance Repair & Services", "code": 6420 }, { "name": "6490 - Repair Shops & Related Services", "code": 6490 }, { "name": "6511 - Physicians Office", "code": 6511 }, { "name": "6512 - Dental Office", "code": 6512 }, { "name": "6513 - Hospital", "code": 6513 }, { "name": "6516 - Rest Home", "code": 6516 }, { "name": "6517 - Medical Clinic/Emergency Centers", "code": 6517 }, { "name": "6520 - Legal Services", "code": 6520 }, { "name": "6530 - Engineering, Architectural & Planning Services", "code": 6530 }, { "name": "6540 - Research Services (INL)", "code": 6540 }, { "name": "6590 - Other Professional Services", "code": 6590 }, { "name": "6600 - Contract Construction Services", "code": 6600 }, { "name": "6700 - Governmental Services", "code": 6700 }, { "name": "6710 - Executive, Legislative & Judicial Functions", "code": 6710 }, { "name": "6721 - Police Services", "code": 6721 }, { "name": "6723 - Fire Services", "code": 6723 }, { "name": "6724 - Civil Defense", "code": 6724 }, { "name": "6725 - Health Services", "code": 6725 }, { "name": "6730 - Postal Services (Government)", "code": 6730 }, { "name": "6740 - Correctional Institution", "code": 6740 }, { "name": "6815 - Day Care Center", "code": 6815 }, { "name": "6911 - Church, Synagogue & Temple", "code": 6911 }, { "name": "6920 - Welfare & Charitable Services", "code": 6920 }, { "name": "6930 - Business, Professional & Labor Organizations & Services", "code": 6930 }, { "name": "6940 - Social, Fraternal & Youth Organizations & Services", "code": 6940 }, { "name": "6950 - Political, Civic & Veterans Organizations", "code": 6950 }, { "name": "6960 - Organizations & Clubs", "code": 6960 }, { "name": "6990 - Recycling Center", "code": 6990 }, { "name": "6994 - Senior Citizens Center", "code": 6994 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 120, "name": "CBDSV - Central Business District Services" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC CER", "description": "Valid standard land use CER values", "codedValues": [ { "name": "7111 - Library", "code": 7111 }, { "name": "7112 - Museum", "code": 7112 }, { "name": "7113 - Art Gallery", "code": 7113 }, { "name": "7123 - Botanical Garden", "code": 7123 }, { "name": "7124 - Zoo", "code": 7124 }, { "name": "7191 - Historical & Monument Site", "code": 7191 }, { "name": "7212 - Theater", "code": 7212 }, { "name": "7213 - Drive-in Theater", "code": 7213 }, { "name": "7221 - Stadium", "code": 7221 }, { "name": "7222 - Arena", "code": 7222 }, { "name": "7223 - Race Track - Animal", "code": 7223 }, { "name": "7224 - Race Track - Auto", "code": 7224 }, { "name": "7231 - Auditorium", "code": 7231 }, { "name": "7232 - Exhibition Hall", "code": 7232 }, { "name": "7233 - Convention Center", "code": 7233 }, { "name": "7234 - Civic Theater", "code": 7234 }, { "name": "7311 - Fairgrounds", "code": 7311 }, { "name": "7312 - Amusement Park", "code": 7312 }, { "name": "7391 - Arcade", "code": 7391 }, { "name": "7392 - Miniature Golf", "code": 7392 }, { "name": "7396 - Dance Hall", "code": 7396 }, { "name": "7397 - Billiard", "code": 7397 }, { "name": "7411 - Golf Course - Public", "code": 7411 }, { "name": "7412 - Golf Course - Private", "code": 7412 }, { "name": "7413 - Tennis Court", "code": 7413 }, { "name": "7414 - Ice Skating", "code": 7414 }, { "name": "7415 - Roller Skating", "code": 7415 }, { "name": "7416 - Riding Academy", "code": 7416 }, { "name": "7417 - Bowling Alley", "code": 7417 }, { "name": "7421 - Playground", "code": 7421 }, { "name": "7423 - Athletic Field", "code": 7423 }, { "name": "7424 - Recreation & Community Center", "code": 7424 }, { "name": "7425 - Gymnasium", "code": 7425 }, { "name": "7426 - Baseball Field", "code": 7426 }, { "name": "7432 - Swimming Pool", "code": 7432 }, { "name": "7433 - Water Park", "code": 7433 }, { "name": "7442 - Boat Access Site", "code": 7442 }, { "name": "7443 - Sports Fishing Activities", "code": 7443 }, { "name": "7451 - Archery Range", "code": 7451 }, { "name": "7452 - Gun Range", "code": 7452 }, { "name": "7491 - RV Parking & Camping Area", "code": 7491 }, { "name": "7611 - Developed Park", "code": 7611 }, { "name": "7612 - Undeveloped Park", "code": 7612 }, { "name": "7621 - Green Belt", "code": 7621 }, { "name": "7691 - Landscaped Lot", "code": 7691 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 130, "name": "CER - Cultural, Entertainment & Recreation" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC AGL", "description": "Valid standard land use code AGL values", "codedValues": [ { "name": "8100 - Agriculture", "code": 8100 }, { "name": "8144 - Dairy", "code": 8144 }, { "name": "8221 - Veterinarian", "code": 8221 }, { "name": "8224 - Kennel", "code": 8224 }, { "name": "8292 - Tree Planting, Pruning, Spraying", "code": 8292 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 140, "name": "AGL - Agricultural" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC MNG", "description": "Valid standard land use code MNG values", "codedValues": [ { "name": "8543 - Gravel Pit", "code": 8543 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 150, "name": "MNG - Mining" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC VCT", "description": "Valid standard land use code VCT values", "codedValues": [ { "name": "9100 - Vacant Land", "code": 9100 }, { "name": "9400 - Vacant Building", "code": 9400 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 160, "name": "VCT - Vacant" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC WTR", "description": "Valid standard land use code WTR values", "codedValues": [ { "name": "9310 - Snake River", "code": 9310 }, { "name": "9311 - Canal/Stream", "code": 9311 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 170, "name": "WTR - Water Areas" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC ROW", "description": "Valid standard land use code ROW values", "codedValues": [ { "name": "4500 - Highway and Street Right-of-Way", "code": 4500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "id": 180, "name": "ROW - Streets & Right-of-Ways" } ], "subtypes": [ { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SFD", "description": "Valid standard land use code SFD values", "codedValues": [ { "name": "1110 - Single Family Detached", "code": 1110 }, { "name": "1140 - Townhome/Single Family Attached (separate ownership)", "code": 1140 }, { "name": "1150 - Mobile Home", "code": 1150 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 10, "name": "SFD - Single Family Dwelling" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC MFD", "description": "Valid standard land use code MFD values", "codedValues": [ { "name": "1120 - Two Units", "code": 1120 }, { "name": "1130 - Three or More Units", "code": 1130 }, { "name": "1300 - Residential Motel", "code": 1300 }, { "name": "1400 - Mobile Home Park", "code": 1400 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 20, "name": "MFD - Multi-Family Dwelling" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RSL", "description": "Valid standard land use code RSL values", "codedValues": [ { "name": "1210 - Group Home", "code": 1210 }, { "name": "1241 - Retirement Home", "code": 1241 }, { "name": "1500 - Hotel/Motel", "code": 1500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 30, "name": "RSL - Other Residential" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC ACB", "description": "Valid standard land use ACB values", "codedValues": [ { "name": "1950 - Detached Garage", "code": 1950 }, { "name": "1951 - Attached Garage", "code": 1951 }, { "name": "1952 - Covered Carport", "code": 1952 }, { "name": "1958 - Pool House", "code": 1958 }, { "name": "1960 - Shed", "code": 1960 }, { "name": "1970 - Deck", "code": 1970 }, { "name": "1971 - Pergola, Covered Deck, Patio Cover", "code": 1971 }, { "name": "1972 - Green House", "code": 1972 }, { "name": "1975 - ADA Ramp", "code": 1975 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 40, "name": "ACB - Accessory Building/Structure" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC I&M", "description": "Valid standard land use code I&M values", "codedValues": [ { "name": "2100 - Food and Kindred Products", "code": 2100 }, { "name": "2200 - Textile Products", "code": 2200 }, { "name": "2300 - Apparel & other finished products made from fabrics, leather or similar", "code": 2300 }, { "name": "2400 - Lumber & Wood Products (except furniture)", "code": 2400 }, { "name": "2500 - Furniture & Fixtures", "code": 2500 }, { "name": "2600 - Paper & Allied Products", "code": 2600 }, { "name": "2700 - Printing, Publishing & Allied Industries", "code": 2700 }, { "name": "2800 - Chemicals & Allied Products", "code": 2800 }, { "name": "2900 - Petroleum Refining & Related Industries", "code": 2900 }, { "name": "3100 - Rubber & Miscellaneous Plastic Products", "code": 3100 }, { "name": "3200 - Stone, Clay & Glass Products", "code": 3200 }, { "name": "3300 - Metal Industries", "code": 3300 }, { "name": "3400 - Fabricated Metal Products", "code": 3400 }, { "name": "3500 - Professional, Scientific & Controlling Instruments; Research Instruments & Associated", "code": 3500 }, { "name": "3900 - Miscellaneous Manufacturing", "code": 3900 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 50, "name": "I&M - Industrial & Manufacturing" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC TCU", "description": "Valid standard land use code TCU values", "codedValues": [ { "name": "4110 - Railroad Transportation", "code": 4110 }, { "name": "4210 - Bus Transportation", "code": 4210 }, { "name": "4220 - Motor Freight Transportation", "code": 4220 }, { "name": "4291 - Taxicab Transportation", "code": 4291 }, { "name": "4292 - Passenger Autos for Rent with Driver", "code": 4292 }, { "name": "4294 - Ambulance Service", "code": 4294 }, { "name": "4295 - Parcel Delivery & Pickup and Delivery Service", "code": 4295 }, { "name": "4299 - Other Motor Vehicle Transportation", "code": 4299 }, { "name": "4310 - Airport", "code": 4310 }, { "name": "4510 - Freeway", "code": 4510 }, { "name": "4520 - Principle Arterial", "code": 4520 }, { "name": "4530 - Major Arterial", "code": 4530 }, { "name": "4540 - Collector", "code": 4540 }, { "name": "4550 - Local", "code": 4550 }, { "name": "4560 - Alley", "code": 4560 }, { "name": "4599 - Neighborhood Walking Path", "code": 4599 }, { "name": "4600 - Automobile Parking", "code": 4600 }, { "name": "4710 - Telephone Communication", "code": 4710 }, { "name": "4712 - Cell Tower", "code": 4712 }, { "name": "4730 - Radio Communication", "code": 4730 }, { "name": "4731 - Radio Broadcasting Station", "code": 4731 }, { "name": "4732 - Radio Tower", "code": 4732 }, { "name": "4740 - Television Communication", "code": 4740 }, { "name": "4741 - Television Broadcasting Station", "code": 4741 }, { "name": "4742 - Television Tower", "code": 4742 }, { "name": "4810 - Electric Utility", "code": 4810 }, { "name": "4812 - Electric Generation Plant", "code": 4812 }, { "name": "4813 - Electric Substation", "code": 4813 }, { "name": "4818 - Wind Farm", "code": 4818 }, { "name": "4820 - Gas Utility", "code": 4820 }, { "name": "4830 - Water Utility", "code": 4830 }, { "name": "4832 - Water Treatment Plant", "code": 4832 }, { "name": "4833 - Water Storage", "code": 4833 }, { "name": "4834 - Water Storage - Covered", "code": 4834 }, { "name": "4840 - Sewage Disposal", "code": 4840 }, { "name": "4841 - Sewage Treatment Plant", "code": 4841 }, { "name": "4874 - Storm Pond", "code": 4874 }, { "name": "4890 - Fiber Utility", "code": 4890 }, { "name": "4891 - Internet Service Provider", "code": 4891 }, { "name": "4920 - Transportation Services & Arrangements", "code": 4920 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 60, "name": "TCU - Transportation, Communication & Utilites" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC WHL", "description": "Valid standard land use code WHL values", "codedValues": [ { "name": "5110 - Motor Vehicles & Automotive Equipment", "code": 5110 }, { "name": "5120 - Drugs, Chemical, & Allied Products", "code": 5120 }, { "name": "5130 - Dry Goods & Apparel", "code": 5130 }, { "name": "5140 - Groceries & Related Products", "code": 5140 }, { "name": "5150 - Farm Products", "code": 5150 }, { "name": "5160 - Electrical Goods", "code": 5160 }, { "name": "5170 - Hardware, Plumbing, Heating Equipment & Supplies", "code": 5170 }, { "name": "5180 - Machinery, Equipment & Supplies", "code": 5180 }, { "name": "5190 - Miscellaneous Wholesale", "code": 5190 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 70, "name": "WHL - Wholesale Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RTL", "description": "Valid standard land use code RTL values", "codedValues": [ { "name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies", "code": 5200 }, { "name": "5300 - General Merchandise", "code": 5300 }, { "name": "5310 - Shopping Center/Mall", "code": 5310 }, { "name": "5311 - Department Store", "code": 5311 }, { "name": "5312 - Discount Department Store", "code": 5312 }, { "name": "5313 - Surplus Store", "code": 5313 }, { "name": "5330 - Variety Store", "code": 5330 }, { "name": "5350 - Direct Selling Organization", "code": 5350 }, { "name": "5390 - Other Retail Trade - General Merchandise", "code": 5390 }, { "name": "5411 - Grocery Store/Supermarket", "code": 5411 }, { "name": "5412 - Convenience Store", "code": 5412 }, { "name": "5420 - Meat & Fish", "code": 5420 }, { "name": "5430 - Produce", "code": 5430 }, { "name": "5440 - Candy & Confectionery", "code": 5440 }, { "name": "5450 - Dairy Products", "code": 5450 }, { "name": "5460 - Bakeries & Donut Shops", "code": 5460 }, { "name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)", "code": 5490 }, { "name": "5510 - Motor Vehicles", "code": 5510 }, { "name": "5520 - Tires, Batteries & Accessories (auto parts stores)", "code": 5520 }, { "name": "5530 - Gas Station", "code": 5530 }, { "name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories", "code": 5590 }, { "name": "5600 - Apparel & Accessories", "code": 5600 }, { "name": "5710 - Furniture, Home Furnishings & Equipment", "code": 5710 }, { "name": "5720 - Household Appliances", "code": 5720 }, { "name": "5730 - Electronics", "code": 5730 }, { "name": "5740 - Office Equipment & Furniture", "code": 5740 }, { "name": "5811 - Restaurants (with or without liquor)", "code": 5811 }, { "name": "5812 - Short Order Sit Down", "code": 5812 }, { "name": "5813 - Short Order Drive-In", "code": 5813 }, { "name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)", "code": 5814 }, { "name": "5820 - Drinking Places - Alcoholic Beverages", "code": 5820 }, { "name": "5910 - Drug & Pharmacy", "code": 5910 }, { "name": "5920 - Liquor Store", "code": 5920 }, { "name": "5930 - Antiques & Secondhand Merchandise", "code": 5930 }, { "name": "5940 - Books, Stationery, Art & Hobby Supplies", "code": 5940 }, { "name": "5950 - Sporting Goods", "code": 5950 }, { "name": "5960 - Farm & Garden Supplies", "code": 5960 }, { "name": "5969 - Nursery Plants & Garden Supplies", "code": 5969 }, { "name": "5970 - Jewelry Store", "code": 5970 }, { "name": "5980 - Fuel & Ice", "code": 5980 }, { "name": "5990 - Miscellaneous Retail Trade", "code": 5990 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 80, "name": "RTL - Retail Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC EDU", "description": "Valid standard land use code EDU values", "codedValues": [ { "name": "6811 - Kindergarten (Head Start)", "code": 6811 }, { "name": "6812 - Elementary", "code": 6812 }, { "name": "6813 - Junior High", "code": 6813 }, { "name": "6814 - Senior High", "code": 6814 }, { "name": "6818 - District Office", "code": 6818 }, { "name": "6821 - University or College", "code": 6821 }, { "name": "6831 - Vocational or Trade", "code": 6831 }, { "name": "6833 - Barber & Beauty School", "code": 6833 }, { "name": "6834 - Art, Drama & Music School", "code": 6834 }, { "name": "6835 - Dancing School", "code": 6835 }, { "name": "6836 - Driving School", "code": 6836 }, { "name": "6837 - Online & Correspondence School", "code": 6837 }, { "name": "6838 - Language School", "code": 6838 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 90, "name": "EDU - Educational" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SRV", "description": "Valid standard land use code SRV values", "codedValues": [ { "name": "6110 - Banking & Related Functions", "code": 6110 }, { "name": "6120 - Credit Services", "code": 6120 }, { "name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services", "code": 6130 }, { "name": "6140 - Insurance Carriers, Agents, Brokers & Services", "code": 6140 }, { "name": "6150 - Real Estate & Related Services", "code": 6150 }, { "name": "6160 - Holding & Investment Services", "code": 6160 }, { "name": "6210 - Laundering & Dry Cleaning", "code": 6210 }, { "name": "6220 - Photographic Services", "code": 6220 }, { "name": "6230 - Beauty & Barber Services", "code": 6230 }, { "name": "6241 - Funeral Home", "code": 6241 }, { "name": "6242 - Cemeteries", "code": 6242 }, { "name": "6243 - Crematory", "code": 6243 }, { "name": "6250 - Apparel & Shoe Repair", "code": 6250 }, { "name": "6291 - Clothing Rental", "code": 6291 }, { "name": "6292 - Costume Rental", "code": 6292 }, { "name": "6295 - Tattooing", "code": 6295 }, { "name": "6296 - Massage Parlors", "code": 6296 }, { "name": "6310 - Advertising Services", "code": 6310 }, { "name": "6320 - Credit Reporting Services, Adjustment & Collections Services", "code": 6320 }, { "name": "6330 - Duplicating, Mailing & Office Services", "code": 6330 }, { "name": "6340 - Dwelling Cleaning, Maintenance & Building Services", "code": 6340 }, { "name": "6360 - Employment Services", "code": 6360 }, { "name": "6370 - Warehousing & Storage Services", "code": 6370 }, { "name": "6371 - Farming Products Warehousing", "code": 6371 }, { "name": "6372 - Stockyards", "code": 6372 }, { "name": "6390 - Business Services", "code": 6390 }, { "name": "6410 - Automobile Repair & Related Services", "code": 6410 }, { "name": "6420 - Electrical Appliance Repair & Services", "code": 6420 }, { "name": "6490 - Repair Shops & Related Services", "code": 6490 }, { "name": "6511 - Physicians Office", "code": 6511 }, { "name": "6512 - Dental Office", "code": 6512 }, { "name": "6513 - Hospital", "code": 6513 }, { "name": "6516 - Rest Home", "code": 6516 }, { "name": "6517 - Medical Clinic/Emergency Centers", "code": 6517 }, { "name": "6520 - Legal Services", "code": 6520 }, { "name": "6530 - Engineering, Architectural & Planning Services", "code": 6530 }, { "name": "6540 - Research Services (INL)", "code": 6540 }, { "name": "6590 - Other Professional Services", "code": 6590 }, { "name": "6600 - Contract Construction Services", "code": 6600 }, { "name": "6700 - Governmental Services", "code": 6700 }, { "name": "6710 - Executive, Legislative & Judicial Functions", "code": 6710 }, { "name": "6721 - Police Services", "code": 6721 }, { "name": "6723 - Fire Services", "code": 6723 }, { "name": "6724 - Civil Defense", "code": 6724 }, { "name": "6725 - Health Services", "code": 6725 }, { "name": "6730 - Postal Services (Government)", "code": 6730 }, { "name": "6740 - Correctional Institution", "code": 6740 }, { "name": "6815 - Day Care Center", "code": 6815 }, { "name": "6911 - Church, Synagogue & Temple", "code": 6911 }, { "name": "6920 - Welfare & Charitable Services", "code": 6920 }, { "name": "6930 - Business, Professional & Labor Organizations & Services", "code": 6930 }, { "name": "6940 - Social, Fraternal & Youth Organizations & Services", "code": 6940 }, { "name": "6950 - Political, Civic & Veterans Organizations", "code": 6950 }, { "name": "6960 - Organizations & Clubs", "code": 6960 }, { "name": "6990 - Recycling Center", "code": 6990 }, { "name": "6994 - Senior Citizens Center", "code": 6994 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 100, "name": "SRV - Services" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC RTL", "description": "Valid standard land use code RTL values", "codedValues": [ { "name": "5200 - Building Materials, Hardware, Farm Equipment & Supplies", "code": 5200 }, { "name": "5300 - General Merchandise", "code": 5300 }, { "name": "5310 - Shopping Center/Mall", "code": 5310 }, { "name": "5311 - Department Store", "code": 5311 }, { "name": "5312 - Discount Department Store", "code": 5312 }, { "name": "5313 - Surplus Store", "code": 5313 }, { "name": "5330 - Variety Store", "code": 5330 }, { "name": "5350 - Direct Selling Organization", "code": 5350 }, { "name": "5390 - Other Retail Trade - General Merchandise", "code": 5390 }, { "name": "5411 - Grocery Store/Supermarket", "code": 5411 }, { "name": "5412 - Convenience Store", "code": 5412 }, { "name": "5420 - Meat & Fish", "code": 5420 }, { "name": "5430 - Produce", "code": 5430 }, { "name": "5440 - Candy & Confectionery", "code": 5440 }, { "name": "5450 - Dairy Products", "code": 5450 }, { "name": "5460 - Bakeries & Donut Shops", "code": 5460 }, { "name": "5490 - Other Food Related Trade (Health Foods, Catering, Delicatessen, etc.)", "code": 5490 }, { "name": "5510 - Motor Vehicles", "code": 5510 }, { "name": "5520 - Tires, Batteries & Accessories (auto parts stores)", "code": 5520 }, { "name": "5530 - Gas Station", "code": 5530 }, { "name": "5590 - Other Automotive, Marine Crafts, Aircraft, Motorcycles, Snow Machines & Accessories", "code": 5590 }, { "name": "5600 - Apparel & Accessories", "code": 5600 }, { "name": "5710 - Furniture, Home Furnishings & Equipment", "code": 5710 }, { "name": "5720 - Household Appliances", "code": 5720 }, { "name": "5730 - Electronics", "code": 5730 }, { "name": "5740 - Office Equipment & Furniture", "code": 5740 }, { "name": "5811 - Restaurants (with or without liquor)", "code": 5811 }, { "name": "5812 - Short Order Sit Down", "code": 5812 }, { "name": "5813 - Short Order Drive-In", "code": 5813 }, { "name": "5814 - Short Order without Drive-Thru (coffee shops, lunch counters, snack bars)", "code": 5814 }, { "name": "5820 - Drinking Places - Alcoholic Beverages", "code": 5820 }, { "name": "5910 - Drug & Pharmacy", "code": 5910 }, { "name": "5920 - Liquor Store", "code": 5920 }, { "name": "5930 - Antiques & Secondhand Merchandise", "code": 5930 }, { "name": "5940 - Books, Stationery, Art & Hobby Supplies", "code": 5940 }, { "name": "5950 - Sporting Goods", "code": 5950 }, { "name": "5960 - Farm & Garden Supplies", "code": 5960 }, { "name": "5969 - Nursery Plants & Garden Supplies", "code": 5969 }, { "name": "5970 - Jewelry Store", "code": 5970 }, { "name": "5980 - Fuel & Ice", "code": 5980 }, { "name": "5990 - Miscellaneous Retail Trade", "code": 5990 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 110, "name": "CBDRL - Central Business District Retail Trade" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC SRV", "description": "Valid standard land use code SRV values", "codedValues": [ { "name": "6110 - Banking & Related Functions", "code": 6110 }, { "name": "6120 - Credit Services", "code": 6120 }, { "name": "6130 - Security & Commodity Brokers, Dealers, Exchanges & Services", "code": 6130 }, { "name": "6140 - Insurance Carriers, Agents, Brokers & Services", "code": 6140 }, { "name": "6150 - Real Estate & Related Services", "code": 6150 }, { "name": "6160 - Holding & Investment Services", "code": 6160 }, { "name": "6210 - Laundering & Dry Cleaning", "code": 6210 }, { "name": "6220 - Photographic Services", "code": 6220 }, { "name": "6230 - Beauty & Barber Services", "code": 6230 }, { "name": "6241 - Funeral Home", "code": 6241 }, { "name": "6242 - Cemeteries", "code": 6242 }, { "name": "6243 - Crematory", "code": 6243 }, { "name": "6250 - Apparel & Shoe Repair", "code": 6250 }, { "name": "6291 - Clothing Rental", "code": 6291 }, { "name": "6292 - Costume Rental", "code": 6292 }, { "name": "6295 - Tattooing", "code": 6295 }, { "name": "6296 - Massage Parlors", "code": 6296 }, { "name": "6310 - Advertising Services", "code": 6310 }, { "name": "6320 - Credit Reporting Services, Adjustment & Collections Services", "code": 6320 }, { "name": "6330 - Duplicating, Mailing & Office Services", "code": 6330 }, { "name": "6340 - Dwelling Cleaning, Maintenance & Building Services", "code": 6340 }, { "name": "6360 - Employment Services", "code": 6360 }, { "name": "6370 - Warehousing & Storage Services", "code": 6370 }, { "name": "6371 - Farming Products Warehousing", "code": 6371 }, { "name": "6372 - Stockyards", "code": 6372 }, { "name": "6390 - Business Services", "code": 6390 }, { "name": "6410 - Automobile Repair & Related Services", "code": 6410 }, { "name": "6420 - Electrical Appliance Repair & Services", "code": 6420 }, { "name": "6490 - Repair Shops & Related Services", "code": 6490 }, { "name": "6511 - Physicians Office", "code": 6511 }, { "name": "6512 - Dental Office", "code": 6512 }, { "name": "6513 - Hospital", "code": 6513 }, { "name": "6516 - Rest Home", "code": 6516 }, { "name": "6517 - Medical Clinic/Emergency Centers", "code": 6517 }, { "name": "6520 - Legal Services", "code": 6520 }, { "name": "6530 - Engineering, Architectural & Planning Services", "code": 6530 }, { "name": "6540 - Research Services (INL)", "code": 6540 }, { "name": "6590 - Other Professional Services", "code": 6590 }, { "name": "6600 - Contract Construction Services", "code": 6600 }, { "name": "6700 - Governmental Services", "code": 6700 }, { "name": "6710 - Executive, Legislative & Judicial Functions", "code": 6710 }, { "name": "6721 - Police Services", "code": 6721 }, { "name": "6723 - Fire Services", "code": 6723 }, { "name": "6724 - Civil Defense", "code": 6724 }, { "name": "6725 - Health Services", "code": 6725 }, { "name": "6730 - Postal Services (Government)", "code": 6730 }, { "name": "6740 - Correctional Institution", "code": 6740 }, { "name": "6815 - Day Care Center", "code": 6815 }, { "name": "6911 - Church, Synagogue & Temple", "code": 6911 }, { "name": "6920 - Welfare & Charitable Services", "code": 6920 }, { "name": "6930 - Business, Professional & Labor Organizations & Services", "code": 6930 }, { "name": "6940 - Social, Fraternal & Youth Organizations & Services", "code": 6940 }, { "name": "6950 - Political, Civic & Veterans Organizations", "code": 6950 }, { "name": "6960 - Organizations & Clubs", "code": 6960 }, { "name": "6990 - Recycling Center", "code": 6990 }, { "name": "6994 - Senior Citizens Center", "code": 6994 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 120, "name": "CBDSV - Central Business District Services" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC CER", "description": "Valid standard land use CER values", "codedValues": [ { "name": "7111 - Library", "code": 7111 }, { "name": "7112 - Museum", "code": 7112 }, { "name": "7113 - Art Gallery", "code": 7113 }, { "name": "7123 - Botanical Garden", "code": 7123 }, { "name": "7124 - Zoo", "code": 7124 }, { "name": "7191 - Historical & Monument Site", "code": 7191 }, { "name": "7212 - Theater", "code": 7212 }, { "name": "7213 - Drive-in Theater", "code": 7213 }, { "name": "7221 - Stadium", "code": 7221 }, { "name": "7222 - Arena", "code": 7222 }, { "name": "7223 - Race Track - Animal", "code": 7223 }, { "name": "7224 - Race Track - Auto", "code": 7224 }, { "name": "7231 - Auditorium", "code": 7231 }, { "name": "7232 - Exhibition Hall", "code": 7232 }, { "name": "7233 - Convention Center", "code": 7233 }, { "name": "7234 - Civic Theater", "code": 7234 }, { "name": "7311 - Fairgrounds", "code": 7311 }, { "name": "7312 - Amusement Park", "code": 7312 }, { "name": "7391 - Arcade", "code": 7391 }, { "name": "7392 - Miniature Golf", "code": 7392 }, { "name": "7396 - Dance Hall", "code": 7396 }, { "name": "7397 - Billiard", "code": 7397 }, { "name": "7411 - Golf Course - Public", "code": 7411 }, { "name": "7412 - Golf Course - Private", "code": 7412 }, { "name": "7413 - Tennis Court", "code": 7413 }, { "name": "7414 - Ice Skating", "code": 7414 }, { "name": "7415 - Roller Skating", "code": 7415 }, { "name": "7416 - Riding Academy", "code": 7416 }, { "name": "7417 - Bowling Alley", "code": 7417 }, { "name": "7421 - Playground", "code": 7421 }, { "name": "7423 - Athletic Field", "code": 7423 }, { "name": "7424 - Recreation & Community Center", "code": 7424 }, { "name": "7425 - Gymnasium", "code": 7425 }, { "name": "7426 - Baseball Field", "code": 7426 }, { "name": "7432 - Swimming Pool", "code": 7432 }, { "name": "7433 - Water Park", "code": 7433 }, { "name": "7442 - Boat Access Site", "code": 7442 }, { "name": "7443 - Sports Fishing Activities", "code": 7443 }, { "name": "7451 - Archery Range", "code": 7451 }, { "name": "7452 - Gun Range", "code": 7452 }, { "name": "7491 - RV Parking & Camping Area", "code": 7491 }, { "name": "7611 - Developed Park", "code": 7611 }, { "name": "7612 - Undeveloped Park", "code": 7612 }, { "name": "7621 - Green Belt", "code": 7621 }, { "name": "7691 - Landscaped Lot", "code": 7691 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 130, "name": "CER - Cultural, Entertainment & Recreation" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC AGL", "description": "Valid standard land use code AGL values", "codedValues": [ { "name": "8100 - Agriculture", "code": 8100 }, { "name": "8144 - Dairy", "code": 8144 }, { "name": "8221 - Veterinarian", "code": 8221 }, { "name": "8224 - Kennel", "code": 8224 }, { "name": "8292 - Tree Planting, Pruning, Spraying", "code": 8292 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 140, "name": "AGL - Agricultural" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC MNG", "description": "Valid standard land use code MNG values", "codedValues": [ { "name": "8543 - Gravel Pit", "code": 8543 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 150, "name": "MNG - Mining" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC VCT", "description": "Valid standard land use code VCT values", "codedValues": [ { "name": "9100 - Vacant Land", "code": 9100 }, { "name": "9400 - Vacant Building", "code": 9400 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 160, "name": "VCT - Vacant" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC WTR", "description": "Valid standard land use code WTR values", "codedValues": [ { "name": "9310 - Snake River", "code": 9310 }, { "name": "9311 - Canal/Stream", "code": 9311 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 170, "name": "WTR - Water Areas" }, { "domains": { "StandardLandUseCode": { "type": "codedValue", "name": "WS3_SLUC ROW", "description": "Valid standard land use code ROW values", "codedValues": [ { "name": "4500 - Highway and Street Right-of-Way", "code": 4500 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, "defaultValues": { "StandardLandUseType": null, "StandardLandUseCode": null, "Comments": null, "CreateUser": null, "CreateDate": null, "EditUser": null, "EditDate": null, "GlobalID": null }, "code": 180, "name": "ROW - Streets & Right-of-Ways" } ], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 900, "name": "Form Based Code", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 910, "name": "Form Based District" }, { "id": 920, "name": "Form Based Subdistrict" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 687888.7329999991, "ymin": 662118.0555000007, "xmax": 697048.8330000006, "ymax": 672455.1110000014, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 910, "name": "Form Based District", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 900, "name": "Form Based Code" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "DistrictName", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSVertical", "color": [ 255, 0, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 2 } }, "value": "Downtown", "label": "Downtown" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 230, 0, 0, 255 ], "width": 2 } }, "value": "South Downtown", "label": "South Downtown" }, { "symbol": { "type": "esriSFS", "style": "esriSFSBackwardDiagonal", "color": [ 255, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 255, 255, 0, 255 ], "width": 4 } }, "value": "Northgate 1st St", "label": "Northgate 1st St" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 687888.7329999991, "ymin": 662118.0555000007, "xmax": 697048.8330000006, "ymax": 672455.1110000014, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "DistrictName", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "DistrictName", "type": "esriFieldTypeString", "alias": "District Name", "length": 100, "domain": { "type": "codedValue", "name": "WS3_PLN Form Based District Name", "description": "Valid planning form based district name values", "codedValues": [ { "name": "Downtown", "code": "Downtown" }, { "name": "South Downtown", "code": "South Downtown" }, { "name": "Northgate 1st St", "code": "Northgate 1st St" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_230", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S193_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 920, "name": "Form Based Subdistrict", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 900, "name": "Form Based Code" }, "subLayers": [], "minScale": 60000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "SubdistrictName", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 230, 0, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Historic Core", "label": "Historic Core" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 170, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Core A", "label": "Core A" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 112, 168, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Edge A", "label": "Edge A" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 112, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Edge B", "label": "Edge B" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 235, 190, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "General A", "label": "General A" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 178, 178, 178, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Edge C", "label": "Edge C" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 112, 168, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "River Edge", "label": "River Edge" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 223, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Warehouse District", "label": "Warehouse District" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 223, 115, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Business Core", "label": "Business Core" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Historic Residential", "label": "Historic Residential" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 112, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "Commercial Edge", "label": "Commercial Edge" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 50, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 688151.5150000006, "ymin": 662316.814000003, "xmax": 691323.3040000014, "ymax": 667839.310999997, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "SubdistrictName", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "DistrictName", "type": "esriFieldTypeString", "alias": "DistrictName", "length": 100, "domain": { "type": "codedValue", "name": "WS3_PLN Form Based District Name", "description": "Valid planning form based district name values", "codedValues": [ { "name": "Downtown", "code": "Downtown" }, { "name": "South Downtown", "code": "South Downtown" }, { "name": "Northgate 1st St", "code": "Northgate 1st St" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SubdistrictName", "type": "esriFieldTypeString", "alias": "Subdistrict Name", "length": 100, "domain": { "type": "codedValue", "name": "WS3_PLN Form Based Subdistrict Name", "description": "Valid planning form based subdistrict name values", "codedValues": [ { "name": "Business Core", "code": "Business Core" }, { "name": "Commercial Edge", "code": "Commercial Edge" }, { "name": "Core A", "code": "Core A" }, { "name": "Downtown", "code": "Downtown" }, { "name": "Edge A", "code": "Edge A" }, { "name": "Edge B", "code": "Edge B" }, { "name": "Edge C", "code": "Edge C" }, { "name": "General A", "code": "General A" }, { "name": "Historic Core", "code": "Historic Core" }, { "name": "Historic Residential", "code": "Historic Residential" }, { "name": "River Edge", "code": "River Edge" }, { "name": "Warehouse District", "code": "Warehouse District" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": {}, "indexes": [ { "name": "UUID_231", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771076604000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 970, "name": "Annexation", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 980, "name": "Idaho Falls Annexation" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 673765.1570000015, "ymin": 643478.9935000017, "xmax": 707353.4065000005, "ymax": 689855.1550000012, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 980, "name": "Idaho Falls Annexation", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 970, "name": "Annexation" }, "subLayers": [], "minScale": 120000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSDiagonalCross", "color": [ 0, 255, 197, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 255, 197, 255 ], "width": 4 } } }, "scaleSymbols": true, "transparency": 50, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 673765.1570000015, "ymin": 643478.9935000017, "xmax": 707353.4065000005, "ymax": 689855.1550000012, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": true, "attachmentProperties": [ { "name": "id", "fieldName": "ATTACHMENTID", "isEnabled": true }, { "name": "globalid", "fieldName": "GLOBALID", "isEnabled": true }, { "name": "keywords", "fieldName": "KEYWORDS", "isEnabled": false }, { "name": "name", "fieldName": "ATT_NAME", "isEnabled": true }, { "name": "contentType", "fieldName": "CONTENT_TYPE", "isEnabled": true }, { "name": "size", "fieldName": "DATA_SIZE", "isEnabled": true }, { "name": "exifInfo", "fieldName": "EXIFINFO", "isEnabled": false } ], "attachmentFields": [ { "name": "ATTACHMENTID", "type": "esriFieldTypeOID", "alias": "ATTACHMENTID", "editable": false, "nullable": false, "length": 4, "domain": null }, { "name": "GLOBALID", "type": "esriFieldTypeGlobalID", "alias": "GLOBALID", "editable": false, "nullable": false, "length": 38, "domain": null }, { "name": "ATT_NAME", "type": "esriFieldTypeString", "alias": "ATT_NAME", "editable": true, "nullable": false, "length": 250, "domain": null }, { "name": "CONTENT_TYPE", "type": "esriFieldTypeString", "alias": "CONTENT_TYPE", "editable": true, "nullable": false, "length": 150, "domain": null }, { "name": "DATA_SIZE", "type": "esriFieldTypeInteger", "alias": "DATA_SIZE", "editable": true, "nullable": false, "length": 4, "domain": null } ], "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayFieldExpressionInfo": { "expression": "\"Annexation - \" + $feature.OrdinanceNumber", "title": "DisplayField" }, "displayField": "Type", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 25, "domain": { "type": "codedValue", "name": "WS3_CTL Annexation Type", "description": "Valid city limit annexation type values", "codedValues": [ { "name": "Annexation", "code": "Annexation" }, { "name": "Deannexation", "code": "Deannexation" }, { "name": "Repeal", "code": "Repeal" }, { "name": "Affidavit of Correction", "code": "Affidavit of Correction" }, { "name": "Gap", "code": "Gap" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDefaultValue" } }, { "name": "Description", "type": "esriFieldTypeString", "alias": "Description", "length": 100, "domain": null }, { "name": "OrdinanceNumber", "type": "esriFieldTypeString", "alias": "Ordinance #", "length": 25, "domain": null }, { "name": "OrdinanceDate", "type": "esriFieldTypeDate", "alias": "Ordinance Date", "length": 8, "domain": null }, { "name": "Acres", "type": "esriFieldTypeDouble", "alias": "Acres", "domain": null }, { "name": "RecordNumber", "type": "esriFieldTypeString", "alias": "Record #", "length": 30, "domain": null }, { "name": "RecordDate", "type": "esriFieldTypeDate", "alias": "Record Date", "length": 8, "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "S78_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAttachments": true, "supportsQueryAttachmentsWithReturnUrl": true, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075859000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1000, "name": "Connecting our Community 2021", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 1010, "name": "Spot Improvement Recommendation 2021" }, { "id": 1020, "name": "Linear Facility Recommendation 2021" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 672864.8209999986, "ymin": 638583.5289999992, "xmax": 726895.6295000017, "ymax": 714388.2959999964, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1010, "name": "Spot Improvement Recommendation 2021", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPoint", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1000, "name": "Connecting our Community 2021" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Type", "uniqueValueInfos": [ { "symbol": { "type": "esriSMS", "style": "esriSMSCircle", "color": [ 56, 168, 0, 255 ], "size": 10, "angle": 0, "xoffset": 0, "yoffset": 0, "outline": { "color": [ 0, 0, 0, 255 ], "width": 0.6 } }, "value": "At Grade Spot Improvement", "label": "At Grade Spot Improvement" }, { "symbol": { "type": "esriSMS", "style": "esriSMSCircle", "color": [ 0, 255, 197, 255 ], "size": 10, "angle": 0, "xoffset": 0, "yoffset": 0, "outline": { "color": [ 0, 0, 0, 255 ], "width": 0.6 } }, "value": "Bridge or Underpass/Tunnel", "label": "Bridge or Underpass/Tunnel" }, { "symbol": { "type": "esriSMS", "style": "esriSMSCircle", "color": [ 137, 112, 68, 255 ], "size": 10, "angle": 0, "xoffset": 0, "yoffset": 0, "outline": { "color": [ 0, 0, 0, 255 ], "width": 0.6 } }, "value": "Signal Spot Improvement", "label": "Signal Spot Improvement" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674219.306499999, "ymin": 646000.5174999982, "xmax": 718873.1524999999, "ymax": 701530.5694999993, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 100, "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 50, "domain": { "type": "codedValue", "name": "WS3_COC Spot Improvements Type", "description": "Valid connecting our community spot improvements type values", "codedValues": [ { "name": "At Grade Spot Improvement", "code": "At Grade Spot Improvement" }, { "name": "Bridge or Underpass/Tunnel", "code": "Bridge or Underpass/Tunnel" }, { "name": "Signal Spot Improvement", "code": "Signal Spot Improvement" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_111", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S84_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075911000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1020, "name": "Linear Facility Recommendation 2021", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1000, "name": "Connecting our Community 2021" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Type", "uniqueValueInfos": [ { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 112, 255, 255 ], "width": 3 }, "value": "Shared Use Path", "label": "Shared Use Path" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 0, 0, 255 ], "width": 3 }, "value": "Bike Lane", "label": "Bike Lane" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 197, 0, 255, 255 ], "width": 3 }, "value": "Buffered Bike Lane", "label": "Buffered Bike Lane" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 85, 255, 0, 255 ], "width": 3 }, "value": "Signed Bike Route", "label": "Signed Bike Route" }, { "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 170, 0, 255 ], "width": 3 }, "value": "Sidewalk", "label": "Sidewalk" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 255, 255, 0, 255 ], "width": 3 }, "value": "Proposed Addition", "label": "Proposed Addition" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 197, 0, 255, 255 ], "width": 3 }, "value": "Proposed Buffered Bike Lane", "label": "Proposed Buffered Bike Lane" }, { "symbol": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 0, 112, 255, 255 ], "width": 3 }, "value": "Proposed Shared Use Path", "label": "Proposed Shared Use Path" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 672864.8209999986, "ymin": 638583.5289999992, "xmax": 726895.6295000017, "ymax": 714388.2959999964, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Name", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "OBJECTID", "domain": null }, { "name": "Name", "type": "esriFieldTypeString", "alias": "Name", "length": 100, "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 30, "domain": { "type": "codedValue", "name": "WS3_COC Linear Facilities Type", "description": "Valid connecting our community linear facilities type values", "codedValues": [ { "name": "Shared Use Path", "code": "Shared Use Path" }, { "name": "Buffered Bike Lane", "code": "Buffered Bike Lane" }, { "name": "Bike Lane", "code": "Bike Lane" }, { "name": "Signed Bike Route", "code": "Signed Bike Route" }, { "name": "Sidewalk", "code": "Sidewalk" }, { "name": "Proposed Buffered Bike Lane", "code": "Proposed Buffered Bike Lane" }, { "name": "Proposed Shared Use Path", "code": "Proposed Shared Use Path" }, { "name": "Proposed Addition", "code": "Proposed Addition" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "SHAPE", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "SHAPE" }, "indexes": [ { "name": "UUID_110", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S83_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075911000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1100, "name": "Floodplain", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 1110, "name": "Floodplain Buffer" }, { "id": 1120, "name": "River Buffer" }, { "id": 1130, "name": "Floodplain" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 667190.75, "ymin": 638359.8125, "xmax": 726218.625, "ymax": 714976.5, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1110, "name": "Floodplain Buffer", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1100, "name": "Floodplain" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 130, 130, 130, 0 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 0, 112, 255, 255 ], "width": 1 } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 674102.2745000012, "ymin": 640894.6269999966, "xmax": 689604.1490000002, "ymax": 692606.049999997, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "BufferType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Zone", "type": "esriFieldTypeString", "alias": "Zone", "length": 5, "domain": { "type": "codedValue", "name": "WS3_WTBD Floodplain Zone", "description": "Valid water body floodplain zone values", "codedValues": [ { "name": "A - 100 Year Flood", "code": "A" }, { "name": "A1 - 100 Year Flood", "code": "A1" }, { "name": "A2 - 100 Year Flood", "code": "A2" }, { "name": "AO - 100 Year Flood (2-3 ft Deep)", "code": "AO" }, { "name": "B - 100 to 500 Year Flood", "code": "B" }, { "name": "C - Minimal Flooding", "code": "C" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "BufferType", "type": "esriFieldTypeString", "alias": "Buffer Type", "length": 50, "domain": { "type": "codedValue", "name": "WS3_WTBD Floodplain Buffer Type", "description": "Valid water body floodplain buffer type values", "codedValues": [ { "name": "75 ft", "code": "75 ft" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_396", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S345_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771077332000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1120, "name": "River Buffer", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1100, "name": "Floodplain" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 85, 255, 0, 0 ], "outline": { "type": "esriSLS", "style": "esriSLSDash", "color": [ 85, 255, 0, 255 ], "width": 1 } } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 672605, "ymin": 638359.8125, "xmax": 690247.125, "ymax": 714976.5, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "BufferType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "BufferType", "type": "esriFieldTypeString", "alias": "Buffer Type", "length": 50, "domain": { "type": "codedValue", "name": "WS3_WTBD River Buffer Type", "description": "Valid water body river buffer type values", "codedValues": [ { "name": "750 ft", "code": "750 ft" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_401", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S350_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771077332000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1130, "name": "Floodplain", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1100, "name": "Floodplain" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "Zone", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 170, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 1 } }, "value": "A", "label": "A - 100 Year Flood" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 255, 223, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 1 } }, "value": "A1", "label": "A1 - 100 Year Flood" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 115, 178, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 1 } }, "value": "A2", "label": "A2 - 100 Year Flood" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 127, 127, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 1 } }, "value": "AO", "label": "AO - 100 Year Flood (2-3 ft Deep)" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 235, 175, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 1 } }, "value": "B", "label": "B - 100 to 500 Year Flood" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 190, 232, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 0 ], "width": 0.7 } }, "value": "C", "label": "C - Minimal Flooding" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 50, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 667190.75, "ymin": 640969.625, "xmax": 726218.625, "ymax": 692531.0625, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Zone", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Zone", "type": "esriFieldTypeString", "alias": "Zone", "length": 5, "domain": { "type": "codedValue", "name": "WS3_WTBD Floodplain Zone", "description": "Valid water body floodplain zone values", "codedValues": [ { "name": "A - 100 Year Flood", "code": "A" }, { "name": "A1 - 100 Year Flood", "code": "A1" }, { "name": "A2 - 100 Year Flood", "code": "A2" }, { "name": "AO - 100 Year Flood (2-3 ft Deep)", "code": "AO" }, { "name": "B - 100 to 500 Year Flood", "code": "B" }, { "name": "C - Minimal Flooding", "code": "C" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "I844Zone", "fields": "Zone", "isAscending": true, "isUnique": false, "description": "" }, { "name": "UUID_398", "fields": "GlobalID", "isAscending": true, "isUnique": true, "description": "" }, { "name": "S347_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771077332000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1200, "name": "Airport Land Use", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 1210, "name": "Airport" }, { "id": 1220, "name": "Airport Land Use" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 663970.5245000012, "ymin": 655243.7915000021, "xmax": 720682.8724999987, "ymax": 720837.7154999971, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1210, "name": "Airport", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1200, "name": "Airport Land Use" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 0, 0, 255 ], "width": 0.7 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 677906.1750000007, "ymin": 668971.450000003, "xmax": 684994.1424999982, "ymax": 676555.6194999963, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "SHAPE.STLength()", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_21", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S8_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1220, "name": "Airport Land Use", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1200, "name": "Airport Land Use" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "CompatibleLandUse", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 112, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "Approach Surface", "label": "Approach Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 230, 169, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "Controlled Development", "label": "Controlled Development" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 197, 0, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "Controlled Development Approach Surface", "label": "Controlled Development Approach Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "Limited Development", "label": "Limited Development" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 170, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "Limited Development Approach Surface", "label": "Limited Development Approach Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "value": "No Development", "label": "No Development" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 60, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 663970.5245000012, "ymin": 655243.7915000021, "xmax": 720682.8724999987, "ymax": 720837.7154999971, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "CompatibleLandUse", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "CompatibleLandUse", "type": "esriFieldTypeString", "alias": "Compatible Land Use", "length": 50, "domain": { "type": "codedValue", "name": "WS3_AIR Land Use Compatible Land Use", "description": "Valid airport land use compatible land use values", "codedValues": [ { "name": "Approach Surface", "code": "Approach Surface" }, { "name": "Controlled Development", "code": "Controlled Development" }, { "name": "Controlled Development Approach Surface", "code": "Controlled Development Approach Surface" }, { "name": "Limited Development", "code": "Limited Development" }, { "name": "Limited Development Approach Surface", "code": "Limited Development Approach Surface" }, { "name": "No Development", "code": "No Development" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_18", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S5_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1300, "name": "Airport Height Check", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 1310, "name": "Airport" }, { "id": 1320, "name": "Airport Height Limitation Contour" }, { "id": 1330, "name": "Airport Height Limitation Zone" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 663808.3115000017, "ymin": 654992.8294999972, "xmax": 724674.6215000004, "ymax": 723976.6330000013, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1310, "name": "Airport", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1300, "name": "Airport Height Check" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 0, 0, 255 ], "width": 0.7 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 677906.1750000007, "ymin": 668971.450000003, "xmax": 684994.1424999982, "ymax": 676555.6194999963, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "SHAPE.STLength()", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_21", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S8_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1320, "name": "Airport Height Limitation Contour", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1300, "name": "Airport Height Check" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 0, 0, 0, 255 ], "width": 0.7 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 663808.3115000017, "ymin": 654992.8294999972, "xmax": 724674.6215000004, "ymax": 723976.6330000013, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "Elevation", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Elevation", "type": "esriFieldTypeSingle", "alias": "Elevation (ft.)", "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_15", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S2_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1330, "name": "Airport Height Limitation Zone", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1300, "name": "Airport Height Check" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "SurfaceType", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 230, 152, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "Approach Surface", "label": "Approach Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 77, 168, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "Conical Surface", "label": "Conical Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 230, 169, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "Horizontal Surface", "label": "Horizontal Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 52, 52, 52, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "Primary Surface", "label": "Primary Surface" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "Transitional Surface", "label": "Transitional Surface" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 192, 197, 255 ], "toColor": [ 252, 192, 197, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 180, 252, 179, 255 ], "toColor": [ 180, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 184, 252, 255 ], "toColor": [ 179, 184, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 202, 252, 252, 255 ], "toColor": [ 202, 252, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 247, 199, 255 ], "toColor": [ 252, 247, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 184, 250, 255 ], "toColor": [ 252, 184, 250, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 230, 215, 252, 255 ], "toColor": [ 230, 215, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 222, 255 ], "toColor": [ 179, 252, 222, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 218, 252, 255 ], "toColor": [ 179, 218, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 182, 255 ], "toColor": [ 252, 212, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 216, 252, 204, 255 ], "toColor": [ 216, 252, 204, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 202, 233, 255 ], "toColor": [ 252, 202, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 222, 215, 255 ], "toColor": [ 252, 222, 215, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 60, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 663808.3115000017, "ymin": 654992.8294999972, "xmax": 724674.6215000004, "ymax": 723976.6330000013, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "SurfaceType", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "SurfaceType", "type": "esriFieldTypeString", "alias": "Surface Type", "length": 25, "domain": { "type": "codedValue", "name": "WS3_AIR Height Limitation Zone Surface Type", "description": "Valid airport height limitation zone surface type values", "codedValues": [ { "name": "Approach Surface", "code": "Approach Surface" }, { "name": "Conical Surface", "code": "Conical Surface" }, { "name": "Horizontal Surface", "code": "Horizontal Surface" }, { "name": "Primary Surface", "code": "Primary Surface" }, { "name": "Transitional Surface", "code": "Transitional Surface" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "Elevation", "type": "esriFieldTypeSingle", "alias": "Elevation (ft.)", "domain": null }, { "name": "Ratio", "type": "esriFieldTypeString", "alias": "Ratio", "length": 10, "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_20", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S7_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1400, "name": "Airport Noise Contours", "type": "Group Layer", "description": "", "geometryType": null, "copyrightText": "", "parentLayer": null, "subLayers": [ { "id": 1410, "name": "Airport" }, { "id": 1420, "name": "Airport Current Noise Contour" }, { "id": 1430, "name": "Airport Future Noise Contour" } ], "minScale": 0, "maxScale": 0, "defaultVisibility": false, "extent": { "xmin": 652837.7864999995, "ymin": 655452.9704999998, "xmax": 722849.3449999988, "ymax": 692391.8154999986, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeNone", "displayField": "", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": null, "geometryField": {}, "indexes": [], "subtypes": [], "relationships": [], "canModifyLayer": false, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query", "supportsStatistics": false, "supportsExceedsLimitStatistics": false, "supportsAdvancedQueries": false, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": false, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": false, "supportsPercentileStatistics": false, "supportsHavingClause": false, "supportsOrderBy": false, "supportsDistinct": false, "supportsCountDistinct": false, "supportsPagination": false, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": false, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": false }, "supportsDatumTransformation": true, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasMetadata": true, "isDataArchived": false, "archivingInfo": { "supportsQueryWithHistoricMoment": false, "startArchivingMoment": -1 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": false }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1410, "name": "Airport", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolyline", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1400, "name": "Airport Noise Contours" }, "subLayers": [], "minScale": 240000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "simple", "symbol": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 255, 0, 0, 255 ], "width": 0.7 } }, "scaleSymbols": true, "transparency": 0, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 677906.1750000007, "ymin": 668971.450000003, "xmax": 684994.1424999982, "ymax": 676555.6194999963, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "SHAPE.STLength()", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_21", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S8_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1420, "name": "Airport Current Noise Contour", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1400, "name": "Airport Noise Contours" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "DayNightLevel", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 197, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "45", "label": "45" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 197, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "50", "label": "50" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 76, 230, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "55", "label": "55" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 132, 0, 168, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "60", "label": "60" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 170, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "65", "label": "65" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 255, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "70", "label": "70" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "75", "label": "75" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 246, 252, 255 ], "toColor": [ 212, 246, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 239, 182, 252, 255 ], "toColor": [ 239, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 250, 252, 179, 255 ], "toColor": [ 250, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 185, 182, 255 ], "toColor": [ 252, 185, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 199, 255 ], "toColor": [ 179, 252, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 192, 203, 252, 255 ], "toColor": [ 192, 203, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 242, 255 ], "toColor": [ 252, 212, 242, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 235, 215, 255 ], "toColor": [ 252, 235, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 222, 252, 215, 255 ], "toColor": [ 222, 252, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 190, 179, 252, 255 ], "toColor": [ 190, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 179, 212, 255 ], "toColor": [ 252, 179, 212, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 192, 252, 233, 255 ], "toColor": [ 192, 252, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 223, 252, 255 ], "toColor": [ 179, 223, 252, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 60, "labelingInfo": null }, "defaultVisibility": true, "extent": { "xmin": 652837.7864999995, "ymin": 655452.9704999998, "xmax": 722849.3449999988, "ymax": 692391.8154999986, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "DayNightLevel", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 10, "domain": { "type": "codedValue", "name": "WS3_AIR Noise Contour Type", "description": "Valid airport noise contour type values", "codedValues": [ { "name": "Current", "code": "Current" }, { "name": "Future", "code": "Future" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "DayNightLevel", "type": "esriFieldTypeSmallInteger", "alias": "Day-night Level (dBA)", "domain": { "type": "codedValue", "name": "WS3_AIR Noise Contour Day-night Level", "description": "Valid airport noise contour day-night level values", "codedValues": [ { "name": "45", "code": 45 }, { "name": "50", "code": 50 }, { "name": "55", "code": 55 }, { "name": "60", "code": 60 }, { "name": "65", "code": 65 }, { "name": "70", "code": 70 }, { "name": "75", "code": 75 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_17", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S4_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true }, { "currentVersion": 11.1, "cimVersion": "3.1.0", "id": 1430, "name": "Airport Future Noise Contour", "type": "Feature Layer", "description": "", "geometryType": "esriGeometryPolygon", "sourceSpatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]],VERTCS[\"NAVD88_height_(ftUS)\",VDATUM[\"North_American_Vertical_Datum_1988\"],PARAMETER[\"Vertical_Shift\",0.0],PARAMETER[\"Direction\",1.0],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.001, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 2000, "falseZ": -100000, "zUnits": 2000, "falseM": 0, "mUnits": 1 }, "sourceHeightModelInfo": { "heightModel": "gravity_related_height", "vertCRS": "NAVD88_height_(ftUS)", "heightUnit": "us-foot" }, "copyrightText": "", "parentLayer": { "id": 1400, "name": "Airport Noise Contours" }, "subLayers": [], "minScale": 600000, "maxScale": 0, "referenceScale": 0.0, "drawingInfo": { "renderer": { "type": "uniqueValue", "field1": "DayNightLevel", "uniqueValueInfos": [ { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 0, 197, 255, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "45", "label": "45" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 0, 197, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "50", "label": "50" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 76, 230, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "55", "label": "55" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 132, 0, 168, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "60", "label": "60" }, { "symbol": { "type": "esriSFS", "style": "esriSFSSolid", "color": [ 255, 170, 0, 255 ], "outline": { "type": "esriSLS", "style": "esriSLSSolid", "color": [ 110, 110, 110, 255 ], "width": 0.7 } }, "value": "65", "label": "65" } ], "fieldDelimiter": ",", "authoringInfo": { "colorRamp": { "type": "multipart", "colorRamps": [ { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 212, 246, 252, 255 ], "toColor": [ 212, 246, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 239, 182, 252, 255 ], "toColor": [ 239, 182, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 250, 252, 179, 255 ], "toColor": [ 250, 252, 179, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 185, 182, 255 ], "toColor": [ 252, 185, 182, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 252, 199, 255 ], "toColor": [ 179, 252, 199, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 192, 203, 252, 255 ], "toColor": [ 192, 203, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 212, 242, 255 ], "toColor": [ 252, 212, 242, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 235, 215, 255 ], "toColor": [ 252, 235, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 222, 252, 215, 255 ], "toColor": [ 222, 252, 215, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 190, 179, 252, 255 ], "toColor": [ 190, 179, 252, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 252, 179, 212, 255 ], "toColor": [ 252, 179, 212, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 192, 252, 233, 255 ], "toColor": [ 192, 252, 233, 255 ] }, { "type": "algorithmic", "algorithm": "esriCIELabAlgorithm", "fromColor": [ 179, 223, 252, 255 ], "toColor": [ 179, 223, 252, 255 ] } ] } } }, "scaleSymbols": true, "transparency": 60, "labelingInfo": null }, "defaultVisibility": false, "extent": { "xmin": 652837.7864999995, "ymin": 655452.9704999998, "xmax": 722849.3449999988, "ymax": 692391.8154999986, "spatialReference": { "wkt": "PROJCS[\"IF Ground\",GEOGCS[\"GCS_North_American_1983\",DATUM[\"D_North_American_1983\",SPHEROID[\"GRS_1980\",6378137.0,298.257222101]],PRIMEM[\"Greenwich\",0.0],UNIT[\"Degree\",0.0174532925199433]],PROJECTION[\"Transverse_Mercator\"],PARAMETER[\"False_Easting\",656348.5987174333],PARAMETER[\"False_Northing\",0.0],PARAMETER[\"Central_Meridian\",-112.1666666666667],PARAMETER[\"Scale_Factor\",1.000224618828],PARAMETER[\"Latitude_Of_Origin\",41.66666666666666],UNIT[\"Foot_US\",0.3048006096012192]]", "xyTolerance": 0.003280833333333333, "zTolerance": 0.001, "mTolerance": 0.001, "falseX": -17796300, "falseY": -47965700, "xyUnits": 3048.0060960121928, "falseZ": -100000, "zUnits": 10000, "falseM": -100000, "mUnits": 10000 } }, "hasAttachments": false, "htmlPopupType": "esriServerHTMLPopupTypeAsHTMLText", "displayField": "DayNightLevel", "typeIdField": null, "subtypeFieldName": null, "subtypeField": null, "defaultSubtypeCode": null, "fields": [ { "name": "OBJECTID", "type": "esriFieldTypeOID", "alias": "Object ID", "domain": null }, { "name": "Type", "type": "esriFieldTypeString", "alias": "Type", "length": 10, "domain": { "type": "codedValue", "name": "WS3_AIR Noise Contour Type", "description": "Valid airport noise contour type values", "codedValues": [ { "name": "Current", "code": "Current" }, { "name": "Future", "code": "Future" } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "DayNightLevel", "type": "esriFieldTypeSmallInteger", "alias": "Day-night Level (dBA)", "domain": { "type": "codedValue", "name": "WS3_AIR Noise Contour Day-night Level", "description": "Valid airport noise contour day-night level values", "codedValues": [ { "name": "45", "code": 45 }, { "name": "50", "code": 50 }, { "name": "55", "code": 55 }, { "name": "60", "code": 60 }, { "name": "65", "code": 65 }, { "name": "70", "code": 70 }, { "name": "75", "code": 75 } ], "mergePolicy": "esriMPTDefaultValue", "splitPolicy": "esriSPTDuplicate" } }, { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape", "domain": null }, { "name": "SHAPE.STArea()", "type": "esriFieldTypeDouble", "alias": "Area (sq. ft.)", "domain": null }, { "name": "SHAPE.STLength()", "type": "esriFieldTypeDouble", "alias": "Perimeter Length (ft.)", "domain": null }, { "name": "GlobalID", "type": "esriFieldTypeGlobalID", "alias": "GlobalID", "length": 38, "domain": null } ], "geometryField": { "name": "SHAPE", "type": "esriFieldTypeGeometry", "alias": "Shape" }, "indexes": [ { "name": "UUID_17", "fields": "GlobalID", "isAscending": true, "isUnique": false, "description": "" }, { "name": "S4_idx", "fields": "SHAPE", "isAscending": true, "isUnique": true, "description": "" } ], "subtypes": [], "relationships": [], "canModifyLayer": true, "canScaleSymbols": false, "hasLabels": false, "capabilities": "Map,Query,Data", "maxRecordCount": 2000, "supportsStatistics": true, "supportsExceedsLimitStatistics": true, "supportsAdvancedQueries": true, "hasZ": true, "supportedQueryFormats": "JSON, geoJSON, PBF", "isDataVersioned": true, "ownershipBasedAccessControlForFeatures": {"allowOthersToQuery": true}, "useStandardizedQueries": true, "supportedSpatialRelationships": [ "esriSpatialRelIntersects", "esriSpatialRelContains", "esriSpatialRelCrosses", "esriSpatialRelEnvelopeIntersects", "esriSpatialRelIndexIntersects", "esriSpatialRelOverlaps", "esriSpatialRelTouches", "esriSpatialRelWithin", "esriSpatialRelRelation" ], "advancedQueryCapabilities": { "useStandardizedQueries": true, "supportsStatistics": true, "supportsPercentileStatistics": true, "supportsHavingClause": true, "supportsOrderBy": true, "supportsDistinct": true, "supportsCountDistinct": true, "supportsPagination": true, "supportsLod": false, "supportsQueryWithLodSR": false, "supportsTrueCurve": true, "supportsQueryWithDatumTransformation": true, "supportsReturningQueryExtent": true, "supportsQueryWithDistance": true, "supportsSqlExpression": true, "supportsTimeRelation": true, "supportsSqlFormat": false, "supportsQueryAnalytic": true }, "supportsDatumTransformation": true, "advancedQueryAnalyticCapabilities": { "supportsLinearRegression": true, "supportsAsync": false, "supportsPercentileAnalytic": true }, "dateFieldsTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "preferredTimeReference": { "timeZone": "Mountain Standard Time", "respectsDaylightSaving": true }, "datesInUnknownTimezone": false, "hasGeometryProperties": true, "geometryProperties": { "shapeAreaFieldName": "SHAPE.STArea()", "shapeLengthFieldName": "SHAPE.STLength()", "units": "esriFeet", "mapUnits": {"uwkid": 9003} }, "hasMetadata": true, "isDataArchived": true, "archivingInfo": { "supportsQueryWithHistoricMoment": true, "startArchivingMoment": 1771075223000 }, "supportsCoordinatesQuantization": true, "supportsDynamicLegends": true } ], "tables": [] }